期刊文献+
共找到468篇文章
< 1 2 24 >
每页显示 20 50 100
Determination of Ten Kinds of Alpha-2 Agonists Residues in Animal Derived Food by UHPLC-Triple Quadrupole/Composite Linear Ion Trap Mass Spectrometry
1
作者 Fang LI Xuemei LI +3 位作者 Xiangang LI Sining LIU Sha LIU Ying WANG 《Plant Diseases and Pests》 2024年第1期28-32,共5页
[Objectives]The paper was to establish an ultra high performance liquid chromatography-quadrupole/linear ion trap complex mass spectrometry for the determination of 10 kinds ofα2-receptor agonists in animal derived f... [Objectives]The paper was to establish an ultra high performance liquid chromatography-quadrupole/linear ion trap complex mass spectrometry for the determination of 10 kinds ofα2-receptor agonists in animal derived food.[Methods]The samples were extracted with sodium carbonate buffer solution and ethyl acetate,and analyzed by mass spectrometry after solid phase extraction and high performance liquid chromatography separation.[Results]Ten kinds ofα2-receptor agonists showed a good linear relationship in the range of 1-100μg/mL,with the average recovery of over 69%and the relative standard deviation less than 8.32%.The detection limit of 10 kinds of α_(2)-receptor agonists was up to 1μg/kg.[Conclusions]The method has good selectivity and strong anti-interference ability,and can meet the requirements of 10 kinds ofα2-receptor agonists residues in animal derived food. 展开更多
关键词 Animal derived food α_(2)-receptor agonist Solid-phase extraction Ultra-high performance liquid phase-triple quadrupole/linear ion trap composite mass spectrometry
下载PDF
Research on the Upper Limit of Accuracy for Predicting Theoretical Tandem Mass Spectrometry
2
作者 Changjiu He Xiaoyu Wang +1 位作者 Mingming Lyu Xinye Bian 《Journal of Computer and Communications》 2024年第3期184-195,共12页
In recent years, numerous theoretical tandem mass spectrometry prediction methods have been proposed, yet a systematic study and evaluation of their theoretical accuracy limits have not been conducted. If the accuracy... In recent years, numerous theoretical tandem mass spectrometry prediction methods have been proposed, yet a systematic study and evaluation of their theoretical accuracy limits have not been conducted. If the accuracy of current methods approaches this limit, further exploration of new prediction techniques may become redundant. Conversely, a need for more precise prediction methods or models may be indicated. In this study, we have experimentally analyzed the limits of accuracy at different numbers of ions and parameters using repeated spectral pairs and integrating various similarity metrics. Results show significant achievements in accuracy for backbone ion methods with room for improvement. In contrast, full-spectrum prediction methods exhibit greater potential relative to the theoretical accuracy limit. Additionally, findings highlight the significant impact of normalized collision energy and instrument type on prediction accuracy, underscoring the importance of considering these factors in future theoretical tandem mass spectrometry predictions. 展开更多
关键词 Tandem mass spectrometry Spectral Prediction Theoretical Limit
下载PDF
Spatiotemporal pharmacometabolomics based on ambient mass spectrometry imaging to evaluate the metabolism and hepatotoxicity of amiodarone in HepG2 spheroids 被引量:2
3
作者 Limei Li Qingce Zang +5 位作者 Xinzhu Li Ying Zhu Shanjing Wen Jiuming He Ruiping Zhang Zeper Abliz 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2023年第5期483-493,共11页
Three-dimensional(3D)cell spheroid models combined with mass spectrometry imaging(MSI)enables innovative investigation of in vivo-like biological processes under different physiological and pathological conditions.Her... Three-dimensional(3D)cell spheroid models combined with mass spectrometry imaging(MSI)enables innovative investigation of in vivo-like biological processes under different physiological and pathological conditions.Herein,airflow-assisted desorption electrospray ionization-MSI(AFADESI-MSI)was coupled with 3D HepG2 spheroids to assess the metabolism and hepatotoxicity of amiodarone(AMI).High-coverage imaging of>1100 endogenous metabolites in hepatocyte spheroids was achieved using AFADESI-MSI.Following AMI treatment at different times,15 metabolites of AMI involved in Ndesethylation,hydroxylation,deiodination,and desaturation metabolic reactions were identified,and according to their spatiotemporal dynamics features,the metabolic pathways of AMI were proposed.Subsequently,the temporal and spatial changes in metabolic disturbance within spheroids caused by drug exposure were obtained via metabolomic analysis.The main dysregulated metabolic pathways included arachidonic acid and glycerophospholipid metabolism,providing considerable evidence for the mechanism of AMI hepatotoxicity.In addition,a biomarker group of eight fatty acids was selected that provided improved indication of cell viability and could characterize the hepatotoxicity of AMI.The combination of AFADESI-MSI and HepG2 spheroids can simultaneously obtain spatiotemporal information for drugs,drug metabolites,and endogenous metabolites after AMI treatment,providing an effective tool for in vitro drug hepatotoxicity evaluation. 展开更多
