Synchronous tracking control of 6-DOF hydraulic parallel manipulator using cascade control method 被引量:7
1
作者 皮阳军 王宣银 顾曦 《Journal of Central South University》 SCIE EI CAS 2011年第5期1554-1562,共9页
The synchronous tracking control problem of a hydraulic parallel manipulator with six degrees of freedom (DOF) is complicated since the inclusion of hydraulic elements increases the order of the system.To solve this p... The synchronous tracking control problem of a hydraulic parallel manipulator with six degrees of freedom (DOF) is complicated since the inclusion of hydraulic elements increases the order of the system.To solve this problem,cascade control method with an inner/outer-loop control structure is used,which masks the hydraulic dynamics with the inner-loop so that the designed controller takes into account of both the mechanical dynamics and the hydraulic dynamics of the manipulator.Furthermore,a cross-coupling control approach is introduced to the synchronous tracking control of the manipulator.The position synchronization error is developed by considering motion synchronization between each actuator joint and its adjacent ones based on the synchronous goal.Then,with the feedback of both position error and synchronization error,the tracking is proven to guarantee that both the position errors and synchronization errors asymptotically converge to zero.Moreover,the effectiveness of the proposed approach is verified by the experimental results performed with a 6-DOF hydraulic parallel manipulator. 展开更多
关键词 synchronization error CROSS-COUPLING cascade control hydraulic dynamics parallel manipulator degree of freedom
下载PDF
Cascade control based on minimum sensitivity in outer loop for processes with time delay 被引量:6
2
作者 尹成强 惠鸿忠 +2 位作者 岳继光 高洁 郑丽萍 《Journal of Central South University》 SCIE EI CAS 2012年第9期2689-2696,共8页
A new cascade control program was proposed based on modified internal model control to handle stable,unstable and integrating processes with time delay.The program had totally four controllers of which the secondary l... A new cascade control program was proposed based on modified internal model control to handle stable,unstable and integrating processes with time delay.The program had totally four controllers of which the secondary loop had two controllers and the primary loop had two controllers.The two secondary loop controllers were designed using IMC technique.They were decoupled completely and could be adjusted independently,which avoided the undesirable influence on performance of the primary controllers.The main controller in the primary loop was devised as a PID using the method of minimum sensitivity,which could guarantee not only the nominal performance but also the robust stability of the system.A setpoint filter was added in the primary loop to improve the tracking performance.All the controllers of the two closed-loops were designed analytically,and could be adjusted and optimized by single parameter respectively.Simulations were carried out on three various processes with time delay,and the results show that the proposed method can provide a better performance of both set-point tracking and disturbance rejection and robustness against parameters perturbation. 展开更多
关键词 cascade control time delay H∞ performance specification modified internal mode control multiple degrees of freedom
下载PDF
Nonlinear cascade control of single-rod pneumatic actuator based on an extended disturbance observer 被引量:1
3
作者 LI Ai-min MENG De-yuan +1 位作者 LU Bo LI Qing-yang 《Journal of Central South University》 SCIE EI CAS CSCD 2019年第6期1637-1648,共12页
Precise position tracking control of the single-rod pneumatic actuator is considered and a nonlinear cascade controller is developed.The proposed controller comprises an extended disturbance observer(EDOB)and a nonlin... Precise position tracking control of the single-rod pneumatic actuator is considered and a nonlinear cascade controller is developed.The proposed controller comprises an extended disturbance observer(EDOB)and a nonlinear robust control law synthesized by the backstepping method.The EDOB is designed to estimate not only the influence of disturbances but also the parameter uncertainties.With the use of parameter and disturbance estimates,the nonlinear cascade controller,which consists of an outer position tracking loop and an inner load pressure loop,is further designed to attenuate the effects of parameter and disturbance estimation errors.The stability of the closed-loop system is proven by means of Lyapunov theory.Extensive comparative experimental results obtained verify the effectiveness of the proposed nonlinear cascade controller and its performance robustness to parameter and external disturbance variations in practical implementation. 展开更多
