期刊文献+
共找到3,015篇文章
< 1 2 151 >
每页显示 20 50 100
Clinical role and importance of fluorescence in situ hybridization method in diagnosis of H pylori infection and determination of clarithromycin resistance in H pylori eradication therapy 被引量:10
1
作者 zlem Yilmaz Ebru Demiray 《World Journal of Gastroenterology》 SCIE CAS CSCD 2007年第5期671-675,共5页
H pylori is etiologically associated with gastritis, gas-tric and duodenal ulcers, gastric adenocarcinoma and mucosa-associated lymphoid tissue (MALT) lymphoma. Eradicating H pylori may convert rapidly the outcome of ... H pylori is etiologically associated with gastritis, gas-tric and duodenal ulcers, gastric adenocarcinoma and mucosa-associated lymphoid tissue (MALT) lymphoma. Eradicating H pylori may convert rapidly the outcome of related diseases with the use of more accurate diagnostic molecular tests. Indeed some of the tests cannot give the evidence of current infection; H pylori can be detected by noninvasive and invasive methods, the latter requiring an endoscopy. Eradication failure is a big problem in H pylori infection. Recently, clarithromycin resistance in H pylori strains is increasing and eradicati-on therapy of this bacterium is becoming more difficult. Molecular methods have frequently been applied besides phenotypic methods for susceptibility testing to detect clarithromycin resistance due to mutations in the 2143 and 2144 positions of 23S rRNA gene. Fluorescence in situ hybridization (FISH) method on paraffin embedded tissue is a rapid, accurate and cost-effective method for the detection of H pylori infection and to determine clarithromycin resistance within three hours according to the gold standards as a non-culture method. This method can also be applied to fresh biopsy samples and the isolated colonies from a culture of H pylori, detecting both the culturable bacillary forms and the coccoid forms of H pylori, besides the paraffin embedded tissue secti-ons. This technique is helpful for determining the bac-terial density and the results of treatment where clarith-romycin has been widely used in populations to increase the efficacy of the treatment and to clarify the treatment failure in vitro. 展开更多
关键词 H pylori fluorescence in situ hybridization method Clarithromycin resistance
下载PDF
A TOTAL CONTENT X—RAY FLUORESCENCE METHOD FOR COPPER PROSPECTING
2
作者 周四春 谢庭周 葛良全 《Nuclear Science and Techniques》 SCIE CAS CSCD 1992年第3期191-195,共5页
A new method is proposed to prospect copper deposits with portable XRF analyzer. The method is based on the close relation between Cu and the chalcophile elements or some other elements in the geochemical anomalies of... A new method is proposed to prospect copper deposits with portable XRF analyzer. The method is based on the close relation between Cu and the chalcophile elements or some other elements in the geochemical anomalies of a Cu deposit. Applications of the technique in Northeast China are presented. 展开更多
关键词 Portable X-RAY fluorescence ANALYZERS Total content X-RAY fluorescence method PROSPECTING for COPPER DEPOSITS
下载PDF
Influence enhancement effect of bi-frequency ultrasonic irradiation by TA fluorescence method
3
作者 FAN Xinnan~(1,2), ZHU Changping~(1,2), FENG Ruo~(2,1), WANG Yuming~3, He Shichuan~1 (1 Department of Computer & Information Engineering, Hohai University, Changzhou 210032, China) (2 Institute of Acoustics, Nanjing University, Nanjing 210093, China) (3 Changzhou College of Mechanical and Electrical Engineering, Changzhou 210032, China) 《声学技术》 CSCD 2004年第S1期36-38,共3页
Based on a previous research of cavitation effect under bi-frequency ultrasound irradiation, this paper studies bi-frequency irradiations with similar experimental settings. The additional irradiation sources with fre... Based on a previous research of cavitation effect under bi-frequency ultrasound irradiation, this paper studies bi-frequency irradiations with similar experimental settings. The additional irradiation sources with frequencies of 1.04MHz, 0.8MHz and 1.7MHz are individually combined with the main ultrasonic irradiation source with frequency of 28kHz to form bi-frequency ultrasonic irradiation. The intensity of 28kHz irradiation was fixed at 12.5W/cm^2, while the intensity of the ultrasound at the other three frequencies is varied from1 W/cm^2 to 18 W/cm^2. It turns out that under the influence of the bi-frequency irradiation, the fluorescence intensity is obviously greater than the sum of those at individual frequencies. So the frequency of the additional sonication strikingly influences the fluorescence enhancement effect. For example, the fluorescence enhancement effect of 1.04MHz is stronger than that of 1.7MHz, and the enhancement effect of 0.8MHz is further stronger than that of 1.04MHz. Under the sonic intensity of (7.9)W/cm^2, the fluorescence intensity of 1.04MHz is approximately twice that of 1.7MHz while the fluorescence intensity of 0.8MHz is approximately 1.5 times that of 1.04MHz. 展开更多
关键词 TA fluorescence method TEREPHTHALATE FREQUENCY effect bi-frequency ultrasound.