关键词 mass spectrometry imaging HepG2 spheroids HEPATOTOXICITY Drug metabolism AMIODARONE
下载PDF
Evaluation of allergenic protein profiles in three Chinese high-oleic acid peanut cultivars using NanoLC-Orbitrap mass spectrometry 被引量:1
4
作者 Xinke Yang Haochen Bai +3 位作者 Lijun Yin Jin Wang Wentong Xue Xin Jia 《Food Science and Human Wellness》 SCIE CSCD 2023年第3期851-860,共10页
High oleic-acid peanuts are known for their pre-longed shelf-life and health benefit due to high content of oleic fatty acid.However,the allergenicity and allergenic protein profiles in Chinese high-oleic peanuts have... High oleic-acid peanuts are known for their pre-longed shelf-life and health benefit due to high content of oleic fatty acid.However,the allergenicity and allergenic protein profiles in Chinese high-oleic peanuts have yet to be studied.For this purpose,an Orbitrap Fusion mass spectrometry(MS)-based method that is feasible for identification of putative allergenic protein as well as semi-quantitation of five major allergen protein in three different Chinese high-oleic peanut cultivars(JH 13,JH 16 and JH 18)have been reported.Results show that three Chinese high-oleic acid peanut cultivars selected all contained highly allergenic proteins Ara h1,Ara h 2,Ara h 3 and Ara h 6.The allergenic protein profiles of Chinese high-oleic acid peanut cultivars were very similar to that of conventional peanuts,but the allergenic protein subunits varied greatly among higholeic peanuts.Additionally,a comprehensive peptide-filtering pipeline had been developed for identification of potential peptide markers in peanut allergen proteins.Through the peptide-filtering pipeline,three novel peptide markers,IVQIEAKPNTLVLPK,SSNPDIYNPQAGSLR and AQSENYEYLAFK surrogate to Ara h 1,Ara h 3 with high abundance,good MS response and highly reliability were identified,which can be used as candidate peptide markers for the detection of peanut allergens in different food matrices. 展开更多
关键词 ALLERGY High-oleic acid peanut Peptide-filtering pipeline NanoLC-Orbitrap mass spectrometry
下载PDF
Nylon 6-cellulose composite hosted in a hypodermic needle: Biofluid extraction and analysis by ambient mass spectrometry in a single device
5
作者 Jaime Millan-Santiago Rafael Lucena Soledad Cardenas 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2023年第11期1346-1352,共7页
This study proposes a hypodermic needle(HN)as a sorbent holder and an electrospray(ESI)emitter,thus combining extraction and analysis in a single device.A novel nylon 6-cellulose(N6-Cel)composite sorbent is proposed t... This study proposes a hypodermic needle(HN)as a sorbent holder and an electrospray(ESI)emitter,thus combining extraction and analysis in a single device.A novel nylon 6-cellulose(N6-Cel)composite sorbent is proposed to extract methadone from oral fluid samples.The cellulosic substrate provides the composite with high porosity,permitting the flow-through of the sample,while the polyamide contributes to the extraction of the analyte.The low price of the devices(considering the holder and the sorbent)contributes to the affordability of the method,and their small size allows easy transportation,opening the door to on-site extractions.Under the optimum conditions,the analyte can be determined by high-resolution ambient ionization mass spectrometry at a limit of detection(LOD)as low as 0.3 mg/L and precision(expressed as relative standard deviation,RSD)better than 9.3%.The trueness,expressed as relative recovery(RR),ranged from 90%to 109%.As high-resolution mass spectrometers are not available in many laboratories,the method was also adapted to low-resolution spectrometers.In this sense,the direct infusion of the eluates in a triple quadrupole-mass spectrometry provided an LOD of 2.2 mg/L.The RSD was better than 5.3%,and the RR ranged from 96%to 121%. 展开更多
关键词 ESI emitter mass spectrometry Hypodermic needle COMPOSITE METHADONE
下载PDF
Comparison of different approaches for direct coupling of solid-phase microextraction to mass spectrometry for drugs of abuse analysis in plasma
6
作者 Wei Zhou Martyna N.Wieczorek +1 位作者 Runshan Will Jiang Janusz Pawliszyn 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2023年第2期216-222,共7页
