期刊文献+
共找到60篇文章
< 1 2 3 >
每页显示 20 50 100
Performance Evaluation of Solar Chimney Draft: Application to Ventilation
1
作者 Boukaré Ouedraogo Adama Ouedraogo +2 位作者 Arouna Kabore Kalifa Palm Dieudonné Joseph Bahiebo 《Smart Grid and Renewable Energy》 2024年第4期107-122,共16页
Ventilation is one of the factors contributing to energy consumption in buildings and food preservation. The solar chimney proves to be an alternative for reducing conventional energy consumption. Thus, in this study,... Ventilation is one of the factors contributing to energy consumption in buildings and food preservation. The solar chimney proves to be an alternative for reducing conventional energy consumption. Thus, in this study, the performance of a solar chimney with two active faces for thermally drawing air from a chamber for preserving agri-food products was evaluated. These performances were experimentally assessed through data measurements: temperatures and velocities within the chimney, and their analysis using Excel and MATLAB. The obtained results were compared with those from literature to verify their validity. From this study, it is found that the maximum temperature at the chimney outlet reaches 49.4˚C with an average value of 43.7˚C. Additionally, the heating evolution of the chimney air presents four (04) identical phases in pairs, reflecting the chimney’s operation throughout day. The temperature difference between the outlet and inlet of the chimney reaches a maximum of 17˚C with an average of 12.6˚C. Regarding airflow, the maximum air velocity at the chimney outlet is 0.8 m/s, and the average velocities have consistently been greater than or equal to 0.46 m/s. Thus, it can be concluded that the solar chimney is capable of providing ventilation for the preservation chamber through thermal draft. 展开更多
关键词 Solar chimney Natural Ventilation Thermal Draft AIRFLOW chimney Effect
下载PDF
Chimney支架技术联合All in One技术在经导管主动脉瓣置换术中应用的初步经验
2
作者 宋光远 刘新民 +8 位作者 姚晶 阴赪茜 吴文辉 苑飞 罗太阳 卢志南 常三帅 闫云峰 蒲俊舟 《中国循环杂志》 CSCD 北大核心 2023年第3期312-317,共6页
目的:总结Chimney支架技术联合All in One技术在经导管主动脉瓣置换术(TAVR)中应用的初步经验。方法:收集2021年7月至2022年7月首都医科大学附属北京安贞医院心脏瓣膜病介入中心在TAVR术中联合应用Chimney支架技术和All in One技术的10... 目的:总结Chimney支架技术联合All in One技术在经导管主动脉瓣置换术(TAVR)中应用的初步经验。方法:收集2021年7月至2022年7月首都医科大学附属北京安贞医院心脏瓣膜病介入中心在TAVR术中联合应用Chimney支架技术和All in One技术的10例患者进行回顾性分析,总结临床资料、影像学资料、手术操作、住院和出院随访期间主要不良心脑血管事件的发生情况。结果:10例患者中男性4例,女性6例,平均年龄(76.2±3.9)岁,三叶式主动脉瓣7例,二叶式主动脉瓣3例,术前CT评估均有冠状动脉阻塞危险因素,并且术中球囊预扩张提示冠状动脉阻塞。所有患者均使用一枚药物洗脱支架完成Chimney支架技术,冠状动脉支架置入有8例位于左主干,2例位于右冠状动脉,支架平均直径(3.7±0.3)mm,平均长度(20.6±2.4)mm,在住院及平均随访(7.8±3.7)个月期间,无死亡、心肌梗死、脑卒中等主要不良心脑血管事件发生。结论:TAVR术中Chimney支架技术联合All in One技术安全可行。 展开更多
关键词 chimney支架技术 经导管主动脉瓣置换术 All in One技术 经皮冠状动脉介入治疗
下载PDF
Optimization of a Solar Chimney with a Horizontal Absorber for Building Ventilation:A Case Study
3
作者 El Hadji I Cisse Baye Alioune Ndiogou +2 位作者 Soumaïla Tigampo Ababacar Thiam DorothéAzilinon 《Fluid Dynamics & Materials Processing》 EI 2023年第4期901-910,共10页
A study is conducted to optimize the geometry of a solar chimney equipped with a horizontal absorber in order to improve its performances in relation to the provision of ventilation.The problem is tackled through nume... A study is conducted to optimize the geometry of a solar chimney equipped with a horizontal absorber in order to improve its performances in relation to the provision of ventilation.The problem is tackled through numerical solution of the governing equations for mass,momentum and energy in their complete three-dimensional and unsteady formulation.The numerical framework also includes a turbulence model(k-ε)and a radiant heat transfer(DO)model.Moreover,a Multi-Objective Genetic Algorithm(MOGA)is employed to derive the optimal configuration of the considered solar chimney.It is shown that an air velocity of 0.2 m/s can be obtained.This value is the minimum allowed air velocity according to the ASHRAE’s(American Society of Heating,Refrigerating and Air-Conditioning Engineers)adaptive comfort approach. 展开更多
关键词 Natural ventilation adaptative comfort solar chimney FLUENT MOGA
下载PDF
Microtexture and Distribution of Minerals in Hydrothermal Barite-Silica Chimney from the Franklin Seamount, SW Pacific: Constraints on Mode of Formation 被引量:7
4
作者 Durbar RAY Dalayya KOTA +4 位作者 Pranab DAS L.Surya Prakash V.D.KHEDEKAR Anil L.PAROPKARI Abhay V.MUDHOLKAR 《Acta Geologica Sinica(English Edition)》 SCIE CAS CSCD 2014年第1期213-225,共13页