关键词 electro-pneumatic servo system extended disturbance observer cascade control robust control position tracking
下载PDF
Monte-Carlo based cascade control approach with focus on real overactuated space systems
4
作者 M.Shahi A.H.Mazinan 《Journal of Central South University》 SCIE EI CAS CSCD 2016年第12期3171-3182,共12页
The present research relies on a cascade control approach through the Monte-Carlo based method in the presence of uncertainties to evaluate the performance of the real overactuated space systems.A number of potential ... The present research relies on a cascade control approach through the Monte-Carlo based method in the presence of uncertainties to evaluate the performance of the real overactuated space systems.A number of potential investigations in this area are first considered to prepare an idea with respect to state-of-the-art.The insight proposed here is organized to present attitude cascade control approach including the low thrust in connection with the high thrust to be implemented,while the aforementioned Monte-Carlo based method is carried out to guarantee the approach performance.It is noted that the investigated outcomes are efficient to handle a class of space systems presented via the center of mass and the moments of inertial.And also a number of profiles for the thrust vector and the misalignments as the disturbances all vary in its span of nominal variations.The acquired results are finally analyzed in line with some well-known benchmarks to verify the approach efficiency.The key core of finding in the research is to propose a novel 3-axis control approach to deal with all the mentioned uncertainties of space systems under control,in a synchronous manner,as long as the appropriate models in the low-high thrusts are realized. 展开更多
关键词 Monte-Carlo based method cascade control approach overactuated space systems low-high thrusts models
下载PDF
Research on Double Cascade Control Algorithm for Self-Balancing Two-Wheeled Vehicle
5
作者 Qingqing Zhang 《Journal of Applied Mathematics and Physics》 2016年第4期618-622,共5页
To solve the problem of self-balancing two-wheeled vehicle, this article presents double cascade PID control algorithm. This method reduces the coupling of balance control, speed control and direction control, because... To solve the problem of self-balancing two-wheeled vehicle, this article presents double cascade PID control algorithm. This method reduces the coupling of balance control, speed control and direction control, because of the special system structure. This article successfully solved the sensor fusion of gyroscope and accelerometer by using Kalman filtering algorithm, and adding in fuzzy PID algorithm to improve the flexibility of the steering system, thus greatly improving the accuracy and response rate of the system. 展开更多
关键词 cascade control Kalman Filter Fuzzy control PID Algorithm
下载PDF
Application Strategies of Automatic Addressable Single-Lamp Control Technology in Tunnel Lighting
6
作者 Huiyan Yang 《Journal of World Architecture》 2024年第2期90-95,共6页
The article mainly studies the application strategy of automatic addressable single-lamp control technology in tunnel lighting.It encompasses an introduction to this technology,an analysis of the tunnel lighting syste... The article mainly studies the application strategy of automatic addressable single-lamp control technology in tunnel lighting.It encompasses an introduction to this technology,an analysis of the tunnel lighting system using automatic addressable single-lamp control technology,and outlines the main development direction for this technology in modern tunnel lighting.The aim is to offer insights that can inform the rational deployment of this technology,thereby enhancing the lighting control effectiveness in modern tunnels and meeting their specific lighting requirements more effectively. 展开更多
关键词 Tunnel lighting Automatic addressable single-lamp control technology System design cascade control
下载PDF
Reinforced temperature control of a reactive double dividing-wall distillation column
7
作者 Wei Qin Lijing Zang +5 位作者 Kejin Huang Haisheng Chen Yang Yuan Xing Qian Liang Zhang Shaofeng Wang 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2023年第2期288-295,共8页
