期刊文献+
共找到596篇文章
< 1 2 30 >
每页显示 20 50 100
Relationship of Retinal Nerve Fiber Layer Thickness and Retinal Vessel Calibers with Cognitive Impairment in the Asymptomatic Polyvascular Abnormalities Population
1
作者 WANG Dan Dan WANG An Xin +3 位作者 ZHANG Xiao Li WEI Wen Bin WU Shou Ling ZHAO Xing Quan 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2024年第2期196-203,共8页
Objective Cognitive impairment(CI)in older individuals has a high morbidity rate worldwide,with poor diagnostic methods and susceptible population identification.This study aimed to investigate the relationship betwee... Objective Cognitive impairment(CI)in older individuals has a high morbidity rate worldwide,with poor diagnostic methods and susceptible population identification.This study aimed to investigate the relationship between different retinal metrics and CI in a particular population,emphasizing polyvascular status.Methods We collected information from the Asymptomatic Polyvascular Abnormalities Community Study on retinal vessel calibers,retinal nerve fiber layer(RNFL)thickness,and cognitive function of 3,785participants,aged 40 years or older.Logistic regression was used to analyze the relationship between retinal metrics and cognitive function.Subgroups stratified by different vascular statuses were also analyzed.Results RNFL thickness was significantly thinner in the CI group(odds ratio:0.973,95%confidence interval:0.953–0.994).In the subgroup analysis,the difference still existed in the non-intracranial arterial stenosis,non-extracranial carotid arterial stenosis,and peripheral arterial disease subgroups(P<0.05).Conclusion A thin RNFL is associated with CI,especially in people with non-large vessel stenosis.The underlying small vessel change in RNFL and CI should be investigated in the future. 展开更多
关键词 retinal nerve fiber layer Cognitive impairment Polyvascular abnormality
下载PDF
Retinal nerve fiber layer defects and chronic kidney disease:the Kailuan Eye Study
2
作者 Qian-Qian Wan Jin-Qiong Zhou +9 位作者 Li-Jian Fang Ya-Xing Wang Ye-Nan Wang Qian Wang Yan-Ni Yan Xuan Yang Shou-Ling Wu Shuo-Hua Chen Jost B Jonas Wen-Bin Wei 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第9期1696-1706,共11页
AIM:To investigate whether retinal nerve fiber layer defects(RNFLDs)is a potential risk factor for chronic kidney disease(CKD)in Chinese adults.METHODS:The Kailuan Eye Study was a populationbased study that included 1... AIM:To investigate whether retinal nerve fiber layer defects(RNFLDs)is a potential risk factor for chronic kidney disease(CKD)in Chinese adults.METHODS:The Kailuan Eye Study was a populationbased study that included 14440 participants.All participants underwent detailed assessments,RNFLDs were diagnosed using color fundus photographs.RESULTS:Overall,12507 participants[8533 males(68.23%)]had complete systemic examination data and at least one evaluable fundus photograph.RNFLDs were found in 621 participants[5.0%;95%confidence interval(CI):4.6%-5.34%],and 70 cases of multiple RNFLDs were found(11.27%).After adjusting multiple factors,RNFLDs was significantly associated with CKD severity,the ORs of CKD stage 3,stage 4 and stage 5 were 1.698,4.167,and 9.512,respectively.Multiple RNFLDs were also associated with CKD severity after adjusting multiple factors,the ORs of CKD stage 3 and stage 5 were 4.465 and 11.833 respectively.Furthermore,2294 participants had CKD(18.34%,95%CI:17.68%-18.99%).After adjusting for other factors,CKD presence was significantly correlated with the presence of RNFLDs.CONCLUSION:The strongest risk factors for RNFLDs are CKD and hypertension.Conversely,RNFLDs can be an ocular feature in patients with CKD.Fundoscopy can help detect systemic diseases,and assessment for RNFLDs should be considered in CKD patients. 展开更多
关键词 chronic kidney disease retinal nerve fiber layer defects Kailuan Eye Study fundus examination
原文传递
Quantifying peripapillary vessel density and retinal nerve fibre layer in type 1 diabetic children without clinically detectable retinopathy using OCTA
3
作者 Ling Chen Yun Feng +2 位作者 Sha-Sha Zhang Yan-Fang Liu Ping Lin 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期278-281,共4页
AIM:To quantify changes in radial peripapillary capillary vessel density(ppVD)and the peripapillary retinal nerve fiber layer(pRNFL)in children with type 1 diabetes without clinical diabetic retinopathy by optical coh... AIM:To quantify changes in radial peripapillary capillary vessel density(ppVD)and the peripapillary retinal nerve fiber layer(pRNFL)in children with type 1 diabetes without clinical diabetic retinopathy by optical coherence tomography angiography(OCTA),providing a basis for early retinopathy in children with type 1 diabetes.METHODS:This was a retrospective study.A total of 30 patients(3–14y)with type 1 diabetes without clinical diabetic retinopathy(NDR group)were included.A total of 30 age-matched healthy subjects were included as the normal control group(CON group).The HbA1c level in the last 3mo was measured once in the NDR group.The pRNFL thickness and ppVD were automatically measured,and the mean pRNFL and ppVD were calculated in the nasal,inferior,temporal,and superior quadrants.The changes in ppVD and pRNFL in the two groups were analyzed.RESULTS:Compared with CON group,the nasal and superior ppVDs decreased in the NDR group(all P<0.01).The thickness of the nasal pRNFL decreased significantly(P<0.01),while the inferior,temporal and superior pRNFLs slightly decreased but not significant in the NDR group(all P>0.05).Person and Spearman correlation analysis of ppVD and pRNFL thickness in each quadrant of the NDR group showed a positive correlation between nasal and superior(all P<0.01),while inferior and temporal had no significant correlation(all P>0.05).There was no significant correlation between the HbA1c level and ppVD and pRNFL in any quadrant(all P>0.05).There was no significant correlation between the course of diabetes mellitus and ppVD and pRNFL in any quadrant(all P>0.05).CONCLUSION:ppVD and pRNFL decrease in eyes of children with type 1 diabetes before clinically detectable retinopathy and OCTA is helpful for early monitoring. 展开更多