下载PDF
Microstructure and UV Fluorescence of Amorphous I/Au Composite Nanofilms Based on LVDCS Method
4
作者 ZHAI Xiaoyu DING Yufeng +7 位作者 KANG Yixin LI Siqi PAN Liangliang ZHANG Dapeng HE Huimei JIANG Xinhua WANG Yun MENG Qingyun 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2019年第6期1254-1258,共5页
The amorphous I/Au composite nanofilms were prepared by low vacuum direct current sputtering(LVDCS) method. The optimized preparation technologies contain growth pressure, time, gaseous environment and annealing condi... The amorphous I/Au composite nanofilms were prepared by low vacuum direct current sputtering(LVDCS) method. The optimized preparation technologies contain growth pressure, time, gaseous environment and annealing conditions. The maximum fluorescence emission(λemmax) of I/Au nanofilms was observed at wavelength of 375 nm, and the intensity of fluorescence emission peak of annealed I/Au films was smaller than that of unannealed one due to fewer amorphous Au nanoparticles, caused by annealing treatment. In the UV-Vis absorption spectra, the intensity of UV-Vis absorption peak of annealed I/Au nanofilms is larger than that of the unannealed one. This work also developed a new way to grow I/Au composite fluorescent thin films. 展开更多
关键词 LVDCS method AMORPHOUS I/Au nanofilms fluorescence
原文传递
Study on State of Terbium Ion in Liposome by One order Derivative Fluorescence Quenching Method
5
作者 Mu Xiao-jing Fang Guo-chun Yao Song-nian 《Wuhan University Journal of Natural Sciences》 EI CAS 1999年第4期469-472,共4页
The state of Tb3+ is investigated in liposome. When the concentration of PC is below CMC (critical micell concentration), most of Tb3+ is associated with PC, the binding constant is about 3.35×103 L/mol. When the... The state of Tb3+ is investigated in liposome. When the concentration of PC is below CMC (critical micell concentration), most of Tb3+ is associated with PC, the binding constant is about 3.35×103 L/mol. When the concentration of PC is beyond CMC, most of Tb3+ is dimerized, the dimerization constant is about 3.92×104L/mol. In PC?CH?H2O system, the binding constant of Tb3+?CH complex 2.93×104L/mol is obtained. 展开更多
关键词 one-order derivative fluorescence quenching method LIPOSOME PC-Tb binding constant
下载PDF
A New Fluorescence Method for the Measurement of Intracellular Free Rare Earth Ions: Fura-2 as an Indicator
6
作者 Pin YANG Tian xin WEI +2 位作者 Chun ying Jin xi WANG Da pin FAN(Institute of Molecular Science,ShanXi University,Taiyuan,030006)(Chemical and Chemical Industry College of Nanjing University,Nanjing,210093)(Medical College of NanJing University, NanJing, 210093) 《Chinese Chemical Letters》 SCIE CAS CSCD 1996年第9期820-822,共3页
Fura-2 was first used to monitor intracellular RE(3+). The characterizations of RE3+-Fura-2 interactions in solutions simulating intracellular ionic composition show that La3+ and Y3+ both form 1:1 RE(3+)-fura-2 compl... Fura-2 was first used to monitor intracellular RE(3+). The characterizations of RE3+-Fura-2 interactions in solutions simulating intracellular ionic composition show that La3+ and Y3+ both form 1:1 RE(3+)-fura-2 complexes. The apparent dissociation constants are 1.61×10(-7)M,and 4.04×10(-7)M,respectively. The mouse myeloma(SP2/0) cells exposed to free RE(3+) or free RE(3+) and some small molecules in body were Studied by single cell canon measurement system.The results support the assumption that RE(3+) ions cannot enter the cytoplasm of living cells, and the small molecules used in our experiments couldn't improve the permeability of RE(3+)ions. 展开更多
关键词 method the MEASUREMENT INTRACELLULAR RARE fluorescence Free
下载PDF
New HPLC Method with Experimental Design and Fluorescence Detection for Analytical Study of Antihypertensive Mixture,Amlodipine and Valsartan 被引量:1
7
作者 Tadeusz Inglot Anna Gumieniczek +1 位作者 Paulina Maczka Ewelina Rutkowska 《American Journal of Analytical Chemistry》 2013年第1期17-23,共7页
