浙江大学医学院附属妇产科医院超声科鲁红主任、周一敏医生于2011年通过英国胎儿医学基金会(Fetal Medicine Foundation;FMF)孕早期暨NT超声筛查资格理论课程培训及图像分析记录考核,获得美国FMF早孕超声筛查认证资格。浙江省产前...浙江大学医学院附属妇产科医院超声科鲁红主任、周一敏医生于2011年通过英国胎儿医学基金会(Fetal Medicine Foundation;FMF)孕早期暨NT超声筛查资格理论课程培训及图像分析记录考核,获得美国FMF早孕超声筛查认证资格。浙江省产前诊断中心超声组也因此成为获得该基金会认证的11—13+6孕周超声检查证书的中心,展开更多
<div style="text-align:justify;"> An in-fiber axial micro-strain sensor based on a Few Mode Fiber Bragg Grating (FM-FBG) is proposed and experimentally characterized. This FM-FBG is in inscribed in a m...<div style="text-align:justify;"> An in-fiber axial micro-strain sensor based on a Few Mode Fiber Bragg Grating (FM-FBG) is proposed and experimentally characterized. This FM-FBG is in inscribed in a multi-layer few-mode fiber (ML-FMF), and could acquire the change of the axial strain along fibers, which depends on the transmission dips. On account of the distinct dual-mode property, a good stability of this sensor is realized. The two transmission dips could have the different sensing behaviors. Both the propagation characteristics and operation principle of such a sensor are demonstrated in detail. High sensitivity of the FM-FBG, ~4 pm/με and ~4.5 pm/με within the range of 0 με - 1456 με, is experimentally achieved. FM-FBGs could be easily scattered along one fiber. So this sensor may have a great potential of being used in sensor networks. </div>展开更多
A few-mode fiber (FMF) is designed to support three spatial modes (LP01, LP 11a, and LP 11 b) and fabricated through plasma chemical vapor deposition (PCVD)and rod-in-tube (RIT) method. Using PDM-DFTS-OFDM- 32...A few-mode fiber (FMF) is designed to support three spatial modes (LP01, LP 11a, and LP 11 b) and fabricated through plasma chemical vapor deposition (PCVD)and rod-in-tube (RIT) method. Using PDM-DFTS-OFDM- 32QAM modulation, wavelength division multiplexing, mode multiplexing, and coherent detection, we successfully demonstrated 200Tb/s (375× 3 × 178.125Gb/s) signal over 1 km FMF using C and L bands with 25 GHz channel spacing. After 1 km FMF transmission, all the tested bit error rates (BERs) are below 20% forward error correction (FEC) threshold (2.0 × 10-2). Within each sub-channel, we achieved a spectral efficiency of 21.375 bits/Hz in the C and L bands.展开更多
文摘浙江大学医学院附属妇产科医院超声科鲁红主任、周一敏医生于2011年通过英国胎儿医学基金会(Fetal Medicine Foundation;FMF)孕早期暨NT超声筛查资格理论课程培训及图像分析记录考核,获得美国FMF早孕超声筛查认证资格。浙江省产前诊断中心超声组也因此成为获得该基金会认证的11—13+6孕周超声检查证书的中心,
文摘<div style="text-align:justify;"> An in-fiber axial micro-strain sensor based on a Few Mode Fiber Bragg Grating (FM-FBG) is proposed and experimentally characterized. This FM-FBG is in inscribed in a multi-layer few-mode fiber (ML-FMF), and could acquire the change of the axial strain along fibers, which depends on the transmission dips. On account of the distinct dual-mode property, a good stability of this sensor is realized. The two transmission dips could have the different sensing behaviors. Both the propagation characteristics and operation principle of such a sensor are demonstrated in detail. High sensitivity of the FM-FBG, ~4 pm/με and ~4.5 pm/με within the range of 0 με - 1456 με, is experimentally achieved. FM-FBGs could be easily scattered along one fiber. So this sensor may have a great potential of being used in sensor networks. </div>
基金Aeknowledgements This work was supported by the Major Scientific and Technological hmovation Projects of Hubci Province (No. 2014AAA001), the National Basic Research Program of China (Nos. 2014CB340100, 2014CB340101, and 2014CB340105). and the Natural Science Foundation of Hubei Prov incc (No. 2015CFA056).
文摘A few-mode fiber (FMF) is designed to support three spatial modes (LP01, LP 11a, and LP 11 b) and fabricated through plasma chemical vapor deposition (PCVD)and rod-in-tube (RIT) method. Using PDM-DFTS-OFDM- 32QAM modulation, wavelength division multiplexing, mode multiplexing, and coherent detection, we successfully demonstrated 200Tb/s (375× 3 × 178.125Gb/s) signal over 1 km FMF using C and L bands with 25 GHz channel spacing. After 1 km FMF transmission, all the tested bit error rates (BERs) are below 20% forward error correction (FEC) threshold (2.0 × 10-2). Within each sub-channel, we achieved a spectral efficiency of 21.375 bits/Hz in the C and L bands.