An extinct hydrothermal barite-silica chimney from the Franklin Seamount of the Woodlark Basin, in the southwestern Pacific Ocean, was investigated for mineral distribution and geochemical composition. Six layers on e... An extinct hydrothermal barite-silica chimney from the Franklin Seamount of the Woodlark Basin, in the southwestern Pacific Ocean, was investigated for mineral distribution and geochemical composition. Six layers on either side of the orifice of a chimney show significant disparity in color, mineral assemblage and major element composition. Electron microscope(SEM) images reveal that the peripheral wall of the chimney is composed of colloform silica, suggesting that incipient precipitation of silica-saturated hydrothermal fluid initiated the development of the chimney wall. Intermediate layers, between the exterior wall and the inner fluid-orifice, dominate with barite and sulfides. Low Sr-to-Ba ratios(SrO/BaO = 0.015–0.017) indicate restricted fluid-seawater mixing, which causes relatively high-temperature formation of the intermediate layers. Whereas the innermost layer bordering the chimney orifice is characterized by more silica and a higher Sr-to-Ba ratio(SrO/BaO = 0.023), could have formed due to a paragenetic shift from a high-temperature active phase to a cooler waning stage of formation. A paragenetic shift is also probably responsible for the change in mineral formation mechanism that resulted in the textural variation of barite and colloform silica developed during different growth phases of this barite-silica chimney. 展开更多
关键词 mineralogy oceanography geochemistry Franklin seamount barite-silica chimney
下载PDF
REE and Sr-Nd isotope characteristics of hydrothermal chimney at Jade area in the Okinawa Trough 被引量:6
5
作者 LIUYanguang MENGXianwei FUYunxia 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2004年第2期287-296,共10页
Hydrothermal chimney is a product of hydrothermal activity on the seabed. Chimney samples dredged from Jade hydrothermal area in Izena depression of the Okinawa Trough, are characterized by relatively enriched light r... Hydrothermal chimney is a product of hydrothermal activity on the seabed. Chimney samples dredged from Jade hydrothermal area in Izena depression of the Okinawa Trough, are characterized by relatively enriched light rare earth elements (LREE) and strongly positive Eu anomalies. 87Sr/86Sr and 143Nd/144Nd of these samples are exactly between those of seawater and of acidic pumice, averaged at 0.708928 and 0.512292, respectively. These characteristics imply that the main source of hydrothermal sulfide at Jade area is possibly the undersurface acidic rocks. The mineralizing mechanism can be summarized as follows: Large amount of mineralized material would be leached out and LREE-enriched hydrothermal solution would be subsequently produced as a result of thermo-chemical exchange reaction between acidic volcanic rocks and heated seawater that penetrated in advance from upper water mass. The spurting out from the seabed and quickly crystallizing in the seawater of hydrothermal solution are responsible for the formation of Cu-Zn sulfide and barite-amorphous SiO2 minerals that are characterized by enriched LREE and positively strong Eu anomalies. 展开更多
关键词 hydrothermal chimney rare earth elements Sr and Nd isotopes
下载PDF
Mineralization of a Proterozoic Sulfide Black Smoker Chimney and Thermophilous Microorganisms in Eastern Hebei,China 被引量:3
6
作者 XIA Xuehui LIAN Wei +2 位作者 YUAN Congjian YAN Fei YUAN Jiazhong 《Acta Geologica Sinica(English Edition)》 SCIE CAS CSCD 2008年第4期858-863,共6页
A sulfide black smoker chimney exists in the Gaobanhe seabed exhalation massive sulfide deposit in the Xingiong-Kuancheng secondary fault basin of the Proterozoic Yaniiao rift trough in Hebei Province, taking the shap... A sulfide black smoker chimney exists in the Gaobanhe seabed exhalation massive sulfide deposit in the Xingiong-Kuancheng secondary fault basin of the Proterozoic Yaniiao rift trough in Hebei Province, taking the shape of mounds, individually about 2-3 cm high. Abundant fossils of thermophilous bacteria and algae in perfect preservation are found in the ore surrounding the black smoker chimney. Scanning electron microscopy (SEM) and molecular biomarker studies on the microorganismai ore fabric show that the microorganism in the sulfide ore is in fact a sedimentary product of probiotic bacteria and algae. In the special food chain based on black smoker chimney at ancient seabed- thermophilous bacteria, the thermophilous bacteria and algae reproduce in large quantity. Intermittently erupting of fluid from the chimney creats conditions for formation of sulfide deposit. In the process of exhalation action of hot fluid, thermophilous bacteria and algae grow and reproduce around the sulfide black smoker chimney, absorbing mineralizing substances brought by the fluid. Massive sulfide deposits are formed in this process of absorption of seabed black smoker chimney exhalation-mineralizing fluid pulsation-thermophilous microorganism. 展开更多