关键词 diabetic retinopathy CHILDREN peripapillary vessel density peripapillary retinal nerve fiber layer optical coherence tomography angiography
原文传递
Analysis of risk and protective factors associated with retinal nerve fiber layer defect in a Chinese adult population 被引量:1
4
作者 Ye-Nan Wang Ya-Xing Wang +14 位作者 Jin-Qiong Zhou Qian-Qian Wan Li-Jian Fang Hai-Wei Wang Jing-Yan Yang Li Dong Jin-Yuan Wang Xuan Yang Yan-Ni Yan Qian Wang Shou-Ling Wu Shuo-Hua Chen Jing-Yuan Zhu Wen-Bin Wei Jost B.Jonas 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第3期427-433,共7页
AIM:To investigate the risk and protective factors associated with the retinal nerve fiber layer defect(RNFLD)in a Chinese adult population.METHODS:This study was a cross-sectional populationbased investigation includ... AIM:To investigate the risk and protective factors associated with the retinal nerve fiber layer defect(RNFLD)in a Chinese adult population.METHODS:This study was a cross-sectional populationbased investigation including employees and retirees of a coal mining company in Kailuan City,Hebei Province.All the study participants underwent a comprehensive systemic and ophthalmic examination.RNFLD was diagnosed on fundus photographs.Binary logistic regression was used to investigate the risk and protective factors associated with the RNFLD.RESULTS:The community-based study included 14440 participants.There were 10473 participants in our study,including 7120 males(68.0%)and 3353 females(32.0%).The age range was 45-108y,averaging 59.56±8.66y.Totally 568 participants had RNFLD and the prevalence rate was 5.42%.A higher prevalence of RNFLD was associated with older age[P<0.001,odds ratio(OR):1.032;95%confidence interval(CI):1.018-1.046],longer axial length(P=0.010,OR:1.190;95%CI:1.042-1.359),hypertension(P=0.007,OR:0.639;95%CI:0.460-0.887),and diabetes mellitus(P=0.019,OR:0.684;95%CI:0.499-0.939).The protective factors of RNFLD were visual acuity(P=0.038,OR:0.617;95%CI:0.391-0.975),and central anterior chamber depth(P=0.046,OR:0.595;95%CI:0.358-0.990).CONCLUSION:In our cross-sectional community-based study,with an age range of 45-108y,RNFLD is associated with older age,longer axial length,hypertension,and diabetes mellitus.The protective factors of RNFLD are visual acuity and central anterior chamber depth.These can help to predict and evaluate RNFLD related diseases and identify high-risk populations early. 展开更多
关键词 retinal nerve fiber layer defect retinal nerve fiber layer age axial length HYPERTENSION diabetes mellitus visual acuity central anterior chamber depth
原文传递
Bilateral retinal nerve fiber layer thickness reduction in a 9-year-old myopic boy suffering from unilateral optic neuritis:A case report
5
作者 Fang-Fang Zhao Shi-Qi Yao +4 位作者 Yun Wang Tai-Ping Li Jian-Feng Yang Chi-Pui Pang Ling-Ping Cen 《World Journal of Clinical Cases》 SCIE 2023年第28期6806-6811,共6页
BACKGROUND In this paper,we present a 9-year-old boy who demonstrates a complex interplay between myopia progression,axial length(AL)extension,and retinal nerve fiber layer(RNFL)thickness loss in both eyes.Additionall... BACKGROUND In this paper,we present a 9-year-old boy who demonstrates a complex interplay between myopia progression,axial length(AL)extension,and retinal nerve fiber layer(RNFL)thickness loss in both eyes.Additionally,concurrent optic neuritis has directly impacted RNFL thickness in his right eye,and its potential indirect influence on RNFL and macular ganglion cell layer(mGCL)thickness in his left eye is also noteworthy.CASE SUMMARY A 9-year-old boy with bilateral myopia presented with diminished vision and pain in his right eye due to optic neuritis,while his left eye showed pseudopapilledema.Steroid therapy improved his vision in the right eye,and 16-mo follow-up revealed recovery without recurrence despite myopia progression.Follow-up optical coherence tomography conducted 16 mo later revealed a notable thinning of the RNFL in both eyes,especially along with a reduction in mGCL thickness in the left eye.This intricate interaction between optic neuritis,myopia,and retinal changes underscores the need for comprehensive management,highlighting potential long-term visual implications in young patients.CONCLUSION The progression of myopia and AL extension led to the loss of RNFL thickness in both eyes in a 9-year-old boy.Concurrently,optic neuritis directly affected RNFL thickness in his right eye and may indirectly play a role in the thickness of RNFL and mGCL in his left eye. 展开更多
关键词 retinal nerve fiber layer MYOPIA Optic neuritis Macular ganglion cell Case report
