Dual-negative-objective Coordinated Control of Brushless Doubly Fed Induction Generator under Unbalanced Grid Voltage
1
作者 Ming Cheng Zheng Cao Xiaoming Yan 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第3期347-355,共9页
This article proposes a dual-negative-objective coordinated control strategy for brushless doubly fed induction generator(BDFIG)based wind power generation system under unbalanced grid voltage.To alleviate the mechani... This article proposes a dual-negative-objective coordinated control strategy for brushless doubly fed induction generator(BDFIG)based wind power generation system under unbalanced grid voltage.To alleviate the mechanical stress and impaction on rotating shaft,the negative control objective(NCO)of machine side converter(MSC)is set to suppress the ripple of electromagnetic torque.While the NCO of grid side converter(GSC)is selected to suppress the oscillation of total output active power or the unbalanced degree of total output current for BDFIG generation system.In comparison with traditional single converter control scheme of the MSC or GSC,dual NCOs can be satisfied at the same time due to the enlarged freedom degree in the proposed improved coordinated control system for back-toback converters.The effectiveness of proposed control strategy is validated by simulation and experimental results on a dual-cagerotor BDFIG(DCR-BDFIG)prototype. 展开更多
关键词 Brushless doubly fed induction generator Dual-negative-objective Freedom degree Unbalanced grid voltage
下载PDF
Enhanced control of DFIG-used back-to-back PWM VSC under unbalanced grid voltage conditions 被引量:20
2
作者 HU Jia-bing HE Yi-kang NIAN Heng 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2007年第8期1330-1339,共10页
This paper presents a unified positive-and negative-sequence dual-dq dynamic model of wind-turbine driven doubly-fed induction generator(DFIG) under unbalanced grid voltage conditions. Strategies for enhanced control ... This paper presents a unified positive-and negative-sequence dual-dq dynamic model of wind-turbine driven doubly-fed induction generator(DFIG) under unbalanced grid voltage conditions. Strategies for enhanced control and operation of a DFIG-used back-to-back(BTB) PWM voltage source converter(VSC) are proposed. The modified control design for the grid-side converter in the stationary αβ frames diminishes the amplitude of DC-link voltage ripples of twice the grid frequency,and the two proposed control targets for the rotor-side converter are alternatively achieved,which,as a result,improve the fault-ride through(FRT) capability of the DFIG based wind power generation systems during unbalanced network supply. A complete unbalanced control scheme with both grid-and rotor-side converters included is designed. Finally,simulation was carried out on a 1.5 MW wind-turbine driven DFIG system and the validity of the developed unified model and the feasibility of the proposed control strategies are all confirmed by the simulated results. 展开更多
关键词 Unbalanced grid voltage Doubly-fed induction generator (DFIG) Back-to-back (BTB) Fault-ride through (FRT) voltage source converter (VSC)
下载PDF
Predictive direct power control of three-phase PWM rectifier based on TOGI grid voltage sensor free algorithm
3
作者 ZHAO Feng LI Shute +4 位作者 CHEN Xiaoqiang WANG Ying GAN Yanqi NIU Xinqiang ZHANG Fan 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2022年第4期451-459,共9页
In predictive direct power control(PDPC)system of three-phase pulse width modulation(PWM)rectifier,grid voltage sensor makes the whole system more complex and costly.Therefore,third-order generalized integrator(TOGI)i... In predictive direct power control(PDPC)system of three-phase pulse width modulation(PWM)rectifier,grid voltage sensor makes the whole system more complex and costly.Therefore,third-order generalized integrator(TOGI)is used to generate orthogonal signals with the same frequency to estimate the grid voltage.In addition,in view of the deviation between actual and reference power in the three-phase PWM rectifier traditional PDPC strategy,a power correction link is designed to correct the power reference value.The grid voltage sensor free algorithm based on TOGI and the corrected PDPC strategy are applied to three-phase PWM rectifier and simulated on the simulation platform.Simulation results show that the proposed method can effectively eliminate the power tracking deviation and the grid voltage.The effectiveness of the proposed method is verified by comparing the simulation results. 展开更多
关键词 three-phase PWM rectifier predictive direct power control grid voltage sensor free algorithm third-order generalized integrator power correction
下载PDF
Design-oriented Transient Stability Assessment for Droop-controlled Converter Considering Grid Voltage Phase-angle Jump
4
作者 Pingjuan Ge Hailiang Xu +3 位作者 Ruitong Mao Chunming Tu Fan Xiao Qi Guo 《Chinese Journal of Electrical Engineering》 EI CSCD 2024年第3期63-76,共14页