关键词 sulfide black smoker chimney thermophilous microorganisms mineralization Mesoproterozoic
下载PDF
Short-term results in canines of novel stent-graft design for chimney technique in TEVAR 被引量:6
7
作者 Ming Li Chang Shu +2 位作者 Benhao Xiao Dingxiao Liu Weichang Zhang 《Journal of Interventional Medicine》 2020年第3期128-131,共4页
Introduction:Parallel stent-stent grafting is a major endovascular technique used to preserve the supra-aortic branches during thoracic endovascular aortic repair(TEVAR)of aortic pathologies involving the aortic arch.... Introduction:Parallel stent-stent grafting is a major endovascular technique used to preserve the supra-aortic branches during thoracic endovascular aortic repair(TEVAR)of aortic pathologies involving the aortic arch.The short-and mid-term results of this technique are satisfactory;however,endoleak remains a major concern.Thus,here we designed a new chimney stent-graft to decrease the endoleak rate.Aim:To testify the feasibility and safety of the new chimney stent-graft system in a canine model.Material and methods:Six Labrador retrievers were used.Pre-operative data were collected and all operations were performed under general anesthesia.The main and chimney stent-grafts were implanted through the abdominal aorta and left subclavian artery approaches,respectively.Completion digital subtraction angiography(DSA)was performed to confirm the immediate outcomes.All dogs were fed separately for 6 months and sacrificed after aortic angiography.The thoracic aorta and the main and chimney stent-grafts were harvested for histopathologic examination.Results:No complications were found in follow-up DSA.All branch arteries were patent.In?ammatory responses were observed around the stent-grafts in 3 experimental animals,and slight hyperplasia was observed in the surrounding tissues compared with the normal vessels.There was no mural thrombus in the stent,endothelial cells were noted on the inner surface of the stent,and thrombus was formed in the outer skirt and gutter area.The histopathologic examinations revealed similar results to those of gross necropsy observations.Conclusions:This study demonstrated the feasibility and safety of the Longuette stent-graft and the first to report a revised stent-graft specific for chimney technique. 展开更多
关键词 Thoracic endovascular aortic repair chimney technique Canine model In vivo experiment STENT-GRAFT
下载PDF
Experimental investigation of chimney-enhanced natural convection in hexagonal honeycombs 被引量:2
8
作者 Xiaohu Yang Jiaxi Bai +1 位作者 Tianjian Lu Tongbeum Kim 《Theoretical & Applied Mechanics Letters》 CAS 2014年第3期49-54,共6页
The natural convective heat transfer performance of an aluminum hexagonal honeycomb acting as a novel heat sink for LED cooling is experi- mentally investigated. The concept of adding an adiabatic square chimney ex- t... The natural convective heat transfer performance of an aluminum hexagonal honeycomb acting as a novel heat sink for LED cooling is experi- mentally investigated. The concept of adding an adiabatic square chimney ex- tension for heat transfer enhancement is proposed, and the effects of chimney shape, height, and diameter are quantified. The average Nuav of a heated hon- eycomb with straight chimney is significantly higher than that without chimney, and the enhancement increases with increasing chimney height. At a given chim- ney height, honeycombs with divergent chimneys perform better than those with convergent ones. For a fixed divergent angle, the Nuav number increases mono- tonically with increasing chimney height. In contrast, with the convergent angle fixed, there exists an optimal chimney height to achieve maximum heat transfer. 展开更多
关键词 natural convection HONEYCOMB adiabatic chimney experiment
下载PDF
GEOCHEMICAL CHARACTERISTICS OF STABLE ISOTOPES FROM HYDROTHERMAL CHIMNEYS IN THE MARIANA TROUGH, WEST PACIFIC OCEAN 被引量:1
9
作者 吴世迎 张道建 +2 位作者 王揆洋 陈成业 白黎明 《Chinese Journal of Oceanology and Limnology》 SCIE CAS CSCD 2000年第4期378-384,共7页
