A procedure for design of hydrogen networks with multiple contaminants 被引量:1
1
作者 王雪飞 王喆 +1 位作者 赵慧鹏 刘智勇 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2015年第9期1536-1541,共6页
It is necessary to reduce hydrogen consumption to meet increasingly strict environmental and product-quality regulations for refinery plants. In this paper, the concentration potential concepts proposed for design of ... It is necessary to reduce hydrogen consumption to meet increasingly strict environmental and product-quality regulations for refinery plants. In this paper, the concentration potential concepts proposed for design of water-using networks are extended to synthesis of hydrogen networks with multiple contaminants. In the design procedure, the precedence of processes is determined by the values of concentration potential of demands.The usage of complementary source pair(s) to reduce utility consumption is investigated. Three case studies are presented to illustrate the effectiveness of the method. It is shown that the design procedure has clear engineering meaning. 展开更多
关键词 Multiple contaminants Hydrogen network concentration potentials Complementary sources
下载PDF
Simulation of Electric Field Distribution along Insulator Surface in Polluted Environments
2
作者 Yukun Lv Yuechi Wang +2 位作者 Jiawen Wang Jing Wang Jiaxi Yang 《Energy Engineering》 EI 2021年第3期631-642,共12页
In recent years,more than 50%of the cities in the inland area of our country have suffered from moderate pollution.It can affect the distribution of electric field along the surface of insulator and the pollution char... In recent years,more than 50%of the cities in the inland area of our country have suffered from moderate pollution.It can affect the distribution of electric field along the surface of insulator and the pollution characteristics of its surface area,even endanger the safe operation of transmission lines.This paper takes the XSP-160 porcelain three umbrella insulator under the action of 0–±30 kV DC voltage as the research object,and establishes the physical model of the insulator;uses COMSOL software to simulate the electric field of the insulator.The comparison with the results of the wind tunnel test of North China Electric Power University verifies the rationality of the simulation method.In view of the medium pollution environment which often occurs in the inland area,the force of the polluted particles deposited on the insulator under 110 kV DC voltage was analyzed.The distribution characteristics of the electric field along the surface in the clean and three kinds of pollution environment(light,medium and heavy)were simulated and compared.The results showed that:1)In the moderate pollution environment,the influence of fluid drag force on the movement of polluted particles is greater at the initial stage(0.28–0.33 s);at the late stage(after 0.33 s),the influence of the electric field force begins to increase,and gradually plays a major role in the process of fouling.2)In the three different polluted environments,the potential along the surface of each umbrella skirt of the insulator increases non-linearly with the increasing of the pollution concentration,and there are apparent potential inflection points near b and l.3)The pollution particle concentration has the most obvious influence on the electric field along the low-voltage umbrella skirt,whose potential distortion rate can be up to 220 times in the heavy polluted environment. 展开更多
关键词 Porcelain three umbrella insulator surface potential distortion rate contamination concentration
下载PDF
Erosion degradation characteristics of a linear electro-hydrostatic actuator under a high-frequency turbulent flow field 被引量:2
3
作者 Yuan LI Shaoping WANG +1 位作者 Mileta M.TOMOVIC Chao ZHANG 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2018年第5期914-926,共13页
The paper proposes a performance degradation analysis model based on dynamic erosion wear for a novel Linear Electro-Hydrostatic Actuator(LEHA). Rather than the traditional statistical methods based on degradation d... The paper proposes a performance degradation analysis model based on dynamic erosion wear for a novel Linear Electro-Hydrostatic Actuator(LEHA). Rather than the traditional statistical methods based on degradation data, the method proposed in this paper firstly analyzes the dominant progressive failure mode of the LEHA based on the working principle and working conditions of the LEHA. The Computational Fluid Dynamics(CFD) method, combining the turbulent theory and the micro erosion principle, is used to establish an erosion model of the rectification mechanism. The erosion rates for different port openings, under a time-varying flow field, are obtained. The piecewise linearization method is applied to update the concentration of contaminated particles within the LEHA, in order to gain insight into the erosion degradation process at various stages of degradation. The main contribution of the proposed model is the application of the dynamic concentration of contamination particles in erosion analysis of Electro-Hydraulic Servo Valves(EHSVs), throttle valves, spool valves, and needle valves. The effects of system parameters and working conditions on component wear are analyzed by simulations. The results of the proposed model match the expected degradation process. 展开更多