Droop-controlled voltage-source converters(VSCs)can provide frequency and voltage support to power grids.However,during a grid fault,VsCs may experience transient instability,which can be significantly affected by bot... Droop-controlled voltage-source converters(VSCs)can provide frequency and voltage support to power grids.However,during a grid fault,VsCs may experience transient instability,which can be significantly affected by both the control parameters and fault conditions.This mechanism has not been fully elucidated in previous studies.In particular,grid-voltage faults are commonly accompanied by a grid voltage phase-angle jump(VPAJ),which is typically ignored in the evaluation of the transient stability of VSCs.To address this issue,this study comprehensively assesses the impact of the VPAJ and key control parameters on the transient characteristics of VSCs.Furthermore,the critical clearing angle and critical clearing time are quantitatively calculated to define the transient stability boundary.In addition,a transient stability-enhancement control method that considers the transient stability constraints is proposed.Finally,simulations and experimental tests are conducted to validate both the theoretical analysis and proposed method. 展开更多
关键词 Droop-controlled VSC grid voltage phase-angle jump(VPAJ) transient stability boundary transient stability assessmentcontrol
原文传递
Multiple target implementation for a doubly fed induction generator based on direct power control under unbalanced and distorted grid voltage 被引量:2
5
作者 Heng NIAN Yi-peng SONG 《Frontiers of Information Technology & Electronic Engineering》 SCIE EI CSCD 2015年第4期321-334,共14页
This paper presents a multiple target implementation technique for a doubly fed induction generator (DFIG) under unbalanced and distorted grid voltage based on direct power control (DPC). Based on the mathematical... This paper presents a multiple target implementation technique for a doubly fed induction generator (DFIG) under unbalanced and distorted grid voltage based on direct power control (DPC). Based on the mathematical model of DFIG under unbalanced and distorted voltage, the proportional and integral (PI) regulator is adopted to regulate the DFIG average active and reactive powers, while the vector P1 (VPI) resonant regulator is used to achieve three alternative control targets: (1) balanced and sinusoidal stator current; (2) smooth instantaneous stator active and reactive powers; (3) smooth electromagnetic torque and instantaneous stator reactive power. The major advantage of the proposed control strategy over the conventional method is that neither negative and harmonic sequence decomposition of grid voltage nor complicated control reference calculation is required. The insensitivity of the proposed control strategy to DFIG parameter deviation is analyzed. Finally, the DFIG experimental system is developed to validate the availability of the proposed DPC strategy under unbalanced and distorted grid voltage, 展开更多
关键词 Direct power control Doubly fed induction generator Unbalanced and distorted grid voltage Vector proportionaland integral resonant regulator Parameter deviation
原文传递
Comparison of resonant current regulators for DFIG during grid voltage distortion 被引量:2
6
作者 Yi-peng SONG Heng NIAN 《Journal of Zhejiang University-Science C(Computers and Electronics)》 SCIE EI 2013年第12期953-965,共13页
We investigate two different kinds of resonant current regulators for a doubly fed induction generator(DFIG) under distorted grid voltage conditions: proportional integral resonant(PIR) regulator with traditional reso... We investigate two different kinds of resonant current regulators for a doubly fed induction generator(DFIG) under distorted grid voltage conditions: proportional integral resonant(PIR) regulator with traditional resonant part and vector proportional integral(VPI) regulator with VPI resonant part. Based on the mathematical model of DFIG under distorted grid voltage, the transfer function and frequency response characteristics of the two current regulators are analyzed and compared. The superiority of the VPI current regulator over the PIR regulator is pointed out, and the influence of discretization methods on the performance of the resonant current regulator is studied. All the results are validated by MATLAB simulation and experiments. 展开更多
关键词 Doubly fed induction generator Harmonically distorted grid voltage Resonant current regulator Vector PI current regulator Diseretization method
原文传递
Control Strategy of MMC Battery Energy Storage System under Asymmetrical Grid Voltage Condition 被引量:1
7
作者 Lei Zhang Feng Gao Nan Li 《Chinese Journal of Electrical Engineering》 2016年第2期76-83,共8页