The determination of the stable isotopes, δD, δ18 and δ30, values from hydrothermal chimneys in the Mariana Trough, the West Pacific, indicated that the pure siliceous chimneys with gentle data variation were forme... The determination of the stable isotopes, δD, δ18 and δ30, values from hydrothermal chimneys in the Mariana Trough, the West Pacific, indicated that the pure siliceous chimneys with gentle data variation were formed in low temperature environment. It reflects that the sea-floor hydrothermal activity of the Mariana Trough is primarily low-to-medium temperature hydrothermal eruption, and those chimneys with strong data variation and containing pyrite were formed in higher temperature environment. Key words Mariana Trough - stable isotope - geochemistry - hydrothermal chimney - genetic type Project 49876016 supported by NSFC. 展开更多
关键词 Mariana Trough stable isotope geochemistry hydrothermal chimney genetic type
原文传递
Finite Element Analysis and Linear Regression of Maximum Temperature for Inner Wall of Chimney Foundation 被引量:2
10
作者 ZHANG Yu-mei SONG Yu-pu +1 位作者 ZHAO Yun-fei ZHANG Ye-min 《Journal of China University of Mining and Technology》 EI 2005年第3期234-240,共7页
The uniform design method was adopted and the twenty-four groups of different geometric and physical pa-rameters were chosen. The finite element model was built. Comparisons between the simulation results and the test... The uniform design method was adopted and the twenty-four groups of different geometric and physical pa-rameters were chosen. The finite element model was built. Comparisons between the simulation results and the test re-sults prove that the simulation results are correct. The distribution of the temperature field of the chimney foundationwas analyzed. The multivariate linear regression of the hightest tomperature was performed on the inner wall of thechimney foundation by the numerical calculated results. The fitting property of the highest temperature with six influ-ence factors was obtained. A simple method for the calculation of the temperature field of the chimney foundation wasprovided. 展开更多
关键词 chimney foundation temperature field nonlinear finite element analysis linear regression
下载PDF
Performance Investigation of the Solar Chimney Power Plants Heater Case Study in Aswan, Egypt 被引量:1
11
作者 Magdy Bassily Hanna Tarek Abdel-Malak Mekhail +2 位作者 Omar Mohamed Dahab Mohamed Fathy Cidek Esmail Ahmed Rekaby Abdel-Rahman 《Journal of Power and Energy Engineering》 2016年第10期39-60,共23页
Solar collector is a thermal device that uses the heated air in the power generation and many engineering applications. The purpose of the present work is to study the performance and temperature distribution for the ... Solar collector is a thermal device that uses the heated air in the power generation and many engineering applications. The purpose of the present work is to study the performance and temperature distribution for the solar collector which uses heated air in solar chimney power generation that it consist of three parts, a turbine-generator unit which is used in the generation of electric energy, and cylindrical chimney is fixed vertically and finally a solar collector under the climatic conditions of Egypt-Aswan is studied. This site is specified as the hottest site because the nearest of this location from the Tropic of cancer. Experiments are performed in ten summer days of May and June 2015 with different solar radiations and clarity of the sky. Hourly values of global solar radiation and some meteorological data (temperature, pressure, velocity, etc.) for measuring days are obtained by measuring devices. Inlet and outlet temperatures of air from a solar collector and velocity at junction region. In this work, attempt has been made to present the effect of environmental factors such as ambient temperature, the clarity of the sky and solar radiation on the performance of solar collector. The temperature of the base and the cover of the solar collector, the variation of solar radiation, solar collector efficiency, heat transfer coefficient, the velocity at the junction region between the chimney base, the outlet of the solar collector and temperature distribution along the air heater are discussed. A prediction for the results of the solar collector were performed by using developed theoretical model was made by this study which is based on the previous works. The numerical study has used a commercial code CFX, ANSYS 16.1 to simulate the flow through the collector. The study show that the outlet air temperatures from the solar collector and the velocity at the junction are depending on the climate condition such as ambient temperature and solar radiation, the differences in air temperature at the solar collector ranging between 8° - 24°. It is concluded that the theoretical model is basically valid for the system under study, and theCFD simulation can be used conveniently to predict the performance of the system, the comparison between them and experimental result shows a good agreement. 展开更多
