Si-PIN photodetectors having features such as low cost,small size,low weight,low voltage,and low power consumption are widely used as radiation detectors in electronic personal dosimeters(EPDs).The technical parameter...Si-PIN photodetectors having features such as low cost,small size,low weight,low voltage,and low power consumption are widely used as radiation detectors in electronic personal dosimeters(EPDs).The technical parameters of EPDs based on the Si-PIN photodetectors include photon energy response(PER),angular response,inherent error,and dose rate linearity.Among them,PER is a key parameter for evaluation of EPD measurement accuracy.At present,owing to the limitations of volume,power consumption,and EPD cost,the PER is usually corrected by a combination of single-channel counting techniques and filtering material methods.However,the above-mentioned methods have problems such as poor PER and low measurement accuracy.To solve such problems,in this study,a 1024-channel spectrometry system using a Si-PIN photodetector was developed and fullspectrum measurement in the reference radiation fields was conducted for radiation protection.The measurement results using the few-channel spectroscopy dose method showed that the PER could be controlled within±14%and±2%under the conditions of two and three energy intervals,respectively,with different channel numbers.The PER measured at 0°angle of radiation incidence meets the-29%to+67%requirements of IEC 61526:2010.Meanwhile,the channel number and counts-to-dose conversion factors formed in the experiment can be integrated into an EPD.展开更多
Since the room-temperature detector CdZnTe(CZT) has advantages in terms of detection efficiency,energy resolution, and size, it has been extensively used to detect X-rays and gamma-rays. So far, nuclear radiation dete...Since the room-temperature detector CdZnTe(CZT) has advantages in terms of detection efficiency,energy resolution, and size, it has been extensively used to detect X-rays and gamma-rays. So far, nuclear radiation detectors such as cerium chloride doped with lanthanum bromide(LaBr_3(Ce)), thallium doped with cesium iodide(sI(Tl)), thallium doped with sodium iodide(NaI(Tl)),and high-purity germanium(HPGe) primarily use the spectroscopy-dose rate function(G(E)) to achieve the accurate measurement of air kerma rate(K_a) and ambient dose equivalent rate(H*(10)). However, the spectroscopy-dose rate function has been rarely measured for a CZT detector. In this study, we performed spectrum measurement using a hemispherical CZT detector in a radiation protection standards laboratory. The spectroscopy-dose rate function G(E) of the CZT detector was calculated using the least-squares method combined with the standard dose rate at the measurement position. The results showed that the hemispherical CZT detector could complete the measurement of air kerma rate(K_a) and ambient dose equivalent rate(H*(10)) by using the G(E) function at energies between 48 keV and 1.25 MeV, and the relative intrinsic errors were, respectively, controlled within ± 2. 3 and ± 2. 1%.展开更多
During 1991-1993, the radioactivity levels of the bone-coal mines were investigated in Hubei, Hunan, Ji-angxi, Zhejiang and Anhui Provinces, respectively, where the reserve of bone-coal is about 90% of our country’s ...During 1991-1993, the radioactivity levels of the bone-coal mines were investigated in Hubei, Hunan, Ji-angxi, Zhejiang and Anhui Provinces, respectively, where the reserve of bone-coal is about 90% of our country’s total reserve. The annual additional collective dose equivalent within 80km evaluated region of bone-coal power stations in Nijiangkou and Anren is 1.7 and 1.9 man·mSv, respectively, and that of Zhuantanyan bone-coal shaft is 1.4 man·mSv. The collective dose equivalent caused by bone-coal cinder brick produced for 25 years in the five prov-inces is 1.6×105 man Sv.展开更多
Oxidative stress has been associated with a number of physiological problems in swine,including reduced production efficiency.Recently,although there has been increased research into regulatory mechanisms and antioxid...Oxidative stress has been associated with a number of physiological problems in swine,including reduced production efficiency.Recently,although there has been increased research into regulatory mechanisms and antioxidant strategies in relation to oxidative stress-induced pig production,it remains so far largely unsuccessful to develop accurate models and nutritional strategies for specific oxidative stress factors.Here,we discuss the dose and dose intensity of the causes of oxidative stress involving physiological,environmental and dietary factors,recent research models and the antioxidant strategies to provide theoretical guidance for future oxidative stress research in swine.展开更多
Timer error as well as its convention is very important for dose accuracy during irradiation. This paper determines the timer error of irradiators at Secondary Standard Dosimetry Laboratory (SSDL) in Nigeria. The irra...Timer error as well as its convention is very important for dose accuracy during irradiation. This paper determines the timer error of irradiators at Secondary Standard Dosimetry Laboratory (SSDL) in Nigeria. The irradiators are Cs-137 OB6 irradiator and X-ray irradiators at the Protection level SSDL;and Co-60 irradiator at the Therapy Level SSDL. PTW UNIDOS electrometer and LS01 Ionization chamber were used at the Protection Level to obtain doses for both Cs-137 OB6 and X-ray irradiators while an IBA farmer type ionization chamber and an IBA DOSE 1 electrometer were used at the Protection Level SSDL. Single/multiple exposure method and graphical method were used in the determination of the timer error for the three irradiators. The timer error obtained for Cs-137 OB6 irradiator was 0.48 ± 0.01 s, the timer error for the X-ray irradiator was 0.09 ± 0.01 s while the timer error obtained for GammaBeam X200 was 1.21 ± 0.04 s. It was observed that the timer error is not affected by source to detector distance. It was also observed that the timer error of Co-60 Gamma X200 irradiator is increasing with the age of the machine. Source to detector distance and field size do not contribute towards the timer error of the irradiators. The timer error of the Co-60 Gamma X200 irradiator (the only irradiator among the irradiators with a pneumatic system) increases with the age of the irradiator.展开更多