下载PDF
Evaluation of peripapillary retinal nerve fiber layer, macula and ganglion cell thickness in amblyopia using spectral optical coherence tomography 被引量:7
6
作者 Penpe Gul Firat Ercan Ozsoy +2 位作者 Soner Demire Tongabay Cumurcu Abuzer Gunduz 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2013年第1期90-94,共5页
AIM:To investigate peripapillary retinal nerve fiber layer (RNFL), macula and ganglion cell layer thicknesses (GCC) in amblyopic eyes with spectral domain optical coherence tomography (SD-OCT). METHODS:Thirty six pati... AIM:To investigate peripapillary retinal nerve fiber layer (RNFL), macula and ganglion cell layer thicknesses (GCC) in amblyopic eyes with spectral domain optical coherence tomography (SD-OCT). METHODS:Thirty six patients with a history of unilateral amblyopia and thirty two children who had emmetropia without amblyopia were included in this study. In this institutional study, 36 eyes of 36 patients with amblyopia (AE), 36 fellow eyes without amblyopia (FE), and 32 eyes of 32 normal subjects (NE) were included. RNFL, GCC and macular thickness measurements were performed with RS-3000 OCT Retina Scan (Nidek Inc CA. USA). RESULTS:The mean global thicknesses of the RNFL were 113.22 ±21.47, 111.57 ±18.25, 109.96 ±11.31μm in the AE, FE, and NE, respectively. There was no statistically significant difference for mean global RNFL thickness among the eyes (P =0.13). The mean thicknesses of the macula were 258.25±18.31, 258.75±19.54, 248.62±10.57μm in the AE, FE and NE, respectively. There was no statistically significant difference for thickness of macula among the eyes (P =0.06). The GCC was investigated into two parts:superior and inferior. The mean thicknesses of superior GCC were 102.57 ±13.32, 103.32 ±10.64, 100.52 ± 5.88μm in the AE, FE, and NE, respectively. The mean thicknesses of inferior GCC were 103.82 ±12.60, 107.82 ± 12.33, 105.86±10.79μm in the AE, FE and NE, respectively. There was no statistically significant difference for thickness of superior and inferior GCC between the eyes (P =0.63, P =0.46). ·CONCLUSION:The macular thicknesses of AE and FE were greater than the NE, although it was not statistically significant. Amblyopia does not seem to have a profound effect on the RNFL, macula and GCC. 展开更多
关键词 AMBLYOPIA retinal nerve fiber layer MACULA ganglion cell complex
原文传递
Effect of suction on macular thickness and retinal nerve fiber layer thickness during LASIK used femtosecond laser and Moria M2 microkeratome 被引量:7
7
作者 Jing Zhang Yue-Hua Zhou 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2015年第4期777-783,共7页
·AIM: To compare the effect of suction on the macular thickness and retinal nerve fiber layer(RNFL) thickness during laser in situ keratomileusis(LASIK) used Ziemer FEMTO LDV femtosecond laser(Ziemer group) and M... ·AIM: To compare the effect of suction on the macular thickness and retinal nerve fiber layer(RNFL) thickness during laser in situ keratomileusis(LASIK) used Ziemer FEMTO LDV femtosecond laser(Ziemer group) and Moria M2 automated microkeratome(Moria group) for flap creation.· METHODS: Fourier-domain optical coherence tomography(FD-OCT) was used to measure macular thickness, ganglion cell complex thickness and RNFL thickness of 204 eyes of 102 patients with the Ziemer femtosecond laser(102 eyes) and the Moria M2microkeratome(102 eyes) before surgery and 30min; 1,3d; 1wk; 1, 3mo; 1y after surgery.· RESULTS: The average foveal thickness and parafoveal retinal thickness 30 min after the surgery were statistically more than that before surgery(Ziemer P 【0.001,P =0.003 and Moria P=0.001, P=0.006) and the effect was less in the Ziemer group than that in the Moria group(P all 【0.05). The ganglion cell complex thickness was not significantly changed in both groups(P all 】0.05). The RNFL thickness was statistically less 30 min after surgery in both groups(P=0.014, P 【0.001), but the influence was less in Ziemer group than that in Moria group(P =0.038).However, the RNFL thickness had recovered to the preoperative level only 1d after surgery.·CONCLUSION: The suction of femtosecond laser and mechanical microkeratome led to the increase in macular central fovea thickness and the decrease in RNFL thickness values at the early stage after LASIK. The effect of suction on macular and the RNFL thicknesses in Ziemer group is smaller than that in Moria group. 展开更多
关键词 laser in situ keratomileusis femtosecond laser MACULAR retinal nerve fiber layer optical coherence tomography
原文传递
Retinal nerve fiber layer thickness changes in obstructive sleep apnea syndrome: one year follow-up results 被引量:9
8
作者 Mehmet Ozgur Zengin Ibrahim Tuncer Eyyup Karahan 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2014年第4期704-708,共5页
