期刊文献+
共找到1,236篇文章
< 1 2 62 >
每页显示 20 50 100
Oxidation of Partially Hydrolyzed Polyacrylamide from Polymer Flooding Processes Using Fenton Reagents 被引量:1
1
作者 Li Jinlian Wang Jia +2 位作者 Liu Hongyan Wu HongJun Zhang Yongjun 《China Petroleum Processing & Petrochemical Technology》 SCIE CAS CSCD 2023年第4期86-92,共7页
The degradation of partially hydrolyzed polyacrylamide(HPAM) found in alkaline/surfactant/polymer flooding sewage was investigated using Fenton-type reagents. Different Fenton reagent treatments for HPAM degradation w... The degradation of partially hydrolyzed polyacrylamide(HPAM) found in alkaline/surfactant/polymer flooding sewage was investigated using Fenton-type reagents. Different Fenton reagent treatments for HPAM degradation were compared. The effects of pH, hydrogen peroxide(H_(2)O_(2)), ferrous ion(Fe^(2+)), and tartaric ion(C_(4)H_(4)O_(6)^(2-)) concentrations were studied. The degradation reaction occurred within a wide range of pH(3–9). The HPAM degradation performance of photo-Fenton processes using solar light and UV were compared with that of the Fenton process. The degradation rate was found to be strongly dependent on the H_(2)O_(2)/Fe^(2+)/C_(4)H_(4)O_(6)^(2-)molar ratio. The HPAM degradation efficiency was 90%, and the chemical oxygen demand removal efficiency was 85%. HPAM could be degraded into a compound with a lower molecular weight, but it was difficult to achieve complete mineralization to CO_(2). The presence of intermediate products hindered further oxidation in the Fenton process. 展开更多
关键词 PHOTODEGRADATION UV fenton reagent partially hydrolyzed polyacrylamide
下载PDF
Degradation of 4-Chlorophenol Solution by Synergetic Effect of Dual-frequency Ultrasound with Fenton Reagent 被引量:8
2
作者 赵德明 徐新华 +1 位作者 雷乐成 汪大翚 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2005年第2期204-210,共7页
4-Chlorophenol (4-CP) solution was treated by dual-frequency ultrasound inconjunction with Fenton reagent, and obvious improvement in the 4-CP degradation rate was observedin this advanced oxidation process. Experimen... 4-Chlorophenol (4-CP) solution was treated by dual-frequency ultrasound inconjunction with Fenton reagent, and obvious improvement in the 4-CP degradation rate was observedin this advanced oxidation process. Experimental results showed that ultrasonic intensity,saturating gas and pH value affected greatly the 4-CP removal rate. Among four different saturatinggases (Ar, O_2, air and N_2), 4-CP degradation with Ar-saturated solution was the best. However, inthe view of practical wastewater treatment, using oxygen as the saturating gas would be moreeconomical. The addition of Fenton reagent followed the first-order kinetics and increased the 4-CPdegradation rate. The 4-CP removal rate increased by around 126% within 15 min treatment. Thesynergetic effect of dual-frequency ultrasound with Fenton reagent on 4-CP degradation was obviouslyobserved. 