The mass and thermal coupling makes the control of the reactive double dividing-wall distillation column(R-DDWDC) an especially challenging issue with a highly interactive nature. With reference to the separation of a... The mass and thermal coupling makes the control of the reactive double dividing-wall distillation column(R-DDWDC) an especially challenging issue with a highly interactive nature. With reference to the separation of an ideal endothermic quaternary reversible reaction with the most unfavorable ranking of relative volatilities(A + B ■ C + D with α_(A)>α_(C)>α_(D)>α_(B)), the operation rationality of the R-DDWDC is studied in this contribution. The four-point single temperature control system leads to great steady-state discrepancies in the compositions of products C and D and the reason stems essentially from the failure in keeping strictly the stoichiometric ratio between reactants A and B. A temperature plus temperature cascade control scheme is then employed to reinforce the stoichiometric ratio control and helps to secure a substantial abatement in the steady-state discrepancies. A temperature difference plus temperature cascade control scheme is finally synthesized and leads even to better performance than the most effective double temperature difference control scheme. These outcomes reveal not only the operation feasibility of the R-DDWDC but also the general significance of the proposed temperature difference plus temperature cascade control scheme to the inferential control of any other complicated distillation columns. 展开更多
关键词 Reactive double dividing-wall distillation column Temperature control Temperature plus temperature cascade control Temperature difference plus temperature cascade control Process operation
下载PDF
A simple method of tuning series cascade controllers for unstable systems
8
作者 Simi SANTOSH M.CHIDAMBARAM 《控制理论与应用(英文版)》 EI CSCD 2013年第4期661-667,共7页
A simple method is proposed to design P/PI controllers for a series cascade control system for unstable first order plus time-delay (FOPTD) systems. In this paper, the controller design for unstable FOPTD systems ca... A simple method is proposed to design P/PI controllers for a series cascade control system for unstable first order plus time-delay (FOPTD) systems. In this paper, the controller design for unstable FOPTD systems cascaded in series with stable/unstable FOPTD systems is considered. The proposed method is based on equating the coefficients of corresponding powers of s and s2 in the numerator to α1 and α2 times those of the denominator of the closed-loop transfer function for a servo problem. The open loop system consists of an unstable FOPTD system cascaded in series with a stable/unstable FOPTD system. Only two tuning parameters (α1 and α2) are required for the design of controllers. The closed-loop performances are evaluated for both the servo and regulatory problems and the performances are found to be better than that of the well established synthesis method. The robustness for uncertainty in the model parameters is studied and compared with that of the controllers designed by the synthesis method. 展开更多
关键词 cascade control Time-delay process PI controller P controller FOPTD model Tuning
下载PDF
Cascade controller based modeling of a four area thermal:gas AGC system with dependency of wind turbine generator and PEVs under restructured environment
9
作者 Debdeep Saha Lalit Chandra Saikia Asadur Rahman 《Protection and Control of Modern Power Systems》 2022年第1期696-713,共18页
This paper investigates automatic generation control(AGC)of a realistic hybrid four-control area system with a dis-tinct arrangement of thermal units,gas units and additional power generation.A proportional-integral-d... This paper investigates automatic generation control(AGC)of a realistic hybrid four-control area system with a dis-tinct arrangement of thermal units,gas units and additional power generation.A proportional-integral-double deriva-tive cascaded with proportional-integral(PIDD-PI)controller is employed as secondary controller in each control area for robust restructured AGC considering bilateral transactions and contract violations.The Harris Hawks algorithm is used to determine the optimal controller gains and system parameters under several scenarios.Electric vehicle(EV)aggregators are employed in each area to participate fully along with thermal and gas units to compensate for the unscheduled system demand in the local area.A comparison of non-cascaded controllers such as PI-PD,PD-PID and the proposed PIDD-PI proves the superiority of the last.The effect of the decline in inertia is closely examined because of the sudden outage of a generating unit while at the same time considering the change in area frequency response characteristics and area control error.EV fleets make significant contributions to improving the system dynamics dur-ing system inertia loss.The use of EVs in the presence of a wind energy-supported grid can provide a stable efficacy to the power grid.Numerous simulations with higher load demands,stochastic communication delays in presence of the WTG plant,and violations in system loadings and changes in gas turbine time constants in the absence of WTG demonstrate the robustness of the proposed control approach. 展开更多
