Wuhan Tianxingzhou Changjiang (WTC) Bridge and Nanjing Dashengguan Changjiang (NDC) Bridge are two super high-speed railway 3-trusses composite bridges. This is the first time of using three trusses in such large brid...Wuhan Tianxingzhou Changjiang (WTC) Bridge and Nanjing Dashengguan Changjiang (NDC) Bridge are two super high-speed railway 3-trusses composite bridges. This is the first time of using three trusses in such large bridges in the world. These two types of railway floor systems of the two bridges have never been used in China before. The problem how to conform the deformations and stress levels of the railway floor system of WTC Bridge was studied. After finite element analysis and comparison,the plan of arranging one expansion stringer every two panels in railway floor system were proposed and good effect was obtained. Because of the application of three trusses,the allocation of the loads acted on the deck in three trusses is different and varies in different places of NDC Bridge. This problem was studied by model experiment and 3D finite element analysis. The results of 3D FEM analysis coincide with the model test results. The allocation rule of the loads acting on the deck in three trusses was presented. Because of the application of monolithic decks,the stiffness and structural integrity of NDC Bridge are high.展开更多
In order to improve the heat transfer characteristics of the traditional phase change material(PCM) floor, a new double-layer radiant floor system with PCM is proposed, which can store thermal or cold energy in the ...In order to improve the heat transfer characteristics of the traditional phase change material(PCM) floor, a new double-layer radiant floor system with PCM is proposed, which can store thermal or cold energy in the off-peak period and use them in the peak period. An experimental setup was developed to study the heat transfer characteristics of the new system under both cooling and heating modes. The experimental results show that the double-layer radiant floor system with PCM can meet both the cold and thermal requirements of users. Moreover, with the same duration of the thermal energy storage process, the increase of water temperature supplied to the system can improve the heat transfer characteristics of the system but lead to the discomfort of users. On the other hand, if the air temperature at the end of the thermal energy storage process is the same under different conditions, the increase of supplied water temperature will decrease the thermal energy storage time and ensure the comfort of users.展开更多
The eagle strategy algorithm is combined with particle swarm optimization in this paper.The new algorithm,denoted as the ES-PSO,is implemented by interfacing Etabs structural analysis codes.ES-PSO is used to optimize ...The eagle strategy algorithm is combined with particle swarm optimization in this paper.The new algorithm,denoted as the ES-PSO,is implemented by interfacing Etabs structural analysis codes.ES-PSO is used to optimize the RC ribbed floor system,including floor and underground garage roof.By considering the effects of reinforcement,the principle of virtual work is applied to calculate the deflections of components.Construction cost is taken as the objective function and the constraint conditions are required to satisfy.Accordingly,the optimal layout,the optimal sections of the beams and slabs and the corresponding reinforcements are obtained for different column grids.In this investigation,the RC ribbed floor system is optimized according to the Chinese standard,whose column grids are 8.4 m and 8.4 m.The performance of the ES-PSO algorithm is good enough,which can be applied to practical engineering.The paper can also provide a basis for subsequent optimization design of monolithic structures.展开更多
Reinforced concrete(RC)as a material is most commonly used for buildings construction.Several floor systems are available following the structural and architectural requirements.The current research study provides cos...Reinforced concrete(RC)as a material is most commonly used for buildings construction.Several floor systems are available following the structural and architectural requirements.The current research study provides cost and input energy comparisons of RC office buildings of different floor systems.Conventional solid,ribbed,flat plate and flat slab systems are considered in the study.Building models in three-dimensional using extended threedimensional analysis of building systems(ETABS)and in two-dimensional using slab analysis by the finite element(SAFE)are developed for analysis purposes.Analysis and design using both software packages and manual calculations are employed to obtain the optimum sections and reinforcements to fit cities of low seismic intensities for all the considered building systems.Two ground motion records of low peak ground acceleration(PGA)levels are used to excite the models to measure the input energies.Uniformat cost estimating system is adopted to categorize building components according to 12 divisions.Also,Microsoft(MS)Project is utilized to identify the construction cost and duration of each building system.The study shows that floor system significantly causes changes in the input energy to structures.In addition,the slight increase in the PGA increases the amount of input energy particularly flat plate system.Estimated cost of the flat plate system that the flat slab system is of higher value as compared to ribbed and conventional slab systems.The use of drop panels increases this value as well.Moreover,the estimated cost of the ribbed slab system exceeds that of conventional system.展开更多
The presence of horizontal layered rocks in tunnel engineering significantly impacts the stability and strength of the surrounding rock mass,leading to floor heave in the tunnel.This study focused on preparing layered...The presence of horizontal layered rocks in tunnel engineering significantly impacts the stability and strength of the surrounding rock mass,leading to floor heave in the tunnel.This study focused on preparing layered specimens of rock-like material with varying thickness to investigate the failure behaviors of tunnel floors.The results indicate that thin-layered rock mass exhibits weak interlayer bonding,causing rock layers near the surface to buckle and break upwards when subjected to horizontal squeezing.With an increase in the layer thickness,a transition in failure mode occurs from upward buckling to shear failure along the plane,leading to a noticeable reduction in floor heave deformation.The primary cause of significant deformation in floor heave is upward buckling failure.To address this issue,the study proposes the installation of a partition wall in the middle of the floor to mitigate heave deformation of the rock layers.The results demonstrate that the partition wall has a considerable stabilizing effect on the floor,reducing the zone of buckling failure and minimizing floor heave deformation.It is crucial for the partition wall to be sufficiently high to prevent buckling failure and ensure stability.Through simulation calculations on an engineering example,it is confirmed that implementing a partition wall can effectively reduce floor heave and enhance the stability of tunnel floor.展开更多
