期刊文献+
共找到486篇文章
< 1 2 25 >
每页显示 20 50 100
An Improved Repetitive Control Strategy for LCL Grid-Connected Inverter
1
作者 Ning He Chenlu Song +1 位作者 Feng Gao Cheng Qian 《Journal of Beijing Institute of Technology》 EI CAS 2022年第4期391-400,共10页
This paper proposes a cascade repetitive control strategy based on odd internal mode,and combines it with proportional-integral(PI)control to establish a compound repetitive control system for improving the quality of... This paper proposes a cascade repetitive control strategy based on odd internal mode,and combines it with proportional-integral(PI)control to establish a compound repetitive control system for improving the quality of grid connected current of LCL grid connected inverter.More specifically,the proposed method could effectively improve the control effect of grid-connected current of LCL inverter,restrain current harmonics and reduce the distortion rate of grid-connected current.Simulation experiment is conducted to verify the proposed repetitive control strategy,and the verification results show that,compared with traditional PI control,the proposed improved compound repetitive control strategy has a higher response speed,and the steady-state and dynamic performance have also been significantly improved. 展开更多
关键词 grid-connected inverter lcl filter harmonic suppression repetitive control
下载PDF
Design and Hardware-in-the-loop Validation:A Fractional Full Feed-forward Method for Grid Voltage in LCL Grid-connected Inverter Systems
2
作者 Qingyi Wang Binlei Ju +3 位作者 Yudi Lei Dan Zhou Shuai Yin Danyun Li 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2023年第5期1720-1731,共12页
The harmonic disturbance in the background grid is a problem that must be considered in the design of a gridconnected inverter.However,the full feed-forward method cannot completely suppress the harmonic disturbance i... The harmonic disturbance in the background grid is a problem that must be considered in the design of a gridconnected inverter.However,the full feed-forward method cannot completely suppress the harmonic disturbance in theory and is sensitive to noise.To tackle these problems,a fractional full feed-forward method of grid voltage is proposed in this paper.First,the mathematical model of the full feed-forward method is deduced,and the differences with the theoretical solution,which can suppress all harmonics,are analyzed.Then,the parameter equation,the harmonic suppression performance,stability analysis and the implementation process of this method are given.Compared with the full feed-forward method,the proposed method not only further improves the harmonic suppression performance,but also reduces the order of the mathematical model of the differential term in the feed-forward loop.In addition,the proposed method can be used to flexibly design feed-forward coefficients by selecting the order of suppressed harmonics.Finally,the proposed method is validated by a hardware-in-the-loop experiment on a MT real-time control platform NI PXIE-1071. 展开更多
关键词 Fractional differential full feed-forward method HARDWARE-IN-THE-LOOP lcl inverter
原文传递
Single Current Feedback Control Strategy for Grid-connected Inverters With LCL Filters 被引量:33
3
作者 CHEN Dong ZHANG Junming QIAN Zhaoming 《中国电机工程学报》 EI CSCD 北大核心 2013年第9期I0002-I0002,共1页
LCL滤波器广泛应用于并网逆变器系统中,其对高次谐波具有良好的衰减作用;但LCL滤波器为低阻尼三阶系统,容易发生谐振。传统的有源阻尼方法,通过对电容电流进行采样并反馈,能够抑制系统振荡,但增加了传感器数量。提出一种单电流反馈控制... LCL滤波器广泛应用于并网逆变器系统中,其对高次谐波具有良好的衰减作用;但LCL滤波器为低阻尼三阶系统,容易发生谐振。传统的有源阻尼方法,通过对电容电流进行采样并反馈,能够抑制系统振荡,但增加了传感器数量。提出一种单电流反馈控制策略,其采用入网电流两次微分的反馈方法,增加了系统阻尼,从而有效地抑制LCL滤波器的谐振尖峰,保证系统的稳定性;同时其对系统参数不敏感,并且不增加额外的传感器,是一种低成本高可靠性的控制策略。文中推导该控制策略下的系统传递函数,并分析系统的稳定性。最后,通过仿真和实验,验证提出的控制策略的可行性与有效性。 展开更多
