期刊文献+
共找到104,906篇文章
< 1 2 250 >
每页显示 20 50 100
Traction power systems for electrified railways:evolution,state of the art,and future trends
1
作者 Haitao Hu Yunjiang Liu +4 位作者 Yong Li Zhengyou He Shibin Gao Xiaojuan Zhu Haidong Tao 《Railway Engineering Science》 EI 2024年第1期1-19,共19页
Traction power systems(TPSs)play a vital role in the operation of electrified railways.The transformation of conventional railway TPSs to novel structures is not only a trend to promote the development of electrified ... Traction power systems(TPSs)play a vital role in the operation of electrified railways.The transformation of conventional railway TPSs to novel structures is not only a trend to promote the development of electrified railways toward high-efficiency and resilience but also an inevitable requirement to achieve carbon neutrality target.On the basis of sorting out the power supply structures of conventional AC and DC modes,this paper first reviews the characteristics of the existing TPSs,such as weak power supply flexibility and low-energy efficiency.Furthermore,the power supply structures of various TPSs for future electrified railways are described in detail,which satisfy longer distance,low-carbon,high-efficiency,high-reliability and high-quality power supply requirements.Meanwhile,the application prospects of different traction modes are discussed from both technical and economic aspects.Eventually,this paper introduces the research progress of mixed-system electrified railways and traction power supply technologies without catenary system,speculates on the future development trends and challenges of TPSs and predicts that TPSs will be based on the continuous power supply mode,employing power electronic equipment and intelligent information technology to construct a railway comprehensive energy system with renewable energy. 展开更多
关键词 Railway traction power system Future electrified railway Flexible continuous power supply Renewable energy Integrated energy system
下载PDF
Laparoscopic Orchidopexy after 4 Weeks of Testicular Traction with Preservation of Blood Supply: A New Concept for the Treatment of Intra-Abdominal Cryptorchidism: Original Article
2
作者 Ntsobe Tobie Eric Haijin Liu +5 位作者 Nyanit Bob Dorcas Wei Peng Feng Chen Ndikontar Raymond Kouna Tsala Irene Nadine Qian Liu 《Open Journal of Pediatrics》 2024年第2期205-217,共13页
Background: Testicular atrophy is recurrent after orchidopexy for intra-abdominal cryptorchidism due to damage to vessels. Fowlers-Stephens and Shehata methods proposed staged orchidopexy, but are still associated to ... Background: Testicular atrophy is recurrent after orchidopexy for intra-abdominal cryptorchidism due to damage to vessels. Fowlers-Stephens and Shehata methods proposed staged orchidopexy, but are still associated to a rate of atrophy greater than 10%. Purpose: We set out to present a new technique that preserves testicular vessels. Our study is aimed at investigating testicular vitality after surgery. Patients and Method: We reviewed files of boys who underwent orchidopexy for 2 years in our department. Those who have been operated for intra-abdominal cryptorchidism with the new technique and aged between 6 months and 14 years old were included in our study. We excluded boys who have been operated before 6 months and after 14 years old and those who did not respect their follow-up plane. Ultrasound (US) outcomes were used to measure testicular volumes and blood flow at each postoperative visit. The Sample population was divided into group A and group B representing testes that were followed respectively for 12 and 24 months. Results: 22 boys with 25 testes were included in our study;11 testes in group A and 14 testes in group B. In each group, we noted a significant difference of UDT volumes from the third month after surgery with respective P-values 0.05. There was no statistical difference between UDT and contra lateral testes volumes 12 months after surgery in group A and 24 months in group B with respective P-values of 0.07 and 0.72. All volume differential indexes were Conclusion: This method offers a new perspective in performing safe orchidopexy for intra abdominal undescended testes. 展开更多
关键词 LAPAROSCOPY Staged-Orchidopexy Testicar traction Testicular Atrophy
下载PDF
Comparative Analysis of Continuous versus Intermittent Proton Pump Inhibitor Therapy in Patients with Upper Gastrointestinal Bleeding Due to Ulcers
3
作者 Abraamyan Feruza Misra P. Neeladri 《Open Journal of Gastroenterology》 CAS 2024年第3期99-107,共9页