X-ray excited photodynamic therapy(X-PDT)is the bravo answer of photodynamic therapy(PDT)for deep-seated tumors,as it employs X-ray as the irradiation source to overcome the limitation of light penetration depth.Howev...X-ray excited photodynamic therapy(X-PDT)is the bravo answer of photodynamic therapy(PDT)for deep-seated tumors,as it employs X-ray as the irradiation source to overcome the limitation of light penetration depth.However,high X-ray irradiation dose caused organ lesions and side effects became the major barrier to X-PDT application.To address this issue,this work employed a classic-al co-precipitation reaction to synthesize NaLuF_(4):15%Tb^(3+)(NLF)with an average particle size of(23.48±0.91)nm,which was then coupled with the photosensitizer merocyanine 540(MC540)to form the X-PDT system NLF-MC540 with high production of singlet oxygen.The system could induce antitumor efficacy to about 24%in relative low dose X-ray irradiation range(0.1-0.3 Gy).In vivo,when NLF-MC540 irradiated by 0.1 Gy X-ray,the tumor inhibition percentage reached 89.5%±5.7%.The therapeutic mechanism of low dose X-PDT was found.A significant increase of neutrophils in serum was found on the third day after X-PDT.By immunohistochemical staining of tumor sections,the Ly6G^(+),CD8^(+),and CD11c^(+)cells infiltrated in the tumor microenvironment were studied.Utilizing the bilat-eral tumor model,the NLF-MC540 with 0.1 Gy X-ray irradiation could inhibit both the primary tumor and the distant tumor growth.De-tected by enzyme linked immunosorbent assay(ELISA),two cytokines IFN-γand TNF-αin serum were upregulated 7 and 6 times than negative control,respectively.Detected by enzyme linked immune spot assay(ELISPOT),the number of immune cells attributable to the IFN-γand TNF-αlevels in the group of low dose X-PDT were 14 and 6 times greater than that in the negative control group,respectively.Thus,it conclude that low dose X-PDT system could successfully upregulate the levels of immune cells,stimulate the secretion of cy-tokines(especially IFN-γand TNF-α),activate antitumor immunity,and finally inhibit colon tumor growth.展开更多
With the development of ultra-wide coverage technology,multibeam echo-sounder(MBES)system has put forward higher requirements for localization accuracy and computational efficiency of ray tracing method.The classical ...With the development of ultra-wide coverage technology,multibeam echo-sounder(MBES)system has put forward higher requirements for localization accuracy and computational efficiency of ray tracing method.The classical equivalent sound speed profile(ESSP)method replaces the measured sound velocity profile(SVP)with a simple constant gradient SVP,reducing the computational workload of beam positioning.However,in deep-sea environment,the depth measurement error of this method rapidly increases from the central beam to the edge beam.By analyzing the positioning error of the ESSP method at edge beam,it is discovered that the positioning error increases monotonically with the incident angle,and the relationship between them could be expressed by polynomial function.Therefore,an error correction algorithm based on polynomial fitting is obtained.The simulation experiment conducted on an inclined seafloor shows that the proposed algorithm exhibits comparable efficiency to the original ESSP method,while significantly improving bathymetry accuracy by nearly eight times in the edge beam.展开更多
In this editorial I comment on the article,published in the current issue of the World Journal of Clinical Oncology.Primary central nervous system lymphoma(PCNSL)is a disease of elderly and immunocompromised patients....In this editorial I comment on the article,published in the current issue of the World Journal of Clinical Oncology.Primary central nervous system lymphoma(PCNSL)is a disease of elderly and immunocompromised patients.The authors reported clinical results of 19 patients with PCNSL treated with zanubrutinib/high dose methotrexate(HD-MTX)until disease progression.They demonstrated that the combination of zanubrutinib with HD-MTX led to a marked clinical response and tolerability among these patients.They also observed that cerebrospinal fluid liquid biopsy to detect circulating tumor DNA may be a good option for evaluating treatment response and tumor burden in patients with PCNSL.PCNSL is a challenging disease for treatment as these patients present with different neurological states and comorbidities.Treatment has evolved over the years from whole brain radiotherapy to HD-MTX followed by autologous stem cell transplant.Gradually,treatment of patients with PCNSL is going to become individualized.展开更多
Objective:The study aimed to explore the characteristic of dose equivalent rates(DERs)of photon and neutron outside the treatment room under high-energy electron mode(dose rate 1000 MU/min)of linac and to evaluate the...Objective:The study aimed to explore the characteristic of dose equivalent rates(DERs)of photon and neutron outside the treatment room under high-energy electron mode(dose rate 1000 MU/min)of linac and to evaluate the effectiveness of treatment room protection.Methods:A 451 P pressurized ion chamber and a thermo neutron detector were used to measure the DERs of the photon and neutron at selected points.The effects of field size,applicator size,applicator,anthropomorphic phantom(CDP)and lead block on DER were investigated respectively.Results:The DERs of a photon at the center of shielding door(point A),control console(point B),primary shielding walls(point C,D)and roof of treatment room(point E)increased with increasing electron energy,but decreased with the increasing field size.The DERs of a photons at points A and B are smaller than 2.5μSv/h for all scenarios,while those at point D greater than 2.5μSv/h when irradiated by 18-22 Me V electron.In addition,CDP may change the DERs of a photon at points C and D about 5% to 30%.On the other hand,the DERs of neutron increase with increasing electron energy but decrease with the increase of field size and applicator size,however,the lead block and the applicator itself will change the DERs of leak neutron at point A,but its amplitude is less than 0.5μSv/h.The maximum DER of neutron at point A is 6.18μSv/h irradiated by 22 Me V electron.For other scenarios,they are all in the range of national standards limits.Conclusion:The DERs of a photon and neutron outside the treatment room mainly depend on the energy,field size and irradiation direction of the electron beam.If high-energy 18 Me V and 22 Me V electron beams will be used,the primary shielding walls and shielding doors need reconstructing or increasing thickness.展开更多
Objective This study aims to investigate the dosimetric differences among four planning methods of physical and biological optimization in hypofractionated radiation therapy for non-small cell lung cancer(NSCLC).Metho...Objective This study aims to investigate the dosimetric differences among four planning methods of physical and biological optimization in hypofractionated radiation therapy for non-small cell lung cancer(NSCLC).Methods Ten NSCLC patients receiving radiation therapy were chosen for this retrospective study.Volumetric modulated arc treatment plans for each patient were remade with dose-volume(DV)functions,biological-physical functions,and biological functions,using the same constraint parameters during optimization.The dosimetric differences between the four types of plans were calculated and analyzed.Results For the target,equivalent uniform dose(EUD)of the EUD and EUD+DV groups was approximately 2.8%–3.6%and 3.2%–3.7%higher than those of the DV and DV+EUD groups,respectively.The average tumor control probability(TCP)of the EUD and EUD+DV groups was also significantly higher than those of the other two groups(P<0.05).The difference in heterogeneity index(HI)among the four groups was also statistically significant(P<0.05),while the difference of conformity index(CI)was not significant(P>0.05).For the organs at risk,the differences of EUD,V5,V10,V20,V30 of normal lung tissues were not statistically significant(P>0.05);however,the mean lung dose of the EUD and EUD+DV groups was slightly lower than those of the other two groups.Conclusion The biological optimization method has obvious advantages of improving EUD and TCP of the target,while decreasing the exposed dose of normal lung.This result is meaningful in choosing plan optimization methods in routine work.展开更多