关键词 并网逆变器 电流反馈 滤波器 控制策略 单路 三阶系统 主动阻尼 波衰减
原文传递
A Control Strategy for Grid-connected Inverters With LCL Filters 被引量:37
4
作者 HU Xuefeng WEI Zheng +2 位作者 CHEN Yihan GONG Chunying ZHANG Jiayan 《中国电机工程学报》 EI CSCD 北大核心 2012年第27期I0018-I0018,194,共1页
把LCL滤波器作为电压源型并网逆变器与电网的接口已受到广泛关注。与单电感L滤波器相比,利用电感值较小的LCL滤波器对入网电流的高次谐波具有显著的衰减效果,特别是在低开关频率的大功率并网逆变系统应用中更具明显优势,但是仅采用... 把LCL滤波器作为电压源型并网逆变器与电网的接口已受到广泛关注。与单电感L滤波器相比,利用电感值较小的LCL滤波器对入网电流的高次谐波具有显著的衰减效果,特别是在低开关频率的大功率并网逆变系统应用中更具明显优势,但是仅采用直接入网电流控制时,LCL滤波器接口的并网逆变器系统存在稳定性问题。该文采用电网侧电感电流和逆变侧电感电流双闭环控制策略对并网电流进行直接控制,电网侧电感电流作为外环更容易抑制并网电流的谐波因素,且可以直接控制入网电流的单位功率因数,采用逆变器侧电感电流作为内环可以增加系统阻尼,从而可抑制系统振荡,增加系统稳定性。对该方案进行系统建模,并深入分析了滤波器参数、控制器参数及系统稳定性之间的精确量化关系。仿真和实验结果表明,该控制策略既可有效抑制入网电流谐振和实现进网电流的高功率因数运行,同时又具有良好的稳态和动态性能。 展开更多
关键词 并网逆变器 控制策略 滤波器 供电网络 电流反馈 开关频率 三阶系统 谐波失真
原文传递
Dual-loop Control Strategy for Grid-connected Inverter with LCL Filter
5
作者 Qiubo Peng Hongbin Pan +1 位作者 Yong Liu Lidan Xiang 《Energy and Power Engineering》 2013年第4期97-101,共5页
As to the concrete topology of three-phase LCL type grid-connected inverter with damping resistance, mathematical model was deduced in detail, using method of equivalent transformation to the structure diagram, dampin... As to the concrete topology of three-phase LCL type grid-connected inverter with damping resistance, mathematical model was deduced in detail, using method of equivalent transformation to the structure diagram, damping resistance was virtualized, mathematical model under the DQ frame that can realize decoupling control was established, a dual-loop control strategy for grid-connected inverter with LCL filter was proposed, the system stability was analyzed and the design method of controller was given. The proposed method overcame the flaws of loss increase, efficiency reduce and cost increase which were caused by damping resistance in LCL type grid-connected inverter, the system efficiency and power supply quality of the output were improved. Feasibility and effectiveness of the new method were validated by simulation and experimental results. 展开更多
关键词 Virtual DAMPING lcl Filter THREE-PHASE grid-connected inverter DECOUPLING Control
下载PDF
Robust Dichotomy Solution-Based Model Predictive Control for the Grid-Connected Inverters with Disturbance Observer 被引量:5
6
作者 Huanyue Liao Xin Zhang Zhijun Ma 《CES Transactions on Electrical Machines and Systems》 CSCD 2021年第2期81-89,共9页
This paper proposes a robust dichotomy-based model predictive control(DS-MPC)with a fixed switching frequency for the grid-connected inverter(GCI).The proposed fast dichotomy algorithm can select and deduce the optima... This paper proposes a robust dichotomy-based model predictive control(DS-MPC)with a fixed switching frequency for the grid-connected inverter(GCI).The proposed fast dichotomy algorithm can select and deduce the optimal voltage vector dynamically through the space vector plane.Therefore,the proposed DS-MPC strategy could ensure dynamic performance and steady-state performance as well.Also,the current control robustness can be improved through DS-MPC with disturbance observer(DO)based on the extended Kalman filter(EKF).The novelty of this control is that the current control with fast dynamic response can be realized in the weak grid,even if the grid voltages are greatly distorted.Simulation and hardware experiments on the weak grid validate the effectiveness of the proposed DS-MPC with the EKF observer approach. 展开更多
关键词 Dichotomy solution-based model predictive control(DS-MPC) three-phase grid-connected inverter(GCI) weak grid voltage vector dichotomy
下载PDF
Grid-connected inverter for wind power generation system 被引量:1