New HPLC method was developed for determination of amlodipine and valsartan in their binary mixture as a part of routine control of combined formulations. The method was validated to meet official requirements includi... New HPLC method was developed for determination of amlodipine and valsartan in their binary mixture as a part of routine control of combined formulations. The method was validated to meet official requirements including selectivity, stability, linearity, precision and accuracy. Chromatography was carried out using a LiChrospher RP-18 column, a mixture containing acetonitrile, phosphate buffer of pH 3.5 and methanol (45:45:10, v/v/v) and new fluorescence detection at 255 nm for excitation and 448 nm for emission. The effect of methanol content, pH of the buffer, flow rate, detection wavelengths and column temperature was estimated in robustness study, according to a plan defined by the Plackett-Burman design. For identification of significant effects, both graphical and statistical methods were used. Ro-bustness for dissolution test was checked estimating the effects of paddle speed, temperature and pH of dissolution medium. The method was proved to complying with all official guidelines. Therefore, it is suitable for determination of amlodipine and valsartan in their binary mixtures for different analytical and pharmaceutical purposes. 展开更多
关键词 HPLC method fluorescence Detection Experimental Design Amlodipine and Valsartan Binary Mixture
下载PDF
Determination of Bisoprolol Fumarate by Fluorescence Quenching Method
8
作者 Yu LIN Xiaomei LAN 《Medicinal Plant》 CAS 2020年第2期30-32,37,共4页
[Objectives]To establish a new method for indirect determination of bisoprolol fumarate based on fluorescence quenching technology.[Methods]In ammonia water and ammonium chloride buffer solution at pH=9.2,whenλexcita... [Objectives]To establish a new method for indirect determination of bisoprolol fumarate based on fluorescence quenching technology.[Methods]In ammonia water and ammonium chloride buffer solution at pH=9.2,whenλexcitation=277 nm andλemission=596 nm,with the increase of CCu2+,the fluorescence signal intensity of bisoprolol fumarate weakened,and the difference between the fluorescence intensity of bisoprolol fumarate itself and the fluorescence intensity of the test solution after the quencher Cu2+was added(ΔF)and Cbisoprolol fumarate showed a good linear relationship.[Results]In the range of 15.39-76.93μg/mL,ΔF=146.7 Cbisoprolol fumarate+482.1,r=0.9988,and the detection limit is 0.1391μg/mL.[Conclusions]The fluorescence quenching method has been applied to the determination of actual samples with a recovery rate of 99.9%and an RSD of 2.7%.The results are satisfactory. 展开更多
关键词 BISOPROLOL FUMARATE COMPLEXING fluorescence QUENCHING method Content DETERMINATION
下载PDF
A FLUORESCENCE QUENCHING IMNUNOASSAY METHOD FOR DETERMINATION OF TRACE ALBUMIN USING UNLABELED EUROPIUM CHELATE
9
作者 Feng Ji YAO Mei HONG Xiao Da YANG Yun Xiang CI Department of Chemistry,Peking University,100871 《Chinese Chemical Letters》 SCIE CAS CSCD 1992年第12期1011-1014,共4页
A fluoroimmunoassay method using unlabeled europium chelate is described.The principle is similar to that of fluoroimmunoassay method using lanthanide chelate as labels.The procedure is simple because labeling process... A fluoroimmunoassay method using unlabeled europium chelate is described.The principle is similar to that of fluoroimmunoassay method using lanthanide chelate as labels.The procedure is simple because labeling process is omitted.The detection limit is about 10^(10) mol/L antigen.The relative standard deviation of immunoassay is less than 10%.The recoveries of human serum albumin and estradiol protein conjugate are 96-105% and 111% respectively. 展开更多
关键词 RSA Eu A fluorescence QUENCHING IMNUNOASSAY method FOR DETERMINATION OF TRACE ALBUMIN USING UNLABELED EUROPIUM CHELATE
下载PDF
Determination of Anionic Surfactants in Environmental Water Samples Using Fluorescence Enhancement Method Based on Fe_3O_4@PAA-RB Fluorescent Nanoparticles
10
作者 RAO Tong-de 《Meteorological and Environmental Research》 2012年第5期25-27,共3页