·AIM: To investigate the retinal nerve fiber layer(RNFL)thickness changes in patients with obstructive sleep apnea syndrome(OSAS) for one year follow-up. To discuss the possibility of detecting tendency of glauco... ·AIM: To investigate the retinal nerve fiber layer(RNFL)thickness changes in patients with obstructive sleep apnea syndrome(OSAS) for one year follow-up. To discuss the possibility of detecting tendency of glaucoma in this population by using spectral domain optical coherence tomography(3D-OCT-2000 Spectral domain).·METHODS: After polysomnographic study, all subjects(64 OSAS patients and 40 controls) underwent detailed ophthalmological examination. After these examinations,patients with glaucoma and patients who had ophthalmological and/or systemic disease were excluded from the study.Totally, 20 patients in OSAS group and five patients in controls were excluded from the study in the first examination and follow-up period. The RNFL thickness was assessed with OCT. Forty-four OSAS patients and 35 control subjects were followed up for12 mo. RNFL thickness change and OSAS patients were evaluated for severity of disease by Apnea-Hypopnea Index(AHI).·RESULTS: Forty-four OSAS patients and 35 controls were enrolled in the study. Statistically significance was found between OSAS patients and controls at the 12 thmo.Average RNFL thickness was found to be significantly lower in last measurements in OSAS patients when compared with first measurements and control subjects(P 【0.001, 0.002, respectively). There was a statistically significant correlation among AHI, and RNFL thickness(P 【0.05).·CONCLUSION: The results suggest that the patients with OSAS were related with a proportional decrease in the RNFL thickness. These patients should be followed up regularly for glaucomatous changes. Detecting more RNFL thinning in severe OSAS was important. 展开更多
关键词 obstructive sleep apnea syndrome optical coherence tomography retinal nerve fiber layer thickness
原文传递
Analysis of peripapillary retinal nerve fiber layer and inner macular layers by spectral-domain optical coherence tomography for detection of early glaucoma 被引量:6
9
作者 Pei-Wen Lin Hsueh-Wen Chang +1 位作者 Jih-Pin Lin Ing-Chou Lai 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第7期1163-1172,共10页
AIM: To analyze the diagnostic capabilities of peripapillary retinal nerve fiber layer(p RNFL) thickness and segmented inner macular layer(IML) thickness measured by spectraldomain optical coherence tomography fo... AIM: To analyze the diagnostic capabilities of peripapillary retinal nerve fiber layer(p RNFL) thickness and segmented inner macular layer(IML) thickness measured by spectraldomain optical coherence tomography for detection of early glaucoma. METHODS: Fifty-three patients with primary open angle glaucoma(POAG), 60 patients with normal tension glaucoma(NTG) and 32 normal control subjects were enrolled. Thicknesses of p RNFL, total macular layers(TML), and the IML, including macular RNFL(m RNFL) and macular ganglion cell layer(m GCL) were assessed. The areas under the receiver operating characteristic curves(AROC) were calculated to compare the diagnostic power of different parameters. RESULTS: There were no differences in the parameters of p RNFL, TML, and IML between POAG and NTG groups. The thicknesses of superior and inferior m GCL showed significant correlation with mean deviation of visual field(R2=0.071, P=0.004; R2=0.08, P=0.002). The m GCL thickness significantly correlated with the p RNFL thickness in the superior and inferior quadrants(R2=0.156, P〈0.001; R2=0.407, P〈0.001). The thickness of the inferior-outer sector of macula had greater AROCs than those in the inferior-inner sector of macula. The AROCs for superior(0.894) and inferior(0.879) p RNFL thicknesses were similar with the AROCs for superior(0.839) and inferior m GCL(0.864) thicknesses. Sensitivities at 80% specificity for global p RNFL, inferior-outer m GCL and inferior-outer m RNFL thicknesses were 0.938, 0.867, and 0.725, respectively. CONCLUSION: The diagnostic capability of the m GCL thickness is comparable to that of the p RNFL thickness in patients with early glaucoma. The inferior-outer sector of IML has a better diagnostic capability than the inferiorinner sector of IML for detection of early glaucoma. 展开更多
关键词 retinal nerve fiber layer ganglion cell layer primary open angle glaucoma normal tension glaucoma optical coherence tomography
原文传递
Diurnal changes in retinal nerve fiber layer thickness with obstructive sleep apnea/hypopnea syndrome 被引量:7
10
作者 Niphon Chirapapaisan Techawit Likitgorn +4 位作者 Mintra Pleumchitchom Darin Sakiyalak Wish Banhiran Manatsawin Saiman Wanicha Chuenkongkaew 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第7期979-983,共5页
AIM: To compare the retinal nerve fiber layer (RNFL) thickness in the morning and evening in Thai patients with varying degrees of obstructive sleep apnea/ hypopnea syndrome (OSAHS). METHODS: In this cross-sect... AIM: To compare the retinal nerve fiber layer (RNFL) thickness in the morning and evening in Thai patients with varying degrees of obstructive sleep apnea/ hypopnea syndrome (OSAHS). METHODS: In this cross-sectional study, potential OSAHS patients at Siriraj Hospital underwent polysomnography to determine the severity of OSAHS and an eye examination (including best corrected visual acuity, slit-lamp examination, and Goldmann applanation tonometry). RNFL thickness was recorded once in the morning and once in the evening, using spectral domain optical coherence tomography. Thickness was expressed as an average and given for each quadrant. Patients with ocular or systemic diseases that might affect RNFL thickness were excluded. RESULTS: Forty-one eyes of 41 patients were classified into 40SAHS groups. The average and mean RNFL thickness in most of the four quadrants of the severe OSAHS group trended toward being less than those in the comparable quadrants of the other groups in both the morning and evening. In the moderate OSAHS group, the average RNFL thickness and temporal and superior quadrant thickness in the morning were significantly higher than in the evening (P=0.01, P=0.01, and P=0.03, respectively). In the severe OSAHS group, the inferior quadrant thickness in the morning was significantly higher than in the evening (P =0.03). CONCLUSION: The RNFL thickness in the morning was higher than in the evening in moderate OSAHS. 展开更多