Upper gastrointestinal bleeding (UGIB) presents as a prevalent clinical challenge, with annual incidence rates ranging from 80 to 150 cases per 100,000 individuals. Guidelines for managing patients with UGIB due to bl... Upper gastrointestinal bleeding (UGIB) presents as a prevalent clinical challenge, with annual incidence rates ranging from 80 to 150 cases per 100,000 individuals. Guidelines for managing patients with UGIB due to bleeding ulcers recommend a continuous infusion of proton pump inhibitors (PPI). However, studies comparing intermittent dosing of PPI therapy show that this regimen achieves similar clinical benefits. If the clinical efficacy remains equivalent, intermittent dosing will be more cost-effective for patients and the health care system. Our research study aims to analyze the comparative effectiveness of intermittent versus continuous PPI therapy after endoscopic treatment in patients with UGIB, focusing on such endpoints as rebleeding risk at 3-and 7-day mortality rates. Methods: Resources searched included MEDLINE, EMBASE, PUBMED, and the Cochrane Central Register of Controlled Trials databases from January 2010 through December 2023 with the inclusion of meta-analysis, systematic review, review, or ACG guideline recommendations. Results of the analysis show how recommendations regarding high vs. low PPI regimen changed over time: from no difference in regimen in 2010 to recommending continuous regimen in 2012 to declaring insufficient evidence between choosing one regimen over another in 2013 to determine that both regimens were comparable to each other in 2014-2018 and finally to recommending both regimens in 2021. To conclude, our review shows that in patients with bleeding ulcers and high-risk endoscopic findings, intermittent PPI therapy is non-inferior to continuous PPI infusion for three days, seven days bleeding risk or mortality rates;however, it remains challenging to determine the most optimal intermittent regimen due to heterogeneity of RCTs included in meta-analyses, and further trials will need to be performed. 展开更多
关键词 Upper Gastrointestinal Bleeding PPI continuous INTERMITTENT BOLUS REGIMENS Review
下载PDF
Enhanced measurement precision with continuous interrogation during dynamical decoupling
4
作者 张军 杜鹏 +3 位作者 敬雷 徐鹏 尤力 张文献 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第3期88-94,共7页
Dynamical decoupling(DD)is normally ineffective when applied to DC measurement.In its straightforward implementation,DD nulls out DC signal as well while suppressing noise.This work proposes a phase relay method that ... Dynamical decoupling(DD)is normally ineffective when applied to DC measurement.In its straightforward implementation,DD nulls out DC signal as well while suppressing noise.This work proposes a phase relay method that is capable of continuously interrogating the DC signal over many DD cycles.We illustrate its efficacy when applied to the measurement of a weak DC magnetic field with an atomic spinor Bose-Einstein condensate.Sensitivities approaching standard quantum limit or Heisenberg limit are potentially realizable for a coherent spin state or a squeezed spin state of 10000 atoms,respectively,while ambient laboratory level noise is suppressed by DD.Our work offers a practical approach to mitigate the limitations of DD to DC measurement and would find other applications for resorting coherence in quantum sensing and quantum information processing research. 展开更多
关键词 quantum sensing continuous interrogation quantum magnetometer dynamical decoupling Heisenberg limit
原文传递
THE ABSENCE OF SINGULAR CONTINUOUS SPECTRUM FOR PERTURBED JACOBI OPERATORS
5
作者 傅钲淇 黎雄 《Acta Mathematica Scientia》 SCIE CSCD 2024年第2期515-531,共17页
This paper is mainly about the spectral properties of a class of Jacobi operators(H_(c,b)u)(n)=c_(n)u(n+1)+c_(n-1)u(n-1)+b_(n)u(n),.where∣c_(n)−1∣=O(n^(−α))and b_(n)=O(n^(−1)).We will show that,forα≥1,the singula... This paper is mainly about the spectral properties of a class of Jacobi operators(H_(c,b)u)(n)=c_(n)u(n+1)+c_(n-1)u(n-1)+b_(n)u(n),.where∣c_(n)−1∣=O(n^(−α))and b_(n)=O(n^(−1)).We will show that,forα≥1,the singular continuous spectrum of the operator is empty. 展开更多
关键词 Jacobi operator singular continuous spectrum Prüfer variables
下载PDF
Microarrow sensor array with enhanced skin adhesion for transdermal continuous monitoring of glucose and reactive oxygen species
6
作者 Xinshuo Huang Baoming Liang +9 位作者 Shantao Zheng Feifei Wu Mengyi He Shuang Huang Jingbo Yang Qiangqiang Ouyang Fanmao Liu Jing Liu Hui-jiuan Chen Xi Xie 《Bio-Design and Manufacturing》 SCIE EI CAS CSCD 2024年第1期14-30,共17页
