期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Effects of high-pressure activated slightly acidic electrolyzed water on cleaning and sterilization of pig transfer vehicles
1
作者 Xuedong Zhao Shengnan Tao +2 位作者 Fei Qi Hao Li Zhengxiang Shi 《International Journal of Agricultural and Biological Engineering》 SCIE 2024年第4期53-59,共7页
The establishment of biosafety system is of enormous importance to the livestock and poultry production in terms of mitigating the transmission of diseases and implementing regional prevention and control measures.How... The establishment of biosafety system is of enormous importance to the livestock and poultry production in terms of mitigating the transmission of diseases and implementing regional prevention and control measures.However,the current sterilization technology presents several drawbacks,including time-consuming procedures,chemical residues,and challenges in treating the sewage after rinsing.In this study,a novel cleaning and sterilization method that combines slightly acidic electrolyzed water and high pressure water-jet was developed.An orthogonal test was conducted to examine the correlation between high-pressure conditions and the various non-structural parameters on the efficacy of sterilization rate.In a field test,the effectiveness of the technology in cleaning pig transfer vehicles was evaluated by the total plate count and variations of community composition.The findings revealed that the combination of process parameters,including an available chlorine concentration of 200 mg/L,rinsing pressure of 170 bar,rinsing duration of 10 s,and residence time of 15 min,resulted in a removal rate of colony concentration on the surface of pig transfer vehicles of(96.50±0.91)%.Moreover,it was demonstrated to effectively inhibit a variety of pathogenic bacteria.The innovative cleaning system has the potential to replace traditional methods and reduces pollution while saving time and labor.It introduces a novel approach for sterilization of transportation in livestock and poultry farms as well as the biosafety construction of the animal husbandry. 展开更多
关键词 slightly acidic electrolyzed water high pressure water-jet STERILIZATION BIOSAFETY concentrated animal production
原文传递
Preservative effects of the combined treatment of slightly acidic electrolyzed water and ice on pomfret 被引量:1
2
作者 Xiaoling Huang Songming Zhu +3 位作者 Xiaomin Zhou Jinsong He Yong Yu Zhangying Ye 《International Journal of Agricultural and Biological Engineering》 SCIE EI CAS 2021年第1期230-236,共7页
This study assessed the combined effect of slightly acidic electrolyzed water(SAEW)and slightly acidic electrolyzed water ice(SAEW-ice)on the quality of pomfrets over a period of 18 d of cold storage at 4°C.A pre... This study assessed the combined effect of slightly acidic electrolyzed water(SAEW)and slightly acidic electrolyzed water ice(SAEW-ice)on the quality of pomfrets over a period of 18 d of cold storage at 4°C.A presoak for 5 min in SAEW solution(22 mg/L)was used before the pomfrets were placed on SAEW-ice(pH:6.45;ORP:803 mV;ACC:18 mg/L);The changes in physicochemical properties(i.e.,pH,thiobarbituric acid,total volatile basic nitrogen and texture profile),microbial loads and sensory characteristics were all analyzed.Compared with the tap water(TW)group,the total bacterial counts of the SAEW group significantly decreased by 1.27 log10 CFU/g after immersion(p<0.05).The shelf life of the pomfrets was prolonged by 9 d by the combined treatment of SAEW and SAEW-ice during storage at 4℃.On the 18th day,the gumminess and chewiness values of the pomfrets in the SAEW+SAEW-ice group were 195 g and 3.97 mJ,respectively,which were significantly higher than those of the other groups(p<0.05).The results suggested that SAEW+SAEW-ice treatments have great potential as a novel method to maintain the quality and extend the shelf life of pomfrets during refrigerated storage. 展开更多
关键词 POMFRET slightly acidic electrolyzed water slightly acidic electrolyzed water ice storage quality PRESERVATION
原文传递
Inactivation efficiency of slightly acidic electrolyzed water against microbes on facility surfaces in a disinfection channel 被引量:2
3
作者 Zang Yitian Li Baoming +3 位作者 Shi Zhengxiang Sheng Xiaowei Wu Hongxiang Shu Dengqun 《International Journal of Agricultural and Biological Engineering》 SCIE EI CAS 2017年第6期23-30,共8页
Slightly acidic electrolyzed water(SAEW,pH 6.0-6.5)is an ideal and environmentally-friendly disinfectant,which was used to prevent and control bacterial infections on farms.This work aims to investigate the inactivati... Slightly acidic electrolyzed water(SAEW,pH 6.0-6.5)is an ideal and environmentally-friendly disinfectant,which was used to prevent and control bacterial infections on farms.This work aims to investigate the inactivation effectiveness of SAEW in inactivating microbes in a disinfection channel.The bactericidal efficiency of SAEW on equipment surfaces was compared to two commercial disinfectants,Kuei A bromide solution(KAS,5:1000 v/v)and Glutaraldehyde solution(GS,5:1000 v/v).The disinfection effectiveness of SAEW in inactivating Salmonella enteritidis(S.enteritidis)on equipment surfaces in the disinfection channel was evaluated,and a model was developed using multiple linear regression analysis.Results indicated that SAEW was significantly(p<0.05)more efficient than KAS and GS on kits and clothing in the disinfection channel at 1 min.The SAEW did not contribute as aggressively to respiratory difficulty as KAS and GS.Maximum reductions of 2.362 log10 CFU/cm^(2),2.613 log10 CFU/cm^(2) and 2.359 log10 CFU/cm^(2) for Salmonella enteritidis were obtained from clothing surfaces,iron materials,and kits treated with SAEW for 2.5 min at a chlorine concentration of 220 mg/L.Moreover,the established model had a good fit-quantified by the determination coefficient R^(2)(0.939)and a lack of fit test(p>0.05).In addition,available chlorine concentration(ACC)was an important factor than other factors,and the inactivation efficiency of Salmonella enteritidis sprayed by SAEW treatment was different between iron materials,kits and clothing surfaces(iron>kit>clothing). 展开更多
