期刊文献+
共找到1,152篇文章
< 1 2 58 >
每页显示 20 50 100
Experimental investigation of axially loaded steel fiber reinforced high strength concrete-filled steel tube columns 被引量:9
1
作者 卢亦焱 李娜 +1 位作者 李杉 梁鸿骏 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第6期2287-2296,共10页
An experimental study on the compressive behavior of steel fiber reinforced concrete-filled steel tube columns is presented. Specimens were tested to investigate the effects of the concrete strength, the thickness of ... An experimental study on the compressive behavior of steel fiber reinforced concrete-filled steel tube columns is presented. Specimens were tested to investigate the effects of the concrete strength, the thickness of steel tube and the steel fiber volume fraction on the ultimate strength and the ductility. The experimental results indicate that the addition of steel fibers in concrete can significantly improve the ductility and the energy dissipation capacity of the concrete-filled steel tube columns and delay the local buckling of the steel tube, but has no obvious effect on the failure mode. It has also been found that the addition of steel fibers is a more effective method than using thicker steel tube in enhancing the ductility, and more advantageous in the case of higher strength concrete. An analytical model to estimate the load capacity is proposed for steel tube columns filled with both plain concrete and steel fiber reinforced concrete. The predicted results are in good agreement with the experimental ones obtained in this work and literatures. 展开更多
关键词 concrete-filled steel tube (CFST) zolumns steel fiber high strength concrete axial load DUCTILITY load capacity
下载PDF
Seismic performance of recycled concrete-filled square steel tube columns 被引量:9
2
作者 Chen Zongping Jing Chenggui +1 位作者 Xu Jinjun Zhang Xianggang 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2017年第1期119-130,共12页
An experimental study on the seismic performance of recycled concrete-filled square steel tube (RCFST) columns is carried out. Six specimens were designed and tested under constant axial compression and cyclic later... An experimental study on the seismic performance of recycled concrete-filled square steel tube (RCFST) columns is carried out. Six specimens were designed and tested under constant axial compression and cyclic lateral loading. Two parameters, replacement percentage of recycled coarse aggregate (RCA) and axial compression level, were considered in the test. Based on the experimental data, the hysteretic loops, skeleton curves, ductility, energy dissipation capacity and stiffness degradation of RCFST columns were analyzed. The test results indicate that the failure modes of RCFST columns are the local buckling of the steel tube at the bottom of the columns, and the hysteretic loops are full and their shapes are similar to normal CFST columns. Furthermore, the ductility coefficient of all specimens are close to 3.0, and the equivalent viscous damping coefficient corresponding to the ultimate lateral load ranges from 0.323 to 0.360, which demonstrates that RCFST columns exhibit remarkable seismic performance. 展开更多
关键词 recycled concrete-filled square steel tube (RCFST) COLUMN replacement percentage cyclic loading seismicperformance
下载PDF
Axial Compression Behavior and Analytical Method of L-Shaped Column Composed of Concrete-Filled Square Steel Tubes 被引量:5
3
作者 荣彬 陈志华 +1 位作者 APOSTOLOS Fafitis 杨楠 《Transactions of Tianjin University》 EI CAS 2012年第3期180-187,共8页
