A rapid automatic analyzer and its methodology for effective bentonite content based on image recognition technology
1
作者 Wei Long Lu Xia Xiao-lu Wang 《China Foundry》 SCIE 2016年第5期322-326,共5页
Fast and accurate determination of effective bentonite content in used clay bonded sand is very important for selecting the correct mixing ratio and mixing process to obtain high-performance molding sand. Currently, t... Fast and accurate determination of effective bentonite content in used clay bonded sand is very important for selecting the correct mixing ratio and mixing process to obtain high-performance molding sand. Currently, the effective bentonite content is determined by testing the ethylene blue absorbed in used clay bonded sand, which is usually a manual operation with some disadvantages including complicated process, long testing time and low accuracy. A rapid automatic analyzer of the effective bentonite content in used clay bonded sand was developed based on image recognition technology. The instrument consists of auto stirring, auto liquid removal, auto titration, step-rotation and image acquisition components, and processor. The principle of the image recognition method is first to decompose the color images into three-channel gray images based on the photosensitive degree difference of the light blue and dark blue in the three channels of red, green and blue, then to make the gray values subtraction calculation and gray level transformation of the gray images, and finally, to extract the outer circle light blue halo and the inner circle blue spot and calculate their area ratio. The titration process can be judged to reach the end-point while the area ratio is higher than the setting value. 展开更多
关键词 used clay bonded sand BENTONITE ethylene blue absorbed image recognition automatic analyzer
下载PDF
Application of Dynamic Linear Detecting Method in Data Processing of the Portable Blood Sugar Analyzer
2
作者 Xiaohao Wang Ran Liu +2 位作者 Fei Tang Yangchun Yu Zhaoying Zhou 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期80-82,共3页