关键词 Solar chimney Solar Collector Natural Convection Computational Fluid Dynamic
下载PDF
童音凄切,催人泪下——诗歌The Chimney Sweeper赏析
12
作者 William Blake 王晨爽 《大学英语》 2003年第3期49-,共1页
关键词 The chimney Sweeper
下载PDF
Experimental and Numerical Investigation of the Solar Chimney Power Plant’s Turbine 被引量:1
13
作者 Magdy Bassily Hanna Tarek Abdel-Malak Mekhail +2 位作者 Omar Mohamed Dahab Mohamed Fathy Cidek Esmail Ahmed Rekaby Abdel-Rahman 《Open Journal of Fluid Dynamics》 2016年第4期332-342,共12页
The solar chimney power plant is a relatively new electricity generation concept, based on renewable energy, combining the greenhouse effect with the chimney suction. The solar chimney powerplant consists of three par... The solar chimney power plant is a relatively new electricity generation concept, based on renewable energy, combining the greenhouse effect with the chimney suction. The solar chimney powerplant consists of three parts, the solar collector, the chimney and the turbine generator unit, of which the study was focused on the later part. To evaluate the turbine performance inside the solar chimney powerplant, experimental system was constructed in Aswan, Egypt that has a metrological site (23°58'N and 32°47'E) occurs. The system was constructed to evaluate the performance of the solar chimney turbine and power generation characteristic in the hottest site where Aswan is located at the nearest of the Tropic of Cancer at the summer season. Velocity, electric power generation and the turbine efficiency are studying in this work. The numerical analyses were performed by using a commercial code CFX, ANSYS 16.1 to simulate the flow through the turbine and overall system. The study shows that the range of power generated (1.2 W - 4.4 W). It can be estimated, according to the results, the variation trend in pressure drops with the turbine rotation speed increase with small differences when the turbine rotation speed surpasses 1800 rpm with average efficiency of 57%. It is concluded that the theoretical model is basically valid for the system under study, and the CFD simulation can be used conveniently to predict the performance of the system, the comparison between them and experimental result shows a good agreement. 展开更多
关键词 Solar chimney Natural Convection Turbine Modeling CFD
下载PDF
Chimney Effect Assessment of the Double-skin Facade
14
作者 QIU Zhong-zhu1,LI Peng2,CHOW Tin-tai3,REN Jian-xing1,WANG Wen-huan1(1.School of Energy & Environment Engineering,Shanghai University of Electric Power,Shanghai 20090,China 2.School of Mechanical Engineering,Tongji University,Shanghai 200092,China 3.Division of Building Science & Technology,City University of Hong Kong,Hong Kong SAR,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期146-150,共5页
The mathematic model of heat transfer through ventilated double glazing was verified with the measured data,which were from a test chamber equipped with glass face temperature,solar radiation,ambient temperature,and w... The mathematic model of heat transfer through ventilated double glazing was verified with the measured data,which were from a test chamber equipped with glass face temperature,solar radiation,ambient temperature,and wind speed measurement facility.After the model validation,the double-skin facade assessment was carried out through simulation with ESP-r software integrating thermal simulation and air low net work module.The air flow situation in the air gap was analyzed on the basis of the hourly air velocity simulation data within typical winter week,summer week,spring week and autumn week.The differences of chimney effect in different seasons were discussed,and the thermal loads resulted from the ventilated and unventilated double skin facade were presented. 展开更多
关键词 chimney EFFECT ASSESSMENT double-skin FACADE
下载PDF
The contribution of trace elements from seawater to chimneys:a case study of the native sulfur chimneys in the sea area off Kueishantao,northeast of Taiwan Island
15
作者 刘长华 汪小妹 +2 位作者 靳新娣 曾志刚 陈镇东 《Chinese Journal of Oceanology and Limnology》 SCIE CAS CSCD 2009年第1期162-171,共10页
