期刊文献+
共找到1,225篇文章
< 1 2 62 >
每页显示 20 50 100
Dynamic modeling and direct power control of wind turbine driven DFIG under unbalanced network voltage conditions 被引量:2
1
作者 Jia-bing HU Yi-kang HE Lie XU 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2008年第12期1731-1740,共10页
This paper proposes an analysis and a direct power control (DPC) design of a wind turbine driven doubly-fed induction generator (DFIG) under unbalanced network voltage conditions. A DFIG model described in the positiv... This paper proposes an analysis and a direct power control (DPC) design of a wind turbine driven doubly-fed induction generator (DFIG) under unbalanced network voltage conditions. A DFIG model described in the positive and negative synchronous reference frames is presented. Variations of the stator output active and reactive powers are fully deduced in the presence of negative sequence supply voltage and rotor flux. An enhanced DPC scheme is proposed to eliminate stator active power oscillation during network unbalance. The proposed control scheme removes rotor current regulators and the decomposition processing of positive and negative sequence rotor currents. Simulation results using PSCAD/EMTDC are presented on a 2-MW DFIG wind power generation system to validate the feasibility of the proposed control scheme under balanced and unbalanced network conditions. 展开更多
关键词 Doubly-fed induction generator (DFIG) Wind turbine direct power control (DPC) Stator voltage oriented (SVO) Unbalanced network
下载PDF
Predictive direct power control of three-phase PWM rectifier based on TOGI grid voltage sensor free algorithm
2
作者 ZHAO Feng LI Shute +4 位作者 CHEN Xiaoqiang WANG Ying GAN Yanqi NIU Xinqiang ZHANG Fan 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2022年第4期451-459,共9页
In predictive direct power control(PDPC)system of three-phase pulse width modulation(PWM)rectifier,grid voltage sensor makes the whole system more complex and costly.Therefore,third-order generalized integrator(TOGI)i... In predictive direct power control(PDPC)system of three-phase pulse width modulation(PWM)rectifier,grid voltage sensor makes the whole system more complex and costly.Therefore,third-order generalized integrator(TOGI)is used to generate orthogonal signals with the same frequency to estimate the grid voltage.In addition,in view of the deviation between actual and reference power in the three-phase PWM rectifier traditional PDPC strategy,a power correction link is designed to correct the power reference value.The grid voltage sensor free algorithm based on TOGI and the corrected PDPC strategy are applied to three-phase PWM rectifier and simulated on the simulation platform.Simulation results show that the proposed method can effectively eliminate the power tracking deviation and the grid voltage.The effectiveness of the proposed method is verified by comparing the simulation results. 展开更多
关键词 three-phase PWM rectifier predictive direct power control grid voltage sensor free algorithm third-order generalized integrator power correction
下载PDF
Direct Power Control of Variable Wind Speed Based on the Doubly Fed Asynchronous Machine
3
作者 Abdelhafidh Moualdia Lazhari Nezli Mohand Oulhadj Mahmoudi 《Journal of Energy and Power Engineering》 2012年第6期1005-1011,共7页
In this work, the authors propose the study of a wind speed variable based on the DFAM (double fed asynchronous machine). The model of the turbine is drawn from the classical equations describing the operation of a ... In this work, the authors propose the study of a wind speed variable based on the DFAM (double fed asynchronous machine). The model of the turbine is drawn from the classical equations describing the operation of a variable wind speed. The torque generated by the turbine is applied to the DFAM directly connected on the network side and the stator via a bidirectional converter side rotor. This configuration allows velocity variations of ±30% around the synchronous speed and the converter is then sized to one third of the rated power of the machine. The DFAM is controlled by a control vector ensuring operation of the wind turbine power coefficient maximum. 展开更多
关键词 DFAM (double fed asynchronous machine) variable wind speed direct power control energy quality.
