期刊文献+
共找到380篇文章
< 1 2 19 >
每页显示 20 50 100
Disinfection Byproducts and Their Precursors in Drinking Water Sources:Origins,Influencing Factors,and Environmental Insights
1
作者 Rong Xiao Yang Deng +1 位作者 Zuxin Xu Wenhai Chu 《Engineering》 SCIE EI CAS CSCD 2024年第5期36-50,共15页
Tracing the contamination origins in water sources and identifying the impacts of natural and human processes are essential for ecological safety and public health.However,current analysis approaches are not ideal,as ... Tracing the contamination origins in water sources and identifying the impacts of natural and human processes are essential for ecological safety and public health.However,current analysis approaches are not ideal,as they tend to be laborious,time-consuming,or technically difficult.Disinfection byproducts(DBPs)are a family of well-known secondary pollutants formed by the reactions of chemical disinfectants with DBP precursors during water disinfection treatment.Since DBP precursors have various origins(e.g.,natural,domestic,industrial,and agricultural sources),and since the formation of DBPs from different precursors in the presence of specific disinfectants is distinctive,we argue that DBPs and DBP precursors can serve as alternative indicators to assess the contamination in water sources and identify pollution origins.After providing a retrospective of the origins of DBPs and DBP precursors,as well as the specific formation patterns of DBPs from different precursors,this article presents an overview of the impacts of various natural and anthropogenic factors on DBPs and DBP precursors in drinking water sources.In practice,the DBPs(i.e.,their concentration and speciation)originally present in source water and the DBP precursors determined using DBP formation potential tests—in which water samples are dosed with a stoichiometric excess of specific disinfectants in order to maximize DBP formation under certain reaction conditions—can be considered as alternative metrics.When jointly used with other water quality parameters(e.g.,dissolved organic carbon,dissolved organic nitrogen,fluorescence,and molecular weight distribution)and specific contaminants of emerging concern(e.g.,certain pharmaceuticals and personal care products),DBPs and DBP precursors in drinking water sources can provide a more comprehensive picture of water pollution for better managing water resources and ensuring human health. 展开更多
关键词 disinfection byproducts disinfection byproduct precursors Drinking water sources Contamination indicator Natural factors Human factors
下载PDF
Evaluation of the Impact of Refined Quality Control Management Model on the Qualified Rate of Disinfection and Sterilization of Surgical Instruments in the Sterilization Supply Center 被引量:1
2
作者 Qin Liu 《Journal of Clinical and Nursing Research》 2024年第1期168-173,共6页
Objective:To evaluate the application value of a refined quality control management model for a sterilization supply center.Methods:A retrospective analysis was conducted on the work situation of the sterilization sup... Objective:To evaluate the application value of a refined quality control management model for a sterilization supply center.Methods:A retrospective analysis was conducted on the work situation of the sterilization supply center from January 2021 to January 2023.The work situation before January 31,2022,was classified as the control group;a routine quality control management model was implemented,and the work situation after January 31,2022,was classified as the observation group.The quality of medical device management and department satisfaction between the two groups were compared.Results:The timely recovery and supply rate,classification and cleaning pass rate,disinfection pass rate,packaging pass rate,sterilization pass rate,and department satisfaction score in the observation group were all higher than those of the control group(P<0.05).Conclusion:Implementing a refined quality control management model in the sterilization supply center can improve the quality management level of medical devices and department satisfaction and is worthy of promotion. 展开更多
关键词 Refined quality control management model Sterilization supply center disinfection and sterilization pass rate
下载PDF
Double enzyme mimetic activities of multifunctional Ag nanoparticle-decorated Co_(3)V_(2)O_(8)hollow hexagonal prismatic pencils for application in colorimetric sensors and disinfection
3
作者 Ying Gao Peng Ju +4 位作者 Yu Zhang Yuxin Zhang Xiaofan Zhai Jizhou Duan Baorong Hou 《Nano Materials Science》 EI CAS CSCD 2024年第2期244-255,共12页
