This paper studied the effect of ferric chloride on waste sludge digestion,dewatering and sedimentation under the optimized doses in co-precipitation phosphorus removal process.The experimental results showed that the...This paper studied the effect of ferric chloride on waste sludge digestion,dewatering and sedimentation under the optimized doses in co-precipitation phosphorus removal process.The experimental results showed that the concentration of mixed liquid suspended solid(MLSS) was 2436 mg.L-1 and 2385 mg.L-1 in co-precipitation phosphorus removal process(CPR) and biological phosphorous removal process(BPR),respectively.The sludge reduction ratio for each process was 22.6% and 24.6% in aerobic digestion,and 27.6% and 29.9% in anaerobic digestion,respectively.Due to the addition of chemical to the end of aeration tank,the sludge content of CPR was slightly higher than that of BPR,but the sludge reduction rate for both processes had no distinct difference.The sludge volume index(SVI) and sludge specific resistance of BPR were 126 ml.g-1 and 11.7×1012 m.kg-1,respectively,while those of CPR were only 98 ml.g-1 and 7.1×1012 m.kg-1,indicating that CPR chemical could improve sludge settling and dewatering.展开更多
Considering that Fe,Al elements in bauxite residue are active components for water purification,an effective polyaluminum ferric chloride(PAFC)coagulant derived from bauxite residue,with Fe2O3 content>5.1%,Al2O3%&g...Considering that Fe,Al elements in bauxite residue are active components for water purification,an effective polyaluminum ferric chloride(PAFC)coagulant derived from bauxite residue,with Fe2O3 content>5.1%,Al2O3%>6.5%,basicity>65%,was successfully prepared.The effect of as-prepared PAFC on the zeta potential for printing and dyeing wastewater was investigated.Comparing with polyferric chloride(PFC)and polyferric sulfate(PFS)for printing and dyeing wastewater treatment,prepared bauxite residue-based PAFC exhibited the optimal performance in the aspects of chromaticity and chemical oxygen demand(COD)removal rate.Furthermore,the combination of bauxite residue-based PAFC and PFS for synergy coagulation of such wastewater demonstrated an obvious positive effect.With the proportion between as-prepared PAFC and PFS to be 2.5:1,the COD of treated wastewater could be further reduced to meet the national level A standard of China,providing a promising route to solve the problem of substandard printing and dyeing sewage outfall by a simple coagulation strategy.展开更多
The kinetics of ferric chloride leaching of sphalerite in the microwave field has being studied in this paper.According to the experimental data,the rate of dissolution of sphalerite microwave irradiation heating is f...The kinetics of ferric chloride leaching of sphalerite in the microwave field has being studied in this paper.According to the experimental data,the rate of dissolution of sphalerite microwave irradiation heating is faster than that with conventional heating.The dissolution of sphalerite in the microwave field was investigated in different condition of temperature,concentration of FeCl,and particle size and a nonisothermal kinetic equation has being obtained.展开更多
BACKGROUND: In order to study the pathogenesis of iron-induced posttraumatic epilepsy (PTE), foreign scholars have established several kinds of PTE animal models, among which, the iron- induced PTE animal models pr...BACKGROUND: In order to study the pathogenesis of iron-induced posttraumatic epilepsy (PTE), foreign scholars have established several kinds of PTE animal models, among which, the iron- induced PTE animal models proposed by Willmore is the most famous. The iron-induced PTE animal models can be established by two methods: one is cortical ferric chloride injection (CFCI) and the other one is pial iontophoresis of ferric chloride (PIFC). Because Willmore did not give out the elaboration of the behaviors and electroencephalograms (EEGs) of the iron induced PTE animal models established by these two