下载PDF
Direct Power Control Based on Dead-beat Function and Extended Kalman Filter for PV Systems
4
作者 Mostafa Ahmed Ibrahim Harbi +1 位作者 Ralph Kennel Mohamed Abdelrahem 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2023年第3期863-872,共10页
In this paper,a new proposal for the implementation of the well-known direct power control(DPC)technique in grid-connected photovoltaic(PV)systems is suggested.Normally,the DPC is executed using a look-up table proced... In this paper,a new proposal for the implementation of the well-known direct power control(DPC)technique in grid-connected photovoltaic(PV)systems is suggested.Normally,the DPC is executed using a look-up table procedure based on the error between the actual and reference values of the active and reactive power.Thus,the structure of the DPC is simple and results in a fast transient behavior of the inner current loop(injected currents).Therefore,in the current study,the DPC is reformulated using a dead-beat function.In this formulation,the reference voltage vector(RVV)is obtained in theα-βreference frame.Consequently,the switching states for the inverter can be obtained based on the sign of the components of the RVV.The suggested DPC is compared with the conventional one and other switching tables,which are intended for performance enhancement.Furthermore,an extended Kalman filter(EKF)is utilized to eliminate all grid-voltage sensors.Moreover,the switching frequency of the proposed technique is minimized without any need for weighting factors or cost function evaluation.The overall control technique is validated using a hardware-in-the-loop(HIL)experimental set-up and compared with other schemes under different operating conditions. 展开更多
关键词 Photovoltaic(PV)system direct power control(DPC) sensorless control switching frequency minimization weighting factor
原文传递
Direct power control for three-level PWM rectifier based on hysteresis strategy 被引量:5
5
作者 SHI TingNa WANG Jian +1 位作者 ZHANG Ce XIA ChangLiang 《Science China(Technological Sciences)》 SCIE EI CAS 2012年第11期3019-3028,共10页
This paper presents a mathematical model of three-level voltage PWM rectifier,and derives a power control model from the theory of instantaneous power.In the vector-space,the influences on instantaneous power exercise... This paper presents a mathematical model of three-level voltage PWM rectifier,and derives a power control model from the theory of instantaneous power.In the vector-space,the influences on instantaneous power exercised by all the switching vectors are studied and illustrated separately,then a direct power control(DPC) scheme for three-level PWM rectifier which uses multistage band hysteresis comparator is proposed,and a novel switching table is designed.Meanwhile,the neutralpoint voltage unbalance is inhibited by selecting the redundancy switching states of small voltage vectors.Simulation and experimental results show that the proposed strategy can not only stabilize the DC bus voltage but also realize the unity power factor operation and the balance of neutral-point voltage.Moreover,the proposed method can improve the performance of the three-level rectifier. 展开更多
关键词 direct power control hysteresis control instantaneous power neutral-point voltage balance switching table three-levelPWM rectifier
原文传递
Multiple target implementation for a doubly fed induction generator based on direct power control under unbalanced and distorted grid voltage 被引量:2
6
作者 Heng NIAN Yi-peng SONG 《Frontiers of Information Technology & Electronic Engineering》 SCIE EI CSCD 2015年第4期321-334,共14页