Since the catalytic activity of most nanozymes is still far lower than the corresponding natural enzymes,there is urgent need to discover novel highly efficient enzyme-like materials.In this work,Co_(3)V_(2)O_(8)with ... Since the catalytic activity of most nanozymes is still far lower than the corresponding natural enzymes,there is urgent need to discover novel highly efficient enzyme-like materials.In this work,Co_(3)V_(2)O_(8)with hollow hexagonal prismatic pencil structures were prepared as novel artificial enzyme mimics.They were then decorated by photo-depositing Ag nanoparticles(Ag NPs)on the surface to further improve its catalytic activities.The Ag NPs decorated Co_(3)V_(2)O_(8)(ACVPs)showed both excellent oxidase-and peroxidase-like catalytic activities.They can oxidize the colorless 3,3’,5,5’-tetramethylbenzidine rapidly to induce a blue change.The enhanced enzyme mimetic activities can be attributed to the surface plasma resonance(SPR)effect of Ag NPs as well as the synergistic catalytic effect between Ag NPs and Co_(3)V_(2)O_(8),accelerating electron transfer and promoting the catalytic process.ACVPs were applied in constructing a colorimetric sensor,validating the occurrence of the Fenton reaction,and disinfection,presenting favorable catalytic performance.The enzyme-like catalytic mechanism was studied,indicating the chief role of⋅O_(2)-radicals in the catalytic process.This work not only discovers a novel functional material with double enzyme mimetic activity but also provides a new insight into exploiting artificial enzyme mimics with highly efficient catalytic ability. 展开更多
关键词 Co_(3)V_(2)O_(8) Ag NPs Enzyme mimetic Colorimetric sensor disinfection
下载PDF
Efficacy of graphene nanocomposites for air disinfection in dental clinics: A randomized controlled study
4
作者 Ya-Qiong Ju Xiang-Hua Yu +3 位作者 Jing Wu Ying-Hui Hu Xiang-Yong Han Dan Fang 《World Journal of Clinical Cases》 SCIE 2024年第28期6173-6179,共7页
BACKGROUND Aerosols containing disease-causing microorganisms are produced during oral diagnosis and treatment can cause secondary contamination.AIM To investigate the use of graphene material for air disinfection in ... BACKGROUND Aerosols containing disease-causing microorganisms are produced during oral diagnosis and treatment can cause secondary contamination.AIM To investigate the use of graphene material for air disinfection in dental clinics by leveraging its adsorption and antibacterial properties.METHODS Patients who received ultrasonic cleaning at our hospital from April 2023 to April 2024.They were randomly assigned to three groups(n=20 each):Graphene nanocomposite material suction group(Group A),ordinary filter suction group(Group B),and no air suction device group(Group C).The air quality and air colony count in the clinic rooms were assessed before,during,and after the procedure.Additionally,bacterial colony counts were obtained from the air outlets of the suction devices and the filter screens in Groups A and B.RESULTS Before ultrasonic cleaning,no significant differences in air quality PM2.5 and colony counts were observed among the three groups.However,significant differences in air quality PM2.5 and colony counts were noted among the three groups during ultrasonic cleaning and after ultrasonic treatment.Additionally,the number of colonies on the exhaust port of the suction device and the surface of the filter were significantly lower in Group A than in Group B(P=0.000 and P=0.000,respectively).CONCLUSION Graphene nanocomposites can effectively sterilize the air in dental clinics by exerting their antimicrobial effects and may be used to reduce secondary pollution. 展开更多
关键词 GRAPHENE NANOCOMPOSITES Oral clinic Air disinfection Secondary contamination
下载PDF
Curative effect of hydrogen peroxide combined with silver ion disinfection on pelvic floor dysfunction
5
作者 Wei Zhou Hua Guo 《World Journal of Clinical Cases》 SCIE 2024年第21期4508-4517,共10页
BACKGROUND Pelvic floor dysfunction(PFD)is related to muscle fiber tearing during childbirth,negatively impacting postpartum quality of life of parturient.Appropriate and effective intervention is necessary to promote... BACKGROUND Pelvic floor dysfunction(PFD)is related to muscle fiber tearing during childbirth,negatively impacting postpartum quality of life of parturient.Appropriate and effective intervention is necessary to promote PFD recovery.AIM To analyze the use of hydrogen peroxide and silver ion disinfection for vaginal electrodes in conjunction with comprehensive rehabilitation therapy for postpartum women with PFD.METHODS A total of 59 women with PFD who were admitted to the hospital from May 2019 to July 2022 were divided into two groups:Control group(n=27)received comprehensive rehabilitation therapy and observation group(n=32)received intervention with pelvic floor biostimulation feedback instrument in addition to comprehensive rehabilitation therapy.The vaginal electrodes were disinfected with hydrogen peroxide and silver ion before treatment.Intervention for both groups was started 6 weeks postpartum,and rehabilitation lasted for 3 months.Pelvic floor muscle voltage,pelvic floor muscle strength,vaginal muscle voltage,vaginal muscle tone,pelvic floor function,quality of life,and incidence of postpartum PFD were compared between the two groups.RESULTS Before comprehensive rehabilitation treatment,basic data and pelvic floor function were not significantly different between the two groups.After treatment,the observation group showed significant improvements in the maximum voltage and average voltage of pelvic floor muscles,contraction time of type I