Radioactivity is a natural phenomenon present in the universe. So, because of human life solidarity with a habitat, we are permanently in contact, especially through building materials. The objective of this work is t...Radioactivity is a natural phenomenon present in the universe. So, because of human life solidarity with a habitat, we are permanently in contact, especially through building materials. The objective of this work is the determination of the used cement radioactivity level in the buildings in Cote d'Ivoire. Thus, samples of grey and white cement currently used on Ivorian territory were taken. In order to determine the radioactivity level of this cement, samples were analyzed by using gamma spectrometry chain which contains a NaI (Tl) scintillation detector designed by the German manufacturer LD-DIDACTIC, coupled to a multichannel analyzer (AMC) using a Cassy Lab software. Thus, the specific activity of the primordial radionuclides 226Ra, 232Th and 40K, was able to be determined. The average values obtained are 29.66 Bq/kg, 34.88 Bq/kg and 178.424 Bq/kg respectively for 226Ra, 232Th and 40K. All average values are below the limit values recommended by UNSCEAR. However, we evaluated the radiological parameters such as the equivalent radium activity and the annual effective dose in order to translate the specific activity in terms of harmfulness. Values obtained for these parameters are below those recommended by ICRP and UNSCEAR. These results show that the risk incurred by the use of these different brands of cement is low.展开更多
In recent years,graphics processing units(GPUs)have been applied to accelerate Monte Carlo(MC)simulations for proton dose calculation in radiotherapy.Nonetheless,current GPU platforms,such as Compute Unified Device Ar...In recent years,graphics processing units(GPUs)have been applied to accelerate Monte Carlo(MC)simulations for proton dose calculation in radiotherapy.Nonetheless,current GPU platforms,such as Compute Unified Device Architecture(CUDA)and Open Computing Language(OpenCL),suffer from cross-platform limitation or relatively high programming barrier.However,the Taichi toolkit,which was developed to overcome these difficulties,has been successfully applied to high-performance numerical computations.Based on the class II condensed history simulation scheme with various proton-nucleus interactions,we developed a GPU-accelerated MC engine for proton transport using the Taichi toolkit.Dose distributions in homogeneous and heterogeneous geometries were calculated for 110,160,and 200 MeV protons and were compared with those obtained by full MC simulations using TOPAS.The gamma passing rates were greater than 0.99 and 0.95 with criteria of 2 mm,2%and 1 mm,1%,respectively,in all the benchmark tests.Moreover,the calculation speed was at least 5800 times faster than that of TOPAS,and the number of lines of code was approximately 10 times less than those of CUDA or OpenCL.Our study provides a highly accurate,efficient,and easy-to-use proton dose calculation engine for fast prototyping,beamlet calculation,and education purposes.展开更多
The secondary neutron fields at the deep tumor therapy terminal at HIRFL(Heavy Ion Research Facility in Lanzhou) were investigated. The distributions of neutron ambient dose equivalent were measured with a FHT762Wendi...The secondary neutron fields at the deep tumor therapy terminal at HIRFL(Heavy Ion Research Facility in Lanzhou) were investigated. The distributions of neutron ambient dose equivalent were measured with a FHT762Wendi-II neutron ambient dose equivalent meter as ^(12)C ions with energies of 165, 207, 270, and 350 Me V/u were bombarded on thick tissue-like targets. The thickness of targets used in the experiments was larger than the range of the carbon ions. The neutron spectra and dose equivalent were simulated by using FLUKA code, and the results agree well with the experimental data. The experiment results showed that the neutron dose produced by fragmentation reactions in tissue can be neglected in carbon-ion therapy, even considering their enhanced biological effectiveness.These results are also valuable for radiation protection, especially in the shielding design of high energy heavy ion medical machines.展开更多
Compton camera-based prompt gamma(PG) imaging has been proposed for range verification during proton therapy. However, a deviation between the PG and dose distributions, as well as the difference between the reconstru...Compton camera-based prompt gamma(PG) imaging has been proposed for range verification during proton therapy. However, a deviation between the PG and dose distributions, as well as the difference between the reconstructed PG and exact values, limit the effectiveness of the approach in accurate range monitoring during clinical applications. The aim of the study was to realize a PG-based dose reconstruction with a Compton camera, thereby further improving the prediction accuracy of in vivo range verification and providing a novel method for beam monitoring during proton therapy. In this paper, we present an approach based on a subset-driven origin ensemble with resolution recovery and a double evolutionary algorithm to reconstruct the dose depth profile(DDP) from the gamma events obtained by a cadmium-zinc-telluride Compton camera with limited position and energy resolution. Simulations of proton pencil beams with clinical particle rate irradiating phantoms made of different materials and the CT-based thoracic phantom were used to evaluate the feasibility of the proposed method. The results show that for the monoenergetic proton pencil beam irradiating homogeneous-material box phantom,the accuracy of the reconstructed DDP was within 0.3 mm for range prediction and within 5.2% for dose prediction. In particular, for 1.6-Gy irradiation in the therapy simulation of thoracic tumors, the range deviation of the reconstructed spreadout Bragg peak was within 0.8 mm, and the relative dose deviation in the peak area was less than 7% compared to the exact values. The results demonstrate the potential and feasibility of the proposed method in future Compton-based accurate dose reconstruction and range verification during proton therapy.展开更多
Active disturbance-rejection methods are effective in estimating and rejecting disturbances in both transient and steady-state responses.This paper presents a deep observation on and a comparison between two of those ...Active disturbance-rejection methods are effective in estimating and rejecting disturbances in both transient and steady-state responses.This paper presents a deep observation on and a comparison between two of those methods:the generalized extended-state observer(GESO)and the equivalent input disturbance(EID)from assumptions,system configurations,stability conditions,system design,disturbance-rejection performance,and extensibility.A time-domain index is introduced to assess the disturbance-rejection performance.A detailed observation of disturbance-suppression mechanisms reveals the superiority of the EID approach over the GESO method.A comparison between these two methods shows that assumptions on disturbances are more practical and the adjustment of disturbance-rejection performance is easier for the EID approach than for the GESO method.展开更多