A battery energy storage system using modular multilevel converter(MMC)as the interfacing converter could have several inherent advantages when compared with battery energy storage systems based on two-level inverter ... A battery energy storage system using modular multilevel converter(MMC)as the interfacing converter could have several inherent advantages when compared with battery energy storage systems based on two-level inverter or cascaded H-bridge converter.It can manage the state-of-charges(SOCs)of all batteries to be equal to avoid the overcharge or over discharge of single battery.The inherent power exchange characteristics using circulating currents could increase the control flexibility and consequently improve the output quality and the internal regulation capability.This paper investigates the operational principle and control strategy of MMC battery energy storage system under unbalanced grid voltage condition,where key issues of system model and corresponding control methods are very different from those under the normal grid voltage condition.The injected de current control,SOC balancing control and circulating current control methods are fully discussed in this paper.Finally,the theoretical findings were verified through Matlab simulation and a scaled down experimental prototype. 展开更多
关键词 Modular multilevel converters(MMC) battery energy storage system circulating current asymmetrical grid voltage
原文传递
Power-line Modem over the Low Voltage Grid Using Direct Sequence Spread Spectrum Techniques
8
作者 A. Mahgoub H. Abdeel-Baky E. El-Badawy 《Journal of Energy and Power Engineering》 2011年第6期562-568,共7页
Power-line networks are designed to deliver electricity. They reach most of the domiciles and other buildings nowadays, so most of the people have access to it. On the other hand the backbone for the communications ne... Power-line networks are designed to deliver electricity. They reach most of the domiciles and other buildings nowadays, so most of the people have access to it. On the other hand the backbone for the communications networks is not available in all countries especially the developing ones. A high cost and changing the design for the networks may be needed to construct this backbone. If data can be transmitted over the power-line networks, a recognized cost and time save can be achieved. In Egypt, the infrastructure is not always available for constructing a communications network backbone due to the already designed buildings before the need for these backbones. In this paper, we overcome this problem by designing a reliable Power-line Modem that operates safely on the low voltage grid. The modem is based on the Direct Sequence Spread Spectrum technique. It uses the mains zero crossing as an efficient way for the synchronization between the transmitter and the receiver. The Modem takes into account the problems of the Power-line including noise, attenuation and impedance dismatching. 展开更多
关键词 Power-line modem DS/SS micro-controller (firmware) low voltage grid.
下载PDF
Next Higher Transmisson Voltage for Northwest Power Grid in China──Progess of And Some Comments on the Research Work
9
作者 Qian Jia-xiang ZhangRu-zhen (Northwest Electric Power Group) 《Electricity》 2000年第2期15-18,共4页
The situation and status of the research work on the next higher transmission voltage for Northwest Power Grid in China are briefly presented in this paper. It has been preliminarily determined that 750 kV will be ado... The situation and status of the research work on the next higher transmission voltage for Northwest Power Grid in China are briefly presented in this paper. It has been preliminarily determined that 750 kV will be adopted as the next higher transmission voltage to the 330 kV being used. In consideration of the temporary slowing down of the growth of electric power industry in Northwest China and the advance of the.research work on nation--wide interconnection, the authors put forward their views on this problem. 展开更多
关键词 Progess of And Some Comments on the Research Work Next Higher Transmisson voltage for Northwest Power grid in China
下载PDF
Control strategy of LCL-type three-phase photovoltaic grid connected inverter 被引量:2
10
作者 WANG Si-hua WANG Jin-qiang 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2019年第3期254-265,共12页
The grid-connected inverter with LCL filter has the ability of easily attenuating high-frequency current harmonics. However, its suppression effect on the background harmonics in grid voltage is limited. A control str... The grid-connected inverter with LCL filter has the ability of easily attenuating high-frequency current harmonics. However, its suppression effect on the background harmonics in grid voltage is limited. A control strategy is presented, which is composed of an inner loop of capacitor current feedforward, an outer loop of grid-current feedforward and feedforward of grid voltage. The limitations and steps of parameters design for LCL filter are analyzed. Meanwhile, the capacitor current loop is employed to damp the resonant peak caused by the LCL filter and enhance the stability. The properties of different controllers are analyzed and compared, thereinto quasi-proportional-rasonant (PR) controller realizes the control with zero steady-state error of AC variables in static coordinates. In order to suppress the current distortion effected by the background harmonics in grid voltage, the feed-forward function is calculated for the grid-connected inverter with an LCL filter. After simplifying the block diagram, a full-feedforward control strategy for grid voltage is proposed. Theoretical analysis and Matlab/Simulink simulation results show that the proposed method has the advantages of high steady accuracy, fast dynamic response and strong robustness. 展开更多