[ Objective] The study aims at developing a novel fluorescence enhancement method to determine anionic surfactants. [ Method] Based on Fe3O4 @ PAA-RB fluorescent nanoparticles as fluorescent probes, we have developed ... [ Objective] The study aims at developing a novel fluorescence enhancement method to determine anionic surfactants. [ Method] Based on Fe3O4 @ PAA-RB fluorescent nanoparticles as fluorescent probes, we have developed a novel fluorescence enhancement method for the determi- nation of an anionic surfactant sodium dodecyl sulfate (SDS) through the gradual optimization of experiment conditions. [ Result] Under the opti- mum conditions, the extent of fluorescence enhancement is directly proportional to SDS concentration varying from 0.5 to 16.0 μmol/L, and the de- tection limit reaches 0.051 μmol/L. The relative standard deviation (RSD) for 4.0 μmol/L SDS is 3.3% ( n =6). The proposed method has been successfully applied to the determination of SDS in environmental water samples, with recovery of 96.3% -105.5%. E Conclusion] The novel fluo- rescence enhancement method is not only simple and rapid, but also has avoided using tedious solvent-extraction and toxic organic solvents. 展开更多
关键词 fluorescence enhancement method Fe3O4 @ PAA-RB fluorescent nanoparticles Sodium dodecyl sulfate (SDS) China
下载PDF
A QUENCHING FLUORESCENCE IMMUNOASSAY METHOD FOR DETERMINATION OF TRACE ALBUMIN USING UNLABELED TERBIUM CHELATE
11
作者 Feng Ji YAO Pei Hong LI Xiao Da YANG Bo XING Yun Xiang CI (Department of Chemistry,Peking University,100871) 《Chinese Chemical Letters》 SCIE CAS CSCD 1991年第9期737-738,共2页
A fluoroimmunoassay method using unlabeled Terbium chelate is described.The principle is similar to that of fluoroimmunoassay method using lanthanide chelate as labels.The procedure is simpte because labeling process ... A fluoroimmunoassay method using unlabeled Terbium chelate is described.The principle is similar to that of fluoroimmunoassay method using lanthanide chelate as labels.The procedure is simpte because labeling process is unnecessary.The recovery of HSA and albumin in urine is 107% and 95% respectively.The standard deviation is tess than 10%. 展开更多
关键词 FIA A QUENCHING fluorescence IMMUNOASSAY method FOR DETERMINATION OF TRACE ALBUMIN USING UNLABELED TERBIUM CHELATE
下载PDF
Determination of Chlorobenzene by Hydroxypropyl-β- Cyclodextrin Sensitized Fluorescence Quenching Method with Neutral Red as a Fluorescence Probe
12
作者 G.Z. Zou M. Qian X.L. Zhang 《Journal of Environmental Science and Engineering》 2010年第2期9-13,共5页
The fluorescence quenching of inclusion complex of neutral red (NR) and hydroxypropyl-β-cyclodextrin (HP-β-CD) carried by chlorobenzene was investigated. The fluorescence intensity of NR increased due to the for... The fluorescence quenching of inclusion complex of neutral red (NR) and hydroxypropyl-β-cyclodextrin (HP-β-CD) carried by chlorobenzene was investigated. The fluorescence intensity of NR increased due to the formed inclusion complex of HP-β-CD and NR. But the fluorescence intensity of NR-HP-β-CD diminished when chlorobenzene was added, and there was a linear relationship between the fluorescence quenching value of the system (△IF = IF, NR-HP-β-CD - IF, CB-NB-NR-HP-β-CD) and the concentration of chlorobenzene. Based on this, a novel fluorescence quenching method for the determination of chlorobenzene with NR as a fluorescence probe has been developed. Under the optimal conditions, the linear range of calibration curve for the determination of chlorobenzene was 5.0 × 10^-8 - 8.0 × 10^-6 mol/L and the detection limit was 1.0 × 10^-8 mol/L. It has been applied to determination ofchlorobenzene in synthetic waste water samples with satisfactory results. 展开更多
关键词 CHLOROBENZENE CYCLODEXTRIN neutral red. fluorescence quenching method
下载PDF
Determination of heavy metal ion in landfill leachate with solvent extracting & fluorescence quenching method
13
作者 YANG Ji-dong 《Journal of Environmental Science and Engineering》 2008年第10期24-29,79,共7页
