期刊文献+
共找到6,566篇文章
< 1 2 250 >
每页显示 20 50 100
Ultrabright NIR AIEgen nanoparticles-enhanced lateral flow immunoassay platform for accurate diagnostics of complex samples
1
作者 Jia Shu Yujian Li +13 位作者 Huan Cai Qing Fu Chunyang Li Jianbo Yuan Yan Zhao Changjin Liu Haiping Wu Doudou Ling Zhangluxi Liu Guannan Su Qingfeng Cao Xiaolin Huang Rui Chen Peizeng Yang 《Aggregate》 EI CAS 2024年第4期308-318,共11页
Accurate and sensitive near-infrared(NIR)luminescent lateralflow immunoassay(LFIA)has attracted considerable attention in thefield of point-of-care testing(POCT).However,the detection accuracy and sensitivity are often ... Accurate and sensitive near-infrared(NIR)luminescent lateralflow immunoassay(LFIA)has attracted considerable attention in thefield of point-of-care testing(POCT).However,the detection accuracy and sensitivity are often compromised by the lowfluorescence quantum efficiency of the NIRfluorescent probe.(<10%)Herein,ultrabright NIR AIEgen nanoparticles(PS@AIE830NPs)composed of polystyrene(PS)nanoparticles and NIR aggregation-induced emission luminogen(AIEgen)with the maximum emission at 830 nm(AIE830)is reported,and its poten-tial to promote an accurate and sensitive detection of complex samples by LFIA is described.The relative quantum yield(QY)of the PS@AIE830NPs was 14.76%,which was superior to that of the polymer embedding method and indocyanine green(ICG)-based NIR nanoparticles.The PS@AIE830NPs immunolabeled-LFIA com-bined with laboratory-built NIR-LFIA portable quantitative instruments(detected light range 800 nm)completely eliminated background interference and allowed>highly accurate and sensitive detection without any pre-treatment steps.The limits of detection(LODs)for aflatoxin B1(AFB1)in soy sauce,alpha hemolysin(Hla)of Staphylococcus aureus biomarker in jointfluid,and C-reactive protein(CRP)in human haemolysed samples were 0.01 ng mL-1,0.02µg mL-1,and 0.156 mg L-1,respectively,commensurating with those of the corresponding gold standard assays and covering the detection range of interests.It is anticipated that the ultrabright NIR AIEgen nanoparticles will serve as a universally applicable signal probe for NIR-LFIA diagnostics,promising to expand the range of applications for quantitative detection of complex samples. 展开更多