关键词 retinal nerve fiber layer thickness sleep apnea/hypopnea syndrome optical coherence tomography
原文传递
Topographic distribution features of the choroidal and retinal nerve fiber layer thickness in Chinese school-aged children 被引量:4
11
作者 Wei-Qin Liu Dan-Dan Wang +4 位作者 Xiao-Xia Yang Yan-Yan Pan Xue Song Yu-Shan Hou Chen-Xiao Wang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第9期1459-1466,共8页
AIM:To explore the topographic distribution features of choroidal thickness(CT)and retinal nerve fiber layer thickness(RNFLT),and determine the relationship between CT and ocular parameters in school-aged children.MET... AIM:To explore the topographic distribution features of choroidal thickness(CT)and retinal nerve fiber layer thickness(RNFLT),and determine the relationship between CT and ocular parameters in school-aged children.METHODS:The healthy school-aged children with low ametropia or emmetropia in Wenzhou were recruited for this cross-sectional study.With high-density optical coherence tomography(HD-OCT)combined with MATLAB software,the CT and RNFLT values in the macular area were measured at different locations and compared.Statistical analyses were performed to evaluate the correlation between CT and ophthalmic parameters,such as spherical equivalent(SE)and the axial length(AL).RESULTS:A total of 279 school-aged children with8.00±1.35 years of mean age(range,6-10 y)were included.The mean AL was 23.66±0.86 mm.The mean CT in CT-C(264.31±48.93μm)was thicker than that in CT-N1(249.54±50.52μm),and the average CT in the parafoveal region was also thicker than that in CT-N2(235.65±50.63μm).The subfoveal CT also varied substantially across refractive errors(P<0.001),and those with myopia(250.59±47.01μm)exhibited a thinner choroid compared with those with emmetropia(278.74±48.06μm).CT negatively correlated with AL(y=-21.72 x+779.17;R^2=0.1458),and positively correlated with SE(y=15.76 x+271.9;R^2=0.0727.OD;y=18.31 x+269.8;R^2=0.1007.OS).The average RNFLT was thickest in the peripapillary region(236.35±19.03μm),the mean RNFLT-S(131.10±15.16μm)was thicker than the RNFLT-I(128.20±16.59μm),and the mean RNFLT-T(76.54±11.99μm)was thicker than the RNFLT-N(64.28±8.55μm).The variations in the RNFLT between quadrants did differ between those with myopia and emmetropia(P<0.05).CONCLUSION:We establish demographic information for the choroid and RNFLT.These findings provide information that should be considered in future analyses of the CT and RNFLT in OCT studies in school-aged children. 展开更多
关键词 CHILDREN CHOROID MYOPIA refractive error retinal nerve fiber layer optical coherence tomography
原文传递
Peripapillary retinal nerve fiber layer thickness distribution in Chinese with myopia measured by 3D-optical coherence tomography 被引量:3
12
作者 Jing-Jing Zhao Wen-Juan Zhuang +2 位作者 Xue-Qiu Yang Shan-Shan Li Wei Xiang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2013年第5期626-631,共6页
AIMTo assess the effect of myopia on the thickness of retinal nerve fiber layer (RNFL) measured by 3D optical coherence tomography (3D-OCT) in a group of nonglaucomatous Chinese subjects.
关键词 optical coherence tomography MYOPIA retinal nerve fiber layer
原文传递
Retinal nerve fiber layer changes based on historic CD4 nadir among HIV positive patients undergoing glaucoma evaluation 被引量:2
13
作者 Sarah H.Van Tassel Paul Petrakos +3 位作者 Elizabeth Marlow Elizabeth Mauer Harjot K.Singh Anna M.Demetriades 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第5期789-794,共6页
AIM: To determine relationships between retinal nerve fiber layer(RNFL) thickness and nadir CD4 cell count in human immunodeficiency virus(HIV) positive patients evaluated for glaucoma suspicion.METHODS: Data were rev... AIM: To determine relationships between retinal nerve fiber layer(RNFL) thickness and nadir CD4 cell count in human immunodeficiency virus(HIV) positive patients evaluated for glaucoma suspicion.METHODS: Data were reviewed for 329 HIV positive patients evaluated for glaucoma suspicion. High-definition optical coherence tomography(OCT) RNFL measurements were obtained at least 6 mo apart. Analyses were performed to identify relationships between nadir CD4 count and RNFL thickness.RESULTS: Totally 110 eyes of 55 patients met inclusion criteria, of which 46 eyes were from subjects with nadir CD4<200 cells/mm^3 and 64 had nadir CD4≥200 cells/mm^3. Patients with nadir CD4<200 cells/mm^3 had significantly thicker superior(119.7±18.6 μm) and temporal(63.8±11.7 μm) quadrants at time of initial OCT compared to the superior(112.8±16.8 μm, P=0.048) and temporal(57.1±11.9 μm, P=0.004) quadrants of patients with higher nadir CD4. This trend toward thicker RNFL among subjects with lower nadir CD4 cell counts persisted at the time of follow up OCT where participants with nadir CD4<200 cells/mm^3 showed average RNFL thickness in the superior and temporal quadrants of 117.9±18.3 μm and 63.8±12.8 μm, respectively, compared to a superior thickness of 110.5±16.9 μm(P=0.034) and temporal thickness of 57.3±11.6 μm(P=0.007) among those with higher nadir CD4. CONCLUSION: Patients with lower nadir CD4 cell counts have thicker RNFL in the superior and temporal quadrants compared to those with higher nadir CD4 counts. RNFL thickness in HIV positive patients may be affected by historic HIV disease control and should be considered when evaluating HIV positive patients for glaucoma. 展开更多