BACKGROUND Pelvic floor dysfunction(PFD)is related to muscle fiber tearing during childbirth,negatively impacting postpartum quality of life of parturient.Appropriate and effective intervention is necessary to promote...BACKGROUND Pelvic floor dysfunction(PFD)is related to muscle fiber tearing during childbirth,negatively impacting postpartum quality of life of parturient.Appropriate and effective intervention is necessary to promote PFD recovery.AIM To analyze the use of hydrogen peroxide and silver ion disinfection for vaginal electrodes in conjunction with comprehensive rehabilitation therapy for postpartum women with PFD.METHODS A total of 59 women with PFD who were admitted to the hospital from May 2019 to July 2022 were divided into two groups:Control group(n=27)received comprehensive rehabilitation therapy and observation group(n=32)received intervention with pelvic floor biostimulation feedback instrument in addition to comprehensive rehabilitation therapy.The vaginal electrodes were disinfected with hydrogen peroxide and silver ion before treatment.Intervention for both groups was started 6 weeks postpartum,and rehabilitation lasted for 3 months.Pelvic floor muscle voltage,pelvic floor muscle strength,vaginal muscle voltage,vaginal muscle tone,pelvic floor function,quality of life,and incidence of postpartum PFD were compared between the two groups.RESULTS Before comprehensive rehabilitation treatment,basic data and pelvic floor function were not significantly different between the two groups.After treatment,the observation group showed significant improvements in the maximum voltage and average voltage of pelvic floor muscles,contraction time of type I and type II fibers,pelvic floor muscle strength,vaginal muscle tone,vaginal muscle voltage,and quality of life(GQOLI-74 reports),compared with the control group.The observation group had lower scores on the pelvic floor distress inventory(PFDI-20)and a lower incidence of postpartum PFD,indicating the effectiveness of the pelvic floor biostimulation feedback instrument in promoting the recovery of maternal pelvic floor function.CONCLUSION The combination of the pelvic floor biostimulation feedback instrument and comprehensive rehabilitation nursing can improve pelvic floor muscle strength,promote the recovery of vaginal muscle tone,and improve pelvic floor function and quality of life.The use of hydrogen peroxide and silver ion disinfectant demonstrated favorable antibacterial efficacy and is worthy of clinical application.展开更多
BACKGROUND Spastic pelvic floor syndrome(SPFS)is a refractory pelvic floor disease characterized by abnormal(uncoordinated)contractions of the external anal sphincter and puborectalis muscle during defecation,resultin...BACKGROUND Spastic pelvic floor syndrome(SPFS)is a refractory pelvic floor disease characterized by abnormal(uncoordinated)contractions of the external anal sphincter and puborectalis muscle during defecation,resulting in rectal emptation and obstructive constipation.The clinical manifestations of SPFS are mainly characterized by difficult defecation,often accompanied by a sense of anal blockage and drooping.Manual defecation is usually needed during defecation.From physical examination,it is commonly observed that the patient's anal muscle tension is high,and it is difficult or even impossible to enter with his fingers.AIM To investigate the characteristics of anorectal pressure and botulinum toxin A injection combined with biofeedback in treating pelvic floor muscle spasm syndrome.METHODS Retrospective analysis of 50 patients diagnosed with pelvic floor spasm syndrome.All patients underwent pelvic floor surface electromyography assessment,anorectal dynamics examination,botulinum toxin type A injection 100 U intramuscular injection,and two cycles of biofeedback therapy.RESULTS After the botulinum toxin A injection combined with two cycles of biofeedback therapy,the patient's postoperative resting and systolic blood pressure were significantly lower than before surgery(P<0.05).Moreover,the electromyography index of the patients in the resting stage and post-resting stages was significantly lower than before surgery(P<0.05).CONCLUSION Botulinum toxin A injection combined with biofeedback can significantly reduce pelvic floor muscle tension in treating pelvic floor muscle spasm syndrome.Anorectal manometry is an effective method to evaluate the efficacy of treatment objectively.However,randomized controlled trials are needed.展开更多
Recently the manufacture of epoxy coating and flooring materials begun to be under strong pressure to use more environmentally friendly raw materials in its composition.First tendency to reduce of solvents and diluent...Recently the manufacture of epoxy coating and flooring materials begun to be under strong pressure to use more environmentally friendly raw materials in its composition.First tendency to reduce of solvents and diluents contained in the materials appeared at the end of 90´s.This situation was supported by the Council of Europe in 2004 to reduce VOC emissions to zero till 2020.Solvent materials were thus largely replaced by solvent free materials from which the volatile substances are not released into the air.But pressure continued to increase,and over the past decade began to take centre stage water-based epoxy.On the Czech market solvent based material is still occasionally used,but predominant are solvent free materials.There are no commonly used materials containing wastes as fillers in new water-borne and solvent-free epoxy materials.Characteristics identification of the waste material as a potential filler is a set of properties that determine the limits of secondary raw materials or waste as a filler.This paper describes the basic characteristics which must be selected to meet the requirements,to affect negatively the workability,sedimentation,properties and behavior of the final floor system.Some materials must comply with special requirements,such as resistance to chemicals,etc.Next part of paper talks about utilization of polymer floors and their mechanical properties.展开更多
Machining is as old as humanity, and changes in temperature in both the machine’s internal and external environments can be of great concern as they affect the machine’s thermal stability and, thus, the machine’s d...Machining is as old as humanity, and changes in temperature in both the machine’s internal and external environments can be of great concern as they affect the machine’s thermal stability and, thus, the machine’s dimensional accuracy. This paper is a continuation of our earlier work, which aimed to analyze the effect of the internal temperature of a machine tool as the machine is put into operation and vary the external temperature, the machine floor temperature. Some experiments are carried out under controlled conditions to study how machine tool components get heated up and how this heating up affects the machine’s accuracy due to thermally induced deviations. Additionally, another angle is added by varying the machine floor temperature. The parameters mentioned above are explored in line with the overall thermal stability of the machine tool and its dimensional accuracy. A Robodrill CNC machine tool is used. The CNC was first soaked with thermal energy by gradually raising the machine floor temperature to a certain level before putting the machine in operation. The machine was monitored, and analytical methods were deplored to evaluate thermal stability. Secondly, the machine was run idle for some time under raised floor temperature before it was put into operation. Data was also collected and analyzed. It is observed that machine thermal stability can be achieved in several ways depending on how the above parameters are joggled. This paper, in conclusion, reinforces the idea of machine tool warm-up process in conjunction with a carefully analyzed and established machine floor temperature variation for the approximation of the machine tool’s thermally stability to map the long-time behavior of the machine tool.展开更多