关键词 three-phase grid-connected inverter LCL filter active damping quasi-proportional-resonant (PR) control full-feedforward of grid voltages
下载PDF
Grid-connected inverter for wind power generation system 被引量:1
11
作者 杨勇 阮毅 +2 位作者 沈欢庆 汤燕燕 杨影 《Journal of Shanghai University(English Edition)》 CAS 2009年第1期51-56,共6页
In wind power generation system the grid-connected inverter is an important section for energy conversion and transmission, of which the performance has a direct influence on the entire wind power generation system. T... In wind power generation system the grid-connected inverter is an important section for energy conversion and transmission, of which the performance has a direct influence on the entire wind power generation system. The mathematical model of the grid-connected inverter is deduced firstly. Then, the space vector pulse width modulation (SVPWM) is analyzed. The power factor can be controlled close to unity, leading or lagging, which is realized based on H-type current controller and grid voltage vector-oriented control. The control strategy is verified by the simulation and experimental results with a good sinusoidal current, a small harmonic component and a fast dynamic response. 展开更多
关键词 grid-connected inverter space vector pulse width modulation (SVPWM) grid voltage vector-oriented power factor
下载PDF
EFFECT OF GRID BIAS ON DEPOSITION OF NANOCRYSTALLINE DIAMOND FILMS
12
作者 徐锋 左敦稳 +1 位作者 卢文壮 王珉 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2007年第4期317-322,共6页
A positive grid bias and a negative substrate bias voltages are applied to the self-made hot filament chemical vapor deposited (HFCVD) system. The high quality nanocrystalline diamond (NCD) film is successfully de... A positive grid bias and a negative substrate bias voltages are applied to the self-made hot filament chemical vapor deposited (HFCVD) system. The high quality nanocrystalline diamond (NCD) film is successfully deposited by double bias voltage nucleation and grid bias voltage growth. The Micro-Raman XRD SEM and AFM are used to investigate the diamond grain size, microstructure, surface morphology, and nucleation density. Results show that the obtained NCD has grain size of about 20 nm. The effect of grid bias voltage on the nucleation and the diamond growth is studied. Experimental results and theoretical analysis show that the positive grid bias increases the plasma density near the hot filaments, enhances the diamond nucleation, keeps the nanometer size of the diamond grains, and improves the quality of diamond film. 展开更多
关键词 nanocrystalline diamond film hot filament CVD substrate bias voltage grid bias voltage NUCLEATION
下载PDF
A Novel Control Strategy of PWM Rectifier with LCL Filter Under Unbalanced Grid Condition
13
作者 Ke-Wei Cai Ning-Hui Wang Guo-Feng Li 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2014年第1期92-97,共6页
The paper presents a successful design and good result of grid voltage feed-forward control strategy with no damping regulator of LCL filter applied in Three-phase Pulse Width Modulation( PWM) rectifier under unbalanc... The paper presents a successful design and good result of grid voltage feed-forward control strategy with no damping regulator of LCL filter applied in Three-phase Pulse Width Modulation( PWM) rectifier under unbalance grid condition for renewable energy processing. It is demonstrated that the closed-loop current control is decoupled with the grid voltage feed-forward control,and good waveform of grid current with low order harmonics is obtained under unbalance grid condition. This novel strategy is simple and reliable,applied with PI regulator but no resonant controller in α,β two-phase stationary frame. Moreover,the results of experiment and simulation are also illustrated to validate the novel strategy well applied in the closed-loop current control system under unbalanced grid condition. 展开更多
关键词 LCL filter no damping control grid voltage feed-forward control renewable energy processing
下载PDF
Modeling of Residential Photovoltaic (PV) System Connected to Low Voltage (LV) Network: Application to Public Distribution Network of Burkina Faso
14
作者 Abdoulaye Zongo Daouda Konane Frédéric Ouattara 《Journal of Applied Mathematics and Physics》 2022年第9期2698-2707,共10页
Residential photovoltaic (PV) systems connected to the grid are used for self-consumption. Any surplus production is fed into the grid and contributes to improving the voltage. Several techniques are developed to mode... Residential photovoltaic (PV) systems connected to the grid are used for self-consumption. Any surplus production is fed into the grid and contributes to improving the voltage. Several techniques are developed to model their connection. However, studies on methods of injecting energy production into the Low Voltage (LV) network are nowadays a problem. This paper proposes a mathematical model to determine the current to be injected and calculate each node’s voltage. The current equation is a recurrence relation with an initial condition. This initial condition is for the case of a single PV system connected to the LV grid. The equation can also be written in matrix form. Similarly, the voltage solution is a recurrence relation. It also has an initial condition for the first node. Both mathematical formulae with the proposed initial conditions are consistent and can be used for the determination of the current and voltage of the different nodes in the grid. 展开更多