The direct coupling of solid-phase microextraction(SPME)to mass spectrometry(MS)(SPME-MS)has proven to be an effective method for the fast screening and quantitative analysis of compounds in complex matrices such as b... The direct coupling of solid-phase microextraction(SPME)to mass spectrometry(MS)(SPME-MS)has proven to be an effective method for the fast screening and quantitative analysis of compounds in complex matrices such as blood and plasma.In recent years,our lab has developed three novel SPME-MS techniques:SPME-microfluidic open interface-MS(SPME-MOI-MS),coated blade spray-MS(CBS-MS),and SPME-probe electrospray ionization-MS(SPME-PESI-MS).The fast and high-throughput nature of these SPME-MS technologies makes them attractive options for point-of-care analysis and anti-doping testing.However,all these three techniques utilize different SPME geometries and were tested with different MS instruments.Lack of comparative data makes it difficult to determine which of these methodologies is the best option for any given application.This work fills this gap by making a comprehensive comparison of these three technologies with different SPME devices including SPME fibers,CBS blades,and SPME-PESI probes and SPME-liquid chromatography-MS(SPME-LC-MS)for the analysis of drugs of abuse using the same MS instrument.Furthermore,for the first time,we developed different desorption chambers for MOI-MS for coupling with SPME fibers,CBS blades,and SPME-PESI probes,thus illustrating the universality of this approach.In total,eight analytical methods were developed,with the experimental data showing that all the SPME-based methods provided good analytical performance with R^(2)of linearities larger than 0.9925,accuracies between 81%and 118%,and good precision with an RSD%≤13%. 展开更多
关键词 Solid-phase microextraction mass spectrometry Microfluidic open interface Coated blade spray Probe electrospray ionization Drug of abuse
下载PDF
Tracking gassing behavior in pouch cell by operando on-line electrochemical mass spectrometry
7
作者 Haitang Zhang Jianken Chen +10 位作者 Baodan Zhang Xiaohong Wu Zhengang Li Leiyu Chen Junhao Wang Xiaoyu Yu Haiyan Luo Jiyuan Xue Yu-Hao Hong Yu Qiao Shi-Gang Sun 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2023年第9期286-291,共6页
As the rapid development of more powerful and safer lithiumion batteries, the mechanism study of gases evolution is attacking more and more attention in recent years. Especially under overcharge/discharge and/or high-... As the rapid development of more powerful and safer lithiumion batteries, the mechanism study of gases evolution is attacking more and more attention in recent years. Especially under overcharge/discharge and/or high-temperature working condition. 展开更多
关键词 Pouch cell Operando characterization mass spectrometry Lithium-ion batteries Gassing behavior
下载PDF
Identification,structure elucidation and origin of a common pyridinium-thiocyanate intermediate in electrospray mass spectrometry among the benziamidazole-class proton pump inhibitors
8
作者 Dong Sun Chunyu Wang +1 位作者 Yanxia Fan Jingkai Gu 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2023年第6期683-688,共6页
During the analysis of benziamidazole-class irreversible proton pump inhibitors,an unusual mass spectral response with the mass-to-charge ratio at[Mt10]t intrigued us,as it couldn't be assigned to any literature k... During the analysis of benziamidazole-class irreversible proton pump inhibitors,an unusual mass spectral response with the mass-to-charge ratio at[Mt10]t intrigued us,as it couldn't be assigned to any literature known relevant structure,intermediate or adduct ion.Moreover,this mysterious mass pattern of[Mt10]t has been gradually observed by series of marketed proton pump inhibitors,viz.omeprazole,pantoprazole,lansoprazole and rabeprazole.All the previous attempts to isolate the corresponding component were unsuccessful.The investigation of present work addresses this kind of signal to a pyridinium thiocyanate mass spectral intermediate(10),which is the common fragment ion of series of labile aggregates.The origin of such aggregates can be traced to the reactive intermediates formed by acid-promoted degradation.These reactive intermediates tend to react with each other and give raise series of complicated aggregates systematically in a water/acetonitrile solution by electrospray ionization.The structure of the corresponding pyridinium thiocyanate species of omeprazole(10a)has been eventually characterized with the help of synthetic specimen(10a′).Our structural proposal as well as its origin was supported by in situ nuclear magnetic resonance,chemical derivatization and colorimetric experiments. 展开更多
关键词 Proton pump inhibitor mass spectrometry Electrospray ionization Pseudo-molecular ion Pyridinium thiocyanate
下载PDF
Rapid authentication of different herbal medicines by heating online extraction electrospray ionization mass spectrometry
9
作者 Zidong Qiu Chaofa Wei +9 位作者 Xiang Li Changjiangsheng Lai Zhilai Zhan Yan Jin Li Zhou Qingxiu Hao Jian Yang Shuanglong Wang Liping Kang Luqi Huang 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2023年第3期296-304,共9页