In this paper,a dynamic linear detecting method,that the non-linear coefficient NL% was led and the non-linearity of data were estimated continuously and dynamically and determined when NL% exceeded reference value (... In this paper,a dynamic linear detecting method,that the non-linear coefficient NL% was led and the non-linearity of data were estimated continuously and dynamically and determined when NL% exceeded reference value (5%),was used for data processing and could solve the problem caused by the phenomenon of substrate depleting occurred following the redox reaction in portable blood sugar analyzer.By contrast to the conventional end-point method,the dynamic linear detecting method is based on multipoint data collecting.Experiments of measuring the calibration glucose solution with 8 various concentrations from 50 mg/dl to 400 mg/dl were carried out with the analyzer developed by our group.The linear regression curve,whose correlation for the data was 0.9995 and the residual was 2.8080,were obtained.The obtained correlation,residual, and the computation workload are all fit for the portable blood sugar analyzer. 展开更多
关键词 data processing portable blood sugar analyzer dynamic linear detecting method
下载PDF
Application research for fully automatic blood screening in transfu sionservice
3
《中国输血杂志》 CAS CSCD 2001年第S1期407-,共1页
关键词 Application research for fully automatic blood screening in transfu sionservice
下载PDF
两种全自动血沉仪对红细胞沉降率的测定效果比较
4
作者 黄洁 黄海樱 +2 位作者 陈波 吴秋欣 陈靖楠 《中国当代医药》 CAS 2024年第8期106-109,共4页
目的比较普利生LBY-XC-40自动血沉仪(A品牌)和Alifax TEST1全自动快速血沉分析仪(B品牌)测定红细胞沉降率(ESR)的结果,评价不同品牌仪器测定ESR的可靠性。方法选取2022年1月至2月广州医科大学附属第二医院收集的105份血液标本,分别用两... 目的比较普利生LBY-XC-40自动血沉仪(A品牌)和Alifax TEST1全自动快速血沉分析仪(B品牌)测定红细胞沉降率(ESR)的结果,评价不同品牌仪器测定ESR的可靠性。方法选取2022年1月至2月广州医科大学附属第二医院收集的105份血液标本,分别用两种全自动血沉仪和魏氏法测定ESR,以魏氏法为金标准,比较两种全自动血沉仪和魏氏法的相关性,并进行亚组分析。结果A、B品牌与魏氏法的测量结果相关性良好(r=0.890、0.902,P<0.05),与金标准的一致性较好。A品牌与魏氏法的测量结果比较,差异无统计学意义(P>0.05),而B品牌与魏氏法的测量结果比较,差异有统计学意义(P<0.05)。进一步对B品牌进行亚组分析,当ESR<20 mm/h时,B品牌测量结果高于魏氏法,差异有统计学意义(P<0.05);当ESR≥20 mm/h时,B品牌测量结果与魏氏法比较,差异无统计学意义(P>0.05);当血红蛋白≤120 g/L时,B品牌的检测结果低于魏氏法,差异有统计学意义(P<0.05),血红蛋白>120 g/L时,B品牌与魏氏法比较,差异无统计学意义(P>0.05)。结论A品牌与魏氏法测定ESR的结果相似,临床上可用于代替魏氏法快速测定ESR;B品牌与魏氏法测定ESR的结果相关性较好,但需重新建立相匹配的参考区间才更适用于临床测定ESR。 展开更多
关键词 红细胞沉降率 全自动血沉分析仪 魏氏法
下载PDF
自动分割海马亚区感兴趣区与3D-pCASL融合测量脑血流量一致性及可重复性
5
作者 郭婷 闫梦楠 +3 位作者 李金芹 王振华 李健 陈兵 《中国医学影像学杂志》 CSCD 2024年第1期94-99,104,共7页