The agility and the flexibility of the current shop floor control systems have been limited so far, owing to the lack of structural flexibility and agility in its control software layer. Most of them are based on trad...The agility and the flexibility of the current shop floor control systems have been limited so far, owing to the lack of structural flexibility and agility in its control software layer. Most of them are based on traditional hierarchical architecture and the top down approach and depend structurally on their specific configuration and job scheduling. Not only can they hardly satisfactorily adapt to these increasing changes and disturbances, but also make the redevelopment and maintenance of shop floor control system (SFCS) to need high cost and much time. And SFCS based on the heterarchical architecture don′t provide a predictable and high performance system, especially not in the heterogeneous environments, where the resources are scarce and the current decisions have serious repercussions on the future performances. For this reason, the heterarchical control is hardly applied in industry. Obviously, it is necessary to develop a new structural framework of reconfigurable SFCS to improve their agility, flexibility and maintainability. This paper presents a holonic framework of reconfigurable SFCS based on holonic manufacturing concepts. The framework is composed of resource holons, product holons and other staff holons. The model of each holon and the co operative mechanisms of holons are described. To verify the proposed approach experimentally, a prototype reconfigurable SFCS for a flexible manufacturing shop floor producing discrete parts is implemented.展开更多
To evaluate the thermal performance of a low-temperature electrical radiant floor heating system,an experimental facility equipped with a constant temperature chamber and different specimen floors is designed and buil...To evaluate the thermal performance of a low-temperature electrical radiant floor heating system,an experimental facility equipped with a constant temperature chamber and different specimen floors is designed and built.The heating cable is installed in the floor slab with a unit-rated power of 30 W/m.Twenty-four different schemes are worked out and tested,which include three kinds of composite floor structures and eight kinds of cable distances.The cable distances are 30,40,50,60,80,100,130,150 mm.The main affective factors of the thermal performance and their influencing regularity are discussed.The experimental results show that the system has good stability and reliability,and the ratio of the radiation heat-transfer rate to the gross heat-transfer rate is greater than 50%.When the floor structure and the cable distance are fixed,the gross heat-transfer rate of the upper floor surface has a maximum value at an optimal cable distance.Under the experimental conditions in this paper,the optimal cable distance is 50 mm.展开更多
The fluxes of masses and the nutrients Ca,Mg,K,N,P and S were determined in the litterfall of two adjacent forest ecosystems of Hungarian oak(Quercus frainetto L.)and European beech(Fagus sylvatica L.)in a mountainous...The fluxes of masses and the nutrients Ca,Mg,K,N,P and S were determined in the litterfall of two adjacent forest ecosystems of Hungarian oak(Quercus frainetto L.)and European beech(Fagus sylvatica L.)in a mountainous area of northeastern Greece in 2010–2015.The foliar litterfall for both species reached about 70%of the total litterfall,and was significantly higher from the other two fractions(woody and rest litterfall).The fluxes of masses and nutrients were compared between ecosystems for each fraction separately.Only one significant statistical difference was found,that of K in the woody litterfall.In addition,the stocks of masses and nutrients were calculated in the forest floors and mineral soils of the two ecosystems.Likewise,the stocks of nutrients in the forest floors and mineral soils were compared between ecosystems.In the L horizon of the forest floors,statistical differences,as a result of species effect,were found for the stocks of Ca and N.In the FH horizons,the masses and all the nutrient stocks differed significantly,as the beech plot had much higher quantities of organic matter and nutrients.These higher quantities were probably due to low soil temperatures(microclimate)and high acidity in the beech plot(species effect)that slowed down decomposition.In the mineral soils,the propagation of random error derived from random errors of the individual soil layers was an important factor in the statistical comparisons.Because of the soil acidity in the beech plot,the stocks of exchangeable base cations were significantly higher in the oak plot,whereas the other nutrient stocks did not differ.展开更多
Adopting distributed control architecture is the important developmentdirection for shop floor management and control system, is also the requirement of making it agile,intelligent and concurrent. Some key problems in...Adopting distributed control architecture is the important developmentdirection for shop floor management and control system, is also the requirement of making it agile,intelligent and concurrent. Some key problems in achieving distributed control architecture areresearched. An activity model of shop floor is presented as the requirement definition of theprototype system. The multi-agent based software architecture is constructed. How the core part inshop floor management and control system, production plan and scheduling is achieved. Thecooperation of different agents is illustrated. Finally, the implementation of the prototype systemis narrated.展开更多