Conventional blood sampling for glucose detection is prone to cause pain and fails to continuously record glucose fluctuations in vivo.Continuous glucose monitoring based on implantable electrodes could induce pain an... Conventional blood sampling for glucose detection is prone to cause pain and fails to continuously record glucose fluctuations in vivo.Continuous glucose monitoring based on implantable electrodes could induce pain and potential tissue inflammation,and the presence of reactive oxygen species(ROS)due to inflammationmay affect glucose detection.Microneedle technology is less invasive,yet microneedle adhesion with skin tissue is limited.In this work,we developed a microarrow sensor array(MASA),which provided enhanced skin surface adhesion and enabled simultaneous detection of glucose and H_(2)O_(2)(representative of ROS)in interstitial fluid in vivo.The microarrows fabricated via laser micromachining were modified with functional coating and integrated into a patch of a three-dimensional(3D)microneedle array.Due to the arrow tip mechanically interlocking with the tissue,the microarrow array could better adhere to the skin surface after penetration into skin.The MASA was demonstrated to provide continuous in vivo monitoring of glucose and H_(2)O_(2) concentrations,with the detection of H_(2)O_(2) providing a valuable reference for assessing the inflammation state.Finally,the MASA was integrated into a monitoring system using custom circuitry.This work provides a promising tool for the stable and reliable monitoring of blood glucose in diabetic patients. 展开更多
关键词 Microarrow sensor array Glucose sensing Reactive oxygen species sensing Integrated system continuous monitoring
下载PDF
Existence of a Hölder Continuous Extension on Embedded Balls of the 3-Torus for the Periodic Navier Stokes Equations
7
作者 Terry E. Moschandreou 《Advances in Pure Mathematics》 2024年第2期118-138,共21页
This article gives a general model using specific periodic special functions, which is degenerate elliptic Weierstrass P functions whose presence in the governing equations through the forcing terms simplify the perio... This article gives a general model using specific periodic special functions, which is degenerate elliptic Weierstrass P functions whose presence in the governing equations through the forcing terms simplify the periodic Navier Stokes equations (PNS) at the centers of cells of the 3-Torus. Satisfying a divergence-free vector field and periodic boundary conditions respectively with a general spatio-temporal forcing term which is smooth and spatially periodic, the existence of solutions which have finite time singularities can occur starting with the first derivative and higher with respect to time. The existence of a subspace of the solution space where v<sub>3</sub> is continuous and {C, y<sub>1</sub>, y<sub>1</sub><sup>2</sup>}, is linearly independent in the additive argument of the solution in terms of the Lambert W function, (y<sub>1</sub><sup>2</sup>=y<sub>2</sub>, C∈R) together with the condition v<sub>2</sub>=-2y<sub>1</sub>v<sub>1</sub>. On this subspace, the Biot Savart Law holds exactly [see Section 2 (Equation (13))]. Also on this subspace, an expression X (part of PNS equations) vanishes which contains all the expressions in derivatives of v<sub>1</sub> and v<sub>2</sub> and the forcing terms in the plane which are related as with the cancellation of all such terms in governing PDE. The y<sub>3</sub> component forcing term is arbitrarily small in ε ball where Weierstrass P functions touch the center of the ball both for inviscid and viscous cases. As a result, a significant simplification occurs with a v<sub>3 </sub>only governing PDE resulting. With viscosity present as v changes from zero to the fully viscous case at v =1 the solution for v<sub>3</sub> reaches a peak in the third component y<sub>3</sub>. Consequently, there exists a dipole which is not centered at the center of the cell of the Lattice. Hence since the dipole by definition has an equal in magnitude positive and negative peak in y<sub>3</sub>, then the dipole Riemann cut-off surface is covered by a closed surface which is the sphere and where a given cell of dimensions [-1, 1]<sup>3</sup> is circumscribed on a sphere of radius 1. For such a closed surface containing a dipole it necessarily follows that the flux at the surface of the sphere of v<sub>3</sub> wrt to surface normal n is zero including at the points where the surface of sphere touches the cube walls. At the finite time singularity on the sphere a rotation boundary condition is deduced. It is shown that v<sub>3</sub> is spatially finite on the Riemann Sphere and the forcing is oscillatory in y<sub>3</sub> component if the velocity v3</sub> is. It is true that . A boundary condition on the sphere shows the rotation of a sphere of viscous fluid. Finally on the sphere a solution for v3</sub> is obtained which is proven to be Hölder continuous and it is shown that it is possible to extend Hölder continuity on the sphere uniquely to all of the interior of the ball. 展开更多