Based on the characteristics of an L-shaped column composed of concrete-filled square steel tubes, the axial compression experiment and nonlinear finite element analysis were carried out to study the mechanical proper... Based on the characteristics of an L-shaped column composed of concrete-filled square steel tubes, the axial compression experiment and nonlinear finite element analysis were carried out to study the mechanical property of the L-shaped column. The load-displacement curve for the L-shaped column, the deflection and load-strain curves for the mono columns were obtained by the axial compression experiment. The results show that the L-shaped column exhibits a flexural-torsional buckling failure mode. The numerical simulation by the finite element analysis shows that the bearing capacity and failure mode are in accordance with those of the axial compression experiment and the feasi- bility of the finite element analysis is proved. For the calculation of the bearing capacity of the L-shaped column com- posed of concrete-filled square steel tubes, an analytical method is proposed based on the theory of the elastic stability and spatial truss model. The results of the analytical method are in good agreement with those of the axial compression experiment and the finite element analysis. 展开更多
关键词 L-shaped column concrete-filled square steel tube axial compression experiment finite element analy-sis analytical method
下载PDF
Effect of contact thermal resistance on temperature distributions of concrete-filled steel tubes in fire 被引量:5
4
作者 吕学涛 杨华 张素梅 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2011年第1期81-88,共8页
To predicate the temperature distribution of concrete-filled steel tubes(CFSTs) being exposure to fire,a finite element analysis model was developed using a finite element package,ANSYS.A suggested value of contact th... To predicate the temperature distribution of concrete-filled steel tubes(CFSTs) being exposure to fire,a finite element analysis model was developed using a finite element package,ANSYS.A suggested value of contact thermal resistance was therefore proposed with the supporting of massive numbers of collected test data.Parametric analysis was conducted subsequently towards the cross-sectional temperature distribution of CFST columns in four-side fire,in which the exposure time,width of the cross section,steel ratio were taken into account with considering contact thermal resistance.It was found that contact thermal resistance has little effect on the overall temperature regulation with the exposure time,the width of cross-section or the change of steel ratio.However,great temperature dropping at the concrete adjacent to the contact interface,and gentle temperature increase at steel tube,exist if considering contact thermal resistance.The results of the study are expected to provide theoretical basis for the fire resistance behavior and design of the CFST columns being exposure to fire. 展开更多
关键词 contact thermal resistance temperature distribution concrete-filled steel tube heal transfer
下载PDF
Bending behaviour of lightweight aggregate concrete-filled steel tube spatial truss beam 被引量:3
5
作者 傅中秋 吉伯海 +1 位作者 朱伟 葛汉彬 《Journal of Central South University》 SCIE EI CAS CSCD 2016年第8期2110-2117,共8页
A lightweight aggregate concrete-filled steel tube(LACFST) spatial truss beam was tested under bending load. The performance was studied by the analysis of the beam deflection and strains in its chords and webs. Accor... A lightweight aggregate concrete-filled steel tube(LACFST) spatial truss beam was tested under bending load. The performance was studied by the analysis of the beam deflection and strains in its chords and webs. According to the test results, several assumptions were made to deduce the bearing capacity calculation method based on the force balance of the whole section. An optimal dimension relationship for the truss beam chords was proposed and verified by finite element analysis. Results show that the LACFST spatial truss beam failed after excessive deflection. The strain distribution agreed with Bernoulli-Euler theoretical prediction. The truss beam flexural bearing capacity calculation results matched test evidence with only a 3% difference between the two. Finite element analyses with different chord dimensions show that the ultimate bearing capacity increases as the chord dimensions increase when the chords have a diameter smaller than optimal one; otherwise, it remains almost unchanged as the chord dimensions increase. 展开更多