目的评价颞叶内侧癫痫伴海马硬化患者MRI影像研究中自动分割海马亚区感兴趣区(ROI)与动脉自旋标记(ASL)功能像融合测量脑血流量(CBF)的一致性及可重复性。资料与方法回顾性收集2021年1月—2022年10月宁夏医科大学总医院经MRI诊断或病理... 目的评价颞叶内侧癫痫伴海马硬化患者MRI影像研究中自动分割海马亚区感兴趣区(ROI)与动脉自旋标记(ASL)功能像融合测量脑血流量(CBF)的一致性及可重复性。资料与方法回顾性收集2021年1月—2022年10月宁夏医科大学总医院经MRI诊断或病理证实为海马硬化的52例颞叶内侧癫痫,患者均在3.0T MRI上采用轴位T1加权三维磁化强度预备梯度回波(3D-T1WI-MPRAGE)序列及三维伪连续式ASL序列进行扫描。对3D-T1WI-MPRAGE图像进行自动分割海马亚区,由2名医师进行海马亚区ROI与ASL功能图像融合并测量CBF值,分析测量者内、测量者间的一致性与可重复性。结果2名医师测得CBF值ICC均>0.750,平均为0.868±0.095,左、右侧海马各亚区ICC分别为:下托:0.818/0.801、海马角(CA)1:0.920/0.907、CA2~3:0.759/0.978、CA4:0.757/0.758、齿状回:0.990/0.991;同一名医师ROI勾画的ICC均>0.990,平均为0.994±0.002,左、右侧海马各亚区ICC分别为:下托:0.993/0.993、CA1:0.996/0.995、CA2~3:0.989/0.994、CA4:0.992/0.995、齿状回:0.993/0.996。BlandAltman图可直观展示散点分布和一致性,获取重复性系数。同一观察者对自动分割ROI与ASL功能像融合测量具有一定可重复性。结论基于自动分割海马亚区ROI与ASL功能像融合测量的CBF值具备较高的一致性及可重复性。 展开更多
关键词 癫痫 颞叶内侧 海马硬化 自动分割 海马亚区 磁共振成像 脑血流量
下载PDF
全自动血细胞分析仪联合血涂片细胞形态学对新生儿肺炎的诊断价值分析
6
作者 刘庆 梅玉峰 +1 位作者 熊钻 王亚 《中国实用医药》 2024年第4期75-77,共3页
目的分析全自动血细胞分析仪联合血涂片细胞形态学对新生儿肺炎的诊断价值。方法回顾性分析50例新生儿肺炎患儿的病历资料,所有患儿均接受全自动血细胞分析仪检查及血涂片细胞形态学检查。以病原学检查作为金标准,对比单独与联合检查方... 目的分析全自动血细胞分析仪联合血涂片细胞形态学对新生儿肺炎的诊断价值。方法回顾性分析50例新生儿肺炎患儿的病历资料,所有患儿均接受全自动血细胞分析仪检查及血涂片细胞形态学检查。以病原学检查作为金标准,对比单独与联合检查方法的阳性检出情况及对有核红细胞、异型淋巴细胞、中毒颗粒/空泡变性的阳性检出情况。结果全自动血细胞分析仪+血涂片细胞形态学检查阳性检出率96.00%高于全自动血细胞分析仪检查的66.00%,差异显著(P<0.05)。病原学检查检出有核红细胞15例、异型淋巴细胞10例、中毒颗粒/空泡变性17例。全自动血细胞分析仪+血涂片细胞形态学检查对有核红细胞(100.00%)、异型淋巴细胞(100.00%)、中毒颗粒/空泡变性(100.00%)的检出率均高于对照组(73.33%、60.00%、76.47%),差异显著(P<0.05)。结论全自动血细胞分析仪+血涂片细胞形态学检查可提升对新生儿肺炎的诊断精确性,建议临床采纳。 展开更多
关键词 全自动血细胞分析仪 血涂片细胞形态学 新生儿肺炎 诊断价值
下载PDF
石墨消解-全自动凯氏定氮法测定液体乳中的蛋白质及其方法验证
7
作者 郝琴 《食品安全导刊》 2024年第1期74-76,共3页
采用石墨消解仪消解,全自动凯氏定氮仪蒸馏滴定,建立液体乳中蛋白质含量的测定方法。结果表明,蒸馏时样品取1.0~2.5 g、硫酸取5 mL、硫酸铜和硫酸钾用量分别为0.1 g和1.5 g,消解滴定时加碱量为25 mL、硼酸10 mL、稀释水20 mL、蒸馏时间5... 采用石墨消解仪消解,全自动凯氏定氮仪蒸馏滴定,建立液体乳中蛋白质含量的测定方法。结果表明,蒸馏时样品取1.0~2.5 g、硫酸取5 mL、硫酸铜和硫酸钾用量分别为0.1 g和1.5 g,消解滴定时加碱量为25 mL、硼酸10 mL、稀释水20 mL、蒸馏时间5 min,该条件下检测效果最佳。选择10种代表性液体乳进行方法验证,所得结果均符合国家标准要求。与传统凯氏定氮法相比,该方法操作简单、安全、高效,适用于液体乳蛋白质的日常检测。 展开更多
关键词 石墨消解仪 全自动凯氏定氮仪 蒸馏 滴定
下载PDF
仪器法和手工法测定水源水和生活饮用水中高锰酸盐指数的对比研究
8
作者 黄威 《当代化工研究》 CAS 2024年第5期67-69,共3页
利用高锰酸盐指数全自动分析仪和手工滴定法对国家标准物质、水源水和生活饮用水中实际样品进行比对,比较了两种方法的检出限、精密度、准确度、加标回收率等,且分别考察了氯离子对高锰酸盐指数测定的干扰。结果表明,两种方法的标准样... 利用高锰酸盐指数全自动分析仪和手工滴定法对国家标准物质、水源水和生活饮用水中实际样品进行比对,比较了两种方法的检出限、精密度、准确度、加标回收率等,且分别考察了氯离子对高锰酸盐指数测定的干扰。结果表明,两种方法的标准样品测定值均在标准值允许范围内,且精密度好、准确度高,均能满足水源水和生活饮用水中高锰酸盐指数的检测需要。 展开更多
关键词 高锰酸盐指数 全自动分析仪测定法 手工滴定法 比对
下载PDF
全自动化学需氧量分析仪在水质分析中的应用
9
作者 李煜涛 谢艾 《中国井矿盐》 CAS 2024年第2期33-34,40,共3页
通过使用国标手工法与北京吉天ACOD-30全自动化学需氧量分析仪测定水质化学需氧量的对比实验,分析两种测量方式测定结果之间的差异性。测量结果表明手工法与北京吉天ACOD-30全自动化学需氧量分析仪都能满足《水质化学需氧量的测定重铬... 通过使用国标手工法与北京吉天ACOD-30全自动化学需氧量分析仪测定水质化学需氧量的对比实验,分析两种测量方式测定结果之间的差异性。测量结果表明手工法与北京吉天ACOD-30全自动化学需氧量分析仪都能满足《水质化学需氧量的测定重铬酸盐法》(HJ828-2017)中化学需氧量测定的要求。同时,利用F检验法和t检验法进一步判断手工法与北京吉天ACOD-30全自动化学需氧量分析仪在测试有证标准物质时不存在显著性差异。同时全自动化学需氧量分析仪法可有效控制测定条件,有效节约人力资源,提高分析人员在操作过程中的安全性问题,具有很好的应用前景。 展开更多