关键词 Navier-Stokes PNS 3-Torus PERIODIC Ball Sphere Hölder continuous Riemann-Surface Uniqueness
下载PDF
Application and Evaluation of Continuous Care Model Based on the Omaha System in Stroke Patients after Discharge
8
作者 Jia LI Yumei GUO Xiaochun LI 《Medicinal Plant》 2024年第1期79-81,84,共4页
[Objectives]To explore the effect of continuous nursing model based on the Omaha system on stroke patients.[Methods]A total of 40 stroke patients in the inpatient department of the Rehabilitation Department of Affilia... [Objectives]To explore the effect of continuous nursing model based on the Omaha system on stroke patients.[Methods]A total of 40 stroke patients in the inpatient department of the Rehabilitation Department of Affiliated Hospital of Jinggangshan University were selected and divided into two groups by the random number table method.Patients in the control group were given routine nursing,and those of the observation group were given continuous nursing based on the Omaha system theory.The score of neurological impairment,daily living ability scale and the quality of life,as well as patients satisfaction rate before and after treatment were compared between the two groups.[Results]The score of neurological impairment,daily living activity ability and the quality of life,as well as patients nursing satisfaction rate in the observation group were significantly better than those of the control group,with statistical significance(P<0.05).[Conclusions]The continuous nursing model based on the Omaha system can significantly improve the neurological function of stroke patients,improve their quality of life and life ability,and promote their rehabilitation. 展开更多
关键词 Omaha system continuous nursing STROKE
下载PDF
Impact of continuous care on cardiac function in patients with lung cancer complicated by coronary heart disease
9
作者 Ting Gao Jin-Lan Luo +3 位作者 Pan Guo Xi-Wen Hu Xiao-Yan Wei Yan Hu 《World Journal of Clinical Cases》 SCIE 2024年第2期314-321,共8页
BACKGROUND Despite sharing similar pathogenic factors,cancer and coronary heart disease(CHD)occur in comparable populations at similar ages and possess similar susceptibility factors.Consequently,it is increasingly co... BACKGROUND Despite sharing similar pathogenic factors,cancer and coronary heart disease(CHD)occur in comparable populations at similar ages and possess similar susceptibility factors.Consequently,it is increasingly commonplace for patients to experience the simultaneous occurrence of cancer and CHD,a trend that is steadily rising.AIM To determine the impacts of continuing care on lung cancer patients with CHD following percutaneous coronary intervention(PCI).METHODS There were 94 lung cancer patients with CHD following PCI who were randomly assigned to the intervention group(n=38)and the control group(n=41).In the intervention group,continuing care was provided,while in the control group,routine care was provided.An evaluation of cardiac and pulmonary function,medication compliance,a 6-min walk test,and patient quality of life was performed.RESULTS Differences between the two groups were significant in left ventricular ejection fraction,6-min walk test,oxygen uptake,quality of life and medication compliance(P<0.05).In comparison with the control group,the enhancement in the intervention group was more significant.The intervention group had more patients with high medication compliance than the control group,with a statistically significant difference(P<0.05).CONCLUSION After undergoing PCI,lung patients with CHD could benefit from continued care in terms of cardiac and pulmonary function,medications compliance,and quality of life. 展开更多
关键词 Lung cancer Continuing care Coronary heart disease Percutaneous coronary intervention
下载PDF
Auto-parametric resonance of a continuous-beam-bridge model under two-point periodic excitation:an experimental investigation and stability analysis
10
作者 Li Yuchun Shen Chao +1 位作者 Liu Wei Li Dong 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2024年第2期445-454,共10页