The rapid and accurate authentication of traditional Chinese medicines(TCMs)has always been a key scientific and technical problem in the field of pharmaceutical analysis.Herein,a novel heating online extraction elect... The rapid and accurate authentication of traditional Chinese medicines(TCMs)has always been a key scientific and technical problem in the field of pharmaceutical analysis.Herein,a novel heating online extraction electrospray ionization mass spectrometry(H-oEESI-MS)was developed for the rapid and direct analysis of extremely complex substances without the requirement for any sample pretreatment or pre-separation steps.The overall molecular profile and fragment structure features of various herbal medicines could be completely captured within 10–15 s,with minimal sample(<0.5 mg)and solvent consumption(<20μL for one sample).Furthermore,a rapid differentiation and authentication strategy for TCMs based on H-oEESI-MS was proposed,including metabolic profile characterization,characteristic marker screening and identification,and multivariate statistical analysis model validation.In an analysis of 52 batches of seven types of Aconitum medicinal materials,20 and 21 key compounds were screened out as the characteristic markers of raw and processed Aconitum herbal medicines,respectively,and the possible structures of all the characteristic markers were comprehensively identified based on Compound Discoverer databases.Finally,multivariate statistical analysis showed that all the different types of herbal medicines were well differentiated and identified(R^(2)X>0.87,R^(2)Y>0.91,and Q^(2)>0.72),which further verified the feasibility and reliability of this comprehensive strategy for the rapid authentication of different TCMs based on H-oEESI-MS.In summary,this rapid authentication strategy realized the ultra-high-throughput,low-cost,and standardized detection of various complex TCMs for the first time,thereby demonstrating wide applicability and value for the development of quality standards for TCMs. 展开更多
关键词 Heating online extraction electrospray ionization mass spectrometry Rapid authentication Traditional Chinese medicine
下载PDF
Determination of egg and milk allergen in food products by liquid chromatography-tandem mass spectrometry based on signature peptides and isotope-labeled internal standard
10
作者 Sufang Fan Junmei Ma +4 位作者 Zhuo Liu Yawei Ning Meicong Cao Qiang Li Yan Zhang 《Food Science and Human Wellness》 SCIE CSCD 2023年第3期728-736,共9页
The aim of this work was to develop a liquid chromatography-tandem mass spectrometry method for the determination of milk allergen and egg allergen in food products.Signature peptides GGLEPINFQTAADQAR,VGINYWLAHK,VLVLD... The aim of this work was to develop a liquid chromatography-tandem mass spectrometry method for the determination of milk allergen and egg allergen in food products.Signature peptides GGLEPINFQTAADQAR,VGINYWLAHK,VLVLDTDYK,FFVAPFPEVFGK,and NAVPITPTLNR were confirmed and synthesized as the quantitative peptide of ovalbumin,α-lactalbumin,β-lactoglobulin,α_(S1)-casein andα_(S2)-casein,the relative isotope-labeled internal standards were used in the quantitative analysis.Linear range was in the range of0.5-5000.0 nmol/L for egg and milk allergen in bread,cake,cookie,rice crust and wheat flour samples with free from egg and milk,the limits of detection of milk allergens and egg allergen were in the range between0.94 mg/100 g and 56.71 mg/100 g,limits of quantification of milk allergens and egg allergen were in the range between 2.36 mg/100 g and 141.78 mg/100 g.The recoveries ranged from 76.7%to 122.8%,the relative standard deviations were in the range of 1.60%-15.60%.The developed method has been successfully used for the detection of egg and milk allergen in various food samples. 展开更多
关键词 Liquid chromatography-tandem mass spectrometry Egg and milk allergen Signature peptides Isotope-labeled internal standards
下载PDF
Simultaneous Determination of 14 β-Receptor Agonists Residues in Mutton by High Performance Liquid Chromatography-Tandem Mass Spectrometry (HPLC-MS/MS)
11
作者 Zhe MENG Jianhua WANG +5 位作者 Bo LIU Yuhang GUO Haoshuang DONG Pingyang SHAN Dawei WANG Yajuan SONG 《Agricultural Biotechnology》 CAS 2023年第5期55-58,共4页