关键词 Automatic generation control cascade controller Electric vehicle Harris Hawks algorithm Wind turbine generator
下载PDF
Simulation of Greenhouse Heating System Using Fuzzy Smith Cascade Compound Control 被引量:5
10
作者 程昱宁 张侃谕 《Advances in Manufacturing》 SCIE CAS 2000年第S1期143-147,共5页
Aiming at characteristic of time delay, time-varying parameters and much disturb in glass greenhouse heating system, fuzzy smith cascade compound control policy based on typical PID cascade compound control policy is ... Aiming at characteristic of time delay, time-varying parameters and much disturb in glass greenhouse heating system, fuzzy smith cascade compound control policy based on typical PID cascade compound control policy is proposed. Simulation results show that it is effective to overcome the influence of time delay on stability of control system and the system possesses strong robust and good dynamic performance.. 展开更多
关键词 GREENHOUSE heating system fuzzy smith cascade compound control
下载PDF
A hybrid stochastic fractal search and pattern search technique based cascade PI-PD controller for automatic generation control of multi-source power systems in presence of plug in electric vehicles 被引量:1
11
作者 Sasmita Padhy Sidhartha Panda 《CAAI Transactions on Intelligence Technology》 2017年第1期12-25,共14页
A hybrid Stochastic Fractal Search plus Pattern Search (hSFS-PS) based cascade PI-PD controller is suggested in this paper for Automatic Generation Control (AGC) of thermal, hydro and gas power unit based power sy... A hybrid Stochastic Fractal Search plus Pattern Search (hSFS-PS) based cascade PI-PD controller is suggested in this paper for Automatic Generation Control (AGC) of thermal, hydro and gas power unit based power systems in presence of Plug in Electric Vehicles (PEV). Firstly, a single area multi-source power system consisting of thermal hydro and gas power plants is considered and parameters of Integral (I) controller is optimized by Stochastic FractaI Search (SFS) algorithm. The superiority of SFS algorithm over some recently proposed approaches such as optimal control, differential evolution and teaching learning based optimization techniques is demonstrated by comparing simulation results for the identical power system. To improve the system performance further, Pattern Search (PS) is subsequently employed. The study is further extended for different controllers like PI, PID, and cascaded PI-PD controller and the superiority of cascade PI-PD controller over conventional controllers is demonstrated. Then, cascade PI- PD controller parameters of AGC searched using the proposed hSFS-PS algorithm in presence of plug in electric vehicles. The study is also extended to an interconnected power system. It is seen from the comparative analysis that hSFS-PS tuned PI-PD controller in single and multi-area with multi sources improves the system frequency stability in complicated situations. Lastly, a three area interconnected system with PEVs with dissimilar cascade PI-PD controller in each area is considered and proposed hSFS- PS algorithm is used to tune the controller parameters in presence of nonlinearities like rate constraint of units, dead zone of governor and communication delay. 展开更多
关键词 Automatic generation control cascade PI-PD controller Stochastic fractal search Pattern search Plug in electric vehicles
下载PDF
Cascade adaptive control of uncertain unified chaotic systems
12
作者 魏伟 李东海 王京 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第4期165-170,共6页
The chaos control of uncertain unified chaotic systems is considered. Cascade adaptive control approach with only one control input is presented to stabilize states of the uncertain unified chaotic system at the zero ... The chaos control of uncertain unified chaotic systems is considered. Cascade adaptive control approach with only one control input is presented to stabilize states of the uncertain unified chaotic system at the zero equilibrium point. Since an adaptive controller based on dynamic compensation mechanism is employed, the exact model of the unified chaotic system is not necessarily required. By choosing appropriate controller parameters, chaotic phenomenon can be suppressed and the response speed is tunable. Sufficient condition for the asymptotic stability of the approach is derived. Numerical simulation results confirm that the cascade adaptive control approach with only one control signal is valid in chaos control of uncertain unified chaotic systems. 展开更多
关键词 unified chaotic systems cascade adaptive control approach response speed chaos control
原文传递
Practice of Centralized Control over Cascade Hydropower Stations
13
作者 Jin Zehua General Manager, Guizhou Wujiang Hydropower Development Ltd. 《Electricity》 2010年第1期44-47,共4页