This paper presents a multiple target implementation technique for a doubly fed induction generator (DFIG) under unbalanced and distorted grid voltage based on direct power control (DPC). Based on the mathematical... This paper presents a multiple target implementation technique for a doubly fed induction generator (DFIG) under unbalanced and distorted grid voltage based on direct power control (DPC). Based on the mathematical model of DFIG under unbalanced and distorted voltage, the proportional and integral (PI) regulator is adopted to regulate the DFIG average active and reactive powers, while the vector P1 (VPI) resonant regulator is used to achieve three alternative control targets: (1) balanced and sinusoidal stator current; (2) smooth instantaneous stator active and reactive powers; (3) smooth electromagnetic torque and instantaneous stator reactive power. The major advantage of the proposed control strategy over the conventional method is that neither negative and harmonic sequence decomposition of grid voltage nor complicated control reference calculation is required. The insensitivity of the proposed control strategy to DFIG parameter deviation is analyzed. Finally, the DFIG experimental system is developed to validate the availability of the proposed DPC strategy under unbalanced and distorted grid voltage, 展开更多
关键词 direct power control Doubly fed induction generator Unbalanced and distorted grid voltage Vector proportionaland integral resonant regulator Parameter deviation
原文传递
Improved Model Predictive Direct Power Control of Grid Side Converter in Weak Grid Using Kalman Filter and DSOGI 被引量:4
7
作者 Liang Chen Heng Nian Yunyang Xu 《Chinese Journal of Electrical Engineering》 CSCD 2019年第4期22-32,共11页
When grid side converter(GSC)is connected to weak grid,the small signal instability can happen due to terminal characteristics of the GSC that are incompatible with the grid impedance.This issue is not of wide concern... When grid side converter(GSC)is connected to weak grid,the small signal instability can happen due to terminal characteristics of the GSC that are incompatible with the grid impedance.This issue is not of wide concern in previous studies of direct power control(DPC)of GSC.By small signal analysis,it is shown that the impedance characteristic of the conventional direct power control GSC is not compatible with the inductive grid impedance in weak grid due to its constant power load behavior.To solve the problem,instead of feeding the DPC controller with direct measured voltage and current,a Kalman filter(KF)is used to obtain filtered output current and a double second-order generalized integrator(DSOGI)is used to obtain filtered voltage at the point of common coupling(PCC).These strategies change the impedance characteristic of the GSC dramatically and make it suitable to operate in weak grid where SCR is 2,while the rapid power response is preserved.The proposed strategy is verified through simulation and controller hardware in loop(CHIL)tests. 展开更多
关键词 direct power control weak grid grid side converter STABILITY
原文传递
Improved three-vector based dead-beat model predictive direct power control strategy for grid-connected inverters
8
作者 Chen-wen CHENG Heng NIAN Long-qi LI 《Frontiers of Information Technology & Electronic Engineering》 SCIE EI CSCD 2018年第11期1420-1431,共12页