The auto-parametric resonance of a continuous-beam bridge model subjected to a two-point periodic excitation is experimentally and numerically investigated in this study.An auto-parametric resonance experiment of the ... The auto-parametric resonance of a continuous-beam bridge model subjected to a two-point periodic excitation is experimentally and numerically investigated in this study.An auto-parametric resonance experiment of the test model is conducted to observe and measure the auto-parametric resonance of a continuous beam under a two-point excitation on columns.The parametric vibration equation is established for the test model using the finite-element method.The auto-parametric resonance stability of the structure is analyzed by using Newmark's method and the energy-growth exponent method.The effects of the phase difference of the two-point excitation on the stability boundaries of auto-parametric resonance are studied for the test model.Compared with the experiment,the numerical instability predictions of auto-parametric resonance are consistent with the test phenomena,and the numerical stability boundaries of auto-parametric resonance agree with the experimental ones.For a continuous beam bridge,when the ratio of multipoint excitation frequency(applied to the columns)to natural frequency of the continuous girder is approximately equal to 2,the continuous beam may undergo a strong auto-parametric resonance.Combined with the present experiment and analysis,a hypothesis of Volgograd Bridge's serpentine vibration is discussed. 展开更多
关键词 auto-parametric resonance continuous beam bridge model two-point excitation experimental investigation stability analysis vibration of Volgograd Bridge
下载PDF
Continuous glucose monitoring metrics in pregnancy with type 1 diabetes mellitus
11
作者 Mohammad Sadiq Jeeyavudeen Mairi Crosby Joseph M Pappachan 《World Journal of Methodology》 2024年第1期6-17,共12页
Managing diabetes during pregnancy is challenging,given the significant risk it poses for both maternal and foetal health outcomes.While traditional methods involve capillary self-monitoring of blood glucose level mon... Managing diabetes during pregnancy is challenging,given the significant risk it poses for both maternal and foetal health outcomes.While traditional methods involve capillary self-monitoring of blood glucose level monitoring and periodic HbA1c tests,the advent of continuous glucose monitoring(CGM)systems has revolutionized the approach.These devices offer a safe and reliable means of tracking glucose levels in real-time,benefiting both women with diabetes during pregnancy and the healthcare providers.Moreover,CGM systems have shown a low rate of side effects and high feasibility when used in pregnancies complicated by diabetes,especially when paired with continuous subcutaneous insulin infusion pump as hybrid closed loop device.Such a combined approach has been demonstrated to improve overall blood sugar control,lessen the occurrence of preeclampsia and neonatal hypoglycaemia,and minimize the duration of neonatal intensive care unit stays.This paper aims to offer a comprehensive evaluation of CGM metrics specifically tailored for pregnancies impacted by type 1 diabetes mellitus. 展开更多
关键词 Type 1 diabetes mellitus continuous glucose monitoring PREGNANCY Glycaemic control continuous glucose monitoring system
下载PDF
Application and management of continuous glucose monitoring in diabetic kidney disease
12
作者 Xin-Miao Zhang Quan-Quan Shen 《World Journal of Diabetes》 SCIE 2024年第4期591-597,共7页
Diabetic kidney disease(DKD)is a common complication of diabetes mellitus that contributes to the risk of end-stage kidney disease(ESKD).Wide glycemic var-iations,such as hypoglycemia and hyperglycemia,are broadly fou... Diabetic kidney disease(DKD)is a common complication of diabetes mellitus that contributes to the risk of end-stage kidney disease(ESKD).Wide glycemic var-iations,such as hypoglycemia and hyperglycemia,are broadly found in diabetic patients with DKD and especially ESKD,as a result of impaired renal metabolism.It is essential to monitor glycemia for effective management of DKD.Hemoglobin A1c(HbA1c)has long been considered as the gold standard for monitoring glycemia for>3 months.However,assessment of HbA1c has some bias as it is susceptible to factors such as anemia and liver or kidney dysfunction.Continuous glucose monitoring(CGM)has provided new insights on glycemic assessment and management.CGM directly measures glucose level in interstitial fluid,reports real-time or retrospective glucose concentration,and provides multiple glycemic metrics.It avoids the pitfalls of HbA1c in some contexts,and may serve as a precise alternative to estimation of mean glucose and glycemic variability.Emerging studies have demonstrated the merits of CGM for precise monitoring,which allows fine-tuning of glycemic management in diabetic patients.Therefore,CGM technology has the potential for better glycemic monitoring in DKD patients.More research is needed to explore its application and management in different stages of DKD,including hemodialysis,peritoneal dialysis and kidney transplantation. 展开更多