methods, so we have known little about these animal models. OBJECTIVE: To observe the behaviors and EEGs of the iron-induced PTE animal models established by PIFC and CFCI, in order to compare the differences and the study value of these two methods. DESIGN: Qualitative controlled observation tria SETTING: Department of Neurosurgery, Urumqi General Hospital, Lanzhou Military Area Command of Chinese PLA. MATERIALS: Forty healthy adult male SD rats, weighing 200 to 250 g, were involved in this experiment. Reagents and instruments: Ferric chloride (FeCl3·6H2O, Sigma USA), rat stereotaxic apparatus (ASI company, USA), the wireless blue tooth electroencephlograms recording system (Nuocheng electric Co.Ltd, Shanghai), a set of air turbine dental drill unit, dental base acrylic resin powder, microinjector (50 μL), amperemeter (1 mA), a pair of batteries, electric resistance (200 kΩ) , variable resistance (100 kΩ), tubule with endo-meridians of 2 mm (used as import tube), several silver wire segments and several acupuncture needles were employed in this study. METHODS: This study was carried out in the Experimental Animal Center of the Urumqi General Hospital, Lanzhou Military Area Command of Chinese PLA between November 2004 and April 2005. Establishing the PET animal models by CFCI method: Twenty SD rats were taken, intraperitoneally anesthetized with 50 mg/kg barbanylum and fixed on stereotaxic apparatus. A cranial burr hole with the diameter of 2 mm was drilled 3 mm behind the coronal suture and 2 mm lateral to the sagittal line on the left cranium. Another 5 cranial burr holes with diameter of 2 mm were drilled to place electrodes. The positions of holes were set that taking bregma as original point, sagittal line as Y-axis, the line through the original point and vertical to the Y-axis as X-axis. The unit of the coordinate axis was mm. The coordinate value of the electrodes were (4, 0), (4, -6), (-4, 0), (-4, -6), at last, a hole with the diameter of 2 mm was drilled on the center of the coronale. 5 μL ferric chloride solution (FeCl3, 100 mmol/L, pH 1.5) was injected into the sensorimotor cortex of rats using microinjector within 5 minutes. The needling depth was 3 mm. The needle was retained for 5 minutes so as to prevent the outflow of liquid. Establishing the PTE animal models by PIFC method: Twenty SD rats were chosen and weighed, and the procedures after weighing were as above.A cranial burr hole with the diameter of 4 mm was drilled in the position where needle inserted in animal models established by CFCI method. Cerebral dura mater was cut. Another 5 holes were drilled to place electrodes in the same position as above. The tip of tubule cotton stuffed inside (to prevent the rapid flow of FeCl3 solution, 100 mmol/L, pH 1.5) was gently connected to cerebral pia mater. The positive and negative electrodes of the amperemeter whose output current was 100 μA were connected to acupuncture needles. The acupuncture needle, which was connected to positive electrode, was inserted into ferric chloride solution, and that which was connected to negative electrode was inserted into the right forelimb of rats subcutaneously. The rats were galvanized for 10 minutes. Record of EEG: The silver wire with blunt anterior extremity was placed on the cerebral dura mater. Then, silver wire and cranial bones were firmly fixed with dental base acrylic resin power. The other side was connected to the wireless blue tooth electroencephlograms recording system to monitor EEG changes. Assessment criteria of seizure degree: Grade Ⅰ : "wet dog-like" shudder, facial muscle convulsion and chewing;Grade Ⅱ: rhythmical nodding:Grade Ⅲ: forelimb clonus:Grade Ⅳ: forelimb clonus while standing: Grade Ⅴ: lost the balance, vert, limb's convulsion and the whole body's tic. MAIN OUTCOME MEASURES: Behaviors and EEGs changes of iron-induced PTE animal models established by PTFC and CFCI. RESULTS: All the 40 rats were involved in the result analysis. (1) The changes of the behaviors: The two animal models