Since only one inverter voltage vector is applied during each duty cycle, traditional model predictive direct power control(MPDPC) for grid-connected inverters(GCIs) results in serious harmonics in current and power. ... Since only one inverter voltage vector is applied during each duty cycle, traditional model predictive direct power control(MPDPC) for grid-connected inverters(GCIs) results in serious harmonics in current and power. Moreover, a high sampling frequency is needed to ensure satisfactory steady-state performance, which is contradictory to its long execution time due to the iterative prediction calculations. To solve these problems, a novel dead-beat MPDPC strategy is proposed, using two active inverter voltage vectors and one zero inverter voltage vector during each duty cycle. Adoption of three inverter vectors ensures a constant switching frequency. Thus, smooth steady-state performance of both current and power can be obtained. Unlike the traditional three-vector based MPDPC strategy, the proposed three vectors are selected based on the power errors rather than the sector where the grid voltage vector is located, which ensures that the duration times of the selected vectors are positive all the time. Iterative calculations of the cost function in traditional predictive control are also removed, which makes the proposed strategy easy to implement on digital signal processors(DSPs) for industrial applications. Results of experiments based on a 1 kW inverter setup validate the feasibility of the proposed three-vector based dead-beat MPDPC strategy. 展开更多
关键词 GRID-CONNECTED inverter Model predictive control direct power control THREE vectors Constant switching frequency power errors
原文传递
Review on grid-forming converter control methods in high-proportion renewable energy power systems 被引量:8
9
作者 Yuting Teng Wei Deng +3 位作者 Wei Pei Yifeng Li Li Ding Hua Ye 《Global Energy Interconnection》 EI CAS CSCD 2022年第3期328-342,共15页
Grid-forming(GFM)converters can provide inertia support for power grids through control technology,stabilize voltage and frequency,and improve system stability,unlike traditional grid-following(GFL)converters.Therefor... Grid-forming(GFM)converters can provide inertia support for power grids through control technology,stabilize voltage and frequency,and improve system stability,unlike traditional grid-following(GFL)converters.Therefore,in future“double high”power systems,research on the control technology of GFM converters will become an urgent demand.In this paper,we first introduce the basic principle of GFM control and then present five currently used control strategies for GFM converters:droop control,power synchronization control(PSC),virtual synchronous machine control(VSM),direct power control(DPC),and virtual oscillator control(VOC).These five strategies can independently establish voltage phasors to provide inertia to the system.Among these,droop control is the most widely used strategy.PSC and VSM are strategies that simulate the mechanical characteristics of synchronous generators;thus,they are more accurate than droop control.DPC regulates the active power and reactive power directly,with no inner current controller,and VOC is a novel method under study using an oscillator circuit to realize synchronization.Finally,we highlight key technologies and research directions to be addressed in the future. 展开更多
关键词 Grid-forming control Droop control power synchronization control Virtual synchronous machine control direct power control Virtual oscillator control
下载PDF
Rooted Tree Optimization for Wind Turbine Optimum Control Based on Energy Storage System
10
