For the purpose of resolving the problem of performance deterioration introduced by inaccurate phase compensation in existing coherent averaging line spectrum detectors, a modified coherent detector is proposed. The t...For the purpose of resolving the problem of performance deterioration introduced by inaccurate phase compensation in existing coherent averaging line spectrum detectors, a modified coherent detector is proposed. The three point interpolation in frequency domain is applied to obtain accurate estimate of phase difference between segments when the segmented length is not an integral multiple of the signal period. Then the segmented data are multiplied by a complex coefficient to remove the phase difference and synchronize the phases of all the segments before coherent averaging. Theoretical analysis shows that there will be a gain of 3.9 dB at most by using the modified detector. The detection performance of the incoher- ent averaging power spectrum detector (AVGPR), the phase coherent averaging detector, the modified coherent averaging detector are compared with each other by computer simulations. The results coincide basically with the theoretical analysis, which show the superiority of the modified detector to the former two detectors.展开更多
We investigate the average coherence with respect to a complete set of complementary measurements.By using a Wigner-Yanase skew information-based coherence measure introduced in Luo and Sun(2017 Phys.Rev.A 96,022130),...We investigate the average coherence with respect to a complete set of complementary measurements.By using a Wigner-Yanase skew information-based coherence measure introduced in Luo and Sun(2017 Phys.Rev.A 96,022130),we evaluate the average coherence of a state with respect to any complete set of mutually unbiased measurements and general symmetric informationally complete measurements,respectively.We also establish analytically the relations among these average coherences.展开更多
文摘For the purpose of resolving the problem of performance deterioration introduced by inaccurate phase compensation in existing coherent averaging line spectrum detectors, a modified coherent detector is proposed. The three point interpolation in frequency domain is applied to obtain accurate estimate of phase difference between segments when the segmented length is not an integral multiple of the signal period. Then the segmented data are multiplied by a complex coefficient to remove the phase difference and synchronize the phases of all the segments before coherent averaging. Theoretical analysis shows that there will be a gain of 3.9 dB at most by using the modified detector. The detection performance of the incoher- ent averaging power spectrum detector (AVGPR), the phase coherent averaging detector, the modified coherent averaging detector are compared with each other by computer simulations. The results coincide basically with the theoretical analysis, which show the superiority of the modified detector to the former two detectors.
基金This work is supported by the National Natural Science Foundation of China under Grant Nos.11805143 and 11675113Beijing Municipal Commission of Education(KZ201810028042).
文摘We investigate the average coherence with respect to a complete set of complementary measurements.By using a Wigner-Yanase skew information-based coherence measure introduced in Luo and Sun(2017 Phys.Rev.A 96,022130),we evaluate the average coherence of a state with respect to any complete set of mutually unbiased measurements and general symmetric informationally complete measurements,respectively.We also establish analytically the relations among these average coherences.