关键词 lightweight aggregate concrete-filled steel tube spatial truss beam bending behaviour bearing capacity
下载PDF
Application of Compactness Detection to Complicated Concrete-Filled Steel Tube by Ultrasonic Method 被引量:1
6
作者 杨建江 王飞 +1 位作者 陆苏亮 王川 《Transactions of Tianjin University》 EI CAS 2014年第2期126-132,共7页
An example of using ultrasonic method to detect the compactness of complicated concrete-filled steel tube in certain high-rise building was discussed in this study.Because of the particularity of the complicated concr... An example of using ultrasonic method to detect the compactness of complicated concrete-filled steel tube in certain high-rise building was discussed in this study.Because of the particularity of the complicated concrete-filled steel tubular column,the plane detection method and embedded sounding pipe method were adopted in the process of effectively detecting the column.According to the results of the plane detection method and embedded sounding pipe method,the cementing status of steel tube and concrete can be concluded,which cannot be judged by the hammering method in the rectangular steel tube-reinforced concrete. 展开更多
关键词 ultrasonic method concrete-filled steel tube plane detection method embedded sounding pipe method COMPACTNESS
下载PDF
Concrete-Filled Steel Tube Arch Bridges in China 被引量:70
7
作者 Jielian Zheng Jianjun wang 《Engineering》 2018年第1期143-155,共13页
In the past 20 years, great progress has been achieved in China in the construction of concrete-filled steel tube (CFST) arch bridges and concrete arch bridges with a CFST skeleton. The span of these bridges has bee... In the past 20 years, great progress has been achieved in China in the construction of concrete-filled steel tube (CFST) arch bridges and concrete arch bridges with a CFST skeleton. The span of these bridges has been increasing rapidly, which is rare in the history of bridge development. The large-scale construction of expressways and high-speed railways demands the development of long-span arch bridges, and advances in design and construction techniques have made it possible to construct such bridges. In the present study, the current status, development, and major innovative technologies of CFST arch bridges and concrete arch bridges with a CFST skeleton in China are elaborated. This paper covers the key con- struction technologies of CFST arch bridges, such as the design, manufacture, and installation of steel tube arch trusses, the preparation and pouring of in-tube concrete, and the construction of the world's longest CFST arch bridge-the First Hejiang Yangtze River Bridge. The main construction technologies of rein- forced concrete arch bridges are also presented, which include cable-stayed fastening-hanging cantilever assembly, adjusting the load by means of stay cables, surrounding the concrete for arch rib pouring, and so forth. In addition, the construction of two CFST skeleton concrete arch bridges-the Guangxi Yongning Yong River Bridge and the Yunnan-Guangxi Railway Nanpan River Bridge--is discussed. CFST arch bridges in China have already gained a world-leading position; with the continuous innovation of key technologies, China will become the new leader in promoting the development of arch bridges. 展开更多
关键词 concrete-filled steel tube (CFST) ARCH BRIDGE steel-reinforced CONCRETE ARCH BRIDGE CABLE-STAYED fastening-hanging cantileverassembly VACUUM-ASSISTED pouring in-tube CONCRETE Adjusting load by stay cables
下载PDF
Reliability analysis of circular concrete-filled steel tube with material and geometrical nonlinearity 被引量:1
8
作者 Tengfei XU Tianyu XIANG +1 位作者 Yulin ZHAN Renda ZHAO 《Journal of Modern Transportation》 2012年第3期138-147,共10页