作者 Billel Meghni Afaf Benamor +7 位作者 Oussama Hachana Ahmad Taher Azar Amira Boulmaiz Salah Saad El-Sayed M.El-kenawy Nashwa Ahmad Kamal Suliman Mohamed Fati Naglaa K.Bahgaat 《Computers, Materials & Continua》 SCIE EI 2023年第2期3977-3996,共20页
The integration of wind turbines(WTs)in variable speed drive systems belongs to the main factors causing lowstability in electrical networks.Therefore,in order to avoid this issue,WTs hybridization with a storage syst... The integration of wind turbines(WTs)in variable speed drive systems belongs to the main factors causing lowstability in electrical networks.Therefore,in order to avoid this issue,WTs hybridization with a storage system is a mandatory.This paper investigates WT system operating at variable speed.The system contains of a permanent magnet synchronous generator(PMSG)supported by a battery storage system(BSS).To enhance the quality of active and reactive power injected into the network,direct power control(DPC)scheme utilizing space-vector modulation(SVM)technique based on proportional-integral(PI)control is proposed.Meanwhile,to improve the rendition of this method(DPC-SVM-PI),the rooted tree optimization technique(RTO)algorithm-based controller parameter identification is used to achieve PI optimal gains.To compare the performance ofRTO-based controllers,they were implemented and tested along with some other popular controllers under different working conditions.The obtained results have shown the supremacy of the suggested PIRTO algorithm compared to competing controllers regarding total harmonic distortion(THD),overshoot percentage,settling time,rise time,average active power value,overall efficiency,and active power steadystate error. 展开更多
关键词 Rooted tree optimization(RTO)method direct power control(DPC) wind turbine(WT) proportional integral(PI) PMSG
下载PDF
Direct Torque Control System and Sensorless Technique of Permanent Magnet Synchronous Motor 被引量:10
11
作者 胡育文 田淳 +2 位作者 游志青 汤立新 M.F.Rahman 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2003年第2期97-102,共6页
The direct torque control theory has achieved great success in the control ofinduction motors. However, in the DTC drive system of Permanent Magnet Synchronous Machine (PMSM)proposed a few years ago, there are many ba... The direct torque control theory has achieved great success in the control ofinduction motors. However, in the DTC drive system of Permanent Magnet Synchronous Machine (PMSM)proposed a few years ago, there are many basic theoretical problems that must be clarified. Thispaper describes an investigation about the effect of the zero voltage space vectors in the DTCsystem of PMSM and points out that if using the zero voltage space vectors rationally, not only canthe DTC system be driven successfully but also the torque ripple is reduced and the performance ofthe system is improved. This paper also studies the sensorless technique in the DTC system of PMSMand configures the DTC system of PMSM with sensorless technique including zero voltage spacevectors. Numerical simulations and experimental tests have proved the theory correct. In thecondition of sensor-less, the DTC system of PMSM is wide-rangely speed adjusting, and the ratio ofspeed adjustment is 1: 100. 展开更多
关键词 power electronics direct torque control permanent magnet motors SENSORLESS stator flux linkage
下载PDF
基于分数阶滑模控制的光伏并网模型预测直接功率控制
12
作者 张晓英 游紫萱 +2 位作者 罗童 张兴平 王晓兰 《深圳大学学报(理工版)》 CAS CSCD 北大核心 2024年第6期669-678,共10页