7
作者 杨勇 阮毅 +2 位作者 沈欢庆 汤燕燕 杨影 《Journal of Shanghai University(English Edition)》 CAS 2009年第1期51-56,共6页
In wind power generation system the grid-connected inverter is an important section for energy conversion and transmission, of which the performance has a direct influence on the entire wind power generation system. T... In wind power generation system the grid-connected inverter is an important section for energy conversion and transmission, of which the performance has a direct influence on the entire wind power generation system. The mathematical model of the grid-connected inverter is deduced firstly. Then, the space vector pulse width modulation (SVPWM) is analyzed. The power factor can be controlled close to unity, leading or lagging, which is realized based on H-type current controller and grid voltage vector-oriented control. The control strategy is verified by the simulation and experimental results with a good sinusoidal current, a small harmonic component and a fast dynamic response. 展开更多
关键词 grid-connected inverter space vector pulse width modulation (SVPWM) grid voltage vector-oriented power factor
下载PDF
Coordination of multiple grid-connected inverters for harmonic compensation
8
作者 郭晓瑞 郭吉丰 王剑 《Journal of Central South University》 SCIE EI CAS 2014年第8期3126-3132,共7页
For multiple grid-connected inverters with active filter function,it makes sense to regulate every unit to output maximum active power from photovoltaic arrays,as well as eliminate the harmonic due to the non-linear l... For multiple grid-connected inverters with active filter function,it makes sense to regulate every unit to output maximum active power from photovoltaic arrays,as well as eliminate the harmonic due to the non-linear loads connected to the electric networks.Naturally,a centralized control coordination strategy was proposed for the purpose of high facility utilization,good harmonic compensation ability and unwanted overcompensation condition.Based on a vector decoupling control scheme and generalized instantaneous reactive power theory,the solution was to allocate the harmonic eliminating task for every inverter according to the instantaneous power margin of each.The grid current always keeps sinusoidal in spite of non-linear load change and output active power change for any inverter.The simulation results validate the efficacy of the proposed coordination strategy. 展开更多
关键词 active filter HARMONICS grid-connected inverter decoupling control COORDINATION
下载PDF
Topology for current-source grid-connected inverter with improved effciency and pulse width modulation control strategy
9
作者 吴春华 陈国呈 +3 位作者 崔开涌 陈卫民 肖鹏 张翼 《Journal of Shanghai University(English Edition)》 CAS 2008年第6期554-559,共6页
A novel topology of the current-source grid-connected inverter is proposed based on the immittance converter theory. A control strategy of sine-sine pulse width modulation (PWM) is studied. Compared with the traditi... A novel topology of the current-source grid-connected inverter is proposed based on the immittance converter theory. A control strategy of sine-sine pulse width modulation (PWM) is studied. Compared with the traditional current-source inverter, the power frequency inductors and power frequency transformer are replaced with high frequency inductors and a high frequency transformer. Thus, the proposed inverter has advantages of small volume, low cost, low total harmonic distortion (THD), low power losses, high power factor (PF) and simple control. Furthermore, grid voltage cannot influence output current of the grid-connected inverter and the current-source inverter with a high PF that approaches one has been realized. Finally, validity of the theory analysis and feasibility of the control scheme are shown by simulation and experimental results. 展开更多