Most of the previous research on concrete-filled steel tube is restricted to a deterministic approach. To gain clear insight into the random properties of circular concrete-filled steel tube, reliability analysis is c... Most of the previous research on concrete-filled steel tube is restricted to a deterministic approach. To gain clear insight into the random properties of circular concrete-filled steel tube, reliability analysis is carried out in the present study. To obtain the Structural nonlinear response and ultimate resistance capacity, material and geometrical nonlinear analysis of circular concrete-filled steel tube is performed with a three-dimensional degenerated beam ele- ment. Then we investigate the reliability of concrete-filled steel tube using the first-order reliability method combined with nonlinear finite element analysis. The influences of such parameters as material strength, slenderness, initial geo- metrical imperfection, etc. on the reliability of circular concrete-filled steel tube column are studied. It can be con- cluded that inevitable random fluctuation of those parameters has significant influence on structural reliability, and that stochastic or reliability methods can provide a more rational and subjective evaluation on the safety of CFT structures than a deterministic approach. 展开更多
关键词 concrete-filled steel tube RELIABILITY material nonlinearity geometrical nonlinearity
下载PDF
Ductility and Ultimate Capacity of Concrete-Filled Lattice Rectangular Steel Tube Columns
9
作者 Chengquan Wang Yun Zou +3 位作者 Tianqi Li Jie Ding Xiaoping Feng Tiange Lei 《Structural Durability & Health Monitoring》 EI 2018年第2期99-110,共12页
A kind of concrete-filled lattice rectangular steel tube(CFLRST)column was put forward.The numerical simulation was modeled to analyze the mechanical characteristic of CFLRST column.By comparing the load-deformation c... A kind of concrete-filled lattice rectangular steel tube(CFLRST)column was put forward.The numerical simulation was modeled to analyze the mechanical characteristic of CFLRST column.By comparing the load-deformation curves from the test results,the rationality and reliability of the finite element model has been confirmed,moreover,the change of the section stiffness and stress in the forcing process and the ultimate bearing capacity of the column were analyzed.Based on the model,the comparison of ultimate bearing capacity and ductility between CFLRST column and reinforced concrete(RC)column were also analyzed.The results of the finite element analysis show that the loading process of CFLRST column consists of elastic stage,yield stage and failure stage.The failure modes are mainly strength failure and failure of elastoplastic instability.CFLRST column has higher bearing capacities in comparison with reinforced concrete columns with the same steel ratio.In addition,the stiffness degeneration of CFLRST column is slower than RC column and CFLRST column has good ductility. 展开更多
关键词 steel-concrete composite structure concrete-filled lattice rectangular steel tube column nonlinear finite element ultimate strength DUCTILITY
下载PDF
A new calculation method for axial load capacity of separated concrete-filled steel tubes based on limit equilibrium theory
10
作者 刘夏平 孙卓 +2 位作者 唐述 黄海云 刘爱荣 《Journal of Central South University》 SCIE EI CAS 2013年第6期1750-1758,共9页
A new calculation method for axial load capacity of separated concrete-filled steel tubes based on limit equilibrium theory was proposed,which took into account the decrease of confinement effect by steel tube and the... A new calculation method for axial load capacity of separated concrete-filled steel tubes based on limit equilibrium theory was proposed,which took into account the decrease of confinement effect by steel tube and the non-uniform distribution of ultimate stress in cored concrete.The accuracy of the analytical result is validated through running the numerical result by finite element method (FEM) and experimental data as well.The influences of the key parameters on the load capacity of the concrete-filled steel tube (CFST) was studied,including the separation ratio,concrete compressive strength,and steel strength.The results indicate that the load capacity of the tube increases with concrete strength and steel strength under the separation ratio less than 4%,while decreases with a higher separation ratio improved. 展开更多