[Objectives]A high performance liquid chromatography-tandem mass spectrometry(HPLC-MS/MS)method was established for the determination of 14β-receptor agonist residues in mutton.[Methods]Samples were hydrolyzed byβ-g... [Objectives]A high performance liquid chromatography-tandem mass spectrometry(HPLC-MS/MS)method was established for the determination of 14β-receptor agonist residues in mutton.[Methods]Samples were hydrolyzed byβ-glucuronidase and extracted with 5%acetic acid-acetonitrile(1:99,V/V)solution.An Eclipse plus C 18 column was used for separation,and the MRM mode was used for qualitative analysis,and the external standard method was used for quantitative analysis of matrix standard solutions.[Results]Under the optimal conditions,the retention time of the 14 kinds ofβ-receptor agonists ranged from 1.0 to 9.5 min.When the mass concentration was in the range of 0.05-0.50μg/ml,the linear relationship ofβ-receptor agonists was good,with correlation coefficients(r)≥0.9992.The detection limits of the method were in the range of 0.04-0.87μg/kg,and the quantitative limits were in the range of 0.35-1.86μg/kg.The average recovery values were in the range of 82.8%-108.9%,with RSDs(n=6)in the range of 1.9%-6.7%.[Conclusions]The method is simple,sensitive,reproducible,accurate,and can be used for simultaneous determination of the 14 kinds ofβ-receptor agonist residues in mutton. 展开更多
关键词 MUTTON High performance liquid chromatography-tandem mass spectrometry β-receptor agonist RESIDUE
下载PDF
Determination of Voriconazole in Human Plasma by Liquid Chromatography Tandem Mass Spectrometry: Application in Therapeutic Drug Monitoring
12
作者 Waleed Alhussaini Ezzeldeen Ghanem +4 位作者 Magd Alsahly Amani Kurdi Eman Alharbi Imadul Islam Majed Aljeraisy 《American Journal of Analytical Chemistry》 2023年第9期378-389,共12页
A sensitive, accurate and robust Liquid Chromatography Tandem Mass Spectrometry method has been developed and validated to measure voriconazole trough levels in human plasma. The plasma samples were mixed with flucona... A sensitive, accurate and robust Liquid Chromatography Tandem Mass Spectrometry method has been developed and validated to measure voriconazole trough levels in human plasma. The plasma samples were mixed with fluconazole as an Internal Standard and directed to protein precipitation and drug extraction. An aliquot of 1 μl was injected into the chromatographic system and separated by the Acquity BEH C18 column at a flow rate of 0.30 ml/min in a gradient mobile phase consisting of acetonitrile, Ultrapure water (UPW), methanol and formic acid. Voriconazole was detected by a Triple Quadrupole Detector (TQD) operating on Multiple Reaction Monitoring (MRM) and a positive ion mode Electrospray ionization (ESI) Q1 mass: 350.1 m/z, Q3 mass: 281.1 m/z. Method linearity of the calibration curve (0.10 - 8.00 μg/ml) indicated a correlation coefficient r ≥ 0.99. The intra and inter-assay accuracy was within 85% - 115% and the intra and inter-assay precision was ≤5.76%. Voriconazole recovery percentage was between 97.69 - 119.62%. The method was successively applied in routine voriconazole TDM. 展开更多
关键词 VORICONAZOLE Human Plasma Liquid Chromatography Tandem mass spectrometry Therapeutic Drug Monitoring
下载PDF
Determination of Oleuropein in Cosmetics by Ultra Performance Liquid Chromatography-Triple Quadrupole Tandem Mass Spectrometry
13
作者 Pan Lijing Chen Weiwei Yuan Minjia 《China Detergent & Cosmetics》 CAS 2023年第4期30-36,共7页
An ultrahigh performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS)was established to quickly and accurately determine the content of oleuropein in cosmetics.The samples were extracte... An ultrahigh performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS)was established to quickly and accurately determine the content of oleuropein in cosmetics.The samples were extracted with methanol-aqueous solution,and the mobile phase with methanol-formic acid solution(0.1 mol/L)=40∶60 was separated by Agilent ZORBAX Eclipse Plus C18(2.1 mm×50 mm×1.8μm-Micron)column temperature 30℃,flow rate 0.3 mL/min.The MS end was detected by electrospray negative mode ionization(ESI-)and multiple reaction monitoring(MRM)mode.The results show a good linear relationship in the range of 0.002~5 mg/L,with a correlation coefficient R2 of 0.999,5.Method recovery range from 84.2%~107.6%and the relative standard deviation RSD is 5.8%.The detection time is 5 min,the detection limit is 0.000,6 mg/L,and the limit of quantification is 0.002 mg/L.This method has the advantages of convenient operation,low quantification limit,high precision and good repeatability,and is suitable for measuring the content of oleuropein in many kinds of cosmetics. 展开更多
关键词 ultra performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS) OLEUROPEIN COSMETICS
下载PDF
Analyzing Brazilian Driver’s License Authenticity by Easy Ambient Sonic-Spray Ionization Mass Spectrometry
14
作者 Deleon Nascimento Correa Eduardo Morgado Schmidt +6 位作者 Marcos Fernando Franco Jorge Jardim Zacca Werickson Fortunato de Carvalho Rocha Antony de Paula Barbosa Rodrigo Borges Wanderley de Souza Marcos Nogueira Eberlin 《American Journal of Analytical Chemistry》 2016年第4期342-350,共9页
