期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
Types of focal mechanism solutions and parameter consistency of the sub-blocks in Sichuan and Yunnan Provinces
1
作者 程万正 阮祥 张永久 《Acta Seismologica Sinica(English Edition)》 EI CSCD 2006年第6期605-619,共15页
Based on P- and S-wave amplitudes and some clear initial P-wave motion data, we calculated focal mechanism solutions of 928 M≥2.5 earthquakes (1994-2005) in four sub-blocks of Sichuan and Yunnan Provinces, namely S... Based on P- and S-wave amplitudes and some clear initial P-wave motion data, we calculated focal mechanism solutions of 928 M≥2.5 earthquakes (1994-2005) in four sub-blocks of Sichuan and Yunnan Provinces, namely Sichuan-Qinghai, Yajiang, Central Sichuan and Central Yunnan blocks. Combining these calculation results with those of the focal mechanism solutions of moderately strong earthquakes, we analyzed the stress field characteristics and dislocation types of seismogenic faults that are distributed in the four sub-blocks. The orientation of principal compressive stress for each block is: EW in Sichuan-Qinghai, ESE or SE in Yajiang, Central Sichuan and Central Yunnan blocks. Based on a great deal of focal mechanism data, we designed a program and calculated the directions of the principal stress tensors, σ1, σ2 and σ3, for the four blocks. Meanwhile, we estimated the difference (also referred to as consistency parameter θ^- ) between the force axis direction of focal mechanism solution and the direction of the mean stress tensor of each block. Then we further analyzed the variation of θ^- versus time and the dislocation types of seismogenic faults. Through determination of focal mechanism solutions for each block, we present information on the variation in θ^- value and dislocation types of seismogenic faults. 展开更多
关键词 focal mechanism solution dynamic stress field dislocation type of earthquake source consistency parameter Sichuan-Yunnan block
下载PDF
Temporal evolution of the focal mechanism consistency of the 2021 Yangbi M_(S) 6.4 earthquake sequence in Yunnan 被引量:2
2
作者 Xiaobin Li Mingpei Jin +3 位作者 Ya Huang Wenjian Cha Jun Wang Sihai Li 《Earthquake Research Advances》 CSCD 2022年第2期11-20,共10页
Using the Cut And Paste(CAP)method,we invert the focal mechanism of 38 moderate earthquakes(M_(S)≥3.0)recorded by Yunnan seismic network and analyze the corresponding focal mechanism consistency based on the minimum ... Using the Cut And Paste(CAP)method,we invert the focal mechanism of 38 moderate earthquakes(M_(S)≥3.0)recorded by Yunnan seismic network and analyze the corresponding focal mechanism consistency based on the minimum spatial rotation angle.Our results indicate that the M_(S)6.4 mainshock is induced by a lateral strike slip fault(with a rake angle of~-165°)and a little normal-faulting component event along a nearly vertical plane(dipping angle~79° and strike~138°).Combining our results with high resolution catalog,we argue that the seismogenic fault of this earthquake sequence is a secondary fault western to the major Weixi-Qiaohou-Weishan fault.The focal mechanism evolution can be divided into three periods.During the first period,the foreshock sequence,the focal mechanism consistency is the highest(KA<36°);during the second period which is shortly after the mainshock,the focal mechanism shows strong variation with KA ranging from 8° to 110°;during the third period,the seismicity becomes weak and the focal mechanism of the earthquakes becomes more consistent than the second period(18°<KA<73°).We suggest that the KA,to some extent,represents the coherence between local tectonic stress regime and the stress state of each individual earthquake.Furthermore,high focal mechanism consistency and high linearity of seismic distribution may serve as indicators for the identification of foreshock sequence. 展开更多
关键词 Cut and Paste Focal mechanism solution consistency parameters Aftershock spreading Seismogenic fault Earthquake trend The Yangbi M_(S)6.4 earthquake in 2021
下载PDF
PARAMETER ESTIMATION IN LINEAR REGRESSION MODELS FOR LONGITUDINAL CONTAMINATED DATA 被引量:1
3
作者 QianWeimin LiYumei 《Applied Mathematics(A Journal of Chinese Universities)》 SCIE CSCD 2005年第1期64-74,共11页
The parameter estimation and the coefficient of contamination for the regression models with repeated measures are studied when its response variables are contaminated by another random variable sequence.Under the sui... The parameter estimation and the coefficient of contamination for the regression models with repeated measures are studied when its response variables are contaminated by another random variable sequence.Under the suitable conditions it is proved that the estimators which are established in the paper are strongly consistent estimators. 展开更多
关键词 longitudinal data coeffcient of contamination parameter estimation strong consistency.