关键词 concrete-filled steel tube limit equilibrium theory axial load capacity
下载PDF
Experimental study on centrifugal concrete-filled steel tubes under bending and torsion
11
作者 金伟良 曲晨 于戈 《Journal of Zhejiang University Science》 EI CSCD 2003年第5期565-572,共8页
A real-size experiment on 11 tubes was done to study the performance o f centrifugal concrete-filled steel tubes under bending and torsion. This pape r first introduces the relevant operating method,equipment,subjects... A real-size experiment on 11 tubes was done to study the performance o f centrifugal concrete-filled steel tubes under bending and torsion. This pape r first introduces the relevant operating method,equipment,subjects and process es. The factors that affect deformation and stiffness and the break mechanism un der different loading were studied. Experimental stress analysis showed that the values of practical critical stress of steel tubes accorded well with the MISES Yielding Rule. The correlative equation (on the bearing capacity of a structura l member under bending and torsion) deduced in this study may provide valuable reference for the design of this structural member. 展开更多
关键词 Centrifugal concrete-filled steel tube Bending an d torsion Stiffness DISTORTION Bearing capacity
下载PDF
Prediction of Axial Capacity of Concrete-Filled Square Steel Tubes Using Neural Networks
12
作者 朱美春 王清湘 冯秀峰 《Journal of Southwest Jiaotong University(English Edition)》 2005年第2期151-155,共5页
The application of artificial neural network to predict the ultimate bearing capacity of CFST ( concrete-filled square steel tubes) short columns under axial loading is explored. Input parameters consiste of concret... The application of artificial neural network to predict the ultimate bearing capacity of CFST ( concrete-filled square steel tubes) short columns under axial loading is explored. Input parameters consiste of concrete compressive strength, yield strength of steel tube, confinement index, sectional dimension and width-to-thickness ratio. The ultimate bearing capacity is the only output parameter. A multilayer feedforward neural network is used to describe the nonlinear relationships between the input and output variables. Fifty-five experimental data of CFST short columns under axial loading are used to train and test the neural network. A comparison between the neural network model and three parameter models shows that the neural network model possesses good accuracy and could be a practical method for predicting the ultimate strength of axially loaded CFST short columns. 展开更多
关键词 concrete-filled square steel tubes Neural networks Axial capacity Short columns
下载PDF
Axial Bearing Capacity of Short FRP Confined Concrete-filled Steel Tubular Columns 被引量:7
13
作者 刘兰 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2010年第3期454-458,共5页
The bearing capacity of FRP confined concrete-filled steel tubular (FRP-CFST) columns under axial compression was investigated. This new type of composite column is a concrete-filled steel tube (CFST) confined wit... The bearing capacity of FRP confined concrete-filled steel tubular (FRP-CFST) columns under axial compression was investigated. This new type of composite column is a concrete-filled steel tube (CFST) confined with fiber-reinforced polymer (FRP) wraps. Totally 11 short column specimens were tested to failure under axial compression. The influences of the type and quantity of FRP, the thickness of steel tube and the concrete strength were studied. It was found that the bearing capacity of short FRP-CFST column was much higher than that of comparable CFST column. Furthermore, the formulas for calculating the bearing capacity of the FRP-CFST columns are proposed. The analytical calculated results agree well with the experimental results. 展开更多