Objective:To assess the clinical outcomes and toxicities of once daily(QD)simultaneous dose reduction intensity-modulated radiotherapy(SDR-IMRT-QD;SDR-QD)versus conventional QD IMRT(C-QD)and twice daily(BID)IMRT in pa...Objective:To assess the clinical outcomes and toxicities of once daily(QD)simultaneous dose reduction intensity-modulated radiotherapy(SDR-IMRT-QD;SDR-QD)versus conventional QD IMRT(C-QD)and twice daily(BID)IMRT in patients with limited-stage small cell lung cancer(LS-SCLC).Methods:After propensity score matching(PSM),a retrospective analysis involving 300 patients with LS-SCLC treated using SDR-QD,C-QD,or BID was performed from January 1,2014 to December 31,2019.The prescribed irradiation dose in the SDR-QD cohort was 60 Gy/PGTV and 54 Gy/PTV QD.The radiation dose was 60 Gy for both PGTV and PTV QD in the C-QD cohort.The radiation dose was 45 Gy for both PGTV and PTV in the BID cohort.Toxicities,short-term effects,and survival outcomes were recorded.A meta-analysis on the protective effects of pharmaceuticals for cardiac toxicities induced by anti-tumor therapy was performed.Results:The median overall survival time(MST)in the 3 cohorts were 32.7 months(SDR-QD),26.3 months(C-QD),and 33.6 months(BID);the differences between groups were statistically significant.Lower toxicities and doses to organs-at-risk(OARs)occurred in the SDR-QD and BID cohorts.Further,the cardiac dose dosimetric parameter Vheart40 was negatively associated with survival(r=-0.35,P=0.007).A Vheart40 value of 16.5%was recommended as a cut-off point,which yielded 54.7%sensitivity and 85.7%specificity for predicting negative survival outcomes.The meta-analysis indicated that pharmaceuticals significantly reduced the cardiac toxicities induced by chemotherapy,but not radiotherapy.Conclusions:SDR-QD was shown to have similar toxicities and survival compared with BID,but fewer toxicities and better survival than C-QD.In addition,cardiac dose exposure was negatively associated with survival.Thus,16.5%of the cardiac dosimetric parameter Vheart40 is recommended as the cut-off point,and a Vheart40>16.5%predicts poor survival.展开更多
Introduction: Measles is a viral disease that is a major public health problem in both developed and developing countries. It is a contagious disease resulting from infection with the measles virus and is still respon...Introduction: Measles is a viral disease that is a major public health problem in both developed and developing countries. It is a contagious disease resulting from infection with the measles virus and is still responsible for more than 100,000 deaths per year. Although vaccination is one of the most successful and cost-effective public health interventions to reduce mortality and morbidity, approximately 1.4 million children worldwide die from vaccine-preventable diseases each year. In Zambia, MCV2 was 66% below WHO recommended target of 95%. This study therefore assessed the acceptability of second dose measles vaccination services among caretakers/mothers with children less than two years of age in Livingstone, Zambia. Methods: The study used analytical cross-sectional study design. A logistic regression analysis was performed to identify factors associated with acceptability of the second dose of measles vaccine. A semi structured questionnaire was administered to collect data on socio demographic characteristics and factors related to acceptability of the second dose of measles vaccine. SPSS version 26.0 was used for descriptive and inferential analysis at 5% level of significance. Results: There was no statistically significant difference in acceptability of the second dose of measles vaccine by gender, marital status, type of employment, income level, socio-cultural and traditional beliefs, and education level. However, there was a statistically significant difference in acceptability of the second dose of measles vaccine by knowledge level of second dose of measles vaccine. A Chi square test result indicated that second dose acceptability was higher with less children than that of respondents with many children (χ2(5) = 15.3, p and knowledge levels (χ2(2) = 14.8, p Changes in knowledge level from medium to high reduced the odds of second dose measles vaccine acceptability. Furthermore, this study showed that acceptance of the second measles vaccination increased from mothers/caretakers with low knowledge (3.6%) to medium knowledge (13.3%) and finally high knowledge (83.1%). Conclusion: Tailored messaging to increase knowledge among mothers and caregivers on the importance of the second dose of measles vaccine is critical in improving acceptability. Therefore, the researchers recommend that the health providers should continue to raise awareness associated with the low acceptability of the second dose of measles vaccine and improve on child preventable diseases such as measles.展开更多
Monte Carlo simulations are frequently utilized in radiation dose assessments.However,many researchers find the prevailing computing platforms to be intricate.This highlights a pressing need for a specialized framewor...Monte Carlo simulations are frequently utilized in radiation dose assessments.However,many researchers find the prevailing computing platforms to be intricate.This highlights a pressing need for a specialized framework for phantom dose evalua-tion.To address this gap,we developed a user-friendly radiation dose assessment platform using the Monte Carlo toolkit,Geant4.The Tsinghua University Phantom Dose(THUDosePD)augments the flexibility of Monte Carlo simulations in dosi-metric research.Originating from THUDose,a code with generic,functional,and application layers,THUDosePD focuses predominantly on anatomical phantom dose assessment.Additionally,it enables medical exposure simulation,intricate geometry creation,and supports both three-dimensional radiation dose analysis and phantom format transformations.The system operates on a multi-threaded parallel CPU architecture,with some modules enhanced for GPU parallel computing.Benchmark tests on the ICRP reference male illustrated the capabilities of THUDosePD in phantom dose assessment,covering the effective dose,three-dimensional dose distribution,and three-dimensional organ dose.We also conducted a voxelization conversion on the polygon mesh phantom,demonstrating the method’s efficiency and consistency.Extended applications based on THUDosePD further underline its broad adaptability.This intuitive,three-dimensional platform stands out as a valuable tool for phantom radiation dosimetry research.展开更多
基金This work was partly supported by the National Key Scientific Instruments to Develop Dedicated Program(Nos.2013YQ090811 and 2016YFF0103800)the National Key Research and Development Program(No.2017YFF0211100).