关键词 aggregation-induced emission complex sample lateralflow immunoassay NEAR-INFRARED rapid diagnostic testing
下载PDF
甲状腺激素受体相互作用物11基因变异所致软骨生成不全IA型家系遗传学分析
2
作者 陈慧芳 张钏 +2 位作者 周秉博 陈雪 惠玲 《生殖医学杂志》 CAS 2024年第4期466-472,共7页
软骨生成不全IA型是一种罕见的致死性疾病,以常染色体隐性方式遗传,该疾病的发生与人14号染色体上甲状腺激素受体相互作用物11(TRIP11)基因变异有关。本研究采集了1例超声检查疑似致命性骨骼发育不良胎儿的流产皮肤组织及其父母的静脉血... 软骨生成不全IA型是一种罕见的致死性疾病,以常染色体隐性方式遗传,该疾病的发生与人14号染色体上甲状腺激素受体相互作用物11(TRIP11)基因变异有关。本研究采集了1例超声检查疑似致命性骨骼发育不良胎儿的流产皮肤组织及其父母的静脉血,通过提取基因组DNA,应用全外显子组测序技术对胎儿组织及其父母进行平行测序,对疑似致病变异用Sanger测序进行验证;并对以往报道基因检测结果进行文献复习,结合文献复习探讨该病的临床特点。结果发现了胎儿TRIP11检测到复合杂合变异c.790C>T(p.R264*)/c.589-2A>G,两位点分别来自父亲和母亲,符合常染色体隐性遗传。本研究报道的TRIP11基因复合杂合变异尚未见报道,拓宽了软骨生成不全1A型的基因变异谱,为该家庭的遗传咨询及产前诊断提供了重要的分子基础。 展开更多
关键词 软骨生成不全ia 牙软骨发育不良 甲状腺激素受体相互作用物11基因 高尔基体微管相关蛋白210
下载PDF
基于IA-VMD的浮环密封声发射信号降噪与特征提取
3
作者 张帅 丁俊华 +1 位作者 丁雪兴 力宁 《振动与冲击》 EI CSCD 北大核心 2024年第4期222-229,共8页
针对航空发动机浮环密封运行时,声发射信号易受外界噪声干扰,且特征信号难以提取的问题,提出一种基于免疫算法(immune algorithm, IA)和变分模态分解(variational mode decomposition, VMD)的声发射信号处理方法。首先应用免疫算法对变... 针对航空发动机浮环密封运行时,声发射信号易受外界噪声干扰,且特征信号难以提取的问题,提出一种基于免疫算法(immune algorithm, IA)和变分模态分解(variational mode decomposition, VMD)的声发射信号处理方法。首先应用免疫算法对变分模态分解中的模态数K和惩罚因子α进行优化,采用样本熵为亲和度函数,得到VMD算法中的最佳参数组合。其次,对原始信号进行分解得到若干模态分量(intrinsic mode function, IMF)并计算出各个分量的相对熵,选取差异小的分量进行重构得到降噪信号。仿真信号分析表明,IA-VMD方法可以获得最佳参数,在抗噪声干扰方面具有明显优势。最后,对浮环密封声发射信号降噪并进行特征提取,结果表明,采用IA-VMD方法能够在降噪的同时最大限度保留有效信息,获得表征浮环密封主密封面碰摩状态的声发射信号,为今后浮环密封故障诊断奠定基础。 展开更多
关键词 浮环密封 免疫算法(ia) 变分模态分解(VMD) 声发射 特征提取
下载PDF
利用MPI实现点云SAC-IA并行配准
4
作者 崔家武 曾波 +2 位作者 李海军 甄兆聪 梁建青 《工程勘察》 2024年第4期61-67,共7页
采样一致性初始配准算法(SAC-IA)是点云的一种粗配准算法。针对大规模点云SAC-IA配准效率低、实时性差等问题,本文提出利用消息传递接口MPI实现点云SAC-IA多进程并行配准,主要包括法向量并行估计、SPFH特征及FPFH特征并行计算和SAC-IA... 采样一致性初始配准算法(SAC-IA)是点云的一种粗配准算法。针对大规模点云SAC-IA配准效率低、实时性差等问题,本文提出利用消息传递接口MPI实现点云SAC-IA多进程并行配准,主要包括法向量并行估计、SPFH特征及FPFH特征并行计算和SAC-IA并行配准。实验结果表明,MPI多进程并行算法可显著提高点云SAC-IA配准速度。 展开更多
关键词 SAC-ia MPI 法向量 SPFH特征 FPFH特征
原文传递
口蹄疫病毒O型全自动磁微粒CLIA抗体定量检测方法的建立
5
作者 包艳芳 蒋韬 +8 位作者 何莉 吕律 李涛善 李昕 孙燕燕 杨光 魏婷 潘晓乐 林密 《中国农业科学》 CAS CSCD 北大核心 2024年第4期810-819,共10页