展开更多
关键词 dual-frequency ultrasound with fenton reagent advanced oxidation process synergetic effect
下载PDF
Catalytic oxidation degradation of phenol in wastewater by heterogeneous Fenton reagent 被引量:2
3
作者 万家峰 《Journal of Chongqing University》 CAS 2011年第4期147-152,共6页
Heterogeneous Fenton reagent, as a strong oxidizer, has been used widely in the treatment ofwastewater. We prepared Fe2O3/γ-Al2O3 catalyst by impregnation method and characterized it by powder X-ray diffraction (XRD... Heterogeneous Fenton reagent, as a strong oxidizer, has been used widely in the treatment ofwastewater. We prepared Fe2O3/γ-Al2O3 catalyst by impregnation method and characterized it by powder X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM). Test results show that Fe203 crystal was compounded on the γ-Al2O3 carder. We tested and optimized Fe203/γ-Al2O3 /H2O2 and Fe2O3/γ-Al2O3 /H2O2/UV processes to remediate organic material of phenol, using phenol solution with an in. itial concentration of 250 mg/L as a representative of phenolic industrial Wastewater. The preparation conditions were optimized based on performance of Fe2Oa/γ-Al2O3 catalyst and the processes to degrade phenol in aqueous environments. The experimental results showed that the phenol removal perfomance with Fe2O3/γ-Al2O3 /H2O2/UV was more complete than with Fe2O3/γ-Al2O3 /H2O2 and degradation rate of phenol reached 89.4% and 94.7% respectively after reaction for2 h. 展开更多
关键词 heterogeneous catalysis fenton reagent Fe2O3/γ-Al2O3 PHENOL
下载PDF
Fenton试剂法在工业有机废水中的处理研究 被引量:1
4
作者 姜维涛 《黑龙江环境通报》 2024年第5期27-29,共3页
本文针对工业有机废水处理中的问题,探讨了Fenton试剂法在工业有机废水处理中的应用和处理策略。首先,分析了工业有机废水处理中的挑战,包括废水中有机物浓度高、毒性较强、处理难度大等问题。其次,介绍了Fenton试剂法的原理及特点。最... 本文针对工业有机废水处理中的问题,探讨了Fenton试剂法在工业有机废水处理中的应用和处理策略。首先,分析了工业有机废水处理中的挑战,包括废水中有机物浓度高、毒性较强、处理难度大等问题。其次,介绍了Fenton试剂法的原理及特点。最后,探讨了Fenton试剂法在处理工业有机废水时的优化策略,以期为实际工程应用提供参考。 展开更多
关键词 工业有机废水 fenton试剂 处理策略
下载PDF
芬顿试剂(Fenton's reagent法降解对苯二酚和工业废水 被引量:4
5
作者 常文贵 谢红璐 《渤海大学学报(自然科学版)》 CAS 2004年第1期15-18,共4页
可溶性亚铁盐和H2O2的组合称为芬顿试剂(Fenton’s reagent),是一种氧化能力很强的氧化剂,常用于废水的净化处理。本文以对苯二酚为代表物,探讨用Fenton试剂氧化的反应条件,并用最佳的实验条件处理工业废水,90分钟工业废水的COD去除率可... 可溶性亚铁盐和H2O2的组合称为芬顿试剂(Fenton’s reagent),是一种氧化能力很强的氧化剂,常用于废水的净化处理。本文以对苯二酚为代表物,探讨用Fenton试剂氧化的反应条件,并用最佳的实验条件处理工业废水,90分钟工业废水的COD去除率可达71.6%。 展开更多