关键词 化学需氧量 全自动化学需氧量分析测定仪 测试结果
下载PDF
全自动凯氏定氮仪测定水系沉积物、土壤、岩石全氮含量方法的优化探索
10
作者 吴少青 夏祥 +2 位作者 向治宇 刘涛 廖炫哲 《当代化工研究》 CAS 2024年第4期47-49,共3页
本文通过改变硫酸钾(K_(2)SO_(4))和五水硫酸铜(CuSO4·5H2O)两个联合消化催化剂比例,以及消化催化剂加入量、辛醇滴入量和浓硫酸加入量等条件,探究KII60型全自动凯氏定氮仪在测定水系沉积物与土壤中全氮含量方法的优化以及对比。... 本文通过改变硫酸钾(K_(2)SO_(4))和五水硫酸铜(CuSO4·5H2O)两个联合消化催化剂比例,以及消化催化剂加入量、辛醇滴入量和浓硫酸加入量等条件,探究KII60型全自动凯氏定氮仪在测定水系沉积物与土壤中全氮含量方法的优化以及对比。该方法得出在加入硫酸钾(K_(2)SO_(4))与五水硫酸铜(CuSO4·5H2O)质量比为9:1,加入浓硫酸量为6mL,辛醇最佳滴入量2滴为最佳条件。方法检出限低至25μg/g,相对标准偏差小于2.2%,相对误差小于0.65%,测定结果与传统方法无显著性差异。该方法简便、快捷、准确度高、精密度好,环境友好型,适用于水系沉积物、土壤和岩石中全氮含量的批量测定。 展开更多
关键词 全自动凯氏定氮仪 水系沉积物 土壤 岩石 全氮
下载PDF
全自动分析仪与经典化学法监测地表水中总氮的比对实验研究
11
作者 范明晶 卢立猛 杨翠萍 《皮革制作与环保科技》 2024年第3期137-139,共3页
总氮是控制水质质量的重要指标之一,是湖泊、水库、河流的常规监测项目。水中总氮的测定被列为国家地表水环境质量标准的基本项目,也是城镇污染物排放标准中的基本控制项目,所以准确、高效地测定水中总氮十分必要。本文以崂山区地表水... 总氮是控制水质质量的重要指标之一,是湖泊、水库、河流的常规监测项目。水中总氮的测定被列为国家地表水环境质量标准的基本项目,也是城镇污染物排放标准中的基本控制项目,所以准确、高效地测定水中总氮十分必要。本文以崂山区地表水监测的工作实际为研究依据,从安全性能、监测质量、监测效率等方面对两种分析方式进行比对实验,从而保障和推进生态环境地表水水质监测中总氮项目监测过程的准确和高效。 展开更多
关键词 环境监测 水中总氮的测定 全自动分析仪 仪器法
下载PDF
APS自动化系统在血站标本交接中的应用研究
12
作者 姜蓓蓓 周静婷 +2 位作者 刘专 吴娴 周军兵 《医学检验与临床》 2024年第2期38-41,共4页
目的:通过APS在标本接收、挑选及抓取使用过程的体验,与传统手工模式比较,探讨应用APS自动化系统进行标本交接处理的优缺点。方法:APS系统在启用前进行方法确认及参数调整;传统手工交接与APS系统同时处理一个月的标本,比较两种方法在血... 目的:通过APS在标本接收、挑选及抓取使用过程的体验,与传统手工模式比较,探讨应用APS自动化系统进行标本交接处理的优缺点。方法:APS系统在启用前进行方法确认及参数调整;传统手工交接与APS系统同时处理一个月的标本,比较两种方法在血液标本的交接、挑选等工作环节的差别;统计APS系统在使用初期发现的问题,并给予相应的改进和优化。结果:调整APS系统读取结果模块,增加识别单试剂反应性和双试剂反应性标本功能,增加“两遍酶免一遍核酸”检测策略,并完成软件之间的对接;使用APS系统,每接收100个标本,人工接收需要3分11秒,APS只需35.58秒,时间几乎是传统手工法的1/5;从100个标本中挑选出一个标本,人工挑选需要4分21秒,APS只需41秒,消耗时间是传统手工法的1/7;优化措施为增加抓手垫片,调整抓手力度。结论:APS全自动标本处理系统的使用,减轻工作强度,提高工作效率,降低人工差错。同时使血站实验室自动化、信息化、智能化的管理达到一个新的高度,提高实验室的检测水平,保障了血液检测工作的优化开展。 展开更多
关键词 APS全自动标本处理系统 标本交接 血站
下载PDF
Correlation between GEM Premier 3000 and Vitros5.1+5600, SYSMEX XN-9000 in Detecting Electrolytes and Red Blood Cell Volume
13
作者 Weihua Xue Shunling Li 《Journal of Biomedical Science and Engineering》 2022年第1期44-50,共7页