关键词 Diabetic kidney disease continuous glucose monitoring Glycemic monitoring HEMODIALYSIS Peritoneal dialysis Kidney transplantation
下载PDF
Performance of Continuous Wavelet Transform over Fourier Transform in Features Resolutions
13
作者 Michael K. Appiah Sylvester K. Danuor Alfred K. Bienibuor 《International Journal of Geosciences》 CAS 2024年第2期87-105,共19页
This study presents a comparative analysis of two image enhancement techniques, Continuous Wavelet Transform (CWT) and Fast Fourier Transform (FFT), in the context of improving the clarity of high-quality 3D seismic d... This study presents a comparative analysis of two image enhancement techniques, Continuous Wavelet Transform (CWT) and Fast Fourier Transform (FFT), in the context of improving the clarity of high-quality 3D seismic data obtained from the Tano Basin in West Africa, Ghana. The research focuses on a comparative analysis of image clarity in seismic attribute analysis to facilitate the identification of reservoir features within the subsurface structures. The findings of the study indicate that CWT has a significant advantage over FFT in terms of image quality and identifying subsurface structures. The results demonstrate the superior performance of CWT in providing a better representation, making it more effective for seismic attribute analysis. The study highlights the importance of choosing the appropriate image enhancement technique based on the specific application needs and the broader context of the study. While CWT provides high-quality images and superior performance in identifying subsurface structures, the selection between these methods should be made judiciously, taking into account the objectives of the study and the characteristics of the signals being analyzed. The research provides valuable insights into the decision-making process for selecting image enhancement techniques in seismic data analysis, helping researchers and practitioners make informed choices that cater to the unique requirements of their studies. Ultimately, this study contributes to the advancement of the field of subsurface imaging and geological feature identification. 展开更多
关键词 continuous Wavelet Transform (CWT) Fast Fourier Transform (FFT) Reservoir Characterization Tano Basin Seismic Data Spectral Decomposition
下载PDF
Deep learning algorithm featuring continuous learning for modulation classifications in wireless networks
14
作者 WU Nan SUN Yu WANG Xudong 《太赫兹科学与电子信息学报》 2024年第2期209-218,共10页
Although modulation classification based on deep neural network can achieve high Modulation Classification(MC)accuracies,catastrophic forgetting will occur when the neural network model continues to learn new tasks.In... Although modulation classification based on deep neural network can achieve high Modulation Classification(MC)accuracies,catastrophic forgetting will occur when the neural network model continues to learn new tasks.In this paper,we simulate the dynamic wireless communication environment and focus on breaking the learning paradigm of isolated automatic MC.We innovate a research algorithm for continuous automatic MC.Firstly,a memory for storing representative old task modulation signals is built,which is employed to limit the gradient update direction of new tasks in the continuous learning stage to ensure that the loss of old tasks is also in a downward trend.Secondly,in order to better simulate the dynamic wireless communication environment,we employ the mini-batch gradient algorithm which is more suitable for continuous learning.Finally,the signal in the memory can be replayed to further strengthen the characteristics of the old task signal in the model.Simulation results verify the effectiveness of the method. 展开更多
关键词 Deep Learning(DL) modulation classification continuous learning catastrophic forgetting cognitive radio communications
下载PDF
Lasting Attraction
15
作者 XIA YUANYUAN 《ChinAfrica》 2024年第4期22-24,共3页