AIM:To assess the role of orthoptics in referring patients with orbital floor blowout fracture(OFBF)for conservative or surgical treatment and based on the results,to propose a scoring system for such decision making....AIM:To assess the role of orthoptics in referring patients with orbital floor blowout fracture(OFBF)for conservative or surgical treatment and based on the results,to propose a scoring system for such decision making.METHODS:A retrospective analysis of 69 patients with OFBF was performed(35 treated conservatively,34 surgically).The role of orthoptics in referring to surgery or conservative treatment was retrospectively evaluated,the factors with the highest significance for decision making were identified,and a scoring system proposed using Logistic regression.RESULTS:According to defined criteria,the treatment was unsuccessful in 2(6%)surgically treated and only in one(3%)conservatively treated patient.The proposed scoring system includes the defect size and several values resulting from the orthoptic examination,the elevation of the eyebulb measured on Lancaster screen being the most significant.CONCLUSION:The study demonstrates the benefits of orthoptic examination when making decisions on conservative or surgical treatment and for diagnosing ocular motility disorder(with or without binocular diplopia)in OFBF patients.The proposed scoring system could,following verification in a prospective study,become a valuable adjunctive tool.展开更多
Based on the fact that the house dust usually falls on the ground, the floor level slit exhaust ventilation system including inlet located at the ceiling and outlet of slit exhaust installed at comer between wall and ...Based on the fact that the house dust usually falls on the ground, the floor level slit exhaust ventilation system including inlet located at the ceiling and outlet of slit exhaust installed at comer between wall and floor was considered. Experiments and simulations were performed to investigate the flow and diffusion fields that are affected by this floor level slit exhaust ventilation system. The characteristics of airflow with experiments and computation fluid dynamics (CFD) are generally similar except airflow at the location of impinging flow and the location right below the inlet. Riboflavin particles were used as the house dust. For the spatial distribution of riboflavin particles in the ventilation system before operation, due to the influence of gravity, different sizes of particles show smooth decay curve. After floor level slit exhaust ventilation system is operated, the decay rate of the particles becomes faster than that after the ventilation system is powered on, and the particles with diameter of 0.5-3.0 μm in the experimental data and calculated values show good agreement.展开更多
In order to overcome the weakness of the former production activity control (PAC) architecture, this paper presents an improved PAC architecture. The BIT-PAC architecture has been applied with the use of information...In order to overcome the weakness of the former production activity control (PAC) architecture, this paper presents an improved PAC architecture. The BIT-PAC architecture has been applied with the use of information technology. It facilitates the information flow from Shop Floor to other areas of the organization and makes the organizations more integrated and productive. This architecture also facilitates the expansion of the Shop Floor functions without disturbing the basic infrastructure. Effectiveness of the BIT-PAC architecture was checked by developing and running application software on a network PC which has supported the dynamic flow of information from Sub-Producers and Sub-Movers to other areas of organization.展开更多
Maxillary sinus floor augmentation using lateral window and crestal technique is considered as predictable methods to increase the residual bone height;however,this surgery is commonly complicated by Schneiderian memb...Maxillary sinus floor augmentation using lateral window and crestal technique is considered as predictable methods to increase the residual bone height;however,this surgery is commonly complicated by Schneiderian membrane perforation,which is closely related to anatomical factors.This article aimed to assess anatomical factors on successful augmentation procedures.After review of the current evidence on sinus augmentation techniques,anatomical factors related to the stretching potential of Schneiderian membrane were assessed and a decision tree for the rational choice of surgical approaches was proposed.Schneiderian membrane perforation might occur when local tension exceeds its stretching potential,which is closely related to anatomical variations of the maxillary sinus.Choice of a surgical approach and clinical outcomes are influenced by the stretching potential of Schneiderian membrane.In addition to the residual bone height,clinicians should also consider the stretching potential affected by the membrane health condition,the contours of the maxillary sinus,and the presence of antral septa when evaluating the choice of surgical approaches and clinical outcomes.展开更多
In this paper, on the basis of the analysis of the current situation of the mine floor flood and the consultation system study, the overall design and structure, specially, the mechanism of many kinds of method for ma...In this paper, on the basis of the analysis of the current situation of the mine floor flood and the consultation system study, the overall design and structure, specially, the mechanism of many kinds of method for making a strategic decision and reasoning of the system of prevention and control of mine floor flood are introduced. The applied examples are given at last.展开更多
The L4 roof of Beijing Olympic International Conference Center is a long-span floor with a tuned mass damper system. The locations of dampers in the layout are not optimal theoretically. This paper is about the locati...The L4 roof of Beijing Olympic International Conference Center is a long-span floor with a tuned mass damper system. The locations of dampers in the layout are not optimal theoretically. This paper is about the location optimization of the 74 sets of dampers on the floor. The main content includes the establishment of a 2D dot-matrix model for the structure, the optimal location combination searched by a genetic algorithm, and the optimal results for five working conditions by calculating the total weight.展开更多
The hygienic threshold limit values for ammonia (25 ppm) for animal welfare but also for occupational safety and health is often exceeded in floor housing systems for laying hens with long time storage of manure in ...The hygienic threshold limit values for ammonia (25 ppm) for animal welfare but also for occupational safety and health is often exceeded in floor housing systems for laying hens with long time storage of manure in bins below draining floors. The major reason for high ammonia concentrations is the large amounts of stored and exposed manure. The possibility to reduce ammonia release by reducing the amount of stored manure in bins in floor housing systems for laying hens has therefore been investigated. Investigations were carried out in a climate chamber equipped with a floor housing system with a manure removal system with two parallel motor driven conveyors placed below an elevated draining floor. The conditions when manure is stored in bins below draining floors were simulated by storing manure on the conveyors for several days at constant ventilation rates and temperatures. The investigations clearly showed that storage of manure in the bin caused a rapid increase in ammonia concentrations. After about 7 days storage of manure in the bin the ammonia concentration exceeded the hygienic threshold limit values. It can be concluded that long time storage of manure in storage bins below draining floors should not be recommended. It was possible to maintain the ammonia concentration below the hygienic threshold limit values when manure was removed frequently with conveyors. Floor housing systems for laying hens with elevated draining floors should therefore be equipped with manure removal systems that enable frequent removal of manure in the bins.展开更多