文摘Si-PIN photodetectors having features such as low cost,small size,low weight,low voltage,and low power consumption are widely used as radiation detectors in electronic personal dosimeters(EPDs).The technical parameters of EPDs based on the Si-PIN photodetectors include photon energy response(PER),angular response,inherent error,and dose rate linearity.Among them,PER is a key parameter for evaluation of EPD measurement accuracy.At present,owing to the limitations of volume,power consumption,and EPD cost,the PER is usually corrected by a combination of single-channel counting techniques and filtering material methods.However,the above-mentioned methods have problems such as poor PER and low measurement accuracy.To solve such problems,in this study,a 1024-channel spectrometry system using a Si-PIN photodetector was developed and fullspectrum measurement in the reference radiation fields was conducted for radiation protection.The measurement results using the few-channel spectroscopy dose method showed that the PER could be controlled within±14%and±2%under the conditions of two and three energy intervals,respectively,with different channel numbers.The PER measured at 0°angle of radiation incidence meets the-29%to+67%requirements of IEC 61526:2010.Meanwhile,the channel number and counts-to-dose conversion factors formed in the experiment can be integrated into an EPD.
基金supported by the National Key Scientific Instruments to Develop Dedicated(Nos.2013YQ090811 and 2016YFF0103800)
文摘Since the room-temperature detector CdZnTe(CZT) has advantages in terms of detection efficiency,energy resolution, and size, it has been extensively used to detect X-rays and gamma-rays. So far, nuclear radiation detectors such as cerium chloride doped with lanthanum bromide(LaBr_3(Ce)), thallium doped with cesium iodide(sI(Tl)), thallium doped with sodium iodide(NaI(Tl)),and high-purity germanium(HPGe) primarily use the spectroscopy-dose rate function(G(E)) to achieve the accurate measurement of air kerma rate(K_a) and ambient dose equivalent rate(H*(10)). However, the spectroscopy-dose rate function has been rarely measured for a CZT detector. In this study, we performed spectrum measurement using a hemispherical CZT detector in a radiation protection standards laboratory. The spectroscopy-dose rate function G(E) of the CZT detector was calculated using the least-squares method combined with the standard dose rate at the measurement position. The results showed that the hemispherical CZT detector could complete the measurement of air kerma rate(K_a) and ambient dose equivalent rate(H*(10)) by using the G(E) function at energies between 48 keV and 1.25 MeV, and the relative intrinsic errors were, respectively, controlled within ± 2. 3 and ± 2. 1%.
基金Supported by State Environment Protection Bureau and Chinese Nuclear Industry Corporation (Project No.90201001)
文摘During 1991-1993, the radioactivity levels of the bone-coal mines were investigated in Hubei, Hunan, Ji-angxi, Zhejiang and Anhui Provinces, respectively, where the reserve of bone-coal is about 90% of our country’s total reserve. The annual additional collective dose equivalent within 80km evaluated region of bone-coal power stations in Nijiangkou and Anren is 1.7 and 1.9 man·mSv, respectively, and that of Zhuantanyan bone-coal shaft is 1.4 man·mSv. The collective dose equivalent caused by bone-coal cinder brick produced for 25 years in the five prov-inces is 1.6×105 man Sv.
基金supported by Guangzhou Science and Technology Planning Project(2023A04J0131)Special fund for scientific innovation strategyconstruction of high level Academy of Agriculture Science(R2020PY-JG009,R2022PY-QY007,202106TD)+2 种基金China Agriculture Research System-CARS-35the Project of Swine Innovation Team in Guangdong Modern Agricultural Research System(2022KJ126)Special Fund for Rural Revitalization Strategy of Guangdong(2023TS-3),China。
文摘Oxidative stress has been associated with a number of physiological problems in swine,including reduced production efficiency.Recently,although there has been increased research into regulatory mechanisms and antioxidant strategies in relation to oxidative stress-induced pig production,it remains so far largely unsuccessful to develop accurate models and nutritional strategies for specific oxidative stress factors.Here,we discuss the dose and dose intensity of the causes of oxidative stress involving physiological,environmental and dietary factors,recent research models and the antioxidant strategies to provide theoretical guidance for future oxidative stress research in swine.
文摘Timer error as well as its convention is very important for dose accuracy during irradiation. This paper determines the timer error of irradiators at Secondary Standard Dosimetry Laboratory (SSDL) in Nigeria. The irradiators are Cs-137 OB6 irradiator and X-ray irradiators at the Protection level SSDL;and Co-60 irradiator at the Therapy Level SSDL. PTW UNIDOS electrometer and LS01 Ionization chamber were used at the Protection Level to obtain doses for both Cs-137 OB6 and X-ray irradiators while an IBA farmer type ionization chamber and an IBA DOSE 1 electrometer were used at the Protection Level SSDL. Single/multiple exposure method and graphical method were used in the determination of the timer error for the three irradiators. The timer error obtained for Cs-137 OB6 irradiator was 0.48 ± 0.01 s, the timer error for the X-ray irradiator was 0.09 ± 0.01 s while the timer error obtained for GammaBeam X200 was 1.21 ± 0.04 s. It was observed that the timer error is not affected by source to detector distance. It was also observed that the timer error of Co-60 Gamma X200 irradiator is increasing with the age of the machine. Source to detector distance and field size do not contribute towards the timer error of the irradiators. The timer error of the Co-60 Gamma X200 irradiator (the only irradiator among the irradiators with a pneumatic system) increases with the age of the irradiator.
基金funded by the National Natural Science Foundation of China (Nos.81771972,52171243,and 52371256)the National Key Research and Development Program of China (No.2017YFC0107405).