【背景】口蹄疫(foot and mouth disease,FMD)是由口蹄疫病毒引起的一种急性、热性、烈性传染病,疫苗接种是预防临床口蹄疫的有效措施。免疫抗体水平监测则是评估疫苗免疫效果、制定免疫程序的重要依据,是免疫工作和疫情防控必不可少的... 【背景】口蹄疫(foot and mouth disease,FMD)是由口蹄疫病毒引起的一种急性、热性、烈性传染病,疫苗接种是预防临床口蹄疫的有效措施。免疫抗体水平监测则是评估疫苗免疫效果、制定免疫程序的重要依据,是免疫工作和疫情防控必不可少的关键环节,因此建立高效、快速、全自动的抗体检测方法具有重要意义。【目的】基于磁微粒(micromagnetic particles,MPs)化学发光免疫分析技术(CLIA),建立一种新型、全自动、可定量的口蹄疫病毒O型抗体检测方法,为口蹄疫免疫监测和疫情防控提供技术支撑。【方法】使用纳米材料磁微粒为固相载体和分离载体包被捕获抗体,用碱性磷酸酶(alkaline phosphatase,ALP)标记检测抗体,经过条件优化建立了一种新型磁微粒CLIA检测方法(magnetic particle chemiluminescence immunoassay,MP-CLIA)。本方法首先加入磁微粒-兔抗偶联物(magnetic particle-polyclonal antibodies,MPs-p Abs)、待测样本、口蹄疫病毒O型抗原,37℃孵育;再加入适量酶标抗体(ALP-p Abs),37℃孵育;最后加入化学发光底物AMPPD,检测相对发光强度(relative light unit,RLU)。研究通过检测标准品拟合标准曲线,并应用受试者工作特征曲线(receiver operating characteristic,ROC)确定检测方法的判定标准;利用质控样本进行方法学评价,同时检测田间样本,并和液相阻断ELISA(LPB-ELISA)比对,验证临床检测效果。【结果】优化后最佳反应条件为磁微粒浓度0.25 mg·m L^(-1)、口蹄疫病毒O型抗原1﹕1000稀释、酶标抗体1﹕2000稀释、加样量20μL。整个检测过程均在全自动化学发光免疫分析仪中完成,反应时间20 min,在抗体含量0—1280 U(效价0—1﹕2048)范围内标准曲线R2>0.99,可进行定量检测。该方法敏感性为94.66%;特异性为97.10%,检测口蹄疫A型、Asia I型血清型特异性为97.14%,与塞内卡病毒(SVV)、猪繁殖与呼吸综合征病毒(PRRSV)、牛流行热病毒(BEFV)、猪圆环病毒2型(PCV2)、羊痘病毒(QRFV)、小反刍兽疫病毒(PPRV)抗体阳性血清无交叉反应;重复检测变异系数CV值<10%;田间样本检测结果与LPB-ELISA符合率为94.69%,定量结果相关系数R2为0.8473,P<0.0001,相关性显著。【结论】建立的MP-CLIA方法耗时短、操作简便,配套国产全自动化学发光仪,可进行全自动化检测,是一种新型、高效的口蹄疫病毒O型抗体定量检测方法,本方法对应的试剂盒已经完成中试生产和临床检测试验,在全国不同区域试用效果较好,具有较高的临床应用价值。 展开更多
关键词 磁微粒化学发光免疫分析法 口蹄疫 磁微粒 全自动化
下载PDF
基于IAS信号自适应窄带解调的RV减速器摆线轮故障特征提取
6
作者 张珈源 郭瑜 《振动与冲击》 EI CSCD 北大核心 2024年第9期261-266,共6页
RV(rotary vector)减速器广泛应用于工业机器人,研究其关键零部件的故障检测方法具有重要意义。由于RV减速器结构复杂、摆线轮转速低、故障冲击较弱等问题,造成摆线轮故障特征难以用常规振动分析方法提取。针对上述问题,提出一种基于瞬... RV(rotary vector)减速器广泛应用于工业机器人,研究其关键零部件的故障检测方法具有重要意义。由于RV减速器结构复杂、摆线轮转速低、故障冲击较弱等问题,造成摆线轮故障特征难以用常规振动分析方法提取。针对上述问题,提出一种基于瞬时角速度信号自适应窄带解调的RV减速器摆线轮故障特征提取方法。首先对编码器角度信号进行采集,然后使用向前差分法获得瞬时角速度信号,在此基础上,使用角域同步平均提取摆线轮周期相关同步分量,消除非同步干扰,并通过构建边带信噪比指标选取故障信息丰富的啮合谐波频带进行带通滤波,最后对滤波后的信号进行窄带解调,实现对RV减速器摆线轮的故障特征提取。试验结果表明,该方法可以有效地提取RV减速器摆线轮故障特征,且自适应实现优化带宽选择。 展开更多
关键词 RV减速器 摆线轮 瞬时角速度 边带信噪比指标 窄带解调技术
下载PDF
On-site rapid detection of multiple pesticide residues in tea leaves by lateral flow immunoassay
7
作者 Junxia Gao Tianyi Zhang +7 位作者 Yihua Fang Ying Zhao Mei Yang Li Zhao Ye Li Jun Huang Guonian Zhu Yirong Guo 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2024年第2期276-283,共8页