关键词 GLAUCOMA GLAUCOMA SUSPECT human IMMUNODEFICIENCY virus retinal nerve fiber layer
原文传递
Retinal vessel diameters and their correlation with retinal nerve fiber layer thickness in patients with pseudoexfoliation syndrome 被引量:3
14
作者 Mehmet Cuneyt Ozmen Zeynep Aktas +2 位作者 Burcin Kepez Yildiz Murat Hasanreisoglu Berati Hasanreisoglu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2015年第2期332-336,共5页
AIM: To compare retinal artery-vein diameters(RAVDs)of patients with pseudoexfoliation(PSX) syndrome with healthy controls and investigate the correlations between retinal nerve fiber layer(RNFL) thickness parameters ... AIM: To compare retinal artery-vein diameters(RAVDs)of patients with pseudoexfoliation(PSX) syndrome with healthy controls and investigate the correlations between retinal nerve fiber layer(RNFL) thickness parameters and RAVDs.METHODS: Seventeen eyes with PSX and 17 eyes of age-matched controls were included in the study. All participants underwent routine ophthalmological examination, Humphrey visual field and RNFL examination by using Stratus OCT. Retinal images were obtained by using a retinal camera(Topcon 501X).RAVDs were measured from inferior nasal, inferior temporal, superior nasal and superior temporal arcuates by using IMAGEnet software. Superior, inferior, nasal,temporal and average RNFL thicknesses were recorded.RAVDs and RNFL parameters in groups and correlations were analyzed by Mann-Whitney U and Spearmann correlation tests.RESULTS: Only inferior quadrant and average RNFL thickness were detected thinner in the PSX group compared with control group(P =0.009, P =0.038,respectively). No statistically significant difference regarding RAVDs was found between two groups.CONCLUSION: RAVDs seems to be comparable in the PSX and control group. RNFL is thinner in the inferior quadrant in the PSX group. RNFL thickness and RAVDs show significant correlations in both groups. This correlation doesn’t seem to be specific to PSX. 展开更多
关键词 PSEUDOEXFOLIATION retinal nerve fiber layer thickness retinal artery-vein diameters
原文传递
The correlation between rat retinal nerve fiber layer thickness around optic disc by using optical coherence tomography and histological measurements 被引量:2
15
作者 Ju-Fang Huang Hui-Min Yu +7 位作者 Lei Shang Ruo-Fei Ma Ngobe Akume Cynthia Yan-Qun Cao Jia Luo Le-Ping Zeng Dan Chen Kun Xiong 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2013年第4期415-421,共7页
·AIM: To explore the correlation between the retinal nerve fiber layer (RNFL) thickness by using optical coherence tomography (OCT) and by histological measurements in normal adult rats and optic nerve transected... ·AIM: To explore the correlation between the retinal nerve fiber layer (RNFL) thickness by using optical coherence tomography (OCT) and by histological measurements in normal adult rats and optic nerve transected rats. · METHODS: The RNFL thickness of 36 rats was scanned in a circle 3.46mm far from the optic disc by OCT. The two experimental groups were the normal group ( =20 rats) and the optic nerve transected group ( =16 rats). The latter group included 4 groups ( =4 /group) surviving for 1 day, 3, 5 and 7 days. Then the RNFL thickness of the same retina area was also measured by NF -200 immunohistochemical staining method. Linear regression was used to analyze the correlation between the data obtained from these two methods. ·RESULTS: The RNFL thickness of normal right eyes around optic disc by OCT was 72.35 ±5.71μm and that of the left eyes was 72.65 ±5.88μm ( =0.074). The RNFL thickness of the corresponding histological section by immunohistochemistry was 37.54 ±4.05μm (right eyes) and 37.38 ±4.23μm (left eyes) ( =0.059). There was a good correlation between the RNFL thickness measured by OCT and that measured by histology (R 2 =0.8131). After optic nerve transection, the trend of the RNFL thickness was thinner with the prolonged survival time. The correlation of the thickness detected by the above two methods was approximately (R 2 =0.8265). Value of the RNFL thickness in rats around optic disc measured by OCT was obviously higher than that measured by common histological measurement in normal adult rats and optic nerve transected rats. ·CONCLUSION: The RNFL thickness measured by OCT has a strong correlation with that measured by histological method. Through OCT scanning, we found that the thickness of RNFL gradually becomes thinner in a time-dependent manner. 展开更多
关键词 retinal nerve fiber layer thickness optical coherence tomography optic nerve transection immunohistochemistry staining relevance analysis RAT
原文传递
Reproducibility of peripapillary retinal nerve fiber layer thickness measurements with Cirrus HD-OCT in glaucomatous eyes 被引量:2
16
作者 Reza Soltani-Moghadam Yousef Alizadeh +1 位作者 Ehsan Kazemnezhad Leili Mohamadreza Absari Haghighi 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2015年第1期113-117,共5页