Objective: To explore the consistency and relevance of the results of the bedside rapid blood gas analyzer GEM premier 3000, the Vitros5.1+5600 biochemical immunoassay analyzer and the SYSMEX XN-9000 automatic blood c... Objective: To explore the consistency and relevance of the results of the bedside rapid blood gas analyzer GEM premier 3000, the Vitros5.1+5600 biochemical immunoassay analyzer and the SYSMEX XN-9000 automatic blood cell analyzer in the central laboratory detecting serum potassium (K<sup>+</sup>), serumsodium (Na<sup>+</sup>), blood glucose (Glu), hemoglobin (Hb) and red blood cell volume (Hct). And to provide a reference for the accurate interpretation of the bedside blood gas analysis report. Method: Usually, ICU patients will be taken arterial blood gas, biochemical and blood samples through the arterial indwelling needle;at the same time patients’ potassium, serum sodium, blood glucose, hemoglobin and red blood cell volume will be detected. This study implemented paired t-test and correlation regression analysis on each group of data, and used the analysis quality requirements (allowable total error) of CLIA’88 proficiency testing program as the criteria for clinical acceptance. Results: The paired t-test showed that the serum potassium, serum sodium and blood glucose detected by GEM premier 3000 and Vitros5.1+5600 were significantly different;and the hemoglobin and red blood cell volume detected by GEM premier 3000 and SYSMEX XN-9000 were significantly different (P < 0.05). The Pearson correlation coefficients (r) of hemoglobin, red blood cell volume and red blood cell volume were 0.860, 0.886, 0.924, 0.841 and 0.856, respectively, and the above test items all had good correlations (P < 0.05). The average (SE) of the paired differences of K<sup>+</sup>, Na<sup>+</sup>, Glu, Hb and Hct detected by the two sets of instruments is less than the allowable error of CLIA’88, and the SE of blood Na<sup>+</sup> and Hb is less than half of the allowable error of CLIA’88. Conclusion: The test results of GEM premier 3000, the central laboratory Vitros5.1+5600 and SYSMEX XN-9000 have good correlation, but the consistency is not good. The test results of GEM premier 3000 cannot replace the central laboratory. 展开更多
关键词 blood Gas analyzer Serum Potassium Serum Sodium blood Glucose HEMOGLOBIN Red blood Cell Volume Central Laboratory
下载PDF
Application of Intelligent Blood Temperature and Humidity Monitoring System in Blood Station
14
作者 Shengwang Chen Zhenquan Ning +1 位作者 Wenlong Lin Shanchang Chen 《Natural Science》 2022年第5期186-192,共7页