关键词 grid-connected current-source inverter immittance converter
下载PDF
Quasi-Z Source Inverter Control of PV Grid-Connected Based on Fuzzy PCI
10
作者 Tao Hou Chen-Yang Zhang Hong-Xia Niu 《Journal of Electronic Science and Technology》 CAS CSCD 2021年第3期274-286,共13页
The photovoltaic grid-connected inverter is an important interface between the photovoltaic power generation system and power grid.Its high-quality operation is directly related to the output power quality of the powe... The photovoltaic grid-connected inverter is an important interface between the photovoltaic power generation system and power grid.Its high-quality operation is directly related to the output power quality of the power grid.In order to further optimize the control effect of the quasi-Z source grid-connected photovoltaic inverter,a fuzzy proportional complex integral control(PCI)method is proposed for the current internal loop control.This method can eliminate the steady-state error,and has the characteristic of zero steady-state error adjustment for the AC disturbance signal of a specific frequency.The inductance-capacitance-inductance(LCL)filter is adopted in the grid-connected circuit,and the feedback capacitive current is taken as the control variable of the inner loop to form the active damping control method,which can not only effectively suppress the resonance of the LCL circuit,but also significantly inhibit the high-order harmonics in the grid-connected current.Finally,a system simulation model is built in MATLAB/Simulink to verify the superiority and effectiveness of the proposed method. 展开更多
关键词 Frequency of harmonic distortion fuzzy proportional complex integral inductance-capacitance-inductance(lcl)filtering circuit photovoltaic grid-connection quasi-Z source inverter
下载PDF
FCS-MPC Strategy for PV Grid-Connected Inverter Based on MLD Model
11
作者 Xiaojuan Lu Qingbo Zhang 《Energy Engineering》 EI 2021年第6期1729-1740,共12页
In the process of grid-connected photovoltaic power generation,there are high requirements for the quality of the power that the inverter breaks into the grid.In this work,to improve the power quality of the grid-conn... In the process of grid-connected photovoltaic power generation,there are high requirements for the quality of the power that the inverter breaks into the grid.In this work,to improve the power quality of the grid-connected inverter into the grid,and the output of the system can meet the grid-connected requirements more quickly and accurately,we exhibit an approach toward establishing a mixed logical dynamical(MLD)model where logic variables were introduced to switch dynamics of the single-phase photovoltaic inverters.Besides,based on the model,our recent efforts in studying the finite control set model predictive control(FCS-MPC)and devising the output current full state observer are exciting for several advantages,including effectively avoiding the problem of the mixed-integer quadratic programming(MIQP),lowering the THD value of the output current of the inverter circuit,improving the quality of the power that the inverter breaks into the grid,and realizing the current output and the grid voltage same frequency and phase to meet grid connection requirements.Finally,the effectiveness of the mentioned methods is verified by MATLAB/Simulink simulation. 展开更多
关键词 Photovoltaic grid-connected inverter hybrid logic dynamic model finite control set model predictive control full state observer
下载PDF
The improved PAC method for a three-phase PWM grid-connected inverter