文摘X-ray excited photodynamic therapy(X-PDT)is the bravo answer of photodynamic therapy(PDT)for deep-seated tumors,as it employs X-ray as the irradiation source to overcome the limitation of light penetration depth.However,high X-ray irradiation dose caused organ lesions and side effects became the major barrier to X-PDT application.To address this issue,this work employed a classic-al co-precipitation reaction to synthesize NaLuF_(4):15%Tb^(3+)(NLF)with an average particle size of(23.48±0.91)nm,which was then coupled with the photosensitizer merocyanine 540(MC540)to form the X-PDT system NLF-MC540 with high production of singlet oxygen.The system could induce antitumor efficacy to about 24%in relative low dose X-ray irradiation range(0.1-0.3 Gy).In vivo,when NLF-MC540 irradiated by 0.1 Gy X-ray,the tumor inhibition percentage reached 89.5%±5.7%.The therapeutic mechanism of low dose X-PDT was found.A significant increase of neutrophils in serum was found on the third day after X-PDT.By immunohistochemical staining of tumor sections,the Ly6G^(+),CD8^(+),and CD11c^(+)cells infiltrated in the tumor microenvironment were studied.Utilizing the bilat-eral tumor model,the NLF-MC540 with 0.1 Gy X-ray irradiation could inhibit both the primary tumor and the distant tumor growth.De-tected by enzyme linked immunosorbent assay(ELISA),two cytokines IFN-γand TNF-αin serum were upregulated 7 and 6 times than negative control,respectively.Detected by enzyme linked immune spot assay(ELISPOT),the number of immune cells attributable to the IFN-γand TNF-αlevels in the group of low dose X-PDT were 14 and 6 times greater than that in the negative control group,respectively.Thus,it conclude that low dose X-PDT system could successfully upregulate the levels of immune cells,stimulate the secretion of cy-tokines(especially IFN-γand TNF-α),activate antitumor immunity,and finally inhibit colon tumor growth.
基金The Natural Science Foundation of Shandong Province of China under contract Nos ZR2022MA051 and ZR2020MA090the National Natural Science Foundation of China under contract No.U22A2012+2 种基金China Postdoctoral Science Foundation under contract No.2020M670891the SDUST Research Fund under contract No.2019TDJH103the Talent Introduction Plan for Youth Innovation Team in universities of Shandong Province(innovation team of satellite positioning and navigation)。
文摘With the development of ultra-wide coverage technology,multibeam echo-sounder(MBES)system has put forward higher requirements for localization accuracy and computational efficiency of ray tracing method.The classical equivalent sound speed profile(ESSP)method replaces the measured sound velocity profile(SVP)with a simple constant gradient SVP,reducing the computational workload of beam positioning.However,in deep-sea environment,the depth measurement error of this method rapidly increases from the central beam to the edge beam.By analyzing the positioning error of the ESSP method at edge beam,it is discovered that the positioning error increases monotonically with the incident angle,and the relationship between them could be expressed by polynomial function.Therefore,an error correction algorithm based on polynomial fitting is obtained.The simulation experiment conducted on an inclined seafloor shows that the proposed algorithm exhibits comparable efficiency to the original ESSP method,while significantly improving bathymetry accuracy by nearly eight times in the edge beam.
文摘In this editorial I comment on the article,published in the current issue of the World Journal of Clinical Oncology.Primary central nervous system lymphoma(PCNSL)is a disease of elderly and immunocompromised patients.The authors reported clinical results of 19 patients with PCNSL treated with zanubrutinib/high dose methotrexate(HD-MTX)until disease progression.They demonstrated that the combination of zanubrutinib with HD-MTX led to a marked clinical response and tolerability among these patients.They also observed that cerebrospinal fluid liquid biopsy to detect circulating tumor DNA may be a good option for evaluating treatment response and tumor burden in patients with PCNSL.PCNSL is a challenging disease for treatment as these patients present with different neurological states and comorbidities.Treatment has evolved over the years from whole brain radiotherapy to HD-MTX followed by autologous stem cell transplant.Gradually,treatment of patients with PCNSL is going to become individualized.
基金Guangzhou Medical Key Discipline Construction Project(2017-2019):Cancer Therapeutics and Experimental Oncology Project,the Science and Technology Project of Guangzhou,grant number:201804010297。
文摘Objective:The study aimed to explore the characteristic of dose equivalent rates(DERs)of photon and neutron outside the treatment room under high-energy electron mode(dose rate 1000 MU/min)of linac and to evaluate the effectiveness of treatment room protection.Methods:A 451 P pressurized ion chamber and a thermo neutron detector were used to measure the DERs of the photon and neutron at selected points.The effects of field size,applicator size,applicator,anthropomorphic phantom(CDP)and lead block on DER were investigated respectively.Results:The DERs of a photon at the center of shielding door(point A),control console(point B),primary shielding walls(point C,D)and roof of treatment room(point E)increased with increasing electron energy,but decreased with the increasing field size.The DERs of a photons at points A and B are smaller than 2.5μSv/h for all scenarios,while those at point D greater than 2.5μSv/h when irradiated by 18-22 Me V electron.In addition,CDP may change the DERs of a photon at points C and D about 5% to 30%.On the other hand,the DERs of neutron increase with increasing electron energy but decrease with the increase of field size and applicator size,however,the lead block and the applicator itself will change the DERs of leak neutron at point A,but its amplitude is less than 0.5μSv/h.The maximum DER of neutron at point A is 6.18μSv/h irradiated by 22 Me V electron.For other scenarios,they are all in the range of national standards limits.Conclusion:The DERs of a photon and neutron outside the treatment room mainly depend on the energy,field size and irradiation direction of the electron beam.If high-energy 18 Me V and 22 Me V electron beams will be used,the primary shielding walls and shielding doors need reconstructing or increasing thickness.