基金Projects(2004G028, 2004G016) supported by the Science and Technology Development Program of Railways Department, China
文摘Wuhan Tianxingzhou Changjiang (WTC) Bridge and Nanjing Dashengguan Changjiang (NDC) Bridge are two super high-speed railway 3-trusses composite bridges. This is the first time of using three trusses in such large bridges in the world. These two types of railway floor systems of the two bridges have never been used in China before. The problem how to conform the deformations and stress levels of the railway floor system of WTC Bridge was studied. After finite element analysis and comparison,the plan of arranging one expansion stringer every two panels in railway floor system were proposed and good effect was obtained. Because of the application of three trusses,the allocation of the loads acted on the deck in three trusses is different and varies in different places of NDC Bridge. This problem was studied by model experiment and 3D finite element analysis. The results of 3D FEM analysis coincide with the model test results. The allocation rule of the loads acting on the deck in three trusses was presented. Because of the application of monolithic decks,the stiffness and structural integrity of NDC Bridge are high.
基金The National Science and Technology Pillar Program during the 12th Five-Year Plan Period(No.2011BAJ03B14)the National Natural Science Foundation of China(No.51376044)
文摘In order to improve the heat transfer characteristics of the traditional phase change material(PCM) floor, a new double-layer radiant floor system with PCM is proposed, which can store thermal or cold energy in the off-peak period and use them in the peak period. An experimental setup was developed to study the heat transfer characteristics of the new system under both cooling and heating modes. The experimental results show that the double-layer radiant floor system with PCM can meet both the cold and thermal requirements of users. Moreover, with the same duration of the thermal energy storage process, the increase of water temperature supplied to the system can improve the heat transfer characteristics of the system but lead to the discomfort of users. On the other hand, if the air temperature at the end of the thermal energy storage process is the same under different conditions, the increase of supplied water temperature will decrease the thermal energy storage time and ensure the comfort of users.
文摘The eagle strategy algorithm is combined with particle swarm optimization in this paper.The new algorithm,denoted as the ES-PSO,is implemented by interfacing Etabs structural analysis codes.ES-PSO is used to optimize the RC ribbed floor system,including floor and underground garage roof.By considering the effects of reinforcement,the principle of virtual work is applied to calculate the deflections of components.Construction cost is taken as the objective function and the constraint conditions are required to satisfy.Accordingly,the optimal layout,the optimal sections of the beams and slabs and the corresponding reinforcements are obtained for different column grids.In this investigation,the RC ribbed floor system is optimized according to the Chinese standard,whose column grids are 8.4 m and 8.4 m.The performance of the ES-PSO algorithm is good enough,which can be applied to practical engineering.The paper can also provide a basis for subsequent optimization design of monolithic structures.
文摘Reinforced concrete(RC)as a material is most commonly used for buildings construction.Several floor systems are available following the structural and architectural requirements.The current research study provides cost and input energy comparisons of RC office buildings of different floor systems.Conventional solid,ribbed,flat plate and flat slab systems are considered in the study.Building models in three-dimensional using extended threedimensional analysis of building systems(ETABS)and in two-dimensional using slab analysis by the finite element(SAFE)are developed for analysis purposes.Analysis and design using both software packages and manual calculations are employed to obtain the optimum sections and reinforcements to fit cities of low seismic intensities for all the considered building systems.Two ground motion records of low peak ground acceleration(PGA)levels are used to excite the models to measure the input energies.Uniformat cost estimating system is adopted to categorize building components according to 12 divisions.Also,Microsoft(MS)Project is utilized to identify the construction cost and duration of each building system.The study shows that floor system significantly causes changes in the input energy to structures.In addition,the slight increase in the PGA increases the amount of input energy particularly flat plate system.Estimated cost of the flat plate system that the flat slab system is of higher value as compared to ribbed and conventional slab systems.The use of drop panels increases this value as well.Moreover,the estimated cost of the ribbed slab system exceeds that of conventional system.
基金supported by the Key Program of National Natural Science Foundation of China(No.U23A202579)the National Natural Science Foundation of China(No.42277187,42007276,41972297)the Natural Science Foundation of Hebei Province(No.D2021202002)。
文摘The presence of horizontal layered rocks in tunnel engineering significantly impacts the stability and strength of the surrounding rock mass,leading to floor heave in the tunnel.This study focused on preparing layered specimens of rock-like material with varying thickness to investigate the failure behaviors of tunnel floors.The results indicate that thin-layered rock mass exhibits weak interlayer bonding,causing rock layers near the surface to buckle and break upwards when subjected to horizontal squeezing.With an increase in the layer thickness,a transition in failure mode occurs from upward buckling to shear failure along the plane,leading to a noticeable reduction in floor heave deformation.The primary cause of significant deformation in floor heave is upward buckling failure.To address this issue,the study proposes the installation of a partition wall in the middle of the floor to mitigate heave deformation of the rock layers.The results demonstrate that the partition wall has a considerable stabilizing effect on the floor,reducing the zone of buckling failure and minimizing floor heave deformation.It is crucial for the partition wall to be sufficiently high to prevent buckling failure and ensure stability.Through simulation calculations on an engineering example,it is confirmed that implementing a partition wall can effectively reduce floor heave and enhance the stability of tunnel floor.