Add the masking agent and biscyclohexanoneoxalyldihydraone into the diluted clarificd liquid of the landfill leachate which was treatmented by digestion and centrifugal filtration to complexate all heavy metal ion in ... Add the masking agent and biscyclohexanoneoxalyldihydraone into the diluted clarificd liquid of the landfill leachate which was treatmented by digestion and centrifugal filtration to complexate all heavy metal ion in the trcatmented liquid, and extracted using CHCl3 many time, then it were demasking and decomposing respectively, and adjusted different pH and formed Me^n+-PAN coordination compound when these metal ion reaction with PAN. The Fluoresence quenching of Rh6G (λex/λem=543mn/558nm) when the metal ion coordination compound was add into the Rh6G solution step by step, the quenching intensity was directly proportional to the concentration of the metal ion in the certain range. So a new method of fast and simple for determination of trace metal ion in landfill lcachate was established to determine metal ion in sample of different landfill leachate in Three Gorge Water Reservoir, and comparison the classic assay method with satisfactory results. 展开更多
关键词 landfill leachate metal ion rhodamine 6G fluorescence quenching method 1- (2-pyridine-eazo)-2naphthol
下载PDF
Soller slits automatic focusing method for multi-element fluorescence detector
14
作者 Ya-Yun Yang Qian Gao +3 位作者 Song-Qi Gu Hai-Sheng Yu Rui-You Lu Yu-Ying Huang 《Nuclear Science and Techniques》 SCIE CAS CSCD 2016年第5期179-187,共9页
In X-ray absorption fine structure(XAFS) experiments,Soller slits are widely used as filter devices in order to improve the signal to noise ratio.Performing high accuracy manual focusing operations is a time-consuming... In X-ray absorption fine structure(XAFS) experiments,Soller slits are widely used as filter devices in order to improve the signal to noise ratio.Performing high accuracy manual focusing operations is a time-consuming process;therefore,this work introduces an automatic focusing method for Soller slits in multi-element fluorescence detectors.This method establishes a relation model between the fluorescence intensity distribution and the coordinates of the fluorescence excitation point.According to this relation model,the actual coordinates of the fluorescence excitation point can be deduced from the detected fluorescence intensity distribution and used in focusing operations.This method has proven to be feasible in an XAFS experiment at the BL14W1 beamline of the Shanghai Synchrotron Radiation Facility. 展开更多
关键词 荧光检测器 聚焦方法 狭缝 X射线吸收精细结构 XAFS实验 关系模型 光强度分布 高信噪比
下载PDF
Quantitative energy-dispersive X-ray fluorescence analysis for unknown samples using full-spectrum least-squares regression 被引量:6
15
作者 Yong-Li Liu Qing-Xian Zhang +2 位作者 Jian Zhang Hai-Tao Bai Liang-Quan Ge 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第3期149-159,共11页
The full-spectrum least-squares(FSLS) method is introduced to perform quantitative energy-dispersive X-ray fluorescence analysis for unknown solid samples.Based on the conventional least-squares principle, this spectr... The full-spectrum least-squares(FSLS) method is introduced to perform quantitative energy-dispersive X-ray fluorescence analysis for unknown solid samples.Based on the conventional least-squares principle, this spectrum evaluation method is able to obtain the background-corrected and interference-free net peaks, which is significant for quantization analyses. A variety of analytical parameters and functions to describe the features of the fluorescence spectra of pure elements are used and established, such as the mass absorption coefficient, the Gi factor, and fundamental fluorescence formulas. The FSLS iterative program was compiled in the C language. The content of each component should reach the convergence criterion at the end of the calculations. After a basic theory analysis and experimental preparation, 13 national standard soil samples were detected using a spectrometer to test the feasibility of using the algorithm. The results show that the calculated contents of Ti, Fe, Ni, Cu, and Zn have the same changing tendency as the corresponding standard content in the 13 reference samples. Accuracies of 0.35% and 14.03% are obtained, respectively, for Fe and Ti, whose standard concentrations are 8.82% and 0.578%, respectively. However, the calculated results of trace elements (only tens of lg/g) deviate from the standard values. This may be because of measurement accuracy and mutual effects between the elements. 展开更多