Objective: To explore the application of intelligent blood temperature and humidity monitoring system in cold chain management of blood station. Methods: Through the monitoring of fifty sets of cold-chain equipment in... Objective: To explore the application of intelligent blood temperature and humidity monitoring system in cold chain management of blood station. Methods: Through the monitoring of fifty sets of cold-chain equipment in the central blood station in Hezhou for 6 months, the differences between the management of the automatic temperature and humidity monitoring system and the manual management were compared in terms of real-time recording, equipment alarm, data storage, historical data traceability and data analysis. Results: Temperature and humidity automatic monitoring system can automatically real-time acquisition, transmission, storage and alarm according to the required time interval;meanwhile, historical data can be quickly exported and traced, data and charts can be analyzed, and the alarm is real-time and effective. Conclusion: The system can effectively monitor the process of blood cold chain in blood stations and play a key role in ensuring blood quality. It can be popularized and used in blood stations. 展开更多
关键词 blood Temperature and Humidity automatic Monitoring SYSTEM
下载PDF
Study on Digitization of TCM Diagnosis Applied Extraction Method of Blood Vessel
15
作者 Cong Wu Koichi Harada 《Journal of Signal and Information Processing》 2011年第4期301-307,共7页
This paper presents a study on digitization of Traditional Chinese Medicine diagnosis. The research consists of two aspects: a) algorithms for blood vessels extraction in sclera-conjunctiva images, which can be applie... This paper presents a study on digitization of Traditional Chinese Medicine diagnosis. The research consists of two aspects: a) algorithms for blood vessels extraction in sclera-conjunctiva images, which can be applied in syndrome differentiation by observing human eyes (named Ocular Diagnostic in Traditional Chinese Medicine);b) digitization of extracted vessels. First, sclera-conjunctiva region is isolated by optimal threshold segmentation and mathematical operation;Scanning and edge detection methods are used to gain the edge of the blood vessels. Moreover, the edge feature parameters are gained, which can be used to reconstruct the blood vessels. Experimental results show that blood vessels information can be obtained fast and accurately for the further TCM diagnosis by artificial system. 展开更多