both had the epileptic seizures. The epileptic seizure of the animal model established by PIFC mainly presented automatic behavior of chewing, and facial muscle convulsion accompanied with chewing. Epileptic seizure reached the peak within 2.5 to 7 hours after model establishing.It was gradually decreased within 24 hours and hardly seen 1 day after model establishing. The epileptic seizure of the rat model established by CFCI mainly presented turnover upspring and limbs' convulsion and urinary incontinence accompanied. The epileptic seizure reached the peak within 3 to 8 hours.It was relatively frequent within 1 week and gradually decreased within 2 weeks after model establishing. The PTE animal models established by CFCI were more closed to clinical PTE process. (2) The form of seizures: The epileptic seizures of the rat model established by PIFC mainly presented grade Ⅰ , seldom presented grades Ⅲ, Ⅳ and Ⅴ; The epileptic seizures of rat model established by CFCI mainly presented the head turning to the right, body's rotation, then appeared as grades Ⅳ and Ⅴ, and the whole procedure lasted 1 minute. At the interval of big seizures, grade Ⅰ was observed. From the respect of seizure manifestation, the PTE models established by CFCI were more similar to human PTE. (3) EEGs changes: The sharp waves with average frequency of 9.66 Hz and average amplitude of 183.90 μV were observed on the EEGs of the model established by PIFC when the rats were suffering seizures. The spike waves with average frequency of 16.01 Hz and average amplitude of 143.60 μV were observed on the EEGs of the model established by CFCI when the rats were suffering seizures. CONCLUSTON: (1)Iron-induced PTE rat model is stable and credible. (2)Compared with PTE animal model established by PIFC, PTE animal model established by CFCI is a chronic animal model, and its seizure manifestation is more similar to human PTE. so it is worth further studies.展开更多
Corrosion rate and anode polarization curves of electrodeposited RE-Ni-W-P-SiC-PTFE composite coating in various concentrations of phosphoric and ferric chloride were researched. The results show that corrosion rate o...Corrosion rate and anode polarization curves of electrodeposited RE-Ni-W-P-SiC-PTFE composite coating in various concentrations of phosphoric and ferric chloride were researched. The results show that corrosion rate of the composite coatings increases with the increasing concentrations of phosphoric and ferric chloride, and reaches the maximum value when phosphoric concentration is 40% and ferric chloride concentration is 20% (mass fraction, the same below if not mentioned). Anode polarization curves of the composite coatings show that anode polarization current density of the composite coatings heat-treated at 200 ℃ or 500 ℃ is lower than that of other coatings heat-treated at 300 ℃ or 400 ℃, which displays that the composite coatings heat-treated at 200 ℃ or 500 ℃ have better corrosion resistance. Besides, corrosion resistance of the composite coating heat-treated at 500 ℃ is better than that as deposited and RE-Ni-W-P-SiC composite coating heat-treated at 400 ℃, and is also better than that of 316L stainless steel.展开更多
Nickel leaching from low-grade nickel matte(LGNM) using aqueous ferric chloride solution was studied.The influence of factors such as leaching temperature and concentration of ferric chloride on the nickel leaching ra...Nickel leaching from low-grade nickel matte(LGNM) using aqueous ferric chloride solution was studied.The influence of factors such as leaching temperature and concentration of ferric chloride on the nickel leaching ratio was investigated.The results show that increasing leaching temperature and concentration of ferric chloride increases the nickel leaching ratio.The overall nickel leaching process follows the unreacted shrinking core model,and the surface chemical reaction is the rate-controlling step.The activation energy and the reaction order of the nickel leaching process,controlled by the surface chemical reaction,were calculated to be 52.96 kJ mol^(-1)and 0.5,respectively.Therefore,the kinetics equation for the nickel leaching was found to be 1-(1-α)^(1/3)=7.18×10~4C^(0.5)exp[-52,960/(RT)]t.展开更多