and type II fibers,pelvic floor muscle strength,vaginal muscle tone,vaginal muscle voltage,and quality of life(GQOLI-74 reports),compared with the control group.The observation group had lower scores on the pelvic floor distress inventory(PFDI-20)and a lower incidence of postpartum PFD,indicating the effectiveness of the pelvic floor biostimulation feedback instrument in promoting the recovery of maternal pelvic floor function.CONCLUSION The combination of the pelvic floor biostimulation feedback instrument and comprehensive rehabilitation nursing can improve pelvic floor muscle strength,promote the recovery of vaginal muscle tone,and improve pelvic floor function and quality of life.The use of hydrogen peroxide and silver ion disinfectant demonstrated favorable antibacterial efficacy and is worthy of clinical application. 展开更多
关键词 Pelvic floor biostimulation feedback instrument Comprehensive rehabilitation therapy Postpartum pelvic floor dysfunction Vaginal electrode disinfection with hydrogen peroxide and silver ion Nanocolloidal silver
下载PDF
Effect of Different Disinfection Methods on Calluses of Amorphophallus albus P.Y.Liu&J.F.Chen
6
作者 CHEN Xu-yan LU Yi +2 位作者 ZHENG Lin-lin FENG Yu-qian HAO Guo-qian 《Agricultural Science & Technology》 CAS 2024年第2期26-32,共7页
This study aimed to examine the effect of different disinfection methods on the callus of Amorphophallus albus in the tissue culture and rapid propagation system.The calluses induced from buds of A.albus were disinfec... This study aimed to examine the effect of different disinfection methods on the callus of Amorphophallus albus in the tissue culture and rapid propagation system.The calluses induced from buds of A.albus were disinfected with benzalkonium bromide,mercury bichloride,sodium hypochlorite,and ethanol,respectively,for different time periods.The growth of calluses was compared between different treatments and observed in detail by dissection.The results showed that the disinfection with 0.1% mercury bichloride for 5 min and 75% ethanol for 5 s had mild effect on the callus,with the lowest browning rates of 16.32% and 15.46% and the lowest vitrification rates of 3.24% and 9.72%,respectively,after 20 d.The disinfection with benzalkonium bromide and sodium hypochlorite had strong effect on the callus cells,with the lowest browning rate of 50.69% and 25.12% and the lowest vitrification rates of 28.47% and 28.43%,respectively.The cytological observation result showed that the calluses disinfected with ethanol and mercury bichloride showcased compact structures,while those disinfected with sodium hypochlorite and benzalkonium bromide exhibited loose structures.To sum up,it is recommended that 75% ethanol or 0.1% mercury bichloride can be used for disinfection in the tissue culture and rapid propagation of A.albus,while the use of benzalkonium bromide and sodium hypochlorite should be avoided as much as possible. 展开更多
关键词 Amorphophallus albus CALLUS Anatomical observation disinfection methods
下载PDF
Performance Parameters:Demobilization Antibiotic Resistant Bacteria(ARB)and Carrying Genes(ARG)in Wastewater Disinfection
7
作者 Solange Kazue Utimura Denise Crocce Romano Espinosa +2 位作者 Marcio Luís Busi da Silva Elisabete de Santis Braga Pedro Jose Alvarez 《Journal of Environmental Science and Engineering(B)》 2024年第1期1-8,共8页
The UV irradiation is used for removing Antibiotic Resistant Bacteria(ARB)and Antibiotic Resistance Genes(ARG)from wastewater treatment.Bacteriophages are viruses that infect within bacteria,are recognized for bacteri... The UV irradiation is used for removing Antibiotic Resistant Bacteria(ARB)and Antibiotic Resistance Genes(ARG)from wastewater treatment.Bacteriophages are viruses that infect within bacteria,are recognized for bacterial control.The influence of some parameters in quantification and performance influencing of pathogen demobilization could be considered in disinfection of wastewater.The comparison of Polyvalent phage(NE1)versus Coliphage(NE4)in suppressing a bacterium Escherichia coli(NDM-1:b-lactam-resistant)with UV irradiation was observed the efficacy in reduction of cells in the disinfection and parameter process.The results with the effect of UV-C irradiation on NDM-1 infected with 1%of NE4 showed a decrease of cells from 8×10^(6)to 2×10^(5)in 60 min with UV-C dose.The NDM1(E.coli)was infected with 1%of NE4(Polyvalent Phage)under magnetic stirring for 1 h,the cells count was 8×10^(6).After 1 h in UV-C e×posure,the cells number reached 3×10^(5).The NDM1 that was e×posed in 1 h of UV-C irradiation and then was infected with 1%of NE4.Cells counting were done 24 h after this procedure.These cells were e×posed in UV-C and showed a reduction in the number of cells from 1×10^(8)to 4×10^(5)after 60 min.The results indicate that bacteriophages can mitigate bacteria species,and combined the conventional water disinfection technologies that can support the microbial safety control strategies. 展开更多
关键词 Antibiotic Resistant Bacteria(ARB) Antibiotic Resistance Genes(ARG) wastewater treatment disinfection Escherichia coli(E.coli).