High-level opening up and policies to attract foreign direct investment(FDI)were hot topics during the annual sessions of the National People’s Congress(NPC)and the Chinese People’s Political Consultative Conference... High-level opening up and policies to attract foreign direct investment(FDI)were hot topics during the annual sessions of the National People’s Congress(NPC)and the Chinese People’s Political Consultative Conference(CPPCC)National Committee,China’s key annual political meetings commonly known as Two Sessions. 展开更多
关键词 INVESTMENT traction POLITICAL
原文传递
Semi-implantable device based on multiplexed microfilament electrode cluster for continuous monitoring of physiological ions
16
作者 Shuang Huang Shantao Zheng +9 位作者 Mengyi He Chuanjie Yao Xinshuo Huang Zhengjie Liu Qiangqiang Ouyang Jing Liu Feifei Wu Hang Gao Xi Xie Hui-jiuan Chen 《Bio-Design and Manufacturing》 SCIE EI CAS CSCD 2024年第1期88-103,共16页
Modern medicine is increasingly interested in advanced sensors to detect and analyze biochemical indicators.Ion sensors based on potentiometric methods are a promising platform for monitoring physiological ions in bio... Modern medicine is increasingly interested in advanced sensors to detect and analyze biochemical indicators.Ion sensors based on potentiometric methods are a promising platform for monitoring physiological ions in biological subjects.Current semi-implantable devices are mainly based on single-parameter detection.Miniaturized semi-implantable electrodes for multiparameter sensing have more restrictions on the electrode size due to biocompatibility considerations,but reducing the electrode surface area could potentially limit electrode sensitivity.This study developed a semi-implantable device system comprising a multiplexed microfilament electrode cluster(MMEC)and a printed circuit board for real-time monitoring of intra-tissue K^(+),Ca^(2+),and Na^(+)concentrations.The electrode surface area was less important for the potentiometric sensing mechanism,suggesting the feasibility of using a tiny fiber-like electrode for potentiometric sensing.The MMEC device exhibited a broad linear response(K^(+):2–32 mmol/L;Ca^(2+):0.5–4 mmol/L;Na^(+):10–160 mmol/L),high sensitivity(about 20–45 mV/decade),temporal stability(>2weeks),and good selectivity(>80%)for the above ions.In vitro detection and in vivo subcutaneous and brain experiment results showed that the MMEC system exhibits good multi-ion monitoring performance in several complex environments.This work provides a platform for the continuous real-time monitoring of ion fluctuations in different situations and has implications for developing smart sensors to monitor human health. 展开更多
关键词 Multiplexed microfilament electrode cluster Physiological ion sensing Subcutaneous and brain experiment Wearable platform for multi-ion detection continuous real-time monitoring system
下载PDF
Analysis of the Effect of Continuous Nursing Care in Patients with COPD
17
作者 Shan Jia Pei Fan 《Journal of Clinical and Nursing Research》 2024年第1期233-237,共5页
Objective:to study the effect of continuous nursing intervention in patients with chronic obstructive pulmonary disease(COPD).Methods:In this paper,56 COPD patients were selected and grouped by drawing lots,with 28 ca... Objective:to study the effect of continuous nursing intervention in patients with chronic obstructive pulmonary disease(COPD).Methods:In this paper,56 COPD patients were selected and grouped by drawing lots,with 28 cases in each group.The study group underwent continuous nursing intervention,while the control group underwent conventional care,and the parameters of both groups of patients were compared.Results:Compared with the control group,the patients in the study group had a significantly higher forced expiratory volume in one second to forced vital capacity ratio(FEV1/FVC),a significantly lower COPD Assessment Test(CAT)score,and Hamilton Depression(HAM-D)score,and a significantly higher 6-Minute Walk Test(6WMT)score after nursing care.Besides,their self-care ability score and SaO_(2)were significantly higher,while their PaCO_(2)and coagulation indexes were significantly lower(P<0.05).Conclusion:Continuous nursing intervention is beneficial for COPD patients. 展开更多
关键词 continuous nursing intervention Chronic obstructive pulmonary disease
下载PDF
Effects of Continuous Precision Nursing Model on Knowledge, Attitudes, and Practices (KAP) Behavior and Cardiac Function in Patients after Percutaneous Coronary Angiography and Stent Implantation
18