关键词 Residential PV System Low voltage grid NODE Mathematical Model Electric Current
下载PDF
Adaptive rotor current control for wind-turbine driven DFIG using resonant controllers in a rotor rotating reference frame 被引量:3
15
作者 Jia-bing HU Yi-kang HE Hong-sheng WANG 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2008年第2期149-155,共7页
This paper proposes an adaptive rotor current controller for doubly-fed induction generator (DFIG), which consists of a proportional (P) controller and two harmonic resonant (R) controllers implemented in the rotor ro... This paper proposes an adaptive rotor current controller for doubly-fed induction generator (DFIG), which consists of a proportional (P) controller and two harmonic resonant (R) controllers implemented in the rotor rotating reference frame. The two resonant controllers are tuned at slip frequencies ωslip+ and ωslip-, respectively. As a result, the positive- and negative-sequence components of the rotor current are fully regulated by the PR controller without involving the positive- and negative-sequence decomposition, which in effect improves the fault ride-through (FRT) capability of the DFIG-based wind power generation system during the period of large transient grid voltage unbalance. Correctness of the theoretical analysis and feasibility of the proposed unbalanced control scheme are validated by simulation on a 1.5-MW DFIG wind power generation system. 展开更多
关键词 Unbalanced grid voltage Doubly-fed induction generator (DFIG) Proportional plus Resonant (PR) controller Faultride-through (FRT)
下载PDF
On maximum power point tracking control strategy for variable speed constant frequency wind power generation 被引量:1
16
作者 倪红军 《Journal of Chongqing University》 CAS 2010年第1期21-28,共8页
Based on the characteristic of AC-excited variable speed constant frequency(VSCF)wind power generation,the vector control technique was applied in a doubly fed induction generator(DFIG).Maximum wind energy or maximum ... Based on the characteristic of AC-excited variable speed constant frequency(VSCF)wind power generation,the vector control technique was applied in a doubly fed induction generator(DFIG).Maximum wind energy or maximum output power point can be tracked by decoupling control of active power and reactive power.The research result shows that the net power of generation system delivered to grid in maximum wind energy tracking mode is not the most.We presented a novel maximum power point tracking(MPPT)control strategy by analyzing the DFIG mathematic model and power relations which delivered the maximum power to the grid.The maximum power point could be tracked automatically without measuring wind speed in the control strategy and the control was independent of optimal turbine power curve,which had excellent dynamic and static performances and robustness.Simulation and experimental results testify the accuracy and validity of the control strategy. 展开更多
关键词 variable speed constant frequency grid voltage orientation DECOUPLING maximum power point tracking
下载PDF
Evaluation of 1.2 kV SiC MOSFETs in Multilevel Cascaded H-bridge Three-phase Inverter for Medium-voltage Grid Applications 被引量:6
17
作者 Haider Mhiesan Janviere Umuhoza +2 位作者 Kenneth Mordi Chris Farnell H.Alan Mantooth 《Chinese Journal of Electrical Engineering》 CSCD 2019年第2期1-13,共13页
A study is conducted to evaluate 1.2 kV silicon-carbide(SiC)MOSFETs in a cascaded H-bridge(CHB)three-phase inverter for medium-voltage applications.The main purpose of this topology is to remove the need for a bulky 6... A study is conducted to evaluate 1.2 kV silicon-carbide(SiC)MOSFETs in a cascaded H-bridge(CHB)three-phase inverter for medium-voltage applications.The main purpose of this topology is to remove the need for a bulky 60 Hz transformer normally used to step up the output signal of a voltage source inverter to a medium-voltage level.Using SiC devices(1.2-6.5 kV SiC MOSFETs)which have a high breakdown voltage,enables the system to meet and withstand the medium-voltage stress using only a minimal number of cascaded modules.The SiC-based power electronics when used in the presented topology considerably reduce the complexity usually encountered when Si devices are used to meet the medium-voltage level and power scalability.Simulation and preliminary experimental results on a low-voltage prototype verifies the nine-level CHB topology presented in this study. 展开更多
关键词 SiC switching devices cascaded h-bridge inverter medium voltage AC grid energy storage
原文传递
A Fault Current Limiting Hybrid DC Circuit Breaker 被引量:1
18
作者 Lei Huang Qian Zhang +1 位作者 Wenlei Liu Ruixue Liu 《Energy Engineering》 EI 2022年第2期621-636,共16页