下载PDF
Progress in Analytical Methods of Halogenated Disinfection By-Products
8
作者 Jing Wu 《Proceedings of Business and Economic Studies》 2024年第2期95-99,共5页
Ensuring the health and safety of drinking water is crucial for both nations and their citizens.Since the 20th century,the disinfection of drinking water,effectively controlling pathogens in water sources,has become o... Ensuring the health and safety of drinking water is crucial for both nations and their citizens.Since the 20th century,the disinfection of drinking water,effectively controlling pathogens in water sources,has become one of the significant advances in public health.However,the disinfectants used in the process,such as chlorine and chlorine dioxide,react with natural organic matter in the water to produce disinfection by-products(DBPs).Most of these DBPs contain chlorine,and if the source water contains bromine or iodine,brominated or iodinated DBPs,collectively referred to as Halogenated disinfection byproducts(X-DBPs),are formed.Numerous studies have found that X-DBPs pose potential risks to human health and the environment,leading to widespread concern.Mass spectrometry has become an important means of discovering new types of X-DBPs.This paper focuses on the study of methods for analyzing X-DBPs in drinking water using mass spectrometry. 展开更多
关键词 Halogenated disinfection by-products Drinking water High-resolution mass spectrometry
下载PDF
Solar photocatalytic pathogenic disinfection:Fundamentals to state-of-the-art
9
作者 Leena V.Bora 《Water Science and Engineering》 EI CAS CSCD 2023年第2期132-142,共11页
It is necessary to treat pathogen-infected water before its utilisation.Of conventionally used treatment methods,solar photocatalysis has gained considerable momentum owing to its operational simplicity and capacity t... It is necessary to treat pathogen-infected water before its utilisation.Of conventionally used treatment methods,solar photocatalysis has gained considerable momentum owing to its operational simplicity and capacity to use freely and abundantly available solar energy.This article systematically reviewed the disinfection of water with photocatalysis.It addressed the concerns of microbial infection of water and the fundamentals behind its treatment with photocatalysis.It presented an in-depth description of pathogenic deactivation with powerful reactive oxygen species.Special emphasis was given to process intensification as it is an attractive technique that provides multifunctionality and/or equipment miniaturisation.Solar reactor design regarding mobilised/immobilised photocatalysts and compound parabolic concentrators were elucidated.Finally,key parameters governing photoperformance,corresponding trade-offs,and the need for their optimisation were discussed.Overall,this article is a single point of reference for researchers,environmentalists,and industrialists who address the ever-severing challenge of providing clean water whilst also maintaining energy sustainability. 展开更多
关键词 Water Solar light Photocatalysis PATHOGEN E.coli INTENSIFICATION PHOTOREACTOR disinfection
下载PDF
Effectiveness of Disinfection in Bacteriology Laboratories in Togo, 2021
10
作者 Wemboo Afiwa Halatoko Bawimodom Bidjada +10 位作者 Ghislain Emmanuel Sopoh Pirenam Kpaïkpaï Fagdéba David Bara Kokou Akpanta Zoulkarneiri Issa Koffi Akolly Yao Adodo Sadji Gnatoulma Katawa Mounerou Salou Simplice Damintoti Karou Edgard Marius Ouendo 《Open Journal of Preventive Medicine》 2023年第7期213-226,共14页
Background: Laboratory personnel is at risk of biological contamination leading to laboratory-acquired infections (LAIs). The use of disinfection products is essential in the prevention of these infections. This work ... Background: Laboratory personnel is at risk of biological contamination leading to laboratory-acquired infections (LAIs). The use of disinfection products is essential in the prevention of these infections. This work aimed to evaluate the effectiveness of antimicrobial agents used in disinfection in bacteriology laboratories in Togo. Methods: This was a cross-sectional study conducted from June to December 2021 in all bacteriology laboratories in Togo. Swabs taken before and after disinfection of surfaces and staff hands were immediately plated on agar media. Counting and identification of isolated colonies were done after 24 hours of incubation. The ANOVA test was used to compare calculated means, prevalence ratio (PR) and 95% confidence intervals (CI) to compare bacterial frequencies. Results: A total of 393 samples were taken, of which 41.2% were from hands. Before disinfection, surfaces were more contaminated than hands with respectively 40.4% and 29.6% (PR = 1.3;CI 95% = [0.9 - 1.9]). After surface disinfection with 0.5% of chlorine solution, bacterial elimination was total, but partial on hands washed with soap, with residual contamination of 3.7%. A total of 108 strains were isolated before disinfection of which Klebsiella spp. 38.9% and Staphylococcus spp. 25.0%;after disinfection 4 strains were isolated of which: Staphylococcus spp. 75.0% and Klebsiella spp. 25.0%. Conclusion: Surface disinfection was more effective than hand washing with soap and water. We recommend proper hand washing. 展开更多