β-Keto acids are unstable to heat,acids,and bases,and have rarely been employed as carbon nucleophiles for the formation of carbon-carbon bonds.In this context,an efficient decarboxylative alkylation reaction of β-k...β-Keto acids are unstable to heat,acids,and bases,and have rarely been employed as carbon nucleophiles for the formation of carbon-carbon bonds.In this context,an efficient decarboxylative alkylation reaction of β-keto acids with benzylic alcohols has been developed,for the first time,through sequential cleavage of carbon-oxygen and carbon-carbon bonds.In the presence of 10 mol% of ferric chloride,a range of β-keto acids smoothly undergo decarboxylative alkylation with benzylic alcohols to give structurally diverse unsymmetric ketones in moderate to excellent yields and with extremely high regioselectivity.Preliminary mechanistic studies indicate that the reaction proceeds through an SN1 alkylation followed by decarboxylation.展开更多
基金Supported by the Major National Water Sci-Tech Projects of China(2009ZX07210-009)the Department of Environmental Protection of Shandong Province(2006032,2060403)
文摘This paper studied the effect of ferric chloride on waste sludge digestion,dewatering and sedimentation under the optimized doses in co-precipitation phosphorus removal process.The experimental results showed that the concentration of mixed liquid suspended solid(MLSS) was 2436 mg.L-1 and 2385 mg.L-1 in co-precipitation phosphorus removal process(CPR) and biological phosphorous removal process(BPR),respectively.The sludge reduction ratio for each process was 22.6% and 24.6% in aerobic digestion,and 27.6% and 29.9% in anaerobic digestion,respectively.Due to the addition of chemical to the end of aeration tank,the sludge content of CPR was slightly higher than that of BPR,but the sludge reduction rate for both processes had no distinct difference.The sludge volume index(SVI) and sludge specific resistance of BPR were 126 ml.g-1 and 11.7×1012 m.kg-1,respectively,while those of CPR were only 98 ml.g-1 and 7.1×1012 m.kg-1,indicating that CPR chemical could improve sludge settling and dewatering.
基金Project(BE2015628)supported by Jiangsu Province Science and Technology Support Program,China
文摘Considering that Fe,Al elements in bauxite residue are active components for water purification,an effective polyaluminum ferric chloride(PAFC)coagulant derived from bauxite residue,with Fe2O3 content>5.1%,Al2O3%>6.5%,basicity>65%,was successfully prepared.The effect of as-prepared PAFC on the zeta potential for printing and dyeing wastewater was investigated.Comparing with polyferric chloride(PFC)and polyferric sulfate(PFS)for printing and dyeing wastewater treatment,prepared bauxite residue-based PAFC exhibited the optimal performance in the aspects of chromaticity and chemical oxygen demand(COD)removal rate.Furthermore,the combination of bauxite residue-based PAFC and PFS for synergy coagulation of such wastewater demonstrated an obvious positive effect.With the proportion between as-prepared PAFC and PFS to be 2.5:1,the COD of treated wastewater could be further reduced to meet the national level A standard of China,providing a promising route to solve the problem of substandard printing and dyeing sewage outfall by a simple coagulation strategy.
基金Supported by the National Science Foundation of China。
文摘The kinetics of ferric chloride leaching of sphalerite in the microwave field has being studied in this paper.According to the experimental data,the rate of dissolution of sphalerite microwave irradiation heating is faster than that with conventional heating.The dissolution of sphalerite in the microwave field was investigated in different condition of temperature,concentration of FeCl,and particle size and a nonisothermal kinetic equation has being obtained.