关键词 Traditional Chinese Medicine blood VESSEL In WHITE Eye BALL Binary Processing PSEUDO VESSEL Removal DIGITALIZATION Edge Analyze Feature Parameter
下载PDF
Analyzing of "Xu Sanguan a blood":The Black Humor Artistic
16
作者 隋瑞歆 《海外英语》 2011年第4X期199-200,共2页
"Black Humor",as a literary genre."Xu Sanguan a Blood" is a novel created by a well-known writer Yu Hua in 1995.It expresses the human desire to survive when the bad luck.The story tells us that Xu... "Black Humor",as a literary genre."Xu Sanguan a Blood" is a novel created by a well-known writer Yu Hua in 1995.It expresses the human desire to survive when the bad luck.The story tells us that Xu Sanguan spent relying on selling blood they had to get a life and overcome adversity.And when he was old,Xu Sanguan knows that nobody should want his blood,his spirit has collapsed.Black humor from this man gives us more heavy consider and let's know what the truth of the life is.Xu Sanguan had the both of many hates and also many hopes about the family and the life in this story.And his black humor makes him crying with the smile and smiling with the tears. 展开更多
关键词 BLACK HUMOR Xu Sanguan a blood ANALYZING
下载PDF
抗凝剂物质对便携式血糖仪比对测试结果的影响研究 被引量:1
17
作者 王红 《中国实用医药》 2023年第1期107-111,共5页
目的 探讨抗凝剂物质对便携式血糖仪比对测试结果的影响。方法 根据中华人民共和国国家标准GB/T19634-2005制备低浓度、正常范围、高浓度血糖标本各100份。以肝素锂、乙二胺四乙酸二钾(EDTA-K2)及氟化钠作为抗凝物质,采用拜尔抗RO、强... 目的 探讨抗凝剂物质对便携式血糖仪比对测试结果的影响。方法 根据中华人民共和国国家标准GB/T19634-2005制备低浓度、正常范围、高浓度血糖标本各100份。以肝素锂、乙二胺四乙酸二钾(EDTA-K2)及氟化钠作为抗凝物质,采用拜尔抗RO、强生、罗氏、韩国i-SENS4种便携式血糖仪检测;采用日立全自动生化分析仪检测以上浓度的血糖值。比较不同类型便携式血糖仪比对试验通过率,各便携式血糖仪与生化分析仪血糖检测结果;并分析抗凝剂物质对便携式血糖仪比对测试结果的影响,分析不同类型便携式血糖仪与生化分析仪血糖检测结果的相关性,分析不同类型便携式血糖仪精密度。结果 采用拜尔抗RO、强生稳豪、罗氏、韩国i-SENS便携式血糖仪30台完成血糖仪比对试验,30台便携式血糖仪中3台仪器未通过,通过率为90.0%,其中拜尔抗RO通过率为100.00%,而韩国i-SENS便携式血糖仪通过率最低,为66.67%。拜尔抗RO、强生稳豪、罗氏、韩国i-SENS便携式血糖仪对低浓度、正常范围、高浓度标本的测定结果与生化分析仪比较差异均无统计学意义(P>0.05)。为了分析肝素锂、EDTA-K2及氟化钠不同类型抗凝剂物质对便携式血糖仪测定结果的影响,通过不同血糖浓度下利用4种便携式血糖仪测定,结果表明:血糖浓度1.1~3.3 mmol/L、11.1~16.7 mmol/L、18.1~22.2 mmol/L下拜尔抗RO、强生稳豪、罗氏、韩国i-SENS便携式血糖仪采用肝素锂、EDTA-K2抗凝对血糖测定结果无影响;拜尔抗RO、强生稳豪、罗氏、韩国i-SENS便携式血糖仪采用氟化钠作为抗凝物质测定结果高于肝素锂和EDTA-K2,差异具有统计学意义(P<0.05)。采用Pearson相关性分析软件,以生化分析仪作为因变量,便携式血糖仪为自变量,完成线性回归分析,拜尔抗RO、强生稳豪、罗氏、韩国i-SENS便携式血糖仪的r值分别为0.999、0.994、0.984、0.987。以便携式血糖测定仪重复测定100份标本进行计算,拜尔抗RO、强生稳豪、罗氏、韩国i-SENS便携式血糖仪变异系数(CV)分别为1.49%~2.21%、1.84%~2.51%、5.29%~5.53%和5.13%~6.98%,以CV≤7.5%为标准,所有仪器均合格。结论 拜尔抗RO、罗氏、韩国i-SENS血糖仪的检测一致性较好,而国产强生稳豪的检测结果受到氟化钠抗凝物质的影响,但是均与日立全自动生化分析仪结果存在强相关性,临床检测时应根据需求选择合适的便携式血糖仪,降低内外源性干扰物的影响。 展开更多