关键词 Energy-dispersive X-ray fluorescence analysis Full-spectrum LEAST-SQUARES method Effective atomic number Mass attenuation coefficient Fundamental parameter method
下载PDF
Study on gaseous CS_2 using laser-induced fluorescence
16
作者 Pan Zhe Zhang Yue +2 位作者 Deng Guohong Pan Xunxi , Hou Huiqi Li Changlin(Environmental Science Institute , Fudan University, Shanghai 200433 , China) 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 1995年第4期484-490,共7页
StudyongaseousCS_2usinglaser-inducedfluorescencePanZhe;ZhangYue;DengGuohong;PanXunxi,HouHuiqi;LiChanglin(Env... StudyongaseousCS_2usinglaser-inducedfluorescencePanZhe;ZhangYue;DengGuohong;PanXunxi,HouHuiqi;LiChanglin(EnvironmentalScience... 展开更多
关键词 fluorescence gaseous CS_2 LIF method.
下载PDF
QM/MM Study of the Second Harmonic Generation and Two-photon Absorption Properties of a Fluorescent Proteins-Dreiklang
17
作者 张敏熠 魏婧 +2 位作者 宋金帅 吴鹏 李春森 《Chinese Journal of Structural Chemistry》 SCIE CAS CSCD 2018年第9期1393-1403,共11页
A new reversibly switchable fluorescent protein(RSFP), namely Dreiklang, exhibits prominent feature that the wavelengths for switching and fluorescence are decoupled due to its great different structures between bri... A new reversibly switchable fluorescent protein(RSFP), namely Dreiklang, exhibits prominent feature that the wavelengths for switching and fluorescence are decoupled due to its great different structures between bright and dark states. This feature might also induce some nonlinear optic(NLO) properties changing as switching between two states, which might promote new method of biological science. We employ the QM/MM method to simulate the structures of different states, and study their second harmonic generation(SHG) and two-photon absorption(TPA) properties. And we found different states of Dreiklang have different SHG and TPA responses. The SHG and TPA properties of Dreiklang are correlated to particularly geometrical structures of different states, especially the centrosymmetric or nocentrosymmetric π-stacking structures which are formed by chromophore and beside residue Tyr203, so the SHG and TPA responses could be changed as the light induces switching among different states of Dreiklang. This work would prospectively guide the application of Dreiklang on the NLO technology, and help the development of new RSFP with special NLO function. 展开更多
关键词 fluorescent proteins the second harmonic generation two-photon absorption QM/MM method
下载PDF
Constant Stress Accelerated Life Tests for Vacuum Fluorescent Display Based on Least Square Method
18
作者 张建平 王睿韬 《Journal of Southwest Jiaotong University(English Edition)》 2010年第1期45-50,共6页
To estimate the life of vacuum fluorescent display (VFD) more accurately and reduce test time and cost, four constant stress accelerated life tests (CSALTs) were conducted on an accelerated life test model. In the... To estimate the life of vacuum fluorescent display (VFD) more accurately and reduce test time and cost, four constant stress accelerated life tests (CSALTs) were conducted on an accelerated life test model. In the model, statistical analysis of test data is achieved by applying lognormal function to describe the life distribution, and least square method (LSM) to calculate the mean value and the standard deviation of logarithm. As a result, the accelerated life equation was obtained, and then a self-developed software was developed to predict the VFD life. The data analysis results demonstrate that the VFD life submits to lognormal distribution, that the accelerated model meets the linear Arrhenius equation, and that the precise accelerated parameter makes it possible to acquire the life information of VFD within one month. 展开更多
关键词 Vacuum fluorescent display Constant stress Accelerated life tests Least square method Lognormal distribution
下载PDF
上一页 1 2 151 下一页 到第
使用帮助 返回顶部