Isolated operation of hydropower stations on Wujinag River was seen disadvantages of low rate of water utilization and much loss of electricity caused by abandoned water during low load periods. To tackle the problem,... Isolated operation of hydropower stations on Wujinag River was seen disadvantages of low rate of water utilization and much loss of electricity caused by abandoned water during low load periods. To tackle the problem, centralized control over cascade hydropower stations is practiced with a considerable economic benef it gained. 展开更多
关键词 RATE Practice of Centralized control over cascade Hydropower Stations OVER
下载PDF
Temperature Control System with Multi-closed Loops for Lithography Projection Lens 被引量:4
14
作者 NIE Hongfei LI Xiaoping HE Yan 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2009年第2期207-213,共7页
Image quality is one of the most important specifications of optical lithography tool and is affected notably by temperature, vibration, and contamination of projection lens(PL). Traditional method of local temperat... Image quality is one of the most important specifications of optical lithography tool and is affected notably by temperature, vibration, and contamination of projection lens(PL). Traditional method of local temperature control is easier to introduce vibration and contamination, so temperature control system with multi-closed loops is developed to control the temperature inside the PL, and to isolate the influence of vibration and contamination. A new remote indirect-temperature-control(RITC) method is proposed in which cooling water is circulated to perform indirect-temperature-control of the PL. Heater and cooler embedded temperature control unit(TCU) is used to condition the temperature of the cooling water, and the TCU must be kept away from the PL so that the influence of vibration and contamination can be avoided. A new multi-closed loops control structure incorporating an internal cascade control structure(CCS) and an external parallel cascade control structure(PCCS) is designed to prevent large inertia, multi-delay, and multi-disturbance of the RITC system. A nonlinear proportional-integral(PI) algorithm is applied to further enhance the convergence rate and precision of the control process. Contrast experiments of different control loops and algorithms were implemented to verify the impact on the control performance. It is shown that the temperature control system with multi-closed loops reaches a precision specification at ±0.006 ℃ with fast convergence rate, strong robustness, and self-adaptability. This method has been successfully used in an optical lithography tool which produces a pattern of 100 nm critical dimension(CD), and its performances are satisfactory. 展开更多
关键词 projection lens remote indirect-temperature-control cascade control structure parallel cascade control structure nonlinear proportional-integral(PI) algorithm
下载PDF
Automatic Guidance of an Agricultural Tractor along with the Side Shift Control of the Attached Row Crop Cultivator 被引量:8
15
作者 Javad Robati Hossein Navid +1 位作者 Mahdi Rezaei Amir Rikhtehgar Ghiasi 《Journal of Agricultural Science and Technology(B)》 2012年第1期151-158,共8页
This paper presents the automatic guidance system of an agricultural tractor and the side shift control of the attached row crop cultivator using electro-hydraulic actuators. In order to simulate the dynamic behaviour... This paper presents the automatic guidance system of an agricultural tractor and the side shift control of the attached row crop cultivator using electro-hydraulic actuators. In order to simulate the dynamic behaviour of the tractor along with the attached cultivator, the modified bicycle model was adopted. Steering angle sensor, fibre optic gyroscope (FOG) and RTK-DGPS technologies are assumed for measurements of the steering angle, yaw rate and the lateral position of the tractor, respectively. The kinematics model was used for the implement. In this study four cascade controllers were designed and simulated for tractor guidance which consists ofPD, PD, P and PID controllers. Other PI and PID controllers also had been designed for implement side shifting purpose. Then, these two systems were combined and the performance of the whole system was evaluated through the simulation results. According to the results tractor reaches the desired path after less than 10 seconds. Simulations showed that the maximum deviation of the tractor from the desired path was about 5 cm within this period. And the cultivator blades would follow the predetermined path with steady state error of about 5 cm too. 展开更多
关键词 Row crop cultivator yaw rate servo valve servo cylinder cascade controller.