关键词 EFFECTIVENESS Antimicrobial Agents disinfection HANDS Surfaces
下载PDF
The Application Value of Sanitary Wipes and Medical Alcohol+Gauze Disinfection Method in the Management and Use of Medical Equipment
11
作者 Afen Zheng Chunmei Zhang 《Journal of Clinical and Nursing Research》 2023年第6期162-166,共5页
Objective:To analyze the effect of sanitary wipes and medical alcohol+gauze disinfection methods on the management and use of medical equipment in hospitals.Methods:From February 2023 to August 2023,80 anorectal surge... Objective:To analyze the effect of sanitary wipes and medical alcohol+gauze disinfection methods on the management and use of medical equipment in hospitals.Methods:From February 2023 to August 2023,80 anorectal surgery medical instruments and equipment were randomly sampled as observation samples,and they were grouped using the random number table method(40 instruments in each group).One group was managed with sanitary wipes and medical alcohol+gauze disinfection method(observation group),and the other group was managed with medical alcohol+gauze disinfection method(control group).The degree of contamination on the surface of instruments and equipment and the staff satisfaction of both groups was noted and compared.Results:After cleaning and disinfection,the relative luminescence luminosity(RLU)value of the surface contamination of the sample instruments and equipment decreased significantly(P<0.05);and after cleaning and disinfection,the relative luminescence luminosity(RLU)of the observation group’s instruments and equipment decreased significantly,and the value was lower than that of the control group,(P<0.05);the results of the nursing job satisfaction questionnaire showed that the scores of each survey item in the observation group were higher than those in the control group,(P<0.05).Conclusion:Integrating sanitary wipes and medical alcohol+gauze disinfection method into the management and use of medical equipment not only improves the disinfection of medical instruments but also improves the job satisfaction of nursing staff.Therefore,this method should be popularized. 展开更多
关键词 Medical equipment management Sanitary wipes Medical alcohol Gauze disinfection
下载PDF
Suspended particle effects on ClO_2/ultraviolet light combined disinfection of effluent
12
作者 WANG Jian-ling WANG Bao-zhen +2 位作者 WANG Lin ZHANG Jin-song HUANG Wen-zhang 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2006年第4期634-638,共5页
The concentration of suspended solids of effluent often varies in a wide range, therefore the dose of ultraviolet light (UV) in disinfection process needs to be adjusted to meet the disinfection criterion at a high ... The concentration of suspended solids of effluent often varies in a wide range, therefore the dose of ultraviolet light (UV) in disinfection process needs to be adjusted to meet the disinfection criterion at a high frequency, and the desired disinfection effect is difficult to be ensured. The particles size and particle-associated fecal coliform (F.C.) contribution, and their influence on UV disinfection were investigated when ClO2 and UV combined disinfection process was used. The results showed that suspended solids content had a major impact on UV disinfection efficiency, especially the large particle size fraction. Particles (D〉10μm) associated F. C. were difficult to be disinfected and were the main part of the railings of F.C. inactivation curve. Pre-ClO2 oxidation could reduce the number of particles in effluent, and make large particles decrease to small ones. Therefore, the influence of particles on UV disinfection could be reduced after pre-ClO2 oxidation, and the resistance ability to particle loadings of combined process was enhanced. Moreover, the combined process has a lot of advantages, such as low toxicity, low operational/maintenance costs; it is also convenient to be established in the existing wastewater plant or the new planned one. 展开更多
关键词 effluent disinfection bio-toxicity UV disinfection ClO2/UV combined disinfection
下载PDF
Prevalence and Disinfection of Bacteria Associated with Various Types of Wristbands
13