Fast and unequivocal methods of questioned document analysis are essential in forensic science. Here, a desorption/ionization technique, EASI-MS, was assessed for its ability to investigate questioned driver’s licens... Fast and unequivocal methods of questioned document analysis are essential in forensic science. Here, a desorption/ionization technique, EASI-MS, was assessed for its ability to investigate questioned driver’s licenses (DL). Two suspects DL, displaying the same personal data in the proper fields (name and ID numbers), but with different individual photos, showing similar impressions on microscopic analysis, and authentic standards documents specimens were used as test cases. Profiles from authentic DL surface were dominated by a set of few minor ions, mainly from the plasticizers bis(2-ethylhexyl)phthalate and dibutylphthalate. The seized suspect counterfeit DL on points from personal data and photo were, however, dominated by abundant diagnostic ions of m/z 463, 507, 551, 595, 639, 683, which confirmed counterfeiting. Surfynol<sup>&reg;</sup> and Nonoxynol-9<sup>&reg;</sup>, which are common constituents of inkjet printing, were detected in the counterfeiting areas by high-accuracy EASI(+)-FT-ICR MS. The EASI-MS technique is shown therefore to offer an attractive tool for forensic investigation of questioned documents. 展开更多
关键词 Forensic Sciences Questioned Documents Ambient mass spectrometry Easy Ambient Sonic-Spray Ionization mass spectrometry EASI-MS
下载PDF
Offline two-dimensional liquid chromatography coupled with ion mobility-quadrupole time-of-flight mass spectrometry enabling fourdimensional separation and characterization of the multicomponents from white ginseng and red ginseng 被引量:9
15
作者 Tiantian Zuo Chunxia Zhang +7 位作者 Weiwei Li Hongda Wang Ying Hu Wenzhi Yang Li Jia Xiaoyan Wang Xiumei Gao Dean Guo 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2020年第6期597-609,共13页
Inherent complexity of plant metabolites necessitates the use of multi-dimensional information to accomplish comprehensive profiling and confirmative identification.A dimension-enhanced strategy,by offline two-dimensi... Inherent complexity of plant metabolites necessitates the use of multi-dimensional information to accomplish comprehensive profiling and confirmative identification.A dimension-enhanced strategy,by offline two-dimensional liquid chromatography/ion mobility-quadrupole time-of-flight mass spectrometry(2 D-LC/IM-QTOF-MS)enabling four-dimensional separations(2 D-LC,IM,and MS),is proposed.In combination with in-house database-driven automated peak annotation,this strategy was utilized to characterize ginsenosides simultaneously from white ginseng(WG)and red ginseng(RG).An offline 2 DLC system configuring an Xbridge Amide column and an HSS T3 column showed orthogonality 0.76 in the resolution of ginsenosides.Ginsenoside analysis was performed by data-independent high-definition MSE(HDMSE)in the negative ESI mode on a Vion?IMS-QTOF hybrid high-resolution mass spectrometer,which could better resolve ginsenosides than MSEand directly give the CCS information.An in-house ginsenoside database recording 504 known ginsenosides and 58 reference compounds,was established to assist the identification of ginsenosides.Streamlined workflows,by applying UNIFI?to automatedly annotate the HDMSEdata,were proposed.We could separate and characterize 323 ginsenosides(including 286 from WG and 306 from RG),and 125 thereof may have not been isolated from the Panax genus.The established 2 D-LC/IM-QTOF-HDMSEapproach could also act as a magnifier to probe differentiated components between WG and RG.Compared with conventional approaches,this dimensionenhanced strategy could better resolve coeluting herbal components and more efficiently,more reliably identify the multicomponents,which,we believe,offers more possibilities for the systematic exposure and confirmative identification of plant metabolites. 展开更多
关键词 Dimension-enhanced strategy Multicomponent characterization GINSENOSIDE Offline two-dimensional liquid chromatography Ion mobility-quadrupole time-of-flight mass spectrometry In-house database
下载PDF
Screening ofα-glucosidase inhibitors in large-leaf yellow tea by offline bioassay coupled with liquid chromatography tandem mass spectrometry 被引量:3
16
作者 You Wu Zisheng Han +8 位作者 Mingchun Wen Chi-Tang Ho Zongde Jiang Yijun Wang Na Xu Zhongwen Xie Jinsong Zhang Liang Zhang Xiaochun Wan 《Food Science and Human Wellness》 SCIE 2022年第3期627-634,共8页