12
作者 李杰 马祎炜 +2 位作者 陈国呈 王得利 俞俊杰 《Journal of Shanghai University(English Edition)》 CAS 2008年第6期560-564,共5页
In this paper, a vector regulating principle of the phase and amplitude control PAC method for three-phase grid-connected inverters is presented.To solve the problem of heavy inrush current and slow dynamic response w... In this paper, a vector regulating principle of the phase and amplitude control PAC method for three-phase grid-connected inverters is presented.To solve the problem of heavy inrush current and slow dynamic response when system starts up, the starting voltage prediction control and the current feed-forward control are proposed and used, which improve the dynamic performance of the system in the PAC.The experimental results carried out on a three-phase grid-connected inverter proved the validity of the proposed method. 展开更多
关键词 three-phase pulse width modulation (PWM) grid-connected inverter phase and amplitude control (PAC) starting voltage prediction control current feed-forward control
下载PDF
A Simulation Research on the Grid-Connected Control Technology of Single-Phase Inverters Based on MATLAB
13
作者 Jinjie Chen 《Journal of Electronic Research and Application》 2022年第4期7-12,共6页
This paper primarily discusses the main circuit of single-phase inverter circuits.It begins by introducing the research context and the significance of the subject,then discusses the topology of grid-connected single-... This paper primarily discusses the main circuit of single-phase inverter circuits.It begins by introducing the research context and the significance of the subject,then discusses the topology of grid-connected single-phase inverter circuits,continues by discussing the control strategy for grid-connected single-phase inverter circuits,realizes a sinusoidal pulse width modulation(SPWM)signal generation circuit and an inverse control algorithm program,and finally ensures good output waveform and fast dynamic response.In view of the hysteresis feature of the grid voltage’s synchronous signal sampling circuit,the acquisition function in digital signal processing(DSP)control chips is applied,and the reasons for the hysteresis phenomenon are thoroughly investigated.The reliability of the SPWM control algorithm is revealed through the results. 展开更多
关键词 Solar energy Photovoltaic power generation grid-connected inverter circuit MATLAB simulation
下载PDF
基于双二阶滤波器的LCL型并网逆变器延时补偿方法
14
作者 赵铁英 李俊然 +1 位作者 高宁 田培建 《电力系统保护与控制》 EI CSCD 北大核心 2024年第8期145-157,共13页
为了抑制LCL型滤波器的谐振尖峰,电容电流反馈有源阻尼被广泛应用于LCL型并网逆变器中。由于数字控制延时带来的不利影响,电容电流反馈有源阻尼的阻尼性能被严重削弱。负阻尼区域出现在f_(s)/6到f_(s)/2之间,减弱了并网逆变器的稳定性... 为了抑制LCL型滤波器的谐振尖峰,电容电流反馈有源阻尼被广泛应用于LCL型并网逆变器中。由于数字控制延时带来的不利影响,电容电流反馈有源阻尼的阻尼性能被严重削弱。负阻尼区域出现在f_(s)/6到f_(s)/2之间,减弱了并网逆变器的稳定性和对电网阻抗变化下的鲁棒性。在电容电流反馈通道上插入一个双二阶滤波器来补偿数字控制延时带来的相位滞后,正阻尼范围可以扩展到f_(s)/3,从而实现了对电网阻抗变化的高鲁棒性。选择了合适的离散化方法,分析了补偿后的系统稳定性。提出了一个详细的闭环参数设计流程,以获得良好的控制性能。最后,实验结果验证所提方法的有效性和参数设计流程的可行性。 展开更多
关键词 有源阻尼 并网逆变器 lcl滤波器 延时补偿 正阻尼范围 弱电网
下载PDF
全驱系统理论在LCL并网逆变器中的控制及应用
15
作者 郑雪梅 郅济荣 +1 位作者 张星宇 李其恩 《长春工业大学学报》 CAS 2024年第2期125-129,共5页
利用系统固有的全驱特性可将系统数学模型化为全驱模型,大大简化控制器的设计。文中建立了LCL滤波器全驱系统的数学模型,并推导出其控制率,通过仿真验证了控制的稳定性。
关键词 lcl 全驱系统 逆变器
下载PDF
附加虚拟阻抗的LCL型并网逆变器电流扰动观测控制方法
16
作者 朱红萍 郭利文 +2 位作者 钱万明 朱泓知 韩迎龙 《湖南电力》 2024年第2期35-43,共9页
针对LCL型并网逆变器输出电流质量容易受电网电压背景谐波及在弱电网条件下电网阻抗的影响,提出一种附加虚拟阻抗的LCL型并网逆变器电流扰动观测控制方法。首先,在常规双闭环控制的基础上引入扰动观测器,将电网电压背景谐波视为系统外... 针对LCL型并网逆变器输出电流质量容易受电网电压背景谐波及在弱电网条件下电网阻抗的影响,提出一种附加虚拟阻抗的LCL型并网逆变器电流扰动观测控制方法。首先,在常规双闭环控制的基础上引入扰动观测器,将电网电压背景谐波视为系统外部扰动,利用扰动观测器实时估算出扰动量并前馈补偿动态消除扰动对系统的影响;其次通过阻抗分析法来分析弱电网系统中电网阻抗引起稳定性下降的问题,在电流扰动观测控制方法的基础上再加入虚拟阻抗进行优化设计,使得并网阻抗在阻抗交截频率较大范围内变化时的相角裕度仍然大于系统所约束的稳定裕度。仿真对比结果表明,所提方法在保持良好的电流质量的同时提高了系统对电网阻抗的鲁棒性。 展开更多