作者 Joseph Mendonca Belen Wertheimer +4 位作者 Daynalee Dixon Bodhi Stone Karim Dawkins Miranda Christian Nwadiuto Esiobu 《Advances in Infectious Diseases》 2023年第2期193-209,共17页
The potential role of personal items in the transmission of pathogens is poorly understood. In this study, we cultured bacteria of public health importance found on wristbands, determined whether there is a correlatio... The potential role of personal items in the transmission of pathogens is poorly understood. In this study, we cultured bacteria of public health importance found on wristbands, determined whether there is a correlation between wristband material and prevalence, and tested three household disinfectants for efficacy in reducing bacteria on wristbands made of plastic, rubber, metal, and cloth, using standard microbiological assays. Total cultivable bacteria, Staphylococci, Enterobacteria (Escherichia coli), and Pseudomonas on 20 smartwatch wristbands were cultured from randomly recruited subjects. Nearly all wristbands (95%) were contaminated, with the highest average numbers of 3.46E+4 cfu/cm<sup>2</sup> and 1.52E+4 cfu/cm<sup>2</sup> on rubber and plastic bands respectively. Metallic gold and silver wristbands had zero to 18 cfu/cm<sup>2</sup>. While the high prevalence of Staphylococcus spp (85% of wristbands)—skin microbiota;was not unexpected, the occurrence of Pseudomonas spp (30%), and enteric bacteria (60%), even at relatively low numbers is of public health significance. Bacterial load on individual subjects varied remarkably with males and females harboring average total bacteria of 4.045 and 3.42 log<sub>10</sub>cfu/cm<sup>2</sup> of wristband, respectively. The most important predictor of wristband bacteria load was the texture of wristband material and activity (hygiene) of the subject at sampling time. Potential pathogens—Staphylococcus aureus (8143 cfu/cm<sup>2</sup>) and Pseudomonas spp. (1126 cfu/cm<sup>2</sup>) were most abundant on cloth and rubber wristbands, respectively, while the presence of the E. coli group was associated with animal handling activity by a veterinarian. Lysol Disinfectant Spray and 70% Ethanol were highly effective regardless of wristband material with >99.99% kill rate and a log cfu/cm<sup>2</sup> reduction of 3 - 4.0 and 3 - 4.5 respectively within 30 seconds. Apple Cider Vinegar (ACV) was not as potent. Only 2 - 3.5 log cfu/cm<sup>2</sup> drop was obtained after 120 seconds of exposure. Further susceptibility assays with standard reference bacteria showed that Lysol and 70% alcohol effectively killed > 99.99% (>8 log CFU drop) of Escherichia coli strain 7001, Staphylococcus aureus strain 6538, and Pseudomonas aeruginosa strain 10662 within 30 seconds of contact. Vinegar had a similar efficacy on the gram negatives but little or no effect on Staph aureus (only a 2-log CFU/ml reduction in 5 minutes!) The high prevalence of potential pathogens, some of which could be reservoirs of antibiotic resistance reveals a weak link in infection control and underscores the need for regular cleaning of personal and hand-held accessories with adequate considerations of their texture. 展开更多
关键词 Apple Cider Vinegar DISINFECTANTS Escherichia coli Lysol Pseudomonas aeruginosa Public Health Staphylococcus aureus Wristbands
下载PDF
Waste Water Disinfection During SARS Epidemic for Microbiological and Toxicological Control 被引量:5
14
作者 CHAO CHEN XIAO-JIAN ZHANG YUN WANG LING-XIA ZHU JING LIU 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2006年第3期173-178,共6页
Objective To evaluate the disinfection of wastewater in China. Methods During the SARS epidemic occurred in Beijing, a study of different disinfection methods used in the main local wastewater plants including means o... Objective To evaluate the disinfection of wastewater in China. Methods During the SARS epidemic occurred in Beijing, a study of different disinfection methods used in the main local wastewater plants including means of chlorine, chlorine dioxide, ozone, and ultraviolet was carried out in our laboratory. The residual coliform, bacteria and trihalomethanes, haloacetic acids were determined after disinfection. Results Chlorine had fairly better efficiency on microorganism inactivation than chlorine dioxide with the same dosage. Formation of THMs and HAAs does not exceed the drinking water standard. UV irradiation had good efficiency on microorganism inactivation and good future of application in China. Organic material and ammonia nitrogen was found to be significant on inactivation and DBPs formation. Conclusion Chlorine disinfection seems to be the best available technology for coliform and bacteria inactivation. And it is of fairly low toxicological hazard due to the transformation of monochloramine. 展开更多