文摘BACKGROUND Pelvic floor dysfunction(PFD)is related to muscle fiber tearing during childbirth,negatively impacting postpartum quality of life of parturient.Appropriate and effective intervention is necessary to promote PFD recovery.AIM To analyze the use of hydrogen peroxide and silver ion disinfection for vaginal electrodes in conjunction with comprehensive rehabilitation therapy for postpartum women with PFD.METHODS A total of 59 women with PFD who were admitted to the hospital from May 2019 to July 2022 were divided into two groups:Control group(n=27)received comprehensive rehabilitation therapy and observation group(n=32)received intervention with pelvic floor biostimulation feedback instrument in addition to comprehensive rehabilitation therapy.The vaginal electrodes were disinfected with hydrogen peroxide and silver ion before treatment.Intervention for both groups was started 6 weeks postpartum,and rehabilitation lasted for 3 months.Pelvic floor muscle voltage,pelvic floor muscle strength,vaginal muscle voltage,vaginal muscle tone,pelvic floor function,quality of life,and incidence of postpartum PFD were compared between the two groups.RESULTS Before comprehensive rehabilitation treatment,basic data and pelvic floor function were not significantly different between the two groups.After treatment,the observation group showed significant improvements in the maximum voltage and average voltage of pelvic floor muscles,contraction time of type I and type II fibers,pelvic floor muscle strength,vaginal muscle tone,vaginal muscle voltage,and quality of life(GQOLI-74 reports),compared with the control group.The observation group had lower scores on the pelvic floor distress inventory(PFDI-20)and a lower incidence of postpartum PFD,indicating the effectiveness of the pelvic floor biostimulation feedback instrument in promoting the recovery of maternal pelvic floor function.CONCLUSION The combination of the pelvic floor biostimulation feedback instrument and comprehensive rehabilitation nursing can improve pelvic floor muscle strength,promote the recovery of vaginal muscle tone,and improve pelvic floor function and quality of life.The use of hydrogen peroxide and silver ion disinfectant demonstrated favorable antibacterial efficacy and is worthy of clinical application.
文摘BACKGROUND Spastic pelvic floor syndrome(SPFS)is a refractory pelvic floor disease characterized by abnormal(uncoordinated)contractions of the external anal sphincter and puborectalis muscle during defecation,resulting in rectal emptation and obstructive constipation.The clinical manifestations of SPFS are mainly characterized by difficult defecation,often accompanied by a sense of anal blockage and drooping.Manual defecation is usually needed during defecation.From physical examination,it is commonly observed that the patient's anal muscle tension is high,and it is difficult or even impossible to enter with his fingers.AIM To investigate the characteristics of anorectal pressure and botulinum toxin A injection combined with biofeedback in treating pelvic floor muscle spasm syndrome.METHODS Retrospective analysis of 50 patients diagnosed with pelvic floor spasm syndrome.All patients underwent pelvic floor surface electromyography assessment,anorectal dynamics examination,botulinum toxin type A injection 100 U intramuscular injection,and two cycles of biofeedback therapy.RESULTS After the botulinum toxin A injection combined with two cycles of biofeedback therapy,the patient's postoperative resting and systolic blood pressure were significantly lower than before surgery(P<0.05).Moreover,the electromyography index of the patients in the resting stage and post-resting stages was significantly lower than before surgery(P<0.05).CONCLUSION Botulinum toxin A injection combined with biofeedback can significantly reduce pelvic floor muscle tension in treating pelvic floor muscle spasm syndrome.Anorectal manometry is an effective method to evaluate the efficacy of treatment objectively.However,randomized controlled trials are needed.
基金supported by the project"OKTAEDR-partnership and building network."Project registration number is cz.1.07./2.4.00/31.0012.
文摘Recently the manufacture of epoxy coating and flooring materials begun to be under strong pressure to use more environmentally friendly raw materials in its composition.First tendency to reduce of solvents and diluents contained in the materials appeared at the end of 90´s.This situation was supported by the Council of Europe in 2004 to reduce VOC emissions to zero till 2020.Solvent materials were thus largely replaced by solvent free materials from which the volatile substances are not released into the air.But pressure continued to increase,and over the past decade began to take centre stage water-based epoxy.On the Czech market solvent based material is still occasionally used,but predominant are solvent free materials.There are no commonly used materials containing wastes as fillers in new water-borne and solvent-free epoxy materials.Characteristics identification of the waste material as a potential filler is a set of properties that determine the limits of secondary raw materials or waste as a filler.This paper describes the basic characteristics which must be selected to meet the requirements,to affect negatively the workability,sedimentation,properties and behavior of the final floor system.Some materials must comply with special requirements,such as resistance to chemicals,etc.Next part of paper talks about utilization of polymer floors and their mechanical properties.