关键词 COLUMNS concrete-filled steel tubes (CFST) fiber reinforced polymer (FRP) CONFINEMENT bearing capacity.
原文传递
Seismic behavior of concrete filled steel tubular arch structures 被引量:4
14
作者 熊峰 Sashi K Kunnath 刘浩吾 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2005年第1期107-115,共9页
Shaking table tests of a 1:10 scale arch model performed to investigate the seismic behavior and resistance of concrete filled steel tubular (CFT) arch structures are described in this paper. The El-Centro record and ... Shaking table tests of a 1:10 scale arch model performed to investigate the seismic behavior and resistance of concrete filled steel tubular (CFT) arch structures are described in this paper. The El-Centro record and Shanghai artificial wave were adopted as the input excitation. The entire test process can be divided into three stages depending on the lateral brace configurations, i.e., fully (five) braced, two braces removed, and all braces removed. A total of 46 tests, starting from the elastic state to failure condition, have been conducted. The natural vibration frequencies, responses of acceleration, displacement and strain were measured. From the test results, it is demonstrated that the CFT arch structures are capable of resisting severe ground motions and that CFT arches offer a credible alternative to reinforced concrete arches, especially in regions of high seismic intensity. 展开更多
关键词 concrete filled steel tube arch structures shaking table test seismic behavior lateral braces
下载PDF
Natural Vibration Characteristics for Prestressed Concrete-Filled Rectangular Steel Tube Simply Supported Beam
15
作者 YE Junxian HUANG Weixuan LI Siping 《Journal of Shanghai Jiaotong university(Science)》 EI 2024年第5期940-944,共5页
The dynamic control equation of a new prestressed partially concrete-filled rectangular steel tube(CFRT)beam can be derived based on D’Alembert’s principle.It is used to infer the theoretical results of the dynamic ... The dynamic control equation of a new prestressed partially concrete-filled rectangular steel tube(CFRT)beam can be derived based on D’Alembert’s principle.It is used to infer the theoretical results of the dynamic characteristics for the prestressed CFRT beam.Additionally,the finite element model is set up by ABAQUS for simulation analysis.The results show that the natural vibration frequencies and mode function of the prestressed CFRT simply supported beam calculated by the theoretical formulas are reliable since the relative errors of the first-order frequencies under different prestressing levels are within 6%compared with the finite element results.Further analysis of the prestressing parameters is carried out using the theoretical formulas,in which factors such as the prestressing level,eccentricity of tendons,and tensile stiffness of prestressed tendons have different influences on the natural vibration frequencies.Finally,it provides a theoretical basis for the dynamic design of the prestressed CFRT beams. 展开更多
关键词 PRESTRESS concrete-filled rectangular steel tube(CFRT) VIBRATION finite element analysis
原文传递
Behavior of High Strength Concrete Filled Square Steel Tube Stub Columns with Inner CFRP Tube Under Biaxial Eccentric Compression 被引量:1
16
作者 Zhijian Yang Guochang Li +1 位作者 Yan Lang Zengmei Qiu 《Computer Modeling in Engineering & Sciences》 SCIE EI 2021年第4期273-290,共18页
This paper studies the contribution of CFRP(carbon fiber-reinforced polymer)to the mechanical behavior of high strength concrete-filled square steel tube(HCFST)under biaxial eccentric compression.The new type of compo... This paper studies the contribution of CFRP(carbon fiber-reinforced polymer)to the mechanical behavior of high strength concrete-filled square steel tube(HCFST)under biaxial eccentric compression.The new type of composite member is composed of an inner CFRP tube and an outer steel tube with concrete filled in the two tubes.The finite element analysis was made by ABAQUS on the behavior of high strength concrete filled square steel tubular columns