Due to the low impedance characteristic of the high voltage direct current(HVDC)grid,the fault current rises extremely fast after a DC-side fault occurs,and this phenomenon seriously endangers the safety of the HVDC g... Due to the low impedance characteristic of the high voltage direct current(HVDC)grid,the fault current rises extremely fast after a DC-side fault occurs,and this phenomenon seriously endangers the safety of the HVDC grid.In order to suppress the rising speed of the fault current and reduce the current interruption requirements of the main breaker(MB),a fault current limiting hybrid DC circuit breaker(FCL-HCB)has been proposed in this paper,and it has the capability of bidirectional fault current limiting and fault current interruption.After the occurrence of the overcurrent in the HVDC grid,the current limiting circuit(CLC)of FCL-HCB is put into operation immediately,and whether the protected line is cut off or resumed to normal operation is decided according to the fault detection result.Compared with the traditional hybrid DC circuit breaker(HCB),the required number of semiconductor switches and the peak value of fault current after fault occurs are greatly reduced by adopting the proposed device.Extensive simulations also verify the effectiveness of the proposed FCL-HCB. 展开更多
关键词 Fault current limiting hybrid DC circuit breaker(FCL-HCB) high voltage direct current(HVDC)grid fault current limiting fault current interruption DC circuit breaker
下载PDF
Evaluation of High Step-up Power Conversion Systems for Large-capacity Photovoltaic Generation Integrated into Medium Voltage DC Grids
19
作者 Shilei Lu Kai Sun +2 位作者 Haixu Shi Yunwei Li Guoen Cao 《Chinese Journal of Electrical Engineering》 CSCD 2021年第4期3-14,共12页
With the increase of dc based renewable energy generation and dc loads,the medium voltage dc(MVDC)distribution network is becoming a promising option for more efficient system integration.In particular,large-capacity ... With the increase of dc based renewable energy generation and dc loads,the medium voltage dc(MVDC)distribution network is becoming a promising option for more efficient system integration.In particular,large-capacity photovoltaic(PV)-based power generation is growing rapidly,and a corresponding power conversion system is critical to integrate these large PV systems into MVDC power grid.Different from traditional ac grid-connected converters,the converter system for dc grid interfaced PV system requires large-capacity dc conversion over a wide range of ultra-high voltage step-up ratios.This is an important issue,yet received limited research so far.In this paper,a thorough study of dc-dc conversion system for a medium-voltage dc grid-connected PV system is conducted.The required structural features for such a conversion system are first discussed.Based on these features,the conversion system is classified into four categories by series-parallel connection scheme of power modules.Then two existing conversion system configurations as well as a proposed solution are compared in terms of input/output performance,conversion efficiency,modulation method,control complexity,power density,reliability,and hardware cost.In-depth analysis is carried out to select the most suitable conversion systems in various application scenarios. 展开更多
关键词 Photovoltaic generation dc-dc conversion medium voltage dc grid large-capacity ultra-high voltage transfer ratio
原文传递
Fault ride-through of renewable energy conversion systems during voltage recovery 被引量:7
20
作者 Ruiqi LI Hua GENG Geng YANG 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2016年第1期28-39,共12页
Asymmetrical voltage swells during recovery of a short-circuit fault lead to fluctuations in the dc-link voltage of a renewable energy conversion system(RECS),and may induce reversed power flow and even trip the RECS.... Asymmetrical voltage swells during recovery of a short-circuit fault lead to fluctuations in the dc-link voltage of a renewable energy conversion system(RECS),and may induce reversed power flow and even trip the RECS. This paper studies characteristics of both typical causes resulting in the practical asymmetrical voltage swell and the voltage at the point of common coupling(PCC)during the fault recovery. As analyzed, the fault recovery process can be divided into two continuous periods in which different control strategies have to be applied. Also protective measures are necessary in the transient period of the process. Additionally, the asymmetrical high-voltage ride-through capability and the controllability criteria of the RECS are analyzed based on eliminating the fluctuations. Furthermore, an asymmetrical control scheme is proposed to maintain the controllability of the RECS and ride through the entire recovery process. As verified by the simulation, the scheme can promise the RECS to deal with the practical fault recovery period and mitigate the dc-link voltage fluctuations, which improves the reliability of the RECS and the power system. 展开更多
关键词 INVERTER Renewable energy conversion system Asymmetrical grid voltage High-voltage ride-through(HVRT) Limit analysis
原文传递