关键词 lcl型并网逆变器 扰动观测器 虚拟阻抗 电流质量 鲁棒性
下载PDF
弱电网下LCL逆变器的有源阻尼控制策略研究
17
作者 王翰文 曾成碧 苗虹 《电源学报》 CSCD 北大核心 2024年第2期167-174,共8页
在弱电网中,由于电网阻抗的存在,会导致新能源并网LCL滤波器固有谐振频率发生偏移,传统有源阻尼控制策略则无法保证系统的稳定性。而且随着新能源发电在电力系统中的占比不断提高,如何降低运营成本成为了研究热点。因此本文提出一种基... 在弱电网中,由于电网阻抗的存在,会导致新能源并网LCL滤波器固有谐振频率发生偏移,传统有源阻尼控制策略则无法保证系统的稳定性。而且随着新能源发电在电力系统中的占比不断提高,如何降低运营成本成为了研究热点。因此本文提出一种基于并网电流和公共耦合电压反馈的新型控制策略,该控制策略不仅提供了有源阻尼以抑制LCL谐振,而且减少了传感器的使用,还能对大范围变化的电网阻抗有较强的适应能力。通过仿真和实验表明,与传统的控制策略相比,在改进的策略下弱电网的实用范围增加,系统的稳定性得到提高,对谐波的抑制能力提升,并网电流质量有了良好的改善。 展开更多
关键词 弱电网 lcl滤波器 并网逆变器 有源阻尼
下载PDF
基于H_(∞)滤波器的LCL型并网逆变器有源阻尼方法
18
作者 陈润 曾君 刘俊峰 《电源学报》 CSCD 北大核心 2024年第4期121-132,共12页
LCL型滤波器具有优越的高频谐波抑制性能,但会造成谐振和稳定性问题。对于LCL型并网逆变器,传统的电容电流反馈型有源阻尼方法能有效抑制谐振尖峰,但是需要额外的电流传感器。为此,提出一种基于H_(∞)滤波器的新型有源阻尼控制策略。根... LCL型滤波器具有优越的高频谐波抑制性能,但会造成谐振和稳定性问题。对于LCL型并网逆变器,传统的电容电流反馈型有源阻尼方法能有效抑制谐振尖峰,但是需要额外的电流传感器。为此,提出一种基于H_(∞)滤波器的新型有源阻尼控制策略。根据LCL型滤波器状态空间模型及过程噪声模型完成H_(∞)滤波器的求解,可利用入网电流和公共耦合点电压信息估计滤波电容电流并完成反馈,增大系统阻尼,即使LCL型滤波器参数发生摄动也仍能保持估计值的精确度。仿真和实验结果表明,该方法对LCL滤波器参数变化和电网阻抗变化不敏感,验证了该方法的可行性和优势。 展开更多
关键词 lcl型滤波器 并网逆变器 有源阻尼 H_∞滤波器
下载PDF
弱电网下LCL型并网逆变器高鲁棒性并网电流反馈有源阻尼策略
19
作者 董光德 徐泽众 +2 位作者 孙鹏菊 李强 陈咏涛 《电网技术》 EI CSCD 北大核心 2024年第4期1672-1680,I0081,共10页
并网电流反馈有源阻尼(grid-current-feedback-active-damping,GCFAD)策略可以在不增加额外传感器的前提下,有效抑制LCL型并网逆变器的谐振尖峰。在电网电压畸变的工况下,GCFAD策略往往与电网电压前馈策略同时使用以改善并网电流质量。... 并网电流反馈有源阻尼(grid-current-feedback-active-damping,GCFAD)策略可以在不增加额外传感器的前提下,有效抑制LCL型并网逆变器的谐振尖峰。在电网电压畸变的工况下,GCFAD策略往往与电网电压前馈策略同时使用以改善并网电流质量。然而,通过研究发现,传统GCFAD策略等效虚拟阻抗在中低频段的正阻特性会导致并网逆变器输出阻抗在中频段产生一定的相位滞后,从而降低了系统在电网电压畸变且附加电网电压前馈策略的情况下,对电网阻抗变化的鲁棒性。为了解决这一问题,提出了一种高鲁棒性并网电流反馈有源阻尼(high robustness grid-current-feedback-active-damping,HR-GCFAD)策略,使虚拟阻抗在高频处呈现正阻特性以抑制LCL谐振尖峰,增强了系统的稳定性;在中低频段呈现负阻特性以提高系统中频段输出阻抗相位,进而提高了系统在附加电网电压前馈策略时对电网阻抗变化的鲁棒性。理论分析和实验结果充分验证了所提策略的有效性。 展开更多
关键词 lcl型并网逆变器 有源阻尼 鲁棒性 并网电流反馈
原文传递
Control strategy of LCL-type three-phase photovoltaic grid connected inverter 被引量:2
20
作者 WANG Si-hua WANG Jin-qiang 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2019年第3期254-265,共12页
The grid-connected inverter with LCL filter has the ability of easily attenuating high-frequency current harmonics. However, its suppression effect on the background harmonics in grid voltage is limited. A control str... The grid-connected inverter with LCL filter has the ability of easily attenuating high-frequency current harmonics. However, its suppression effect on the background harmonics in grid voltage is limited. A control strategy is presented, which is composed of an inner loop of capacitor current feedforward, an outer loop of grid-current feedforward and feedforward of grid voltage. The limitations and steps of parameters design for LCL filter are analyzed. Meanwhile, the capacitor current loop is employed to damp the resonant peak caused by the LCL filter and enhance the stability. The properties of different controllers are analyzed and compared, thereinto quasi-proportional-rasonant (PR) controller realizes the control with zero steady-state error of AC variables in static coordinates. In order to suppress the current distortion effected by the background harmonics in grid voltage, the feed-forward function is calculated for the grid-connected inverter with an LCL filter. After simplifying the block diagram, a full-feedforward control strategy for grid voltage is proposed. Theoretical analysis and Matlab/Simulink simulation results show that the proposed method has the advantages of high steady accuracy, fast dynamic response and strong robustness. 展开更多
关键词 three-phase grid-connected inverter lcl filter active damping quasi-proportional-resonant (PR) control full-feedforward of grid voltages
下载PDF
上一页 1 2 25 下一页 到第
使用帮助 返回顶部