关键词 Wastewater disinfection Chlorine Chlorine dioxide Ozone Ultraviolet disinfection by-products
下载PDF
Simultaneous Control of Microorganisms and Disinfection By-products by Sequential Chlorination 被引量:4
15
作者 CHAO CHEN XIAO-JIAN ZHANG +1 位作者 WEN-JIE HE HONG-DA HAN 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2007年第2期119-125,共7页
Objective To introduce a new sequential chlorination disinfection process in which short-term free chlorine and chloramine are sequentially added. Methods Pilot tests of this sequential chlorination were carried out i... Objective To introduce a new sequential chlorination disinfection process in which short-term free chlorine and chloramine are sequentially added. Methods Pilot tests of this sequential chlorination were carried out in a drinking water plant. Results The sequential chlorination disinfection process had the same or better efficiency on microbe (including virus) inactivation compared with the free chlorine disinfection process. There seemed to be some synergetic disinfection effect between free chlorine and monochloramine because they attacked different targets. The sequential chlorination disinfection process resulted in 35.7%-77.0% TTHM formation and 36.6%-54.8% THAA5 formation less than the free chlorination process. The poorer the water quality was, the more advantage the sequential chlorination disinfection had over the free chlorination. Conclusion This process takes advantages of free chlorine's quick inactivation of microorganisms and chloramine's low disinfection by-product (DBP) yield and long-term residual effect, allowing simultaneous control of microbes and DBPs in an effective and economic way. 展开更多
关键词 disinfection Free chlorine CHLORAMINE disinfection by-products MICROORGANISMS
下载PDF
Effect of Disinfection Time on Microbial Content and Quality of Cold Fresh Chicken
16
作者 王合叶 赵永富 冯敏 《Agricultural Science & Technology》 CAS 2017年第3期476-477,489,共3页
[Objective] The aim was to provide reference for the production technolo- gy of cold fresh chicken. [Method] Lactic acid was used as the disinfectant in cooling water, so as to study the effect of disinfection time on... [Objective] The aim was to provide reference for the production technolo- gy of cold fresh chicken. [Method] Lactic acid was used as the disinfectant in cooling water, so as to study the effect of disinfection time on the microbial content and quality of cold fresh chicken. [Result] With disinfection of 20 min, the removal rates of the total colonies, coliforms and moulds reached over 95%. As the disinfec- tion time was further extended, it had no significant effect on the removal effects of the microbial content and could affect the tenderness and color of cold fresh chick- en. [Cendusion] The study provides references for the design and optimization of the production process of cold fresh chicken. 展开更多
关键词 Cold fresh chicken disinfection time Total Colonies COLIFORMS MOULDS Meat Tenderness
下载PDF
Design of Water Disinfection Scheme for Rural Drinking Water Safety Project 被引量:1
17
作者 Qing Lu 《Meteorological and Environmental Research》 CAS 2013年第7期28-31,共4页
As further promotion of the rural drinking water safety project in whole country, small villages in vast countryside have been or will be equipped with safety drinking water project. We analyzed necessity of the rural... As further promotion of the rural drinking water safety project in whole country, small villages in vast countryside have been or will be equipped with safety drinking water project. We analyzed necessity of the rural drinking water disinfection, discussed disinfection method suitable for rural drinking water characteristics, and put forward disinfection schemes for different water supply sources. 展开更多
关键词 Rural drinking water safety project disinfection method disinfection scheme China
下载PDF
Disinfection Kinetics and Contribution of Reactive Oxygen Species When Eliminating Bacteria with TiO_(2) Induced Photocatalysis 被引量:4
18
作者 Yanling Cai Maria Stromme Ken Welch 《Journal of Biomaterials and Nanobiotechnology》 2014年第3期200-209,共10页