AIM: To assess the reproducibility of Cirrus high-definition optical coherence tomography(HD-OCT; Carl Zeiss Meditec, Dublin, CA, USA) for analysis of peripapillary retinal nerve fiber layer(RNFL) thickness in glaucom... AIM: To assess the reproducibility of Cirrus high-definition optical coherence tomography(HD-OCT; Carl Zeiss Meditec, Dublin, CA, USA) for analysis of peripapillary retinal nerve fiber layer(RNFL) thickness in glaucomatous eyesMETHODS: Forty-five eyes(one eye from each glaucomatous patient) were imaged with Cirrus HD-OCT.Each eye was imaged three times by two separate operators. Intraclass correlation coefficient(ICC),coefficient of variation(CV), and test-retest variability were evaluated for both intraobserver and interobsever measurementsRESULTS: In intraobserver measurements, the average RNFL thickness ICC was 0.983. CV and test-retest variability were 2.3% and 4.4 μm respectively. In quadrants ICC ranged from 0.886 to 0.956, the lowest associated with nasal quadrant and CV ranged from 3.6%to 7.7%. In interobsever measurements, the average RNFL thickness ICC was 0.979. CV and test-retest variability were 2.4% and 4.5 μm respectively. In quadrants ICC ranged from 0.886 to 0.957, the lowest associated with nasal quadrant and CV ranged from 3.8%to 8.6%.CONCLUSION: The reproducibility of Cirrus OCT for RNFL thickness is sufficiently good to be useful clinically as a measure of glaucoma progression. 展开更多
关键词 opticalcoherencetomography REPRODUCIBILITY GLAUCOMA retinal nerve fiber layer
原文传递
Optical coherence tomography assessed retinal nerve fiber layer thickness in patients with Alzheimer's disease:a meta-analysis 被引量:2
17
作者 Xue-Fei He 1,Yi-Ting Liu 2,Cheng Peng 1,Fan Zhang 1,Shi Zhuang 1,Jin-Song Zhang 1 1Key Laboratory of Lens Research Liaoning Province,Department of Ophthalmology,Eye Hospital of China Medical University,the Fourth Affiliated Hospital of China Medical University Shenyang 110005,Liaoning Province,China 2 Department of Clinical Epidemiology,the First Affiliated Hospital,China Medical University,Shenyang 110001,Liaoning Province,China 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2012年第3期401-405,共5页
AIM:To investigate the difference of retinal nerve fiber layer(RNFL) thickness between Alzheimer's disease patients and normal people,so as to provide clue for the early diagnosis of Alzheimer's disease.·... AIM:To investigate the difference of retinal nerve fiber layer(RNFL) thickness between Alzheimer's disease patients and normal people,so as to provide clue for the early diagnosis of Alzheimer's disease.· METHODS:The articles on the association of RNFL thickness and Alzheimer's disease were retrieved by searching international and national databases.The qualified articles were assessed by meta analysis with Stata11.0 software.The results were pooled using weighted mean difference(WMD) with a corresponding 95% confidence interval(CI).· RESULTS:Totally 7 studies enrolled 324 eyes were included in the meta-analysis.The results of meta analysis showed that in AD patients,there was a significant average RNFL thickness reduction compared with the control group [WMD=-17.561,95%CI:(-23.971,-11.151)].There were significant differences in superior,inferior,nasal and temporal RNFL thickness between the two groups.WMD with a 95%CI were [-18.829,95%CI:(-25.915,-11.743);P<0.05],[-25.775,95%CI:(-34.304,-17.247);P <0.05],[-16.877,95%CI:(-29.141,-4.613);P<0.001] and [-14.565,95%CI:(-28.002,-1.128);P<0.001] respectively.Begg's test and Egger's test did not show significant difference,funnel plot was basically symmetrical,indicating that there was no publication bias existed.· CONCLUSION:There are significant differences in the RNFL thickness in all quadrants between the two groups.RNFL thickness is reduced in AD patients compared with the control group.· 展开更多
关键词 retinal nerve fiber layer thickness optical coherence tomography Alzheimer's disease meta analysis
原文传递
Retinal nerve fiber layer thickness changes in obstructive sleep apnea syndrome:a systematic review and Metaanalysis 被引量:2
18
作者 Jia-Song Wang Hua-Tao Xie +1 位作者 Ye Jia Ming-Chang Zhang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第11期1651-1656,共6页
AIM: To evaluate the retinal nerve fiber layer(RNFL)thickness changes in patients with obstructive sleep apnoea syndrome(OSAS), and detect possible prevalence of glaucoma in this population.METHODS: Comprehensiv... AIM: To evaluate the retinal nerve fiber layer(RNFL)thickness changes in patients with obstructive sleep apnoea syndrome(OSAS), and detect possible prevalence of glaucoma in this population.METHODS: Comprehensive studies were conducted on the Cochrane Library, Pub Med and Embase through March, 2015. Only studies that fit the selection criteria about RNFL and OSAS would be included. For the measures, we calculated the 95% confidence interval(CI)and weighted mean differences(WMD). The systematic review and Meta-analysis was performed by Rev Man 5.2software.RESULTS: Nine case-control studies were analyzed containing a total of 1086 cases and 580 controls.Average RNFL thickness in OSAS was reduced significantly compared with healthy controls in random effects model(WMD =-2.56, 95% CI:-4.82 to-0.31, P =0.003, I2=57%). A significant RNFL thickness reduction were found between the two groups in inferior quadrant(WMD =-3.11, 95% CI:-5.53 to-0.69, P =0.01), superior quadrant(WMD =-2.37, 95% CI:-4.7 to 0.04, P =0.05). In nasal quadrant(WMD =-2.54, 95% CI:-6.53 to 1.45, P =0.21) and temporal quadrant(WMD=-1.26, 95% CI:-2.19 to 0.47, P =0.15) there was no difference of RNFL thickness between the two groups.CONCLUSION: The results show that RNFL thickness is lower in patients with moderate or severe OSAS than in normal subjects or patients with mild OSAS according to the nine homogeneity studies. 展开更多