文摘BACKGROUND: In order to study the pathogenesis of iron-induced posttraumatic epilepsy (PTE), foreign scholars have established several kinds of PTE animal models, among which, the iron- induced PTE animal models proposed by Willmore is the most famous. The iron-induced PTE animal models can be established by two methods: one is cortical ferric chloride injection (CFCI) and the other one is pial iontophoresis of ferric chloride (PIFC). Because Willmore did not give out the elaboration of the behaviors and electroencephalograms (EEGs) of the iron induced PTE animal models established by these two methods, so we have known little about these animal models. OBJECTIVE: To observe the behaviors and EEGs of the iron-induced PTE animal models established by PIFC and CFCI, in order to compare the differences and the study value of these two methods. DESIGN: Qualitative controlled observation tria SETTING: Department of Neurosurgery, Urumqi General Hospital, Lanzhou Military Area Command of Chinese PLA. MATERIALS: Forty healthy adult male SD rats, weighing 200 to 250 g, were involved in this experiment. Reagents and instruments: Ferric chloride (FeCl3·6H2O, Sigma USA), rat stereotaxic apparatus (ASI company, USA), the wireless blue tooth electroencephlograms recording system (Nuocheng electric Co.Ltd, Shanghai), a set of air turbine dental drill unit, dental base acrylic resin powder, microinjector (50 μL), amperemeter (1 mA), a pair of batteries, electric resistance (200 kΩ) , variable resistance (100 kΩ), tubule with endo-meridians of 2 mm (used as import tube), several silver wire segments and several acupuncture needles were employed in this study. METHODS: This study was carried out in the Experimental Animal Center of the Urumqi General Hospital, Lanzhou Military Area Command of Chinese PLA between November 2004 and April 2005. Establishing the PET animal models by CFCI method: Twenty SD rats were taken, intraperitoneally anesthetized with 50 mg/kg barbanylum and fixed on stereotaxic apparatus. A cranial burr hole with the diameter of 2 mm was drilled 3 mm behind the coronal suture and 2 mm lateral to the sagittal line on the left cranium. Another 5 cranial burr holes with diameter of 2 mm were drilled to place electrodes. The positions of holes were set that taking bregma as original point, sagittal line as Y-axis, the line through the original point and vertical to the Y-axis as X-axis. The unit of the coordinate axis was mm. The coordinate value of the electrodes were (4, 0), (4, -6), (-4, 0), (-4, -6), at last, a hole with the diameter of 2 mm was drilled on the center of the coronale. 5 μL ferric chloride solution (FeCl3, 100 mmol/L, pH 1.5) was injected into the sensorimotor cortex of rats using microinjector within 5 minutes. The needling depth was 3 mm. The needle was retained for 5 minutes so as to prevent the outflow of liquid. Establishing the PTE animal models by PIFC method: Twenty SD rats were chosen and weighed, and the procedures after weighing were as above.A cranial burr hole with the diameter of 4 mm was drilled in the position where needle inserted in animal models established by CFCI method. Cerebral dura mater was cut. Another 5 holes were drilled to place electrodes in the same position as above. The tip of tubule cotton stuffed inside (to prevent the rapid flow of FeCl3 solution, 100 mmol/L, pH 1.5) was gently connected to cerebral pia mater. The positive and negative electrodes of the amperemeter whose output current was 100 μA were connected to acupuncture needles. The acupuncture needle, which was connected to positive electrode, was inserted into ferric chloride solution, and that which was connected to negative electrode was inserted into the right forelimb of rats subcutaneously. The rats were galvanized for 10 minutes. Record of EEG: The silver wire with blunt anterior extremity was placed on the cerebral dura mater. Then, silver wire and cranial bones were firmly fixed with dental base acrylic resin power. The other side was connected to the wireless blue tooth electroencephlograms recording system to monitor EEG changes. Assessment criteria of seizure degree: Grade Ⅰ : "wet dog-like" shudder, facial muscle convulsion and chewing;Grade Ⅱ: rhythmical nodding:Grade Ⅲ: forelimb clonus:Grade Ⅳ: forelimb clonus while standing: Grade Ⅴ: lost the balance, vert, limb's convulsion and the whole body's tic. MAIN OUTCOME MEASURES: Behaviors and EEGs changes of iron-induced PTE animal models established by PTFC and CFCI. RESULTS: All the 40 rats were involved in the result analysis. (1) The changes of the behaviors: The two animal models both had the epileptic seizures. The epileptic seizure of the animal model established by PIFC mainly presented automatic behavior of chewing, and facial