Hydrothermal fuid containing abundant matter erupts from seafloor, meets ambient cold seawater and forms chimneys. So the main matter origins of chimneys are seawater and matter which are taken by hydrothermal fluid f... Hydrothermal fuid containing abundant matter erupts from seafloor, meets ambient cold seawater and forms chimneys. So the main matter origins of chimneys are seawater and matter which are taken by hydrothermal fluid from deep reservoir. However, because of seawater's little contribution to the forming of chimneys, it is usually covered by the abundant matter which is taken by hydrothermal fluid. Therefore, chimneys formed in ordinary deep elements, cannot be used to study the seawater's seawater hydrothermal activity, containing complex contribution to their formation. While the native sulfur chimneys, formed by hydrothermal activity near the sea area off Kueishantao, are single sulfur composition (over 99%), and within chimneys distinct layers are seen. Different layers were sampled for trace element determination, with Inductively Coupled Plasma Mass Spectrometry (ICP-MS). By analyzing the data, we consider C-layer (secondary inner-layer) as the framework layer of the chimney which formed early (Fig.4), and its trace elements derive from hydrothermal fluid. While the trace elements within A, B, D layers have undergone later alteration. A, B layers are affected by seawater and D layer by hydrothermal fluid. The increase of trace elements of A and B layers was calculated using C layer as background. Based on the known typical volume of chimneys of the near sea area off Kueishantao, we calculated the volume of seawater that contributed trace element to chimneys formation to be about 6.37×10^4 L. This simple quantified estimate may help us better understand the seafloor hydrothermal activity and chimneys. 展开更多
关键词 seafloor hydrothermal activity chimney native sulfur trace element
原文传递
Effects of nuclear chimney on climate
16
作者 Gao Suhua, Ding Yihui, Pan Yaru and Zhang QingchenAcademy of Meteorological Science State Meteorological Administration,Beijing 100081,China 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 1990年第4期111-116,共6页
In this paper, according to the data from several single nuclear explosion experiments of an equivalent to magnitude of million tons, and combined with meteorological data, their effects on the regional climate nave b... In this paper, according to the data from several single nuclear explosion experiments of an equivalent to magnitude of million tons, and combined with meteorological data, their effects on the regional climate nave been analysed. 展开更多
关键词 nuclear chimney nuclear explosion temperature change.
下载PDF
Kinetic Energy Recovery from the Chimney Flue Gases Using Ducted Turbine System
17
作者 Harjeet S.Mann Pradeep K.Singh 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2017年第2期472-482,共11页
An innovative idea of extracting kinetic energy from man-made wind resources using ducted turbine system for on-site power generation is introduced in this paper. A horizontal axis ducted turbine is attached to the to... An innovative idea of extracting kinetic energy from man-made wind resources using ducted turbine system for on-site power generation is introduced in this paper. A horizontal axis ducted turbine is attached to the top of the chimney to harness the kinetic energy of flue gases for producing electricity. The turbine system is positioned beyond the chimney outlet, to avoid any negative impact on the chimney performance. The convergentdivergent duct causes increase in the flue gas velocity and hence enhances the performance of the turbine. It also acts as a safety cover to the energy recovery system. The results from the CFD based simulation analysis indicate that sig- nificant power 34 kW can be harnessed from the chimney exhaust. The effect of airfoils NACA4412 and NACA4416 and the diffuser angle on the power extraction by the energy recovery system using a 6-bladed ducted turbine has been studied with the CFD simulation. It is observed that the average flue gas velocity in the duct section at the throat is approximately twice that of the inlet velocity, whereas maximum velocity achieved is 2.6 times the inlet velocity. The simulated results show that about power may be extracted from the chimney flue gases of 660 MW power plant. The system can be retrofitted to existing chimneys of thermal power plants, refineries and other industries. 展开更多
关键词 chimney flue gases Energy recovery system ·Kinetic energy Ducted turbine CFD
下载PDF
Thermal Analyses of Combined Utilization Process of Seawater by Solar Chimney
18
作者 王一平 方振雷 朱丽 《Transactions of Tianjin University》 EI CAS 2009年第6期393-399,共7页