Titania (TiO2) induced photocatalysis has been widely investigated and applied as a disinfection strategy in many industrial and clinical applications. Reactive oxygen species (ROS), including hydroxyl radicals (&... Titania (TiO2) induced photocatalysis has been widely investigated and applied as a disinfection strategy in many industrial and clinical applications. Reactive oxygen species (ROS), including hydroxyl radicals (&8226OH), superoxide radicals () and hydrogen peroxide (H2O2), generated in the photocatalytic reaction process are considered to be the active components prompting the bactericidal effect. In the present work, the kinetics of photocatalytic inactivation of Staphylococcus epidermidis and specific contributions of &#8226OH, and H2O2 to the bactericidal process were studied using two disinfection settings sutilizing photocatalytic resin-TiO2 nanocomposite surfaces and suspended TiO2 nanoparticles, respectively. In antibacterial tests against S. epidermidis with a layer of bacterial suspension on the resin-TiO2 surfaces, H2O2 was found to be the most efficient ROS component contributing to the antibacterial effect. Disinfection kinetics showed a two-step behavior with an initial region having a lower disinfection rate followed by a higher rate region after 10 min of UV irradiation. By contrast, in antibacterial tests with suspended bacteria and photocatalytic TiO2 nanoparticles, &#8226OH and H2O2 showed equal significance in the bacterial inactivation having a typical Chick-Watson disinfection kinetics behavior with a steady disinfection rate. The results contribute to the understanding of the bactericidal mechanism and kinetics of photocatalytic disinfection that are essential for designing specific antibacterial applications of photocatalytic materials. 展开更多
关键词 Photocatalytic disinfection TiO_(2) Reactive Oxygen Species(ROS) disinfection Kinetics
下载PDF
Impact of Suspended Particles and Enhancement Techniques on Ultraviolet Disinfection of a Secondary Effluent
19
作者 WANG Jianling WANG Lin +2 位作者 WANG Baozhen ZHANG Jinsong ZOU Oixian 《Journal of Ocean University of China》 SCIE CAS 2006年第4期381-386,共6页
The concentration of suspended solids in the secondary effluent often varies widely, leading to frequent adjustment of the UV dosage to meet the disinfection criterion. In addition, a desired disinfection rate is diff... The concentration of suspended solids in the secondary effluent often varies widely, leading to frequent adjustment of the UV dosage to meet the disinfection criterion. In addition, a desired disinfection rate is difficult to achieve sometimes. The authors studied the particle size distribution, contribution of particle-associated Fecal Coliform (F.C.), and their influences on UV disinfection. A combined disinfection process (chlorination with a subsequent UV disinfection) was tested to improve the disinfection effect. The results indicated that the content of suspended solids, especially that of large particles, has a strong impact on UV disinfection efficiency; D>10 μm particles associated F.C. are difficult to be disinfected and are the main part of the tailings of F.C. inactivation curves. Pre-chlorination could decrease the number of particles in the secondary effluent and transform the large particles into small ones, reducing the influence of particles on UV disinfection and enhancing the resistance ability of the combined process to particle loading. 展开更多
关键词 effluent disinfection biotoxicity Chlorination/UV combined disinfection
下载PDF
Characterization of dissolved organic matter fractions and its relationship with the disinfection by-product formation 被引量:13
20
作者 ZHANG Hua QU Jiuhui +1 位作者 LIU Huijuan WEI Dongbin 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2009年第1期54-61,共8页
Dissolved organic matter (DOM) has been identified as precursor for disinfection by-products (DBPs) formation during chlorination. Recently, it has been demonstrated that the characteristics of DOM influence the D... Dissolved organic matter (DOM) has been identified as precursor for disinfection by-products (DBPs) formation during chlorination. Recently, it has been demonstrated that the characteristics of DOM influence the DBPs formation mechanism. A study was, therefore, initiated to investigate the effects of DOM fractions on DBPs formation mechanism. In the chlorination process, organic acids are dominant precursors of total thihalomethanes (TTHM) because of the vc-o and unsaturated structures. Furthermore, the TTHM formation of organic acids was affected by pH more greatly. Based on the fluorescence spectroscopy analysis, DOM fractions contained several fluorescence substances. During chlorination, humic acid-like substances were found to exhibit high chlorine reactivity and hydrophobic organics decomposed to smaller molecules faster than hydrophilic organics even at lower chlorine dosages. Unlike hydrophobic fractions, hydrophilic organics showed no toxicity following chlorination, suggesting that the toxic structures in hydrophihc organics showed high chlorine reactivity during chlorination. 展开更多
关键词 disinfection by-products CHLORINATION CHARACTERISTICS dissolved organic matter
下载PDF
上一页 1 2 19 下一页 到第
使用帮助 返回顶部