基金Supported by a grant from thek Project of Beijing Municipal Science&Technology Commission(No.Z181100001718011)
文摘Objective This study aims to investigate the dosimetric differences among four planning methods of physical and biological optimization in hypofractionated radiation therapy for non-small cell lung cancer(NSCLC).Methods Ten NSCLC patients receiving radiation therapy were chosen for this retrospective study.Volumetric modulated arc treatment plans for each patient were remade with dose-volume(DV)functions,biological-physical functions,and biological functions,using the same constraint parameters during optimization.The dosimetric differences between the four types of plans were calculated and analyzed.Results For the target,equivalent uniform dose(EUD)of the EUD and EUD+DV groups was approximately 2.8%–3.6%and 3.2%–3.7%higher than those of the DV and DV+EUD groups,respectively.The average tumor control probability(TCP)of the EUD and EUD+DV groups was also significantly higher than those of the other two groups(P<0.05).The difference in heterogeneity index(HI)among the four groups was also statistically significant(P<0.05),while the difference of conformity index(CI)was not significant(P>0.05).For the organs at risk,the differences of EUD,V5,V10,V20,V30 of normal lung tissues were not statistically significant(P>0.05);however,the mean lung dose of the EUD and EUD+DV groups was slightly lower than those of the other two groups.Conclusion The biological optimization method has obvious advantages of improving EUD and TCP of the target,while decreasing the exposed dose of normal lung.This result is meaningful in choosing plan optimization methods in routine work.
文摘Radioactivity is a natural phenomenon present in the universe. So, because of human life solidarity with a habitat, we are permanently in contact, especially through building materials. The objective of this work is the determination of the used cement radioactivity level in the buildings in Cote d'Ivoire. Thus, samples of grey and white cement currently used on Ivorian territory were taken. In order to determine the radioactivity level of this cement, samples were analyzed by using gamma spectrometry chain which contains a NaI (Tl) scintillation detector designed by the German manufacturer LD-DIDACTIC, coupled to a multichannel analyzer (AMC) using a Cassy Lab software. Thus, the specific activity of the primordial radionuclides 226Ra, 232Th and 40K, was able to be determined. The average values obtained are 29.66 Bq/kg, 34.88 Bq/kg and 178.424 Bq/kg respectively for 226Ra, 232Th and 40K. All average values are below the limit values recommended by UNSCEAR. However, we evaluated the radiological parameters such as the equivalent radium activity and the annual effective dose in order to translate the specific activity in terms of harmfulness. Values obtained for these parameters are below those recommended by ICRP and UNSCEAR. These results show that the risk incurred by the use of these different brands of cement is low.
基金supported by the National Natural Science Foundation of China (Nos.11735003,11975041,and 11961141004)。
文摘In recent years,graphics processing units(GPUs)have been applied to accelerate Monte Carlo(MC)simulations for proton dose calculation in radiotherapy.Nonetheless,current GPU platforms,such as Compute Unified Device Architecture(CUDA)and Open Computing Language(OpenCL),suffer from cross-platform limitation or relatively high programming barrier.However,the Taichi toolkit,which was developed to overcome these difficulties,has been successfully applied to high-performance numerical computations.Based on the class II condensed history simulation scheme with various proton-nucleus interactions,we developed a GPU-accelerated MC engine for proton transport using the Taichi toolkit.Dose distributions in homogeneous and heterogeneous geometries were calculated for 110,160,and 200 MeV protons and were compared with those obtained by full MC simulations using TOPAS.The gamma passing rates were greater than 0.99 and 0.95 with criteria of 2 mm,2%and 1 mm,1%,respectively,in all the benchmark tests.Moreover,the calculation speed was at least 5800 times faster than that of TOPAS,and the number of lines of code was approximately 10 times less than those of CUDA or OpenCL.Our study provides a highly accurate,efficient,and easy-to-use proton dose calculation engine for fast prototyping,beamlet calculation,and education purposes.
文摘The secondary neutron fields at the deep tumor therapy terminal at HIRFL(Heavy Ion Research Facility in Lanzhou) were investigated. The distributions of neutron ambient dose equivalent were measured with a FHT762Wendi-II neutron ambient dose equivalent meter as ^(12)C ions with energies of 165, 207, 270, and 350 Me V/u were bombarded on thick tissue-like targets. The thickness of targets used in the experiments was larger than the range of the carbon ions. The neutron spectra and dose equivalent were simulated by using FLUKA code, and the results agree well with the experimental data. The experiment results showed that the neutron dose produced by fragmentation reactions in tissue can be neglected in carbon-ion therapy, even considering their enhanced biological effectiveness.These results are also valuable for radiation protection, especially in the shielding design of high energy heavy ion medical machines.
基金supported by Natural Science Foundation of Beijing Municipality (Beijing Natural Science Foundation)(No.7191005)。
文摘Compton camera-based prompt gamma(PG) imaging has been proposed for range verification during proton therapy. However, a deviation between the PG and dose distributions, as well as the difference between the reconstructed PG and exact values, limit the effectiveness of the approach in accurate range monitoring during clinical applications. The aim of the study was to realize a PG-based dose reconstruction with a Compton camera, thereby further improving the prediction accuracy of in vivo range verification and providing a novel method for beam monitoring during proton therapy. In this paper, we present an approach based on a subset-driven origin ensemble with resolution recovery and a double evolutionary algorithm to reconstruct the dose depth profile(DDP) from the gamma events obtained by a cadmium-zinc-telluride Compton camera with limited position and energy resolution. Simulations of proton pencil beams with clinical particle rate irradiating phantoms made of different materials and the CT-based thoracic phantom were used to evaluate the feasibility of the proposed method. The results show that for the monoenergetic proton pencil beam irradiating homogeneous-material box phantom,the accuracy of the reconstructed DDP was within 0.3 mm for range prediction and within 5.2% for dose prediction. In particular, for 1.6-Gy irradiation in the therapy simulation of thoracic tumors, the range deviation of the reconstructed spreadout Bragg peak was within 0.8 mm, and the relative dose deviation in the peak area was less than 7% compared to the exact values. The results demonstrate the potential and feasibility of the proposed method in future Compton-based accurate dose reconstruction and range verification during proton therapy.
基金This work was supported in part by the JSPS(Japan Society for the Promotion of Science)KAKENHI(20H04566,22H03998)the National Natural Science Foundation of China(61873348)+1 种基金the Natural Science Foundation of Hubei Province,China(2020CFA031)Wuhan Applied Foundational Frontier Project(2020010601012175).