Larger-leaf yellow tea(LYT)is a characteristic type of Chinese tea produced in Huoshan County,Anhui Province,which is made by mature leaves with stems.According to recent report,LYT showed competitive effects in anti-... Larger-leaf yellow tea(LYT)is a characteristic type of Chinese tea produced in Huoshan County,Anhui Province,which is made by mature leaves with stems.According to recent report,LYT showed competitive effects in anti-hyperglycemia in comparison to other teas such as green or black tea.However,the bioactive compounds of LYT are still undiscovered so far.For this purpose,5 fractions of LYT were prepared by sequential extraction.The in vitro bioassay results indicated that the ethyl acetate fraction of LYT had the strongest inhibitory effects onα-glucosidase andα-amylase.Fluorescence-quenching analysis and proteinbinding test revealed that the compounds of ethyl acetate fraction could inhibitα-glucosidase andα-amylase activities through binding to enzymes or other mechanisms.All chromatographic peaks of high-performance liquid chromatography(HPLC)of ethyl acetate fraction were separated and collected.The purified compounds were identified by liquid chromatography-mass spectrometry(LC-MS),and subsequently screened by calculating their inhibition ratio onα-glucosidase at the real concentration in LYT infusion.The results showed that(-)-epigallocatechin gallate,(-)-gallocatechin gallate,caffeine,N-ethyl-2-pyrrolidone-substituted flavan-3-ols were effective inhibitors forα-glucosidase. 展开更多
关键词 Larger-leaf yellow tea ANTI-HYPERGLYCEMIA Α-GLUCOSIDASE mass spectrometry Separation
下载PDF
Analysis of proteomic differences between liquefied aftercataracts and normal lenses using two-dimensional gel electrophoresis and mass spectrometry 被引量:2
17
作者 Jia-Jia Ge Yu-Sen Huang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第9期1344-1348,共5页
AIM: To analyze and identify the proteomic differences between liquefied after-cataracts and normal lenses by means of liquefied chromatography-tandem mass spectrometry(LC-MS/MS).METHODS: Three normal lenses and three... AIM: To analyze and identify the proteomic differences between liquefied after-cataracts and normal lenses by means of liquefied chromatography-tandem mass spectrometry(LC-MS/MS).METHODS: Three normal lenses and three liquefied after-cataracts were exposed to depolymerizing reagents to extract the total proteins. Protein concentrations were separated using two-dimensional gel electrophoresis(2-DE). The digitized images obtained with a GS-800 scanner were then analyzed with PDQuest7.0 software to detect the differentially-expressed protein spots. These protein spots were cut from the gel using a proteome work spot cutter and subjected to in-gel digestion with trypsin. The digested peptide separation was conducted by LC-MS/MS.RESULTS: The 2-DE maps showed that lens proteins were in a p H range of 3-10 with a relative molecular weight of 21-70 kD. The relative molecular weight of the more abundant proteins was localized at 25-50 kD, and the isoelectric points were found to lie between PI 4-9. The maps also showed that the protein level within the liquefied after-cataracts was at 29 points and significantly lower than in normal lenses. The 29 points were identified by LC-MS/MS, and ten of these proteins were identified by mass spectrometry and database queries: beta-crystallin B1, glyceraldehyde-3-phosphate dehydrogenase, carbonyl reductase(NADPH) 1, cDNA FLJ55253, gamma-crystallin D, GAS2-like protein 3, sorbitol dehydrogenase, DNA FLJ60282, phosphoglycerate kinase, and filensin. CONCLUSION: The level of the ten proteins may play an important role in the development of liquefied aftercataracts. 展开更多
关键词 capsular block syndrome liquefied after-cataract liquid chromatography-tandem mass spectrometry
原文传递
Identification of potential oxidative stress biomarkers for spinal cord injury in erythrocytes using mass spectrometry 被引量:1
18
作者 Li-Jian Zhang Yao Chen +2 位作者 Lu-Xuan Wang Xiao-Qing Zhuang He-Chun Xia 《Neural Regeneration Research》 SCIE CAS CSCD 2021年第7期1294-1301,共8页
Oxidative stress is a hallmark of secondary injury associated with spinal cord injury.Identifying stable and specific oxidative biomarkers is of important significance for studying spinal cord injury-associated second... Oxidative stress is a hallmark of secondary injury associated with spinal cord injury.Identifying stable and specific oxidative biomarkers is of important significance for studying spinal cord injury-associated secondary injury.Mature erythrocytes do not contain nuclei and mitochondria and cannot be transcribed and translated.Therefore, mature erythrocytes are highly sensitive to oxidative stress and may become a valuable biomarker.In the present study, we revealed the proteome dynamics of protein expression in erythrocytes of beagle dogs in the acute and subacute phases of spinal cord injury using mass spectrometry-based approaches.We found 26 proteins that were differentially expressed in the acute(0–3 days) and subacute(7–21 days) phases of spinal cord injury.Bioinformatics analysis revealed that these differentially expressed proteins were involved in glutathione metabolism, lipid metabolism, and pentose phosphate and other oxidative stress pathways.Western blot assays validated the differential expression of glutathione synthetase, transaldolase, and myeloperoxidase.This result was consistent with mass spectrometry results, suggesting that erythrocytes can be used as a novel sample source of biological markers of oxidative stress in spinal cord injury.Glutathione synthetase, transaldolase, and myeloperoxidase sourced from erythrocytes are potential biomarkers of oxidative stress after spinal cord injury.This study was approved by the Experimental Animal Centre of Ningxia Medical University, China(approval No.2017-073) on February 13, 2017. 展开更多
