With a rapidly increasing demand and widespread use of radiotherapy treatment, the subject area of in-vivo real time dose rate dosimeters has become a significant area of study. An embedded structure fiber-optic radia...With a rapidly increasing demand and widespread use of radiotherapy treatment, the subject area of in-vivo real time dose rate dosimeters has become a significant area of study. An embedded structure fiber-optic radiation dosimeter has proved to be a promising candidate to fulfil this role because of its high SNR (signal-to-noise ratio) and excellent light conversion efficiency. In this paper, the properties of this kind of dosimeter with respect to different SSD (Source to Surface Distance) and beam field size in a clinical Linac are studied. The characteristics of the dosimeter were evaluated by the sensor’s output intensity response in these conditions.展开更多
Measurement of dose distribution in patients during radiotherapy is impossible. The Monte Carlo simulation is an alternative method for dose calculations. In routine radiotherapy, the source-to-surface distance(SSD)me...Measurement of dose distribution in patients during radiotherapy is impossible. The Monte Carlo simulation is an alternative method for dose calculations. In routine radiotherapy, the source-to-surface distance(SSD)method is not practical for an isocentric unit because it requires numerous values of tissue–air ratios and inverse square law. Therefore, this method is time consuming. In this paper, the curves of relative depth doses were obtained for three different SSDs using the MCNP4C Monte Carlo simulation and approximated with a single curve called calibration curve. This curve was compared to the curve obtained by published data, differing in approximately 5% in the worst case. It was also observed that the obtained results were more accurate for distances between-5 and 10 cm from source-to-axis distance.展开更多
文摘With a rapidly increasing demand and widespread use of radiotherapy treatment, the subject area of in-vivo real time dose rate dosimeters has become a significant area of study. An embedded structure fiber-optic radiation dosimeter has proved to be a promising candidate to fulfil this role because of its high SNR (signal-to-noise ratio) and excellent light conversion efficiency. In this paper, the properties of this kind of dosimeter with respect to different SSD (Source to Surface Distance) and beam field size in a clinical Linac are studied. The characteristics of the dosimeter were evaluated by the sensor’s output intensity response in these conditions.
文摘Measurement of dose distribution in patients during radiotherapy is impossible. The Monte Carlo simulation is an alternative method for dose calculations. In routine radiotherapy, the source-to-surface distance(SSD)method is not practical for an isocentric unit because it requires numerous values of tissue–air ratios and inverse square law. Therefore, this method is time consuming. In this paper, the curves of relative depth doses were obtained for three different SSDs using the MCNP4C Monte Carlo simulation and approximated with a single curve called calibration curve. This curve was compared to the curve obtained by published data, differing in approximately 5% in the worst case. It was also observed that the obtained results were more accurate for distances between-5 and 10 cm from source-to-axis distance.