下载PDF
Study on the Recent Tectonic Stress Field in the “Huoshan Seismic Window” Region 被引量:1
4
作者 Ni Hongyu Liu Zemin +3 位作者 Hong Dequan Li Lingli Zheng Xianjin Xu Xin 《Earthquake Research in China》 2013年第4期467-478,共12页
The focal mechanisms of 62 moderate-small earthquakes since 1980 in the " Huoshan seismic window" region are calculated with the method developed recently by Snoke, combining the use of the first motion of P, SV and... The focal mechanisms of 62 moderate-small earthquakes since 1980 in the " Huoshan seismic window" region are calculated with the method developed recently by Snoke, combining the use of the first motion of P, SV and SH waves with their amplitude ratios. Based on these abundant focal mechanisms, the mean tectonic stress field in the "Huoshan seismic window" region is inverted with the average stress tensor method, and the result shows that the "Huoshan seismic window" region is horizontally compressed in the near EW direction and horizontally dilated in the near NS direction, which is in accord with statistical results of focal mechanism parameters. We estimate the difference (also referred to as consistency parameter 0) between the force axis direction of the focal mechanism solution and the mean stress tensor, then further analyze the variation characteristics of 0 versus time, and the relationship with moderately strong earthquakes in the east China region. The result indicates that 0 in the " Huoshan seismic window" region is in good correspondence with moderately strong earthquakes in the East China region. When 0 is lower than the mean value, corresponding moderately strong earthquakes may occur in the East China region. 展开更多
关键词 Focal mechanism solutions consistency parameter Tectonic stress field The"Huoshan seismic window" East China region
下载PDF
Characteristics of focal mechanisms in Chile subduction
5
作者 Wang Xiaoshan Diao Guiling +1 位作者 Feng Xiangdong Yang Yaqiong 《Geodesy and Geodynamics》 2012年第3期23-28,共6页
We use the Centroid Moment Tensor (CMT) solution of the earthquakes occurred in Chile subduction to analyze the characteristics of focal mechanisms. We define the,angle between P, B, and T axes of focal mechanisms a... We use the Centroid Moment Tensor (CMT) solution of the earthquakes occurred in Chile subduction to analyze the characteristics of focal mechanisms. We define the,angle between P, B, and T axes of focal mechanisms and three stress axes of tectonic stress field as the consistency parameter, to research the dynamic changes of focal mechanism pattern in earthquake preparation area before the 2010 Maule, Chile earthquake. The result shows that the consistency parameter decreases before the earthquake, and the area of the lower consistent parameter visually coincides with the distribution of aftershocks. This phenomenon is similar to the Load-Unload Response Ratio (LURR) decreases prior to the occurrence of macro-fracture happened in the acoustic emission experiments involving large rock specimens under tri-axial stress. 展开更多
关键词 2010 Maule earthquake Centroid Moment Tensor (CMT) solutions consistency parameter Chile subduction Load-Unload Response Ratio (LURR)
原文传递
Difference between focal mechanisms of Dayao earthquake doublet sequence 被引量:1
6
作者 Xiaoshan Wang Xiangdong Feng +2 位作者 Guiling Diao Libing Wang Lingling Cai 《Earthquake Science》 CSCD 2009年第6期667-673,共7页
Using the maximum amplitude ratios of vertical component of P and S waves recorded by a regional network, 921 focal mechanisms of Dayao earthquake doublet sequence are determined by means of synthetic seismograms of a... Using the maximum amplitude ratios of vertical component of P and S waves recorded by a regional network, 921 focal mechanisms of Dayao earthquake doublet sequence are determined by means of synthetic seismograms of a point source of dislocation in a plane layered medium. Among them, 389 focal mechanisms are in the aftershock sequence of M6.2 earthquake occurred on 21 July, 2003 and the other 532 focal mechanisms are in the aftershock sequence of M6.1 earthquake occurred on 16 October, 2003 in Dayao, Yurman. The focal mechanism consistent parameter a of the two aftershock sequences are calculated and analyzed. According to the focal mechanism consistent parameter a, the focal mechanisms of the first aftershock sequence are more consistent than those of the second. According to the comparison of CMT solutions of the two M6 earthquakes, the physical mechanism of the doublet in the intra-plate earthquake is very complex, and many processes are involved and interacted with each other. This doublet provides insights into earthquake clustering, triggering and stress cycling. 展开更多
关键词 focal mechanism consistent parameter a Dayao earthquake doublet DIFFERENCE
下载PDF
Consistent CMT solutions from Harvard University before great earthquakes in Kurile Islands and its significance for earthquake prediction
7
作者 王俊国 刁桂苓 《Acta Seismologica Sinica(English Edition)》 EI CSCD 2005年第2期189-195,共7页
In the paper, we use the Central Moment Tensor (CMT) solution acquired by Harvard Univ. for the earthquakes occurred in Kurile Islands to analyze the consistent focal mechanism in the area and propose the idea of maki... In the paper, we use the Central Moment Tensor (CMT) solution acquired by Harvard Univ. for the earthquakes occurred in Kurile Islands to analyze the consistent focal mechanism in the area and propose the idea of making earthquake prediction based on the consistent parameter a of focal mechanism and stress field. The results from the study indicate that before Mw greater than or equal 7.5 earthquakes, the consistent parameter a decreases, which starts about 10-110 days and ends about 30-2 days before the great earthquakes. Although the phenomenon is not totally the same for individual earthquake, the difference is not large. Certainly, the phenomenon should be tested by time for its reliability. However, it should not be random that the focal mechanism of Mw greater than or equal 5.3 earthquakes are consistent successively with the stress field in an area of several hundreds kilometers in length. It should be a phenomenon of predictive significance. When the accumulated earthquake examples are sufficient, uniform judgment criteria and prediction principles can be stipulated then. 展开更多
关键词 Kurile Islands area CMT solution consistent parameter predictive significance
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部