muscle convulsion accompanied with chewing. Epileptic seizure reached the peak within 2.5 to 7 hours after model establishing.It was gradually decreased within 24 hours and hardly seen 1 day after model establishing. The epileptic seizure of the rat model established by CFCI mainly presented turnover upspring and limbs' convulsion and urinary incontinence accompanied. The epileptic seizure reached the peak within 3 to 8 hours.It was relatively frequent within 1 week and gradually decreased within 2 weeks after model establishing. The PTE animal models established by CFCI were more closed to clinical PTE process. (2) The form of seizures: The epileptic seizures of the rat model established by PIFC mainly presented grade Ⅰ , seldom presented grades Ⅲ, Ⅳ and Ⅴ; The epileptic seizures of rat model established by CFCI mainly presented the head turning to the right, body's rotation, then appeared as grades Ⅳ and Ⅴ, and the whole procedure lasted 1 minute. At the interval of big seizures, grade Ⅰ was observed. From the respect of seizure manifestation, the PTE models established by CFCI were more similar to human PTE. (3) EEGs changes: The sharp waves with average frequency of 9.66 Hz and average amplitude of 183.90 μV were observed on the EEGs of the model established by PIFC when the rats were suffering seizures. The spike waves with average frequency of 16.01 Hz and average amplitude of 143.60 μV were observed on the EEGs of the model established by CFCI when the rats were suffering seizures. CONCLUSTON: (1)Iron-induced PTE rat model is stable and credible. (2)Compared with PTE animal model established by PIFC, PTE animal model established by CFCI is a chronic animal model, and its seizure manifestation is more similar to human PTE. so it is worth further studies.
基金Project([2002]24) supported by the National Development and Reform Commission of China
文摘Corrosion rate and anode polarization curves of electrodeposited RE-Ni-W-P-SiC-PTFE composite coating in various concentrations of phosphoric and ferric chloride were researched. The results show that corrosion rate of the composite coatings increases with the increasing concentrations of phosphoric and ferric chloride, and reaches the maximum value when phosphoric concentration is 40% and ferric chloride concentration is 20% (mass fraction, the same below if not mentioned). Anode polarization curves of the composite coatings show that anode polarization current density of the composite coatings heat-treated at 200 ℃ or 500 ℃ is lower than that of other coatings heat-treated at 300 ℃ or 400 ℃, which displays that the composite coatings heat-treated at 200 ℃ or 500 ℃ have better corrosion resistance. Besides, corrosion resistance of the composite coating heat-treated at 500 ℃ is better than that as deposited and RE-Ni-W-P-SiC composite coating heat-treated at 400 ℃, and is also better than that of 316L stainless steel.
基金financially supported by the National Basic Research Program of China (No.2014CB6434085)
文摘Nickel leaching from low-grade nickel matte(LGNM) using aqueous ferric chloride solution was studied.The influence of factors such as leaching temperature and concentration of ferric chloride on the nickel leaching ratio was investigated.The results show that increasing leaching temperature and concentration of ferric chloride increases the nickel leaching ratio.The overall nickel leaching process follows the unreacted shrinking core model,and the surface chemical reaction is the rate-controlling step.The activation energy and the reaction order of the nickel leaching process,controlled by the surface chemical reaction,were calculated to be 52.96 kJ mol^(-1)and 0.5,respectively.Therefore,the kinetics equation for the nickel leaching was found to be 1-(1-α)^(1/3)=7.18×10~4C^(0.5)exp[-52,960/(RT)]t.
基金supported by the National Natural Science Foundation of China (21172206,20972147,and J1030412)the National Basic Research Program of China (2010CB833300)the Program for Changjiang Scholars and Innovative Research Team in University (IRT1189)
文摘β-Keto acids are unstable to heat,acids,and bases,and have rarely been employed as carbon nucleophiles for the formation of carbon-carbon bonds.In this context,an efficient decarboxylative alkylation reaction of β-keto acids with benzylic alcohols has been developed,for the first time,through sequential cleavage of carbon-oxygen and carbon-carbon bonds.In the presence of 10 mol% of ferric chloride,a range of β-keto acids smoothly undergo decarboxylative alkylation with benzylic alcohols to give structurally diverse unsymmetric ketones in moderate to excellent yields and with extremely high regioselectivity.Preliminary mechanistic studies indicate that the reaction proceeds through an SN1 alkylation followed by decarboxylation.