针对外界扰动情况下的光伏并网模型预测直接功率控制(model predictive direct power control,MPDPC)系统中存在系统抖振、功率跟踪速度慢、并网电流总谐波失真率较高等问题,提出一种改进分数阶滑模电压控制器,该策略在直流侧母线电压... 针对外界扰动情况下的光伏并网模型预测直接功率控制(model predictive direct power control,MPDPC)系统中存在系统抖振、功率跟踪速度慢、并网电流总谐波失真率较高等问题,提出一种改进分数阶滑模电压控制器,该策略在直流侧母线电压外环采用了分数阶微积分理论.首先,构造分数阶非奇异快速终端滑模面函数,削弱系统抖振,提高系统动态性能;然后,构造分数阶双幂次指数趋近律,引入加权积分型增益和饱和函数,有效避免系统在非滑动模态阶段时切换增益的增大,提高系统控制精度;最后,设计新型分数阶电压环控制器并运用于光伏并网系统中.研究结果表明,改进后的分数阶滑模电压控制器能够满足光伏并网MPDPC系统的各项基本需求,抑制系统抖振,提高功率跟踪性能,降低并网电流总谐波失真率,有效解决可再生能源和公共电网电能转化的关键难题,对光伏并网系统高性能控制的理论研究具有重要意义. 展开更多
关键词 电气工程 光伏发电 并网系统 分数阶微积分 滑模控制 模型预测直接功率控制 电压环控制器
下载PDF
Frequency Control of Power System with Renewable Power Sources by HVDC Interconnection Line and Battery Considering Energy Balancing
13
作者 Shoyu Onuka Atsushi Umemura +4 位作者 Rion Takahashi Junji Tamura Atsushi Sakahara Fumihito Tosaka Ryosuke Nakamoto 《Journal of Power and Energy Engineering》 2020年第4期11-24,共14页
Recently, introduction of renewable energy sources like wind power generation and photovoltaic power generation has been increasing from the viewpoint of environmental problems. However, renewable energy power supplie... Recently, introduction of renewable energy sources like wind power generation and photovoltaic power generation has been increasing from the viewpoint of environmental problems. However, renewable energy power supplies have unstable output due to the influence of weather conditions such as wind speed variations, which may cause fluctuations of voltage and frequency in the power system. This paper proposes fuzzy PD based virtual inertia control system to decrease frequency fluctuations in power system caused by fluctuating output of renewable energy sources. The proposed new method is based on the coordinated control of HVDC interconnection line and battery, and energy balancing control is also incorporated in it. Finally, it is concluded that the proposed system is very effective for suppressing the frequency fluctuations of the power system due to the large-scale wind power generation and solar power generation and also for keeping the energy balancing in the HVDC transmission line. 展开更多
关键词 High Voltage direct Current (HVDC) Transmission power System Frequency control COORDINATED control BATTERY RENEWABLE power Energy Balancing
下载PDF
高频链矩阵变换器直接功率反步控制策略
14
作者 魏业文 白文静 李明 《电机与控制学报》 EI CSCD 北大核心 2024年第7期55-64,共10页
针对高频链矩阵变换器(HFLMC)电路前后级耦合导致系统动态性能和鲁棒性降低的问题,提出一种基于直接功率的非线性反步控制策略(BS-DPC)。首先,建立HFLMC非线性数学模型和有功、无功功率动态模型,分析双极性电流空间矢量调制策略;然后,... 针对高频链矩阵变换器(HFLMC)电路前后级耦合导致系统动态性能和鲁棒性降低的问题,提出一种基于直接功率的非线性反步控制策略(BS-DPC)。首先,建立HFLMC非线性数学模型和有功、无功功率动态模型,分析双极性电流空间矢量调制策略;然后,在考虑系统不确定性情况下引入2个解耦控制分量,设计直流输出电流和无功功率反步控制器,实现电池不同工况下输出电流参考值的快速跟踪控制;最后,根据李雅普诺夫稳定性理论证明HFLMC闭环系统全局渐进稳定性,并对比传统PI直接功率控制和BS-DPC策略。仿真和实验结果表明,所提BS-DPC策略控制HFLMC提高了输出电流的动态性能和电网波动及直流滤波电感变化下的鲁棒性,响应时间减少了约78%,网侧THD降低了0.98%。 展开更多
关键词 高频链矩阵变换器 双极性电流空间矢量调制 PI直接功率控制 直接功率反步控制 动态响应 鲁棒性
下载PDF
基于改进型Super-twisting的双馈感应发电机直接功率控制
15
作者 李圣清 文颜烯 +2 位作者 黄远鹏 周志飞 陈欣 《太阳能学报》 EI CAS CSCD 北大核心 2024年第10期529-535,共7页
为提高双馈感应发电机(DFIG)直接功率控制的鲁棒性和抗干扰能力,提出一种改进型超螺旋滑模(STSMC)的直接功率控制(DPC)。首先,建立参数摄动下的DFIG最大功率捕获模型和定子磁场定向的双馈感应发电机模型;然后,将非奇异快速终端滑模面(NF... 为提高双馈感应发电机(DFIG)直接功率控制的鲁棒性和抗干扰能力,提出一种改进型超螺旋滑模(STSMC)的直接功率控制(DPC)。首先,建立参数摄动下的DFIG最大功率捕获模型和定子磁场定向的双馈感应发电机模型;然后,将非奇异快速终端滑模面(NFTSM)与一种改进型超螺旋(Super-twisting)优化算法结合,设计DFIG直接功率控制器(IST-NFTSMC)。其中所设计的非奇异滑模面能有效避免传统滑模控制(SMC)的奇异现象,且改进超螺旋控制律能有效削弱NFTSMC抖振,提高功率控制精度;最后,通过仿真和实验,与PI控制和传统SMC控制相比,该控制能削弱DFIG功率与电流抖振问题,加快其收敛速度,提高DFIG直接功率控制稳态精度。 展开更多
关键词 双馈感应发电机 直接功率控制 超螺旋滑模控制 定子磁场定向
原文传递
三重移相控制的DAB变换器多目标统一优化控制策略
16
作者 曾进辉 饶尧 +1 位作者 兰征 何东 《电源学报》 CSCD 北大核心 2024年第5期74-85,132,共13页