关键词 retinal nerve fiber layer thickness obstructive sleep apnea syndrome META-ANALYSIS
原文传递
Comparison of the Diagnostic Ability of Retinal Nerve Fiber Layer Thickness Measured using Time Domain and Spectral Domain Optical Coherence Tomography in Primary Open Angle Glaucoma 被引量:11
19
作者 Lina Huang Ning Fan Xiaoli Shen Jing He 《Eye Science》 CAS 2011年第3期132-137,142,共7页
Purpose:To evaluate and compare the diagnostic ability of retinal nerve fiber layer (RNFL) thickness measurements using time domain (Stratus) and spectral domain (Cirrus HD) optical coherence tomography(OCT).in preper... Purpose:To evaluate and compare the diagnostic ability of retinal nerve fiber layer (RNFL) thickness measurements using time domain (Stratus) and spectral domain (Cirrus HD) optical coherence tomography(OCT).in preperimetric and early primary open angle glaucoma (POAG). Methods:A total of 62 eyes from 62 normal subjects,47 eyes from 47 early perimetric damage POAG patients and 30 eyes from 30 preperimetric glaucoma patients were chosen in the study.All the subjects underwent peripapillary RNFL thickness measurements using Stratus OCT and Cirrus HD-OCT on the same day by a single trained operator.The RNFL thickness measured by Stratus OCT and Cirrus HD-OCT was statistically compared using paired t-tests.The relationship between RNFL thickness measured by two OCT instruments was evaluated using Pearson's correlation coefficient.Areas under the receiver operating characteristic curves (AROC) were calculated and compared. Results:RNFL thickness measured using Stratus OCT was generally thicker than that using Cirrus HD-OCT(P<0.05). A highly significant correlation between the two OCT instruments measurements was found in four quadrants and average RNFL thickness measurements (P<0.001). The average RNFL thickness of Cirrus HD-OCT had significantly(P=0.006) higher diagnostic ability (AROC=0.951) than that of Stratus OCT(AROC=0.881) in preperimetric glaucoma. There were no significant differences between the AROCs for other RNFL thickness parameters from Cirrus HD-OCT and Stratus OCT in preperimetric and early glaucoma(P>0.05). Conclusion: Significant differences and an excellent correlation were noted in terms of RNFL thickness measurements using Stratus OCT and Cirrus HD-OCT. Cirrus HD-OCT presented higher diagnostic ability for preperimetric glaucoma. 展开更多
关键词 厚度测量 诊断能力 扫描测量 光学相干 断层扫描 青光眼 纤维层 视网膜
下载PDF
Comparison of peripapillary retinal nerve fiber layer thickness between myopia severity groups and controls 被引量:7
20
作者 Evelyn Li Min Tai Jiunn Loong Ling +2 位作者 Eng Hui Gan Hussein Adil Wan-Hiram Wan-Hazabbah 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第2期274-278,共5页
AIM: To compare the peripapillary retinal nerve fiber layer(RNFL) thickness measured via optical coherence tomography(OCT) between different groups of myopia severity and controls. METHODS: This was a prospectiv... AIM: To compare the peripapillary retinal nerve fiber layer(RNFL) thickness measured via optical coherence tomography(OCT) between different groups of myopia severity and controls. METHODS: This was a prospective cross-sectional study. All subjects underwent a full ophthalmic examination, refraction, visual field analysis and A-scan biometry. Myopic patients were classified as low myopia(LM) [spherical equivalent(SE) from greater than-0.5 D, up to-3.0 D], moderate myopia(MM; SE greater than-3.0 D, up to-6.0 D) and high myopia(HM; SE greater than-6.0 D). The control group consisted of emmetropic(EM) patients(SE from +0.5 D to-0.5 D). A Zeiss Cirrus HD-OCT machine was used to measure the peripapillary RNFL thickness of both eyes of each subject. The mean peripapillary RNFL thickness between groups was compared using both analysis of variance and analysis of covariance.RESULTS: A total of 403 eyes of 403 subjects were included in this study. The mean age was 31.48±10.23 y. There were 180(44.7%) eyes with EM, 124(30.8%) with LM, 73(18.1%) with MM and 26(6.5%) with HM. All groups of myopia severity had a thinner average RNFL than the EM group, but after controlling for gender, age, and axial eye length, only the HM group differed significantly from the EM group(P=0.017). Likewise, the superior, inferior and nasal RNFL was thinner in all myopia groups compared to controls, but after controlling for confounders, only the inferior quadrant RNFL was significantly thinner in the HM group, when compared to the EM group(P=0.017). CONCLUSION: The average and inferior quadrant RNFL is thinner in highly myopic eyes compared to emmetropic eyes. Refractive status must be taken into consideration when interpreting the OCT of myopic patients, as RNFL thickness varies with the degree of myopia. 展开更多
关键词 optical coherence tomography retinal nerve fiber layer myopia
原文传递
上一页 1 2 30 下一页 到第
使用帮助 返回顶部