期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Outcomes of Chimney and/or Periscope Techniques in the Endovascular Management of Complex Aortic Pathologies 被引量:4
1
作者 Zhi-Yuan Wu Zuo-Guan Chen +6 位作者 Li Ma Yong-Peng Diao Yue-Xin Chen Chang-Wei Liu Yue-Hong Zheng Bao Liu Yong-Jun Li 《Chinese Medical Journal》 SCIE CAS CSCD 2017年第17期2095-2100,共6页
Background:The chimney/periscope technique has been used to address complex aortic pathologies.This study aimed to report the outcomes and experiences of chimney and/or periscope grafts (CPGs) used in the endovascu... Background:The chimney/periscope technique has been used to address complex aortic pathologies.This study aimed to report the outcomes and experiences of chimney and/or periscope grafts (CPGs) used in the endovascular management of complex aortic pathologies.Methods:Twenty-two patients with complex aortic pathologies were retrospectively studied from January 2013 to August 2016 in two vascular centers of teaching hospitals.All patients were diagnosed using computed tomography angiography (CTA).The patients were followed up at postoperative 1,3,6,and 12 months and yearly thereafter with X-ray,ultrasound,and/or CTA.Results:Twenty-two cases (17 males;mean age 60.7 &#177; 16.3 years) with complex aortic pathologies were analyzed.Nineteen patients underwent CPGs only,and the other three cases underwent the simultaneous implantation of chimney/periscope and fenestrated/scallop grafts.Twenty-six arteries were managed with forty CPGs during the procedures.Complete angiographies revealed two Type Ⅰ endoleaks,one Type Ⅲ endoleak,and one Type Ⅳ endoleak.Other intraoperative complications included brachial thrombosis,external iliac artery rupture,and left renal stenosis.The 30-day mortality was 0.The mean follow-up was 26.1 &#177; 10.1 months with a range of 2-39 months.During the follow-up,two Type Ⅰ endoleaks and one Type Ⅳ endoleak were observed.One right renal stent occlusion occurred in the 5th month and turned patent after reintervention.Three patients died during the follow-up,one due to an aneurysm rupture as a Type Ⅰ endoleak,and two due to myocardial infarction.The instant technical success was 96%.The primary and secondary patencies were 92%and 96%,respectively.The overall survival rates were 95%,84%,and 84% at 12,24,and 36 months,respectively.Stent migration was not observed in any patient.Conclusions:Chimney/periscope techniques could be used to tackle complex aortic pathologies,but the indications must be strictly controlled,and additional experiences are required. 展开更多
关键词 Anetlrysm Chimney/periscope technique Complex Aortic Pathologies DISSECTION Endovascular Aortic Repair
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部