下载PDF
Direct and Indirect Gradient Control for Static Optimisation 被引量:3
16
作者 Yi Cao 《International Journal of Automation and computing》 EI 2005年第1期60-66,共7页
Static “self-optimising” control is an important concept, which provides a link between static optimisation and control. According to the concept, a dynamic control system could be configured in such a way that when... Static “self-optimising” control is an important concept, which provides a link between static optimisation and control. According to the concept, a dynamic control system could be configured in such a way that when a set of certain variables are maintained at their setpoints, the overall process operation is automatically optimal or near optimal at steady-state in the presence of disturbances. A novel approach using constrained gradient control to achieve “self-optimisation” has been proposed by Cao. However, for most process plants, the information required to get the gradient measure may not be available in real-time. In such cases, controlled variable selection has to be carried out based on measurable candidates. In this work, the idea of direct gradient control has been extended to controlled variable selection based on gradient sensitivity analysis (indirect gradient control). New criteria, which indicate the sensitivity of the gradient function to disturbances and implementation errors, have been derived for selection. The particular case study shows that the controlled variables selected by gradient sensitivity measures are able to achieve near optimal performance. 展开更多
关键词 Plantwide control self-optimising control control schemes decentralised control cascade control automatic di?erentiation.
下载PDF
Grey Wolf Optimization Based Tuning of Terminal Sliding Mode Controllers for a Quadrotor 被引量:2
17
作者 Rabii Fessi Hegazy Rezk Soufiene Bouallègue 《Computers, Materials & Continua》 SCIE EI 2021年第8期2265-2282,共18页
The research on Unmanned Aerial Vehicles(UAV)has intensified considerably thanks to the recent growth in the fields of advanced automatic control,artificial intelligence,and miniaturization.In this paper,a Grey Wolf O... The research on Unmanned Aerial Vehicles(UAV)has intensified considerably thanks to the recent growth in the fields of advanced automatic control,artificial intelligence,and miniaturization.In this paper,a Grey Wolf Optimization(GWO)algorithm is proposed and successfully applied to tune all effective parameters of Fast Terminal Sliding Mode(FTSM)controllers for a quadrotor UAV.A full control scheme is first established to deal with the coupled and underactuated dynamics of the drone.Controllers for altitude,attitude,and position dynamics become separately designed and tuned.To work around the repetitive and time-consuming trial-error-based procedures,all FTSM controllers’parameters for only altitude and attitude dynamics are systematically tuned thanks to the proposed GWO metaheuristic.Such a hard and complex tuning task is formulated as a nonlinear optimization problem under operational constraints.The performance and robustness of the GWO-based control strategy are compared to those based on homologous metaheuristics and standard terminal sliding mode approaches.Numerical simulations are carried out to show the effectiveness and superiority of the proposed GWO-tuned FTSM controllers for the altitude and attitude dynamics’stabilization and tracking.Nonparametric statistical analyses revealed that the GWO algorithm is more competitive with high performance in terms of fastness,non-premature convergence,and research exploration/exploitation capabilities. 展开更多
关键词 QUADROTOR cascade control fast terminal sliding mode control grey wolf optimizer nonparametric Friedman analysis
下载PDF
Application study of digital PID controller in cockpit temperature auto-regulating system 被引量:1
18
作者 周坦胜 董建军 宋宗权 《Journal of Measurement Science and Instrumentation》 CAS 2013年第2期190-193,共4页
Aiming at the inherent blemish existi ng currently in airplane cockpit temperature regulating system,a digital temperatu re auto-regulating design scheme of the system is put forward,namely,a digita l proportional-int... Aiming at the inherent blemish existi ng currently in airplane cockpit temperature regulating system,a digital temperatu re auto-regulating design scheme of the system is put forward,namely,a digita l proportional-integral-derivative(PID) controller used for temperature contr ol is designed.And then it is applied in airpl ane cockpit temperature regulating system by adopting the way of cascade control.Experiment results indicate that the design scheme is reasonable and practical. 展开更多