作者 Cuiying Han 《Journal of Clinical and Nursing Research》 2024年第3期1-6,共6页
Objective:To explore the impact of a continuous precision nursing model on patients’Knowledge,Attitudes,and Practices(KAP)and cardiac function during the nursing process of patients undergoing percutaneous coronary a... Objective:To explore the impact of a continuous precision nursing model on patients’Knowledge,Attitudes,and Practices(KAP)and cardiac function during the nursing process of patients undergoing percutaneous coronary angiography and stent implantation.Methods:Ninety patients who underwent percutaneous coronary angiography and stent implantation in our hospital from April 2022 to April 2023 were selected and randomly divided into the control group(45 cases),in which routine nursing support was carried out during the treatment process,and the observation group(45 cases),in which continuous precision nursing model was carried out during the treatment process.Comparisons were made between the two groups of patients on their KAP,cardiac function,and quality of life during recovery.Results:There was no difference in the left ventricular ejection fraction(LVEF),cardiac output(CO),and cardiac index(CI)levels before intervention.After the intervention,the levels of cardiac function in the observation group were higher than those of the control group(P<0.05).There was no difference in the Exercise of Self-Care Agency(ESCA)self-care ability scale scores before the intervention.After the intervention,the observation group had higher ESCA scores than the control group(P<0.05).Conclusion:Implementation of a continuous precision nursing model in the care of patients undergoing percutaneous coronary angiography and stent implantation improved the patient’s cardiac function,and KAP,and promoted recovery. 展开更多
关键词 continuous precision nursing model Percutaneous coronary angiography Stent implantation Knowledge attitudes and practices(KAP) Cardiac function
下载PDF
Fiber Traction Printing:A 3D Printing Method of Continuous Fiber Reinforced Metal Matrix Composite 被引量:5
19
作者 Xin Wang Xiaoyong Tian +1 位作者 Qin Lian Dichen Li 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2020年第2期69-79,共11页
A novel metal matrix composite freeform fabrication approach,fiber traction printing(FTP),is demonstrated through controlling the wetting behavior between fibers and the matrix.This process utilizes the fiber bundle t... A novel metal matrix composite freeform fabrication approach,fiber traction printing(FTP),is demonstrated through controlling the wetting behavior between fibers and the matrix.This process utilizes the fiber bundle to control the cross-sectional shape of the liquid metal,shaping it from circular to rectangular which is more precise.The FTP process could resolve manufacturing difficulties in the complex structure of continuous fiber reinforced metal matrix composites.The printing of the first layer monofilament is discussed in detail,and the effects of the fibrous coating thickness on the mechanical properties and microstructures of the composite are also investigated in this paper.The composite material prepared by the FTP process has a tensile strength of 235.2 MPa,which is close to that of composites fabricated by conventional processes.The complex structures are printed to demonstrate the advantages and innovations of this approach.Moreover,the FTP method is suited to other material systems with good wettability,such as modified carbon fiber,surfactants,and aluminum alloys. 展开更多
关键词 3D printing Metal matrix composite CAPILLARITY continuous carbon fiber
下载PDF
ESTIMATION OF ATTRACTION DOMAIN AND EXPONENTIAL CONVERGENCE RATE OF CONTINUOUS FEEDBACK ASSOCIATIVE MEMORY AND ITS APPLICATIONS 被引量:1
20
作者 Liang Xuebin Wu Lide(Department of Computer Science, Fudan University, Shanghai 200433) 《Journal of Electronics(China)》 1996年第2期129-133,共5页
The attraction domains of memory patterns and exponential convergence rate of the network trajectories to memory patterns for continuous feedback associative memory are estimated. These results can be used for evaluat... The attraction domains of memory patterns and exponential convergence rate of the network trajectories to memory patterns for continuous feedback associative memory are estimated. These results can be used for evaluation of error-correction capability and the synthesis procedures for continuous-time associative memory neural networks. 展开更多
关键词 continuous FEEDBACK ASSOCIATIVE memory Neural network ATtraction DOMAIN EXPONENTIAL convergence rate
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部