关键词 芬顿试剂 羟基自由基 废水处理 COD去除率 苯二酚 工业废水
下载PDF
Exploitation of Fenton and Fenton-like reagents as alternative conditioners for alum sludge conditioning 被引量:27
6
作者 Maha A. Tony Y. Q. Zhao Aghareed M. Tayeb 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2009年第1期101-105,共5页
The use of Fenton's reagent (Fe^2+/H2O2) and Fenton-like reagents containing transition metals of Cu(Ⅱ), Zn(Ⅱ), Co(Ⅱ), and Mn(Ⅱ) for an alum sludge conditioning to improve its dewaterability was invest... The use of Fenton's reagent (Fe^2+/H2O2) and Fenton-like reagents containing transition metals of Cu(Ⅱ), Zn(Ⅱ), Co(Ⅱ), and Mn(Ⅱ) for an alum sludge conditioning to improve its dewaterability was investigated. The results obtained were compared with those obtained from conditioning the same alum sludge using cationic and anionic polymers. Experimental results show that Fenton's reagent was the best among the Fenton and Fenton-like reagents for the alum sludge conditioning. A considerable effectiveness of capillary suction time (CST) reduction efficiency of 47% can be achieved under test conditions of Fe^2+/H2O2 = 20/125 mg/g DS (dry solid) and pH 6.0. The observation of floc-like particles after Fenton's reagent conditioning of alum sludge suggested that the mechanism of Fenton's reagent conditioning was different from that of polymer conditioning. In spite of the lower efficiency in the CST reduction of Fenton's reagent in alum sludge conditioning compared to that of polymer conditioning, Fenton's reagent offers a more environmentally safe option. Tiffs study provided an example of proactive treatment engineering, which is aimed at seeking a safe alternative to the use of polymers in sludge conditioning towards achieving a more sustainable sludge management strategy. 展开更多
关键词 alum sludge CONDITIONING fenton and fenton-like reagents organic polymers cost estimate
下载PDF
Degradation of polyvinyl-alcohol wastewater by Fenton’s reagent: Condition optimization and enhanced biodegradability 被引量:12
7
作者 肖羽堂 许双双 李志花 《Journal of Central South University》 SCIE EI CAS 2011年第1期96-100,共5页