with inner CFRP circular tube subjected to bi-axial eccentric loading.The results obtained from the finite element analysis were verified with the experimental results.In addition,the load-deflection curves in the whole process were calculated and analyzed,which can be divided into three segments:Elastic phase,plastic phase,descending phase.Based on the load-deflection curves,the stresses analysis on the core concrete,CFRP tube and steel tube were conducted.The confinement effect of the CFRP tube improves the ductility of HCFST-CFRP stub column.CFRP ratio and eccentricity affect the ultimate bearing capacity of HCFST stub column.Finally,a calculation formula of ultimate bearing capacity was proposed in the paper. 展开更多
关键词 CFRP tube concrete-filled square steel tube high strength concrete bi-axial bending stub column
下载PDF
Expansive Performance of Self-stressing and Self-compacting Concrete Confined with Steel Tube
17
作者 徐磊 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2007年第2期341-345,共5页
Combining with the technology of self-compacting concrete, self-stressing concrete and concrete-filled steel tube, we can get self-compacting and self-stressing concrete-filled steel tube. In order to study the expans... Combining with the technology of self-compacting concrete, self-stressing concrete and concrete-filled steel tube, we can get self-compacting and self-stressing concrete-filled steel tube. In order to study the expansive mechanism of self-stressing concrete, the continuous observation of 47 days on six specimens was carried on. The specimens have different steel area to concrete area ratio. The expansive process in hoop and axial direction were studied, and the expansive mechanism was discussed too. The experimental results identify that the creep and elastic deformation take a large proportion in effective free expansion. The calculating formulas of self-stress in hoop and axial directions were presented here. 展开更多
关键词 self-compacting concrete self-stressing concrete concrete-filled steel tube restrained ex- pansion free expansion CREEP
下载PDF
乌兹别克斯坦9度区某超高层建筑结构设计与优化 被引量:1
18
作者 闫锋 花炳灿 安东亚 《建筑结构》 北大核心 2024年第13期51-56,共6页
对于9度设防地区的超高层建筑,其结构设计基本由地震作用控制,因此抗震设计尤为重要。建筑消能减震技术可在提高结构地震安全储备的同时,降低整体工程造价,是结构优化设计的有效措施。对位于9度区的超高层建筑进行了结构方案选型对比、... 对于9度设防地区的超高层建筑,其结构设计基本由地震作用控制,因此抗震设计尤为重要。建筑消能减震技术可在提高结构地震安全储备的同时,降低整体工程造价,是结构优化设计的有效措施。对位于9度区的超高层建筑进行了结构方案选型对比、结构方案优化、减震设计方案比选、剪力墙内嵌钢板优化。结果显示,钢骨混凝土框架⁃核心筒方案相对于钢框架⁃支撑方案具备更高的成本优势;框架⁃核心筒方案可通过精细化设计作进一步优化;在此基础上,对钢骨混凝土框架⁃核心筒方案采用两种消能减震方案进行比选,结果表明,采用黏滞阻尼器方案的结构抗震性能明显优于采用黏滞阻尼墙方案;最后通过增大剪力墙竖向分布钢筋配筋率,对低区核心筒墙肢中的内嵌钢板进行了优化。 展开更多
关键词 9度抗震设防 超高层建筑 钢骨混凝土结构 框架⁃核心筒 消能减震
下载PDF
设有叠合柱的局部错层RC框架结构地震易损性分析 被引量:1
19
作者 张淑云 刘建波 +2 位作者 代慧娟 王乐 高欣悦 《中国科技论文》 CAS 2024年第3期275-283,共9页
为研究某一设有叠合柱的局部错层钢筋混凝土(reinforced concrete,RC)框架结构在近断层和远场地震作用下的破坏概率,自定义钢管混凝土叠合柱塑性铰参数,并与试验对比验证塑性铰参数的有效性。采用SAP2000建立非线性分析模型,选取近断层... 为研究某一设有叠合柱的局部错层钢筋混凝土(reinforced concrete,RC)框架结构在近断层和远场地震作用下的破坏概率,自定义钢管混凝土叠合柱塑性铰参数,并与试验对比验证塑性铰参数的有效性。采用SAP2000建立非线性分析模型,选取近断层和远场地震波共22条,分别以地震峰值加速度(peak ground acceleration,PGA)和最大层间位移角作为地震动强度指标和结构性能指标,基于增量动力分析(incremental dynamic analysis,IDA)结果和点估计函数对错层框架结构进行易损性分析。结果表明:对于远场地震动,结构满足“三水准”抗震设防要求,在罕遇地震下超越防止倒塌极限状态的概率仅为0.24%;结构在近断层多遇地震下仍能满足“小震不坏”的设计要求,设防地震下结构超越修复后使用极限状态的概率为53.63%,发生中等破坏的概率较大,罕遇地震下结构达到倒塌极限状态的概率为5.37%,较远场地震作用破坏更为严重。研究结果可为错层框架结构的设计和地震风险评估提供参考。 展开更多
关键词 近断层地震 错层框架结构 钢管混凝土叠合柱 增量动力分析 点估计
下载PDF
PBL抗剪传力钢筋连接接头受拉力学性能试验
20
作者 龚超 梁梓豪 +4 位作者 张素梅 李孝忠 梁伟桥 闫贵海 姚志东 《哈尔滨工程大学学报》 EI CAS CSCD 北大核心 2024年第7期1391-1399,共9页
装配式混凝土构件间钢筋的连接是其适用性和经济性的关键环节,针对国内工程常用的灌浆套筒和约束浆锚钢筋连接技术存在施工难度大、效率低、质量不易检验等问题,本文提出了PBL-穿孔钢筋连接接头、PBL-穿孔钢管连接接头和PBL-U形钢筋连... 装配式混凝土构件间钢筋的连接是其适用性和经济性的关键环节,针对国内工程常用的灌浆套筒和约束浆锚钢筋连接技术存在施工难度大、效率低、质量不易检验等问题,本文提出了PBL-穿孔钢筋连接接头、PBL-穿孔钢管连接接头和PBL-U形钢筋连接接头3种钢筋连接接头,实现预制混凝土单元间钢筋应力的传递,具有施工简便、质量易保证、成本低等优势。对这3种钢筋接头进行了6组参数共18个钢筋接头试件的拉伸性能试验,研究了新型接头试件的破坏模式、承载力和变形能力等,得到各参数对新型接头拉伸强度的影响规律,并对不同接头的受拉力学性能进行对比分析。研究结果表明:3种钢筋连接接头能够实现钢筋应力的有效传递,验证了新型钢筋连接接头的可行性。 展开更多
关键词 装配式混凝土 钢筋连接接头 PBL剪力键 钢管混凝土 拉伸试验 裂缝发展 破坏模式 受拉承载力
下载PDF
上一页 1 2 58 下一页 到第
使用帮助 返回顶部