关键词 抗凝剂物质 便携式血糖仪 测试结果 全自动生化分析仪
下载PDF
有机肥料总氮含量的测定方法研究 被引量:1
18
作者 王卓 郭全恩 +1 位作者 展宗冰 曹诗瑜 《寒旱农业科学》 2023年第4期360-364,共5页
氮作为有机肥料养分的重要来源,其含量是评价有机肥料质量的一项重要指标。为了给有机肥料总氮含量的测定提供快速且精确的测定方法。选择了6个有机肥料样品,用H2SO4-H2O2消煮,分别用连续流动注射分析仪和半自动凯氏定氮仪测定消煮液中... 氮作为有机肥料养分的重要来源,其含量是评价有机肥料质量的一项重要指标。为了给有机肥料总氮含量的测定提供快速且精确的测定方法。选择了6个有机肥料样品,用H2SO4-H2O2消煮,分别用连续流动注射分析仪和半自动凯氏定氮仪测定消煮液中的全氮含量,以探讨不同方法快速而精确地测定有机肥料总氮含量的可行性。结果表明,利用连续流动注射分析仪和半自动凯氏定氮仪测定方法的结果间没有显著性差异,相对标准偏差均在5%以下,且连续流动注射分析仪加标回收率为97.5%耀102.0%。同时由于连续流动注射分析仪测定有机肥料总氮具有快速准确、试剂用量少的优点,适合大批量有机肥料总氮的测定分析。 展开更多
关键词 连续流动注射分析仪 半自动凯氏定氮仪 有机肥料 总氮 含量 测定 比较
下载PDF
全自动间断化学分析仪在苗木氮、磷测定方法中的优良性研究
19
作者 陈诗 母德锦 +5 位作者 王瑜 陈林 唐军荣 蔡年辉 许玉兰 李孙玲 《西部林业科学》 CAS 北大核心 2023年第4期77-82,共6页
为验证SmartChem 200全自动间断化学分析仪测定植物叶片中全氮、全磷的优良性,以1 a生云南松苗木为样品,建立基于SmartChem 200全自动间断化学分析仪,同时测定植物全氮和全磷的方法。结果显示:该方法测定植物中的全氮和全磷分别在0~12 m... 为验证SmartChem 200全自动间断化学分析仪测定植物叶片中全氮、全磷的优良性,以1 a生云南松苗木为样品,建立基于SmartChem 200全自动间断化学分析仪,同时测定植物全氮和全磷的方法。结果显示:该方法测定植物中的全氮和全磷分别在0~12 mg/L和0~5 mg/L范围内呈良好线性关系,相关系数(R^(2))分别为0.9999、0.9994;经t检验测定结果与传统凯氏定氮法、钼锑抗比色法对比无显著差异;该方法与凯氏定氮法测定全氮含量呈极显著相关关系(y=0.9828 x+0.2610,R^(2)=0.9793),该方法与钼锑抗比色法所测全磷含量呈极显著相关关系(y=1.0919 x-0.1677,R^(2)=0.9667);样品的加标回收率分别是全氮98.90%~101.85%、全磷96.10%~105.20%,3个样品重复测定3次的相对标准偏差分别为2.02%~2.79%和0.25%~1.28%。研究结果表明,SmartChem 200全自动间断化学分析仪测定方法试剂量少、操作简单、结果准确可靠、回收率高,测定结果满足对植物全氮、全磷的批量检测要求。 展开更多
关键词 SmartChem 200全自动间断化学分析仪 云南松 全氮 全磷
下载PDF
全自动妇科分泌物分析仪的临床应用及复检规则探讨
20
作者 王萍 郑静 +1 位作者 陈屮 曹永彤 《检验医学与临床》 CAS 2023年第7期884-887,891,共5页
目的 评估GMD-S600全自动妇科分泌物分析仪(简称GMD-S600)的临床应用价值,并初步建立复检规则。方法 随机收集2021年8-12月在该院妇科或中医妇科门诊就诊患者的960例阴道分泌物样本。应用GMD-S600进行阴道分泌物检测;再由2名专业检验师... 目的 评估GMD-S600全自动妇科分泌物分析仪(简称GMD-S600)的临床应用价值,并初步建立复检规则。方法 随机收集2021年8-12月在该院妇科或中医妇科门诊就诊患者的960例阴道分泌物样本。应用GMD-S600进行阴道分泌物检测;再由2名专业检验师采用双盲法对样本进行人工镜检。根据GMD-S600的检测方法,设计了4种复检方案。以人工镜检结果作为判断的金标准,计算复检规则的真阳性率、假阳性率、真阴性率、假阴性率及复检率。通过假阴性率与复检率来评估复检规则的可行性。结果 960例阴道分泌物样本中发现阳性样本242例(25.21%)。与人工镜检结果相比,GMD-S600检测线索细胞、真菌和滴虫的符合率分别为95.63%、93.44%和93.02%。4种复检方案的假阴性率分别为8.26%、2.89%、2.07%和4.55%;复检率分别为34.90%、56.25%、65.52%和43.75%;结合回看有形成分阳性结果图片的方法,方案4复检率可降至24.70%。结论 GMD-S600检测阴道分泌物结果与人工镜检具有较好的一致性;采用复检方案4结合回看有形成分阳性结果图片,能筛选出需要镜检复核的异常标本,提高工作效率及检验质量。 展开更多
关键词 阴道炎 全自动妇科分泌物分析仪 显微镜检查 复检规则