The pretreatment of refractory polyvinyl-alcohol (PVA) wastewater with low value of CODcr by Fenton's reagent was investigated to enhance the biodegradabilily. The effects of operating conditions such as pH of the ... The pretreatment of refractory polyvinyl-alcohol (PVA) wastewater with low value of CODcr by Fenton's reagent was investigated to enhance the biodegradabilily. The effects of operating conditions such as pH of the solution, Fe2+ dosage, H2O2 dosage, reaction time and initial PVA concentration on the removal efficiency of CODCr were discussed. It is demonstrated that the optimum value of pH for removal of CODcr is 5 and the most suitable dosages of H2O2 (2%) and FeSO4 (10 mg/L) are 5% and 8.0%, respectively. When the initial CODcr value of the PVA water is 760 mg/L, the favorable reaction time is 110 min. Under these optimum conditions, the removal ratio of CODcr is 58.6% 61.4%, and the value of biodegradability (CODB/CODcr) increases markedly from 8.9% 9.7% to 62.6% 68.3%. 展开更多
关键词 fenton's reagent POLYVINYL-ALCOHOL PRETREATMENT BIODEGRADABILITY
下载PDF
Treatment of Wastewater Containing RDX by Fenton's Reagent 被引量:3
8
作者 徐航 张东翔 徐文国 《Defence Technology(防务技术)》 SCIE EI CAS 2008年第1期18-21,共4页
Fenton's reagent was employed to treat the wastewater containing RDX.The effects of FeSO4 concentration,H2O2 concentration,pH value,reaction time,temperature and initial COD of wastewater on residual COD of wastew... Fenton's reagent was employed to treat the wastewater containing RDX.The effects of FeSO4 concentration,H2O2 concentration,pH value,reaction time,temperature and initial COD of wastewater on residual COD of wastewater were investigated.The results show that the optimum FeSO4 concentration and pH are 700 mg/L and 2.5,respectively,and the residual COD of wastewater decreases with the rise in H2O2 concentration,but increases with the rise in temperature.After Fenton's reagent treatment,the initial COD of less than 874 mg/L wastewater can meet effluent standard.Under conditions of 100 mg/L H2O2,437 mg/L initial COD and 15 ℃ temperature,the lowest residual COD is obtained at 83.80 mg/L in 5 min. 展开更多
关键词 氧化加工 锌基试剂 RDX 污水处理
下载PDF
Degradation of Silicone Rubbers in Fenton's Reagents
9
作者 吴凡 李克 +4 位作者 ZHANG Qinglian ZHANG Haining CHEN Yanan PAN Mu YAN Xinping 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2018年第4期793-796,共4页
Gaskets are applied in PEMFCs(proton exchange membrane fuel cells) to keep reactant gases and liquid within their respective regions, which are of great significance for the both sealing and electrochemical performa... Gaskets are applied in PEMFCs(proton exchange membrane fuel cells) to keep reactant gases and liquid within their respective regions, which are of great significance for the both sealing and electrochemical performance of fuel cells during the long-term operation. In this study, the degradation of