关键词 inherent blemish digital proportional-integral-derivative (PID) controller cascade control auto-regulating
下载PDF
PI-funnel and inverse hysteresis compensation cascade control of smart soft dielectric elastomer actuator
19
作者 Peng Huang Yawu Wang +2 位作者 Yue Zhang Jundong Wu Chun-Yi Su 《Control Theory and Technology》 EI 2024年第4期552-567,共16页
Smart soft dielectric elastomer actuators(SSDEAs)possess wide applications in soft robotics due to their properties similar to natural muscles,including large deformation ratio,high energy density,and fast response sp... Smart soft dielectric elastomer actuators(SSDEAs)possess wide applications in soft robotics due to their properties similar to natural muscles,including large deformation ratio,high energy density,and fast response speed.However,the complicated asymmetric and rate-dependent hysteresis property,creep property and quadratic input property of the SSDEA pose enormous challenges to its dynamic modeling and motion control.In this paper,first,we construct the dynamic model of the SSDEA by connecting a square module,a one-sided Prandtl–Ishlinskii(OSPI)model and a linear system in series to describe the above properties.The key and innovative aspect of the dynamic modeling lies in cascading the square module in series with the OSPI model to construct the asymmetric hysteresis model.Subsequently,a PI-funnel and inverse hysteresis compensation(PIFIHC)cascade control method of the SSDEA is proposed to actualize its tracking control objective.By performing the inversion operation on the asymmetric hysteresis model,the inverse hysteresis compensation controller(IHCC)is designed to compensate the asymmetric hysteresis property and quadratic input property of the SSDEA.In addition,a PI-funnel controller is designed to cascade with the IHCC to construct the PIFIHC cascade controller to obtain a good tracking performance.Then,the stability analysis of the PIFIHC cascade control system of the SSDEA is performed to theoretically prove that the tracking error can be controlled within the performance funnel and the steady-state error converges to zero.Finally,several practical tracking control experiments of the SSDEA are conducted,and RRMSEs are less than 2.30%for all experiments.These experimental results indicate the effectiveness and feasibility of the proposed PIFIHC cascade control method of the SSDEA. 展开更多
关键词 Smart soft dielectric elastomer actuator Dynamic modeling Inverse hysteresis compensation controller PI-funnel controller cascade controller
原文传递
Enhanced two-loop model predictive control design for linear uncertain systems
20
作者 Mohammad-Ghassem FARAJZADEH-DEVIN Seyed Kamal HOSSEINI SANI 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2021年第1期220-227,共8页
Model predictive controllers(MPC)with the two-loop scheme are successful approaches practically and can be classified into two main categories,tube-based MPC and MPCbased reference governors(RG).In this paper,an enhan... Model predictive controllers(MPC)with the two-loop scheme are successful approaches practically and can be classified into two main categories,tube-based MPC and MPCbased reference governors(RG).In this paper,an enhanced twoloop MPC design is proposed for a pre-stabilized system with the bounded uncertainty subject to the input and state constraints.The proposed method offers less conservatism than the tube-based MPC methods by enlarging the restricted input constraint.Contrary to the MPC-based RGs,the investigated method improves tracking performance of the pre-stabilized system while satisfying the constraints.Additionally,the robust global asymptotic stability of the closed-loop system is guaranteed in a novel procedure with terminal constraint relaxation.Simulation of the proposed method on a servo system shows its effectiveness in comparison to the others. 展开更多
关键词 model predictive control(MPC) robust control cascade control constraint satisfaction