文摘Machining is as old as humanity, and changes in temperature in both the machine’s internal and external environments can be of great concern as they affect the machine’s thermal stability and, thus, the machine’s dimensional accuracy. This paper is a continuation of our earlier work, which aimed to analyze the effect of the internal temperature of a machine tool as the machine is put into operation and vary the external temperature, the machine floor temperature. Some experiments are carried out under controlled conditions to study how machine tool components get heated up and how this heating up affects the machine’s accuracy due to thermally induced deviations. Additionally, another angle is added by varying the machine floor temperature. The parameters mentioned above are explored in line with the overall thermal stability of the machine tool and its dimensional accuracy. A Robodrill CNC machine tool is used. The CNC was first soaked with thermal energy by gradually raising the machine floor temperature to a certain level before putting the machine in operation. The machine was monitored, and analytical methods were deplored to evaluate thermal stability. Secondly, the machine was run idle for some time under raised floor temperature before it was put into operation. Data was also collected and analyzed. It is observed that machine thermal stability can be achieved in several ways depending on how the above parameters are joggled. This paper, in conclusion, reinforces the idea of machine tool warm-up process in conjunction with a carefully analyzed and established machine floor temperature variation for the approximation of the machine tool’s thermally stability to map the long-time behavior of the machine tool.
文摘The agility and the flexibility of the current shop floor control systems have been limited so far, owing to the lack of structural flexibility and agility in its control software layer. Most of them are based on traditional hierarchical architecture and the top down approach and depend structurally on their specific configuration and job scheduling. Not only can they hardly satisfactorily adapt to these increasing changes and disturbances, but also make the redevelopment and maintenance of shop floor control system (SFCS) to need high cost and much time. And SFCS based on the heterarchical architecture don′t provide a predictable and high performance system, especially not in the heterogeneous environments, where the resources are scarce and the current decisions have serious repercussions on the future performances. For this reason, the heterarchical control is hardly applied in industry. Obviously, it is necessary to develop a new structural framework of reconfigurable SFCS to improve their agility, flexibility and maintainability. This paper presents a holonic framework of reconfigurable SFCS based on holonic manufacturing concepts. The framework is composed of resource holons, product holons and other staff holons. The model of each holon and the co operative mechanisms of holons are described. To verify the proposed approach experimentally, a prototype reconfigurable SFCS for a flexible manufacturing shop floor producing discrete parts is implemented.
文摘To evaluate the thermal performance of a low-temperature electrical radiant floor heating system,an experimental facility equipped with a constant temperature chamber and different specimen floors is designed and built.The heating cable is installed in the floor slab with a unit-rated power of 30 W/m.Twenty-four different schemes are worked out and tested,which include three kinds of composite floor structures and eight kinds of cable distances.The cable distances are 30,40,50,60,80,100,130,150 mm.The main affective factors of the thermal performance and their influencing regularity are discussed.The experimental results show that the system has good stability and reliability,and the ratio of the radiation heat-transfer rate to the gross heat-transfer rate is greater than 50%.When the floor structure and the cable distance are fixed,the gross heat-transfer rate of the upper floor surface has a maximum value at an optimal cable distance.Under the experimental conditions in this paper,the optimal cable distance is 50 mm.
基金financially supported by the Programme of "Effects of Atmospheric Pollutants on Forest Ecosystems" from the Ministry of Agriculture and Foodthe Greek Ministry of Environmentthe European Commission
文摘The fluxes of masses and the nutrients Ca,Mg,K,N,P and S were determined in the litterfall of two adjacent forest ecosystems of Hungarian oak(Quercus frainetto L.)and European beech(Fagus sylvatica L.)in a mountainous area of northeastern Greece in 2010–2015.The foliar litterfall for both species reached about 70%of the total litterfall,and was significantly higher from the other two fractions(woody and rest litterfall).The fluxes of masses and nutrients were compared between ecosystems for each fraction separately.Only one significant statistical difference was found,that of K in the woody litterfall.In addition,the stocks of masses and nutrients were calculated in the forest floors and mineral soils of the two ecosystems.Likewise,the stocks of nutrients in the forest floors and mineral soils were compared between ecosystems.In the L horizon of the forest floors,statistical differences,as a result of species effect,were found for the stocks of Ca and N.In the FH horizons,the masses and all the nutrient stocks differed significantly,as the beech plot had much higher quantities of organic matter and nutrients.These higher quantities were probably due to low soil temperatures(microclimate)and high acidity in the beech plot(species effect)that slowed down decomposition.In the mineral soils,the propagation of random error derived from random errors of the individual soil layers was an important factor in the statistical comparisons.Because of the soil acidity in the beech plot,the stocks of exchangeable base cations were significantly higher in the oak plot,whereas the other nutrient stocks did not differ.
基金This project is supported by National Natural Science Foundation of China(No.50105006,No.59990470)(No.2001AA412140).
文摘Adopting distributed control architecture is the important developmentdirection for shop floor management and control system, is also the requirement of making it agile,intelligent and concurrent. Some key problems in achieving distributed control architecture areresearched. An activity model of shop floor is presented as the requirement definition of theprototype system. The multi-agent based software architecture is constructed. How the core part inshop floor management and control system, production plan and scheduling is achieved. Thecooperation of different agents is illustrated. Finally, the implementation of the prototype systemis narrated.
基金the Ministry of Health,Czech Republic Conceptual Development of Research Organization(FNOs/2017).