文摘Active disturbance-rejection methods are effective in estimating and rejecting disturbances in both transient and steady-state responses.This paper presents a deep observation on and a comparison between two of those methods:the generalized extended-state observer(GESO)and the equivalent input disturbance(EID)from assumptions,system configurations,stability conditions,system design,disturbance-rejection performance,and extensibility.A time-domain index is introduced to assess the disturbance-rejection performance.A detailed observation of disturbance-suppression mechanisms reveals the superiority of the EID approach over the GESO method.A comparison between these two methods shows that assumptions on disturbances are more practical and the adjustment of disturbance-rejection performance is easier for the EID approach than for the GESO method.
基金supported by grants from the China Postdoctoral Science Foundation(Grant No.2022M712387)。
文摘Objective:To assess the clinical outcomes and toxicities of once daily(QD)simultaneous dose reduction intensity-modulated radiotherapy(SDR-IMRT-QD;SDR-QD)versus conventional QD IMRT(C-QD)and twice daily(BID)IMRT in patients with limited-stage small cell lung cancer(LS-SCLC).Methods:After propensity score matching(PSM),a retrospective analysis involving 300 patients with LS-SCLC treated using SDR-QD,C-QD,or BID was performed from January 1,2014 to December 31,2019.The prescribed irradiation dose in the SDR-QD cohort was 60 Gy/PGTV and 54 Gy/PTV QD.The radiation dose was 60 Gy for both PGTV and PTV QD in the C-QD cohort.The radiation dose was 45 Gy for both PGTV and PTV in the BID cohort.Toxicities,short-term effects,and survival outcomes were recorded.A meta-analysis on the protective effects of pharmaceuticals for cardiac toxicities induced by anti-tumor therapy was performed.Results:The median overall survival time(MST)in the 3 cohorts were 32.7 months(SDR-QD),26.3 months(C-QD),and 33.6 months(BID);the differences between groups were statistically significant.Lower toxicities and doses to organs-at-risk(OARs)occurred in the SDR-QD and BID cohorts.Further,the cardiac dose dosimetric parameter Vheart40 was negatively associated with survival(r=-0.35,P=0.007).A Vheart40 value of 16.5%was recommended as a cut-off point,which yielded 54.7%sensitivity and 85.7%specificity for predicting negative survival outcomes.The meta-analysis indicated that pharmaceuticals significantly reduced the cardiac toxicities induced by chemotherapy,but not radiotherapy.Conclusions:SDR-QD was shown to have similar toxicities and survival compared with BID,but fewer toxicities and better survival than C-QD.In addition,cardiac dose exposure was negatively associated with survival.Thus,16.5%of the cardiac dosimetric parameter Vheart40 is recommended as the cut-off point,and a Vheart40>16.5%predicts poor survival.
文摘Introduction: Measles is a viral disease that is a major public health problem in both developed and developing countries. It is a contagious disease resulting from infection with the measles virus and is still responsible for more than 100,000 deaths per year. Although vaccination is one of the most successful and cost-effective public health interventions to reduce mortality and morbidity, approximately 1.4 million children worldwide die from vaccine-preventable diseases each year. In Zambia, MCV2 was 66% below WHO recommended target of 95%. This study therefore assessed the acceptability of second dose measles vaccination services among caretakers/mothers with children less than two years of age in Livingstone, Zambia. Methods: The study used analytical cross-sectional study design. A logistic regression analysis was performed to identify factors associated with acceptability of the second dose of measles vaccine. A semi structured questionnaire was administered to collect data on socio demographic characteristics and factors related to acceptability of the second dose of measles vaccine. SPSS version 26.0 was used for descriptive and inferential analysis at 5% level of significance. Results: There was no statistically significant difference in acceptability of the second dose of measles vaccine by gender, marital status, type of employment, income level, socio-cultural and traditional beliefs, and education level. However, there was a statistically significant difference in acceptability of the second dose of measles vaccine by knowledge level of second dose of measles vaccine. A Chi square test result indicated that second dose acceptability was higher with less children than that of respondents with many children (χ2(5) = 15.3, p and knowledge levels (χ2(2) = 14.8, p Changes in knowledge level from medium to high reduced the odds of second dose measles vaccine acceptability. Furthermore, this study showed that acceptance of the second measles vaccination increased from mothers/caretakers with low knowledge (3.6%) to medium knowledge (13.3%) and finally high knowledge (83.1%). Conclusion: Tailored messaging to increase knowledge among mothers and caregivers on the importance of the second dose of measles vaccine is critical in improving acceptability. Therefore, the researchers recommend that the health providers should continue to raise awareness associated with the low acceptability of the second dose of measles vaccine and improve on child preventable diseases such as measles.
基金This work was supported by the National Natural Science Foundation of China(General Program)(Nos.12175114,U2167209)the Foundation of Key Laboratory of Metrology and Calibration Technology(No.JLKG2022001C001)+2 种基金the Platform Development foundation of China Institute for Radiation Protection(No.YP21030101)the National Key R&D Program of China(No.2021YFF0603600)the Tsinghua University Initiative Scientific Research Program(No.20211080081).
文摘Monte Carlo simulations are frequently utilized in radiation dose assessments.However,many researchers find the prevailing computing platforms to be intricate.This highlights a pressing need for a specialized framework for phantom dose evalua-tion.To address this gap,we developed a user-friendly radiation dose assessment platform using the Monte Carlo toolkit,Geant4.The Tsinghua University Phantom Dose(THUDosePD)augments the flexibility of Monte Carlo simulations in dosi-metric research.Originating from THUDose,a code with generic,functional,and application layers,THUDosePD focuses predominantly on anatomical phantom dose assessment.Additionally,it enables medical exposure simulation,intricate geometry creation,and supports both three-dimensional radiation dose analysis and phantom format transformations.The system operates on a multi-threaded parallel CPU architecture,with some modules enhanced for GPU parallel computing.Benchmark tests on the ICRP reference male illustrated the capabilities of THUDosePD in phantom dose assessment,covering the effective dose,three-dimensional dose distribution,and three-dimensional organ dose.We also conducted a voxelization conversion on the polygon mesh phantom,demonstrating the method’s efficiency and consistency.Extended applications based on THUDosePD further underline its broad adaptability.This intuitive,three-dimensional platform stands out as a valuable tool for phantom radiation dosimetry research.