Effect of inlet volute wrap angle on the flow field and performance of double inlet gas cyclones 被引量:3
1
作者 Zetao Wang Guogang Sun +2 位作者 Zhengyuan Song Shiwei Yuan Zhen Qian 《Particuology》 SCIE EI CAS CSCD 2023年第6期29-36,共8页
In response to the divergent understanding of double inlet cyclone performance in the literature,the effect of inlet volute wrap angle on the performance and flow field of double inlet cyclone separator was studied by... In response to the divergent understanding of double inlet cyclone performance in the literature,the effect of inlet volute wrap angle on the performance and flow field of double inlet cyclone separator was studied by Computational Fluid Dynamic(CFD)method.The results showed that the inlet volute wrap angle can affect the comparison results of the single and double inlet gas cyclones with the same total inlet cross-sectional area and velocity.0°and 90°volute double inlet improved the efficiency mainly by separating particles below 10μm,while 180°volute double inlet had no separation advantage for any particles,so the symmetrical double inlet does not always improve the efficiency,and the appropriate inlet volute wrap angle should be selected according to the actual situation,otherwise,the expected performance requirements of the symmetrical double inlet cyclone cannot be achieved.Compared with the flow field,it is found that the inlet volute wrap angle changed the tangential velocity of the sym-metrical double inlet cyclone separator,thus changing the performance. 展开更多
关键词 Cyclone separator Inlet volutewrapangle EFFICIENCY Pressure drop double inlet
原文传递
Assessment of Contractility for Fontan Connections
2
作者 Mert Kestelli Sahin Bozok 《World Journal of Cardiovascular Surgery》 2014年第4期47-50,共4页
This study is performed to investigate the effect of Fontan operations on cardiac contractility. Investigation of articles about the contractility in Fontan published in PubMed up to now revealed that the measurement ... This study is performed to investigate the effect of Fontan operations on cardiac contractility. Investigation of articles about the contractility in Fontan published in PubMed up to now revealed that the measurement of contractility values did not include the rudimentary ventricle. Connections between right atrium and right ventricle as well as right atrium and pulmonary artery were studied in the same group as well. In our opinion, for the single ventricular physiology, the RA-RV and RA-PA connected patients’ preload and afterload values cannot be calculated in the same group since volume of rudimentary ventricles must be considered from this point of view as well. 展开更多
关键词 Myocardial Contractility Fontan Procedure Rudimentary Ventricle Tricuspid Atresia double Inlet Ventricle
下载PDF
Investigation on Inlet Recirculation Characteristics of Double Suction Centrifugal Compressor with Unsymmetrical Inlet 被引量:1
3
作者 YANG Ce WANG Yingjun +3 位作者 LAO Dazhong TONG Ding WEI Longyu LIU Yixiong 《Journal of Thermal Science》 SCIE EI CAS CSCD 2016年第4期312-324,共13页
The inlet recirculation characteristics of double suction centrifugal compressor with unsymmetrical inlet structures were studied in numerical method,mainly focused on three issues including the amounts and difference... The inlet recirculation characteristics of double suction centrifugal compressor with unsymmetrical inlet structures were studied in numerical method,mainly focused on three issues including the amounts and differences of the inlet recirculation in different working conditions,the circumferential non-uniform distributions of the inlet recirculation,the recirculation velocity distributions of the upstream slot of the rear impeller.The results show that there are some differences between the recirculation of the front impeller and that of the rear impeller in whole working conditions..In design speed,the recirculation flow rate of the rear impeller is larger than that of the front impeller in the large flow range,but in the small flow range,the recirculation flow rate of the rear impeller is smaller than that of the front impeller.In different working conditions,the recirculation velocity distributions of the front and rear impeller are non-uniform along the circumferential direction and their non-uniform extents are quite different.The circumferential non-uniform extent of the recirculation velocity varies with the working conditions change.The circumferential non-uniform extent of the recirculation velocity of front impeller and its distribution are determined by the static pressure distribution of the front impeller,but that of the rear impeller is decided by the coupling effects of the inlet flow distortion of the rear impeller,the circumferential unsymmetrical distribution of the upstream slot and the asymmetric structure of the volute.In the design flow and small flow conditions,the recirculation velocities at different circumferential positions of the mean line of the upstream slot cross-section of the rear impeller are quite different,and the recirculation velocities distribution forms at both sides of the mean line are different.The recirculation velocity distributions in the cross-section of the upstream slot depend on the static pressure distributions in the intake duct. 展开更多
关键词 asymmetric intake double suction centrifugal compressor inlet recirculation recirculation flow circumferential distribution