文摘AIM:To assess the role of orthoptics in referring patients with orbital floor blowout fracture(OFBF)for conservative or surgical treatment and based on the results,to propose a scoring system for such decision making.METHODS:A retrospective analysis of 69 patients with OFBF was performed(35 treated conservatively,34 surgically).The role of orthoptics in referring to surgery or conservative treatment was retrospectively evaluated,the factors with the highest significance for decision making were identified,and a scoring system proposed using Logistic regression.RESULTS:According to defined criteria,the treatment was unsuccessful in 2(6%)surgically treated and only in one(3%)conservatively treated patient.The proposed scoring system includes the defect size and several values resulting from the orthoptic examination,the elevation of the eyebulb measured on Lancaster screen being the most significant.CONCLUSION:The study demonstrates the benefits of orthoptic examination when making decisions on conservative or surgical treatment and for diagnosing ocular motility disorder(with or without binocular diplopia)in OFBF patients.The proposed scoring system could,following verification in a prospective study,become a valuable adjunctive tool.
基金Project supported by Ministry of Land, Infrastructure, Transport and Tourism of Japan Project(DUT10RC(3)103) supported by the Fundamental Research Funds for the Central Universities in China+2 种基金 Project(20111027) supported by the Liaoning Provincial Scientific Research Foundation, China Key Project (2012BAJ02B05) supported by the Twelfth Five-Year National Technology Program of China Project supported by Dalian Municipal Construction Technology Program, China
文摘Based on the fact that the house dust usually falls on the ground, the floor level slit exhaust ventilation system including inlet located at the ceiling and outlet of slit exhaust installed at comer between wall and floor was considered. Experiments and simulations were performed to investigate the flow and diffusion fields that are affected by this floor level slit exhaust ventilation system. The characteristics of airflow with experiments and computation fluid dynamics (CFD) are generally similar except airflow at the location of impinging flow and the location right below the inlet. Riboflavin particles were used as the house dust. For the spatial distribution of riboflavin particles in the ventilation system before operation, due to the influence of gravity, different sizes of particles show smooth decay curve. After floor level slit exhaust ventilation system is operated, the decay rate of the particles becomes faster than that after the ventilation system is powered on, and the particles with diameter of 0.5-3.0 μm in the experimental data and calculated values show good agreement.
文摘In order to overcome the weakness of the former production activity control (PAC) architecture, this paper presents an improved PAC architecture. The BIT-PAC architecture has been applied with the use of information technology. It facilitates the information flow from Shop Floor to other areas of the organization and makes the organizations more integrated and productive. This architecture also facilitates the expansion of the Shop Floor functions without disturbing the basic infrastructure. Effectiveness of the BIT-PAC architecture was checked by developing and running application software on a network PC which has supported the dynamic flow of information from Sub-Producers and Sub-Movers to other areas of organization.
基金supported by grants from:1.Young Clinical Research Fund of the Chinese Stomatological Association[grant number CSA-SIS2022-19]Sichuan Science and Technology Program:[grant number 2023NSFSC0567].
文摘Maxillary sinus floor augmentation using lateral window and crestal technique is considered as predictable methods to increase the residual bone height;however,this surgery is commonly complicated by Schneiderian membrane perforation,which is closely related to anatomical factors.This article aimed to assess anatomical factors on successful augmentation procedures.After review of the current evidence on sinus augmentation techniques,anatomical factors related to the stretching potential of Schneiderian membrane were assessed and a decision tree for the rational choice of surgical approaches was proposed.Schneiderian membrane perforation might occur when local tension exceeds its stretching potential,which is closely related to anatomical variations of the maxillary sinus.Choice of a surgical approach and clinical outcomes are influenced by the stretching potential of Schneiderian membrane.In addition to the residual bone height,clinicians should also consider the stretching potential affected by the membrane health condition,the contours of the maxillary sinus,and the presence of antral septa when evaluating the choice of surgical approaches and clinical outcomes.
文摘In this paper, on the basis of the analysis of the current situation of the mine floor flood and the consultation system study, the overall design and structure, specially, the mechanism of many kinds of method for making a strategic decision and reasoning of the system of prevention and control of mine floor flood are introduced. The applied examples are given at last.
基金Funded by the National Natural Science Foundation of China(No.51278106)the Scientific Program of the Bureau of Education,Fujian Province(No.JA15629)
文摘The L4 roof of Beijing Olympic International Conference Center is a long-span floor with a tuned mass damper system. The locations of dampers in the layout are not optimal theoretically. This paper is about the location optimization of the 74 sets of dampers on the floor. The main content includes the establishment of a 2D dot-matrix model for the structure, the optimal location combination searched by a genetic algorithm, and the optimal results for five working conditions by calculating the total weight.
文摘The hygienic threshold limit values for ammonia (25 ppm) for animal welfare but also for occupational safety and health is often exceeded in floor housing systems for laying hens with long time storage of manure in bins below draining floors. The major reason for high ammonia concentrations is the large amounts of stored and exposed manure. The possibility to reduce ammonia release by reducing the amount of stored manure in bins in floor housing systems for laying hens has therefore been investigated. Investigations were carried out in a climate chamber equipped with a floor housing system with a manure removal system with two parallel motor driven conveyors placed below an elevated draining floor. The conditions when manure is stored in bins below draining floors were simulated by storing manure on the conveyors for several days at constant ventilation rates and temperatures. The investigations clearly showed that storage of manure in the bin caused a rapid increase in ammonia concentrations. After about 7 days storage of manure in the bin the ammonia concentration exceeded the hygienic threshold limit values. It can be concluded that long time storage of manure in storage bins below draining floors should not be recommended. It was possible to maintain the ammonia concentration below the hygienic threshold limit values when manure was removed frequently with conveyors. Floor housing systems for laying hens with elevated draining floors should therefore be equipped with manure removal systems that enable frequent removal of manure in the bins.