关键词 slightly acidic electrolyzed water disinfection channel S.enteritidis DISINFECTION bacterial infection prevention and control livestock farm
原文传递
Disinfection effect of adding slightly acidic electrolyzed water to artificial seawater under the condition of static hybrid
4
作者 Chunfang Wang Xiaoling Huang +3 位作者 Shuo Wang Yong Yu Songming Zhu Zhangying Ye 《International Journal of Agricultural and Biological Engineering》 SCIE EI CAS 2020年第2期218-222,共5页
Mixed solution of slightly acidic electrolyzed water(SAEW)and artificial seawater was used to investigate the disinfection potential of SAEW in artificial seawater.Inoculated Vibrio parahaemolyticus(suspended in 3%sod... Mixed solution of slightly acidic electrolyzed water(SAEW)and artificial seawater was used to investigate the disinfection potential of SAEW in artificial seawater.Inoculated Vibrio parahaemolyticus(suspended in 3%sodium chloride alkaline peptone water and 0.85%sodium chloride water,respectively)was subjected to different mixed-SAEW and SAEW immersion treatments(5-20 mg/L available chlorine concentration(ACC)).In the presence of organic matter,4.07 logCFU/mL significant reduction(p<0.05)was achieved after treating with 20 mg/L mixed-SAEW for 15 min.There was 5.13 logCFU/mL reduction after treating with 15 mg/L SAEW for 15 min.For V.parahaemolyticus suspended in 0.85%sodium chloride solution,it was undetected after 30 s SAEW treatment(5 mg/L ACC)or 120 s mixed-SAEW treatment(10 mg/L ACC).At a ratio of SAEW and artificial seawater at 1:15(V/V),SAEW could inactivate V.parahaemolyticus to undetectable level in artificial seawater in one minute,which was comparable with UV treatment of 10 W.The results indicated high sanitization potential of SAEW against V.parahaemolyticus in aquaculture seawater. 展开更多
关键词 slightly acidic electrolyzed water DISINFECTION INACTIVATION Vibrio parahaemolyticus artificial seawater ULTRAVIOLET
原文传递
Bactericidal efficacy of slightly acidic electrolyzed water(SAEW)against Listeria monocytogenes planktonic cells and biofilm on food-contact surfaces
5
作者 Jianxiong Hao Junyi Zhang +1 位作者 Xueqi Zheng Dandan Zhao 《Food Quality and Safety》 SCIE CSCD 2022年第2期225-233,共9页
In the present study,the bactericidal efficacy of slightly acidic electrolyzed water(SAEW)against Listeria monocytogenes(L.monocytogenes)planktonic cells and biofilm on food-contact surfaces including stainless steel ... In the present study,the bactericidal efficacy of slightly acidic electrolyzed water(SAEW)against Listeria monocytogenes(L.monocytogenes)planktonic cells and biofilm on food-contact surfaces including stainless steel and glass was systematically evaluated.The results showed that SAEW(pH 5.09 and available chlorine concentration(ACC)of 60.33 mg/L)could kill L.monocytogenes on food-contact surfaces completely in 30 s,a disinfection efficacy equal to that of NaCIO solutions(pH 9.23 and ACC of 253.53 mg/L).The results showed that long exposure time and high ACC contributed to the enhancement of the disinfection efficacy of SAEW on L.monocytogenes on food-contact surfaces.Moreover,the log reduction of SAEW treatment presented an increasing tendency within the prolonging of treatment time when SAEW was used to remove the L.monocytogenes bioflm formed on stainless steel and glass surfaces,which suggested that SAEW could remove L.monocytogenes bio-film effectively and its disinfection efficacy is equal to(in the case of stainless steel)or higher than(in the case of glass)that of high-ACC NaCIO solutions.In addition,the results of the crystal violet staining and scanning electron microscopy also demonstrated that SAEW treatment could remove the L.monocytogenes biofilm on food-contact surfaces. 展开更多
关键词 Slightly acidic electrolyzed water Listeria monocytogenes biofilm food-contact surface
原文传递
Electrolyzed water and its application in animal houses 被引量:8
6
作者 Weichao ZHENG Li NI Baoming LI 《Frontiers of Agricultural Science and Engineering》 2016年第3期195-205,共11页
Electrolyzed water(EW) can be produced by electrolysis of a dilute salt solution. Slightly acidic electrolyzed water(SAEW, p H 5.0–6.5) and neutral electrolyzed water(NEW, p H 6.5–8.5) are considered healthy and env... Electrolyzed water(EW) can be produced by electrolysis of a dilute salt solution. Slightly acidic electrolyzed water(SAEW, p H 5.0–6.5) and neutral electrolyzed water(NEW, p H 6.5–8.5) are considered healthy and environmentally friendly because no hazardous chemicals are added in its production, there is reduced corrosion of surfaces and it minimizes the potential for damage to animal and human health. Over the last decade, EW has become increasingly popular as an alternative disinfectant for decontamination in animal houses. However, there have been some issues related to EW that are not well known, including different mechanisms for generation of SAEW and NEW, and the antimicrobial mechanism of EW. This review covers the definitions of SAEW and NEW, different generation systems for SAEW and NEW, the antimicrobial mechanism of EW, and recent developments related to the application of SAEW and NEW in animal houses. 展开更多
关键词 DISINFECTION poultry and livestock slightly acidic electrolyzed water neutral electrolyzed water
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部