Objective:To explore the feasibility of remotely obtaining complex information on traditional Chinese medicine(TCM)pulse conditions through voice signals.Methods: We used multi-label pulse conditions as the entry poin...Objective:To explore the feasibility of remotely obtaining complex information on traditional Chinese medicine(TCM)pulse conditions through voice signals.Methods: We used multi-label pulse conditions as the entry point and modeled and analyzed TCM pulse diagnosis by combining voice analysis and machine learning.Audio features were extracted from voice recordings in the TCM pulse condition dataset.The obtained features were combined with information from tongue and facial diagnoses.A multi-label pulse condition voice classification DNN model was built using 10-fold cross-validation,and the modeling methods were validated using publicly available datasets.Results: The analysis showed that the proposed method achieved an accuracy of 92.59%on the public dataset.The accuracies of the three single-label pulse manifestation models in the test set were 94.27%,96.35%,and 95.39%.The absolute accuracy of the multi-label model was 92.74%.Conclusion: Voice data analysis may serve as a remote adjunct to the TCM diagnostic method for pulse condition assessment.展开更多
Application of Unmanned Aircraft Systems(UAS)for plant protection is becoming a common tool in agricultural field management.To avoid shortcomings of intrusive flowrate sensors including poor measurement accuracy and ...Application of Unmanned Aircraft Systems(UAS)for plant protection is becoming a common tool in agricultural field management.To avoid shortcomings of intrusive flowrate sensors including poor measurement accuracy and poor anti-vibration ability,a non-intrusive flowrate measurement and monitoring system of plant-protection UAS was developed based on pump voice signal analysis.It is mainly composed of STM32 processor,microphone and signal-conditioning circuit.By collecting and analyzing the voice signal of the pump in the UAS,the monitoring system will output the real-time values of spraying flowrate and amount.An extraction model was developed to determine operation status and primary frequency of the pump based on voice signal analysis.Real-time spray flowrate can be determined from the real-time extracted primary frequency and the fitted correlation formulas of spraying flowrate under outlet area and pump primary frequency.The flowrate correlation equation of one certain pump from 4-rotor UAS 3WQFTX-1011S was obtained,the max deviation rate of fitted spray flowrate was only 2.8%.In primary frequency extraction test,the error rate of primary frequency extraction was less than 1%.In the 4-rotor UAS flight tests:the max deviation of operating starting/end point was only 0.7 s and the max deviation of extracted total operating time was only 0.8 s;the deviation of extracted spray flowrate was less than 2%,and the max deviation rate of total spray amount was 3.2%.This research could be used as a guidance for plant-protection UAS non-intrusive flowrate measurement and monitoring.展开更多
Evaluation of quality of singing is an issue subjectively realized by the experts. This paper presents the results of the analysis of the vibrato parameter in the singing. The well-known fact is the existence of vibra...Evaluation of quality of singing is an issue subjectively realized by the experts. This paper presents the results of the analysis of the vibrato parameter in the singing. The well-known fact is the existence of vibrato of sufficient quality in the voices of professional singers. The authors focus here on the choral voices to assess the quality of their singing from the point of view of the vibrato parameter. The method presented here is developed to evaluate the vibrato while singing under conditions close to the real ones. The study was carried out on the recordings of the members of an academic choir. As a result of tests it was found that not all singers present the same quality of vibrato in terms of deviation of vibrato confidence (STDCV).展开更多
基金supported by Fundamental Research Funds from the Beijing University of Chinese Medicine(2023-JYB-KYPT-13)the Developmental Fund of Beijing University of Chinese Medicine(2020-ZXFZJJ-083).
文摘Objective:To explore the feasibility of remotely obtaining complex information on traditional Chinese medicine(TCM)pulse conditions through voice signals.Methods: We used multi-label pulse conditions as the entry point and modeled and analyzed TCM pulse diagnosis by combining voice analysis and machine learning.Audio features were extracted from voice recordings in the TCM pulse condition dataset.The obtained features were combined with information from tongue and facial diagnoses.A multi-label pulse condition voice classification DNN model was built using 10-fold cross-validation,and the modeling methods were validated using publicly available datasets.Results: The analysis showed that the proposed method achieved an accuracy of 92.59%on the public dataset.The accuracies of the three single-label pulse manifestation models in the test set were 94.27%,96.35%,and 95.39%.The absolute accuracy of the multi-label model was 92.74%.Conclusion: Voice data analysis may serve as a remote adjunct to the TCM diagnostic method for pulse condition assessment.
基金The research was supported by National Key R&D Program of China(Grant No.2017YFD0701000,2018YFD0200900)China Agriculture Research System of MOF and MARA(Grant No.CARS-12)Chinese Academy of Agricultural Sciences Fundamental Research Funds(Grant No.SR201903).
文摘Application of Unmanned Aircraft Systems(UAS)for plant protection is becoming a common tool in agricultural field management.To avoid shortcomings of intrusive flowrate sensors including poor measurement accuracy and poor anti-vibration ability,a non-intrusive flowrate measurement and monitoring system of plant-protection UAS was developed based on pump voice signal analysis.It is mainly composed of STM32 processor,microphone and signal-conditioning circuit.By collecting and analyzing the voice signal of the pump in the UAS,the monitoring system will output the real-time values of spraying flowrate and amount.An extraction model was developed to determine operation status and primary frequency of the pump based on voice signal analysis.Real-time spray flowrate can be determined from the real-time extracted primary frequency and the fitted correlation formulas of spraying flowrate under outlet area and pump primary frequency.The flowrate correlation equation of one certain pump from 4-rotor UAS 3WQFTX-1011S was obtained,the max deviation rate of fitted spray flowrate was only 2.8%.In primary frequency extraction test,the error rate of primary frequency extraction was less than 1%.In the 4-rotor UAS flight tests:the max deviation of operating starting/end point was only 0.7 s and the max deviation of extracted total operating time was only 0.8 s;the deviation of extracted spray flowrate was less than 2%,and the max deviation rate of total spray amount was 3.2%.This research could be used as a guidance for plant-protection UAS non-intrusive flowrate measurement and monitoring.
基金supported by the Ministry of Science and Higher Education of Poland,under Grant No.NN516 517539
文摘Evaluation of quality of singing is an issue subjectively realized by the experts. This paper presents the results of the analysis of the vibrato parameter in the singing. The well-known fact is the existence of vibrato of sufficient quality in the voices of professional singers. The authors focus here on the choral voices to assess the quality of their singing from the point of view of the vibrato parameter. The method presented here is developed to evaluate the vibrato while singing under conditions close to the real ones. The study was carried out on the recordings of the members of an academic choir. As a result of tests it was found that not all singers present the same quality of vibrato in terms of deviation of vibrato confidence (STDCV).