针对双有源桥变换器存在电流应力大、全部开关管软开关实现困难以及动态响应慢的问题,提出1种基于三重移相控制的多目标统一优化控制策略。分析三重移相控制正向功率流的全局模式,选出其中3种高效率模式并建立电流应力和软开关解析模型... 针对双有源桥变换器存在电流应力大、全部开关管软开关实现困难以及动态响应慢的问题,提出1种基于三重移相控制的多目标统一优化控制策略。分析三重移相控制正向功率流的全局模式,选出其中3种高效率模式并建立电流应力和软开关解析模型。结合模型,采用成本函数优化方程推导不同模式下的最优移相比组合和最小电流应力,使开关管运行在零电压开关功率约束范围内。同时在效率优化过程中引入虚拟功率分量,构建小信号模型并阐明不同状态变量的小扰动对输出电压的影响较小。实验结果表明,所提控制策略可以在全功率范围内降低双有源桥变换器的电流应力且使所有开关管实现零电压开通,同时还能够提高输出电压的动态性能。 展开更多
关键词 双有源桥变换器 三重移相控制 电流应力 软开关 虚拟直接功率控制
下载PDF
Frequency Control of Power System with Solar and Wind Power Stations by Using Frequency Band Control and Deadband Control of HVDC Interconnection Line
17
作者 Kimiko Tada Takamasa Sato +5 位作者 Atsushi Umemura Rion Takahashi Junji Tamura Yoshiharu Matsumura Tsukasa Taguchi Akira Yamada 《Journal of Power and Energy Engineering》 2018年第9期48-63,共16页
In recent years, environmental problems are becoming serious and renewable energy has attracted attention as their solutions. However, the electricity generation using the renewable energy has a demerit that the outpu... In recent years, environmental problems are becoming serious and renewable energy has attracted attention as their solutions. However, the electricity generation using the renewable energy has a demerit that the output becomes unstable because of intermittent characteristics, such as variations of wind speed or solar radiation intensity. Frequency fluctuations due to the installation of large scale wind farm (WF) and photovoltaics (PV) into the power system is a major concern. In order to solve the problem, this paper proposes two control methods using High Voltage Direct Current (HVDC) interconnection line to suppress the frequency fluctuations due to large scale of WF and PV. Comparative analysis between these two control methods is presented in this paper. One proposed method is a frequency control using a notch filter, and the other is using a deadband. Validity of the proposed methods is verified through simulation analyses, which is performed on a multi-machine power system model. 展开更多
关键词 High Voltage direct Current (HVDC) System Frequency control PV power GENERATION Wind power GENERATION Notch Filter Deadband
下载PDF
混合级联特高压直流功率损失计算方法研究
18
作者 刘凯 赵文强 +1 位作者 侍乔明 王永平 《电力电子技术》 2024年第6期50-53,60,共5页
混合级联特高压直流(UHVDC)在降低直流换相失败风险的同时提升了直流输电的灵活性,但由于LCC与VSC混合拓扑导致不同阀组闭锁后健全阀组的功率传输能力存在不确定性,影响了直流功率损失准确计算。此处提出了一种适用于混合级联UHVDC的功... 混合级联特高压直流(UHVDC)在降低直流换相失败风险的同时提升了直流输电的灵活性,但由于LCC与VSC混合拓扑导致不同阀组闭锁后健全阀组的功率传输能力存在不确定性,影响了直流功率损失准确计算。此处提出了一种适用于混合级联UHVDC的功率损失计算方法。直流控制系统以极为单位计算阀组闭锁后的直流功率并发送安控系统计算直流功率损失,设计了合理接口与数据处理方式保证阀组单次及相继故障直流功率损失计算的准确性。最后通过试验,验证了所提方法的正确性与有效性。 展开更多
关键词 混合级联特高压直流 功率损失计算 控制系统
下载PDF
增程器无刷直流发电系统直接转矩控制策略研究
19
作者 张兰红 徐扬 陈永楼 《微特电机》 2024年第11期30-35,共6页
为提高电动汽车增程器无刷直流发电系统的动静态性能,提出通过控制电磁转矩来快速保持系统输出电压的稳定。对无刷直流发电系统直接转矩控制的理论依据进行了推导,研究了无刷直流发电系统直接转矩控制的原理,指出通过选择交轴分量最大... 为提高电动汽车增程器无刷直流发电系统的动静态性能,提出通过控制电磁转矩来快速保持系统输出电压的稳定。对无刷直流发电系统直接转矩控制的理论依据进行了推导,研究了无刷直流发电系统直接转矩控制的原理,指出通过选择交轴分量最大的电压矢量作用于电机,可迅速控制电磁转矩。分析了电压矢量的特点,建立了无刷直流发电系统直接转矩控制电压矢量选择表。仿真和实验结果表明,采用直接转矩控制的无刷直流发电系统具有优良的动、静态性能。 展开更多
关键词 电动汽车 增程器 无刷直流电机 发电 直接转矩控制
下载PDF
基于模型预测的直驱式波浪发电机机侧最优功率控制技术 被引量:1
20
作者 黄磊 魏莱 +1 位作者 杨建龙 胡敏强 《电工技术学报》 EI CSCD 北大核心 2024年第14期4391-4404,共14页
直驱式波浪发电系统具有结构简单、成本低、效率高等优点,得到了国内外学者的广泛关注。该文以直驱式波浪发电系统为研究对象,分析并建立了直驱式波浪发电装置的水动力数学模型和永磁直线电机的动态数学模型。推导了基于模型预测的功率... 直驱式波浪发电系统具有结构简单、成本低、效率高等优点,得到了国内外学者的广泛关注。该文以直驱式波浪发电系统为研究对象,分析并建立了直驱式波浪发电装置的水动力数学模型和永磁直线电机的动态数学模型。推导了基于模型预测的功率控制策略用于直驱式波浪发电系统。在功率控制策略中从功率捕获策略和功率跟踪控制策略展开研究以实现将波浪能转换为电能并汇入直流母线。重点围绕功率捕获策略开展基于模型预测控制技术研究,分别从控制策略、预测区间和成本函数三个角度分析了基于模型预测的最优功率捕获策略。建立了仿真模型并进行仿真分析,结果表明,采用基于模型预测的最优功率捕获策略可有效提高不规则波下发电机从波浪发电系统捕获能量。此外,采用以直流母线功率汇入最大为目标的成本函数可以有效地提高发电机输入直流侧能量,具有重要的实用价值。最后通过实验室模拟平台进行了实验测试。 展开更多
关键词 直驱式波浪发电 最优功率捕获 模型预测控制 功率跟踪控制
下载PDF
上一页 1 2 62 下一页 到第
使用帮助 返回顶部