silicone rubbers, often selected as seals in PEMFCs, in Fenton's reagents with different H_2O_2 concentrations was investigated. The changes in chemical properties, mechanical behavior and surface morphology of the samples were studied before and after exposure to the test environment over time. It is found that increasing H_2O_2 concentration will degrade the rubbers more severely. The experimental results elucidate the degradation mechanism of silicone rubbers in Fenton's reagents and the influence of H_2O_2 in the degradation process. 展开更多
关键词 silicone rubbers PEMFCS SEAL DEGRADATION fenton's reagents
原文传递
Chromo-chemodosimetric detection for Fe^(2+) by Fenton reagent-induced chromophore-decolorizing of halogenated phenolsulfonphthalein derivatives
10
作者 ZHENG Kuan,LAI ChengYue,HE LiPing & LI Fang Key Laboratory of Green Chemistry and Technology,Ministry of Education College of Chemistry,Sichuan University,Chengdu 610064,China 《Science China Chemistry》 SCIE EI CAS 2010年第6期1398-1405,共8页
A commercially-available sulfonphthalein derivative was demonstrated to be a chemodosimeter for Fe2+ and its sensing behavior was further investigated by UV-vis spectroscopy in aqueous media under the optimum conditio... A commercially-available sulfonphthalein derivative was demonstrated to be a chemodosimeter for Fe2+ and its sensing behavior was further investigated by UV-vis spectroscopy in aqueous media under the optimum conditions.In the presence of chlorophenol red (CPR) and H2O2,the absorption maximum at 435 nm decreased upon addition of Fe2+,resulting in a significant color change of the CPR solution from yellow to colorless.The chemosensor system did not show significant responses to a series of other metal ions including Al3+,Zn2+,Cd2+,Hg2+,Mn2+,Co2+,Fe3+,Ni2+,Cu2+,La3+,Ce4+,Th4+,Pd2+,Pb2+,Sb3+,Cr3+,Au3+,Ag+,Nd3+,Sm3+,alkali and alkaline earth metal cations,allowing for highly selective naked-eye detection of Fe2+.Quantitative analysis was carried out kinetically for practicable the Fe2+ assay when either fixed time method or the initial rate method was applied.When the detecting time was set,the decrease of absorbance signal was linear with Fe2+ concentration in the range of 0 to 7.50 × 10-5 mol L-1 and the regression equation was ΔA = 0.00759 + 0.00593CFe with a correlation coefficient r = 0.9953.The chemodosimetric system has employed an irreversible Fenton reagent-promoted oxidation of the CPR free chromophore and the hydroxyl radicals were generated in the presence of both Fe2+ and hydrogen peroxide.The mechanistic interpretation of the signaling process was partially confirmed by the radical scavenging experiment and the FT-IR analysis of the intermediates formed at different reaction periods. 展开更多