关键词 acute phase bioinformatic analysis biomarkers central nervous system DOG erythrocytes mass spectrometry oxidative stress peripheral blood spinal cord injury subacute phase
下载PDF
Analysis of ethoxyquin and its oxidation products in swine tissues by gas chromatography-tandem mass spectrometry for evaluating the feed-toanimal tissue transfer of ethoxyquin and its metabolites 被引量:1
19
作者 Chi Zhang Xiangrong Gai +5 位作者 Ying Tian Jiayi Wang Dongting He Wenjun Yang Liying Zhang Yiqiang Chen 《Journal of Animal Science and Biotechnology》 SCIE CAS CSCD 2021年第2期806-814,共9页
Background:Ethoxyquin(EQ)is a common antioxidant which is widely used in animal feed.But the supplement of EQ in animal feed may lead to the residues of EQ and its major oxidation products:ethoxyquin quinone imine(EQI... Background:Ethoxyquin(EQ)is a common antioxidant which is widely used in animal feed.But the supplement of EQ in animal feed may lead to the residues of EQ and its major oxidation products:ethoxyquin quinone imine(EQI)and ethoxyquin dimer(EQDM)in animal tissue.Thus,it would pose potential health hazards to consumers.However,the method for the simultaneous determination of EQ,EQI and EQDM in animal tissues is currently not available,and the accumulation extend of these chemicals in animal tissues after EQ administration remains to be evaluated.Results:A gas chromatography-tandem mass spectrometry method was successfully developed for the simultaneous determination of EQ,EQI and EQDM in swine tissues.The quantitative limits of EQ,EQI and EQDM can achieve to 0.5,5.0 and 5.0μg/kg in swine tissues,respectively.The spiked-recovery ratios of the three analytes(5–2000μg/kg)were in the range of 64.7%–100.7%with relative standard deviations below 11.6%.Moreover,the utilization of this method for the analysis of actual swine tissue samples revealed that the application of commercial EQ additive in swine diet would produce the residues of all the three chemicals(EQ,EQI and EQDM)in fat,kidney,liver and muscle.Conclusions:The assay accuracy and precision of this GC-MS/MS method can meet the requirement of quantitative analysis.Meanwhile,the safety of EQ as a feed additive should be seriously considered with regard to food safety concerns since the oxidation product of EQ may have potential carcinogenicity. 展开更多
关键词 Ethoxyquin Ethoxyquin dimer Ethoxyquin quinone imine Gas chromatography-tandem mass spectrometry Safety evaluation Swine tissues
下载PDF
Charge resolution in the isochronous mass spectrometry and the mass of ^(51)Co 被引量:1
20
作者 Xu Zhou Meng Wang +25 位作者 Yu-Hu Zhang Hu-Shan Xu You-Jin Yuan Jian-Cheng Yang Yu.A.Litvinov S.A.Litvinov Bo Mei Xin-Liang Yan Xing Xu Peng Shuai Yuan-Ming Xing Rui-Jiu Chen Xiang-Cheng Chen Chao-Yi Fu Qi Zeng Ming-Ze Sun Hong-Fu Li Qian Wang Tong Bao Min Zhang Min Si Han-Yu Deng Ming-Zheng Liu Ting Liao Jin-Yang Shi Yu-Nan Song 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2021年第4期30-37,共8页
Isochronous mass spectrometry(IMS)of heavyion storage rings is a powerful tool for the mass measurements of short-lived nuclei.In IMS experiments,masses are determined through precision measurements of the revolution ... Isochronous mass spectrometry(IMS)of heavyion storage rings is a powerful tool for the mass measurements of short-lived nuclei.In IMS experiments,masses are determined through precision measurements of the revolution times of the ions stored in the ring.However,the revolution times cannot be resolved for particles with nearly the same mass-to-charge(m/q)ratios.To overcome this limitation and to extract the accurate revolution times for such pairs of ion species with very close m/q ratios,in our early work on particle identification,we analyzed the amplitudes of the timing signals from the detector based on the emission of secondary electrons.Here,the previous data analysis method is further improved by considering the signal amplitudes,detection efficiencies,and number of stored ions in the ring.A sensitive Z-dependent parameter is introduced in the data analysis,leading to a better resolution of ^(34)Ar^(18+) and ^(51)Co^(27+) with A/Z=17/9.The mean revolution times of ^(34)Ar^(18+) and ^(51)Co^(27+) are deduced,although their time difference is merely 1.8 ps.The uncorrected,overlapped peak of these ions has a full width at half maximum of 7.7 ps.The mass excess of ^(51)Co was determined to be-27;332e41T keV,which is in agreement with the previous value of-27;342e48T keV. 展开更多
关键词 Isochronous mass spectrometry Charge resolution Signal amplitude Micro-channel plate ^(51)Co
下载PDF
上一页 1 2 24 下一页 到第
使用帮助 返回顶部