It is promising to simultaneously develop multiple products through the combined utilization of seawater by solar chimney technology. A small scale experimental system was set up. The collector temperature, the seawat... It is promising to simultaneously develop multiple products through the combined utilization of seawater by solar chimney technology. A small scale experimental system was set up. The collector temperature, the seawater temperature, and the temperature and humidity of the airflow under the collector were measured. Thermal network analysis of the system was carried out. The results show that the airflow is nearly saturated at the entrance of the chimney, and the mean dry-bulb and wet-bulb temperatures of the airflow have increased by 8.4 ℃ and 9.6 ℃, respectively. The radiation heat transfer between the collector and the sky is the biggest heat loss in the system, which is up to 29.1% on average of the solar energy. However, the water evaporation heat is about 23.6% on average of the solar energy. To reduce the heat loss and enhance the water evaporation, it is necessary to reduce the emissivity and thermal conductivity of the collector and increase the evaporation areas. 展开更多
关键词 solar chimney combined utilization of seawater thermal network enhanced evaporation
下载PDF
A preliminary study on microtextures,structures and mineralizing processes of hydrothermal chimneys in Mariana Trough
19
作者 Zhang Deyu 《Acta Oceanologica Sinica》 SCIE CAS CSCD 1996年第4期469-483,485-492,共24页
Microtextures and struetures of 9 hydrothermal chimneys sampled on the small spreading ridge Of the Mari ana Trough during SONNE Cruise 57 (SO57) and 69 (SO69) in 1988 and 1990 were studied by means of scanning elec... Microtextures and struetures of 9 hydrothermal chimneys sampled on the small spreading ridge Of the Mari ana Trough during SONNE Cruise 57 (SO57) and 69 (SO69) in 1988 and 1990 were studied by means of scanning electron microscope. The results reveal that the two types of chimneys from the Mariana Trough. the 'silicic chimneys' containing Fe sulfide and the pure 'silica chimneys' without sulfide, vary distinctly not only in mineral and chemical compositions, but also in microtextures and structures. The silicic chimneys generally show three major types of microtextures.The inside of the chimneys is dominated by holocrystalline or semicrystalline idiomorphic and hypidiomorphic granular textures and the outwall by amorphous colloidal texture. In some of the silicic chimneys relict texture is observed. However,the pure silica chimneys show chiefly amorphous colloidal texture from the inside to the outwall. Microstructurally. theinside of the silicic chimneys is dominated by a 'silica-covering' structure and a 'voidfilling' structure, and the outwall by a chain-like or three-dimentional chain-network structure built up by individual opal globules, whereas the pure silica chimneys are mainly three-dimentional chain-network and the dense silica bands in structure. These variations suggest that not only mineralizing conditions but also processes differ distinctly during the formation of the two types of chimneys, and that hydrothermal mineralization in the Mariana Trough shows a multistage or multieplsodical nature. 展开更多
关键词 The Mariana Trough hydrothermal chimneys microtextures and structures mineralizing processes
下载PDF
Research progress on integrated solar chimney system for freshwater production
20
作者 Lu Zuo Ling Ding +3 位作者 Yue Yuan Zihan Liu Ning Qu Pengzhan Dai 《Global Energy Interconnection》 2019年第3期214-223,共10页
Under dual crisis of energy and freshwater,solar chimney technology has been widely applied in freshwater production in recent years.According to different access to freshwater,the research progress of the coupling of... Under dual crisis of energy and freshwater,solar chimney technology has been widely applied in freshwater production in recent years.According to different access to freshwater,the research progress of the coupling of solar chimney with other technologies such as solar desalination technology,humidification and humidification desalination technology,as well as integrated systems that obtain freshwater output from ambient air were summarized respectively.The integrated solar chimney system can realize multi-target production of electricity and freshwater,and improve the comprehensive utilization of solar energy,which provides new possibility for the site selection and small-scale construction of solar chimney power plant in the future.It has certain practical significance and is conducive to the promotion and application of solar chimney technology. 展开更多
关键词 Solar chimney DESALINATION MULTI-TARGET FRESHWATER OUTPUT
下载PDF
上一页 1 2 3 下一页 到第
使用帮助 返回顶部