关键词 COLORIMETRIC chemosensor FERROUS ion sulfonphthalein fenton reagent
原文传递
Fenton试剂法对苯系物的同步控制研究
11
作者 谢奕标 《广州化工》 CAS 2023年第10期51-54,78,共5页
组建Fenton试剂处理装置,利用有机气体发生装置同时产生四种苯系物,研究表明Fenton试剂对苯、甲苯、乙苯和对二甲苯的去除过程符合一级反应动力学模式,对苯系物同步降解速率大小为:对二甲苯>苯>甲苯>乙苯;过低或过度的pH值均... 组建Fenton试剂处理装置,利用有机气体发生装置同时产生四种苯系物,研究表明Fenton试剂对苯、甲苯、乙苯和对二甲苯的去除过程符合一级反应动力学模式,对苯系物同步降解速率大小为:对二甲苯>苯>甲苯>乙苯;过低或过度的pH值均不利于苯系物的去除,在实验条件下最佳初始pH值为2~3、适宜的反应温度为40~50℃、在H_(2) O_(2) /Fe^(2+)比例4~6之间时,甲苯、乙苯、苯、对二甲苯的去除率最高。 展开更多
关键词 fenton试剂 苯系物 去除率
下载PDF
混凝法及氧化法预处理西药废水效果比较
12
作者 张丽 张欣 《西华师范大学学报(自然科学版)》 2024年第6期606-612,共7页
某制药企业排放的西药废水COD浓度较高,可生化性一般,不能直接采用生物法处理,为达到与中药废水混合处理的条件,分别对其开展化学混凝法和Fenton试剂氧化法预处理研究,并对2种方法的处理效果进行比对分析。在化学混凝法中选用6种常见混... 某制药企业排放的西药废水COD浓度较高,可生化性一般,不能直接采用生物法处理,为达到与中药废水混合处理的条件,分别对其开展化学混凝法和Fenton试剂氧化法预处理研究,并对2种方法的处理效果进行比对分析。在化学混凝法中选用6种常见混凝剂,探讨不同混凝剂的最佳pH值以及混凝剂的投加量对COD去除率的影响,研究表明6种混凝剂中聚合氯化铝(PAC)的混凝效果最好;当PAC与絮凝剂聚丙烯酰胺(PAM)复合处理时,效果更优,COD平均去除率可达到88.09%,出水可生化性也提高到了0.35,可与中药废水混合处理。采用现制Fenton试剂氧化处理时,最佳氧化pH值为4,影响因素中FeSO_(4)投加量对氧化结果的影响最大,在设计的9组正交实验中,COD最大去除率仅为72.64%,且出水可生化性降到0.11,需进一步研究中西药废水混合处理比例。从实验处理效果及后期处理难度比较分析,化学混凝法更适合该企业西药废水的预处理。 展开更多
关键词 西药废水 化学混凝法 混凝剂 fenton试剂
下载PDF
化工有机废水的净化及水质成分分析实验综述报告
13
作者 荣俊锋 刘瑾琳 +2 位作者 韩家林 李新月 兰青青 《安徽化工》 CAS 2024年第1期180-183,共4页
采用低温等离子体(NTP)和Fenton氧化分别对DMP废水进行降解。通过实验研究了最佳处理条件,将两种工艺进行组合,研究组合工艺以及组合工艺中每一种方法的先后顺序对处理结果的影响。学生通过小组协作,设计参数梯度,研究因素对废水处理结... 采用低温等离子体(NTP)和Fenton氧化分别对DMP废水进行降解。通过实验研究了最佳处理条件,将两种工艺进行组合,研究组合工艺以及组合工艺中每一种方法的先后顺序对处理结果的影响。学生通过小组协作,设计参数梯度,研究因素对废水处理结果的影响,达到了综合训练的目的。可为开设综合设计性的专业实验提供参考。 展开更多
关键词 低温等离子体 fenton试剂 小组协作 综合设计性实验
下载PDF
Fenton试剂处理废水中各影响因子的作用机制 被引量:558
14
作者 陈传好 谢波 +2 位作者 任源 吴超飞 韦朝海 《环境科学》 EI CAS CSCD 北大核心 2000年第3期93-96,共4页
以洗胶废水为研究对象初步研究了 Fenton试剂处理有毒有机废水时各影响因子的作用机制 ,通过正交实验确定了 Fen-ton反应各种影响因子的最佳操作条件为 :[H2 O2 ]=0 .2 mol· L- 1、[Fe2 +]=40 mmol· L- 1、反应温度 85℃ ,反... 以洗胶废水为研究对象初步研究了 Fenton试剂处理有毒有机废水时各影响因子的作用机制 ,通过正交实验确定了 Fen-ton反应各种影响因子的最佳操作条件为 :[H2 O2 ]=0 .2 mol· L- 1、[Fe2 +]=40 mmol· L- 1、反应温度 85℃ ,反应时间 60 min、反应体系的 p H值为 3左右 .此条件下废水 COD的去除率普遍大于 80 % .试验发现紫外光和配体络合物可提高 Fenton试剂对有机物的降解能力 .在各影响因子与 COD去除率的关系曲线基础上 ,分析了混合废水中各影响因子的作用机理和综合反应机理的关键及控制步骤 ,提出了改进的思路 . 展开更多
关键词 fenton试剂 羟基自由基 废水处理 洗胶废水
下载PDF
Fenton试剂催化氧化降解含硝基苯废水的特性 被引量:81
15
作者 韦朝海 陈传好 +3 位作者 王刚 任源 吴超飞 吴海珍 《环境科学》 EI CAS CSCD 北大核心 2001年第5期60-64,共5页
探讨不同氧化剂和催化剂浓度下Fenton试剂氧化降解硝基苯的作用规律 ,用一元线性回归方程对不同氧化降解时间后硝基苯的相对残余浓度对反应时间的相关性进行了定量分析 ,结果发现硝基苯的Fenton试剂氧化降解符合一级反应动力学模式 ,通... 探讨不同氧化剂和催化剂浓度下Fenton试剂氧化降解硝基苯的作用规律 ,用一元线性回归方程对不同氧化降解时间后硝基苯的相对残余浓度对反应时间的相关性进行了定量分析 ,结果发现硝基苯的Fenton试剂氧化降解符合一级反应动力学模式 ,通过回归求出了各反应条件下的一级速率常数 .实验中还发现以Fenton反应过程中产生的铁离子的复合物代替Fe2 +作为催化剂时Fenton反应不仅取得了较高的催化反应速率和降解效率 ,而且对硝基苯具有明显的专属性 ,硝基苯的降解速率可由原来的 1 7 4 8mg/(L·min)提高到 71 2 2mg/(L·min) ,反应 5min的硝基苯去除率由 9 74 %提高到 91 79% .用人造沸石为载体吸附该物质制成的非均相催化剂同样具有良好的催化性能 .另外 ,在体系中引入紫外光可以促进废水中CODCr的进一步降解 。 展开更多
关键词 fenton试剂 硝基苯废水 催化氧化 动力学 UV催化 废水处理 降解 特性
下载PDF
Fenton试剂的氧化作用机理及其应用 被引量:107
16
作者 陈胜兵 何少华 +1 位作者 娄金生 谢水波 《环境科学与技术》 CAS CSCD 2004年第3期105-107,共3页
探讨了Fenton试剂(包括标准Fenton试剂、改性Fenton试剂、光—Fenton试剂、电—Fenton试剂及配体—Fenton试剂)降解有机物的作用机理,同时总结了Fenton试剂在水处理中的应用。
关键词 fenton试剂 氧化作用 水处理 氧化技术 AOPS 化学混凝法
下载PDF
Fenton法的氧化机理及在废水处理中的应用进展 被引量:101
17
作者 包木太 王娜 +2 位作者 陈庆国 郭省学 李希明 《化工进展》 EI CAS CSCD 北大核心 2008年第5期660-665,共6页
阐述了普通Fenton法、光-Fenton法和电-Fenton法的原理及应用,并对各种类型的Fenton法的优势、问题及发展趋势作了评述,尤其介绍了它和其它技术(生物法、混凝法、吸附法)联用的优势及应用情况。
关键词 fenton试剂 光-fenton 电-fenton 联用技术 废水处理
下载PDF
Fenton氧化/混凝法后续处理垃圾渗滤液研究 被引量:29
18
作者 李军 王磊 +5 位作者 彭锋 刘红 何建平 孟光辉 陈刚 金永祥 《中国给水排水》 CAS CSCD 北大核心 2008年第3期64-67,共4页
六里屯垃圾填埋场的垃圾渗滤液经UASB+A/O系统处理后,COD和氨氮含量分别在1350~1500和280~420mg/L,还需要进一步处理。因此采用Fenton氧化/混凝法作为后续处理工艺,考察了不同条件下对污染物的去除效果。结果表明,当pH=7、[Fe2+]=0.01... 六里屯垃圾填埋场的垃圾渗滤液经UASB+A/O系统处理后,COD和氨氮含量分别在1350~1500和280~420mg/L,还需要进一步处理。因此采用Fenton氧化/混凝法作为后续处理工艺,考察了不同条件下对污染物的去除效果。结果表明,当pH=7、[Fe2+]=0.0167mol/L、[H2O2]=0.05mol/L、[FeCl3]=600mg/L、[AP410C]=4mg/L时,该工艺对浊度、COD和氨氮的去除率分别为82%、80.7%、55.9%,去除效果较好。 展开更多
关键词 fenton试剂 垃圾渗滤液 絮凝剂 COD 浊度 氨氮
下载PDF
超声波促进Fenton法脱色甲基橙溶液的研究 被引量:35
19
作者 陶长元 刘作华 +3 位作者 李晓红 杜军 司秀杰 朱俊 《环境科学》 EI CAS CSCD 北大核心 2005年第5期111-114,共4页
分别研究了超声波、Fenton试剂、超声波-Fenton试剂作用下甲基橙溶液的脱色和COD去除行为.结果表明,超声波单独作用甲基橙溶液几乎没有脱色效果;Fenton试剂单独作用400mg/L的甲基橙溶液30min,甲基橙色度去除率67.51%,COD去除率63.15%;... 分别研究了超声波、Fenton试剂、超声波-Fenton试剂作用下甲基橙溶液的脱色和COD去除行为.结果表明,超声波单独作用甲基橙溶液几乎没有脱色效果;Fenton试剂单独作用400mg/L的甲基橙溶液30min,甲基橙色度去除率67.51%,COD去除率63.15%;而超声波-Fenton试剂时,溶液色度去除率86.91%,COD去除率80.32%.超声波与Fenton试剂对甲基橙溶液的脱色和COD去除有协同作用.Fenton试剂脱色强酸性甲基橙溶液是氧化反应,而在pH大于5时,是还原反应. 展开更多
关键词 超声波 甲基橙 fenton试剂
下载PDF
Fenton试剂与染料溶液的反应 被引量:109
20
作者 徐向荣 王文华 李华斌 《环境科学》 EI CAS CSCD 北大核心 1999年第3期72-74,共3页
Fenton试剂与酸性、活性、直接、阳离子、分散和还原6类18种染料反应时,前4类染料在180min内完全脱色,TOC浓度均显著下降.后2类染料的脱色率很低,TOC浓度降低不多.研究了不同金属离子与紫外光的催化下,H... Fenton试剂与酸性、活性、直接、阳离子、分散和还原6类18种染料反应时,前4类染料在180min内完全脱色,TOC浓度均显著下降.后2类染料的脱色率很低,TOC浓度降低不多.研究了不同金属离子与紫外光的催化下,H2O2对染料罗丹明B溶液的氧化反应.催化的结果为:Fe2+/UV>Cu2+/UV>Fe2+>Cu2+>Mn2+/UV>Ag+/UV>Mn2+>Ag+.通过与还原蓝RSN溶液的反应,表明Fenton/UV体系中的反应程度大于Fenton及H2O2/UV2种体系中反应程度的加和。 展开更多
关键词 fenton试剂 UV体系 染料废水 废水处理
下载PDF
上一页 1 2 62 下一页 到第
使用帮助 返回顶部