The application of pesticides (mostly insecticides and fungicides) during the tea-planting process will undoubtedly increase the dietary risk associated with drinking tea. Thus, it is necessary to ascertain whether pe... The application of pesticides (mostly insecticides and fungicides) during the tea-planting process will undoubtedly increase the dietary risk associated with drinking tea. Thus, it is necessary to ascertain whether pesticide residues in tea products exceed the maximum residue limits. However, the complex matrices present in tea samples comprise a major challenge in the analytical detection of pesticide residues. In this study, nine types of lateral flow immunochromatographic strips (LFICSs) were developed to detect the pesticides of interest (fenpropathrin, chlorpyrifos, imidacloprid, thiamethoxam, acetamiprid, carbendazim, chlorothalonil, pyraclostrobin, and iprodione). To reduce the interference of tea substrates on the assay sensitivity, the pretreatment conditions for tea samples, including the extraction solvent, extraction time, and purification agent, were optimized for the simultaneous detection of these pesticides. The entire testing procedure (including pretreatment and detection) could be completed within 30 min. The detected results of authentic tea samples were confirmed by ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS), which suggest that the LFICS coupled with sample rapid pretreatment can be used for on-site rapid screening of the target pesticide in tea products prior to their market release. 展开更多
关键词 Lateral flow immunoassay Rapid detection Pesticide multi-residue Tea matrix Sample rapid pretreatment
下载PDF
纤维蛋白胶在处理破裂腹主动脉瘤腔内隔绝术中Ia型内漏的疗效
8
作者 倪建琦 沈兰 +3 位作者 金琴 王国亮 许浏 沈一峰 《浙江临床医学》 2024年第4期537-538,共2页
目的观察应用纤维蛋白胶填塞技术处理破裂腹主动脉瘤腔内隔绝术中Ia型内漏的疗效,评价其可行性、安全性及有效性。方法2010年10月至2022年1月腹主动脉瘤破裂患者47例,完成腹主动脉瘤腔内隔绝术45例,其中男36例,女9例;年龄28~93岁(70... 目的观察应用纤维蛋白胶填塞技术处理破裂腹主动脉瘤腔内隔绝术中Ia型内漏的疗效,评价其可行性、安全性及有效性。方法2010年10月至2022年1月腹主动脉瘤破裂患者47例,完成腹主动脉瘤腔内隔绝术45例,其中男36例,女9例;年龄28~93岁(70±4)岁,13例术中应用纤维蛋白胶填塞术治疗Ⅰa型内漏。术后3、6、12个月复查患者主动脉CT血管造影(CTA)。结果13例术中使用纤维蛋白胶填塞治疗,术中造影提示内漏均消失,患者病情稳定出院。随访1年,13例患者,3例非主动脉因素死亡,其余10例术后3、6、12个月复查主动脉CTA结果均未发现内漏。结论纤维蛋白胶填塞在治疗破裂腹主动脉瘤腔内隔绝术中的Ⅰa型内漏中是安全有效的。 展开更多
关键词 破裂腹主动脉瘤 纤维蛋白胶 ia型内漏
下载PDF
CLIA、RPR、TPPA检测血清中梅毒螺旋体抗体的价值分析
9
作者 赵颖 马跃 《中国现代药物应用》 2024年第5期72-74,共3页
目的 分析化学发光免疫测定法(CLIA)、快速血清反应素试验(RPR)、梅毒螺旋体明胶颗粒凝集试验(TPPA)检测血清中梅毒螺旋体抗体的结果。方法 100例疑似梅毒患者血清样本为研究对象,均采用CLIA、RPR、TPPA进行检测,并以重组免疫印迹法(RI... 目的 分析化学发光免疫测定法(CLIA)、快速血清反应素试验(RPR)、梅毒螺旋体明胶颗粒凝集试验(TPPA)检测血清中梅毒螺旋体抗体的结果。方法 100例疑似梅毒患者血清样本为研究对象,均采用CLIA、RPR、TPPA进行检测,并以重组免疫印迹法(RIBA)检测结果为金标准,分析三种检测方式的检测结果 ,并比较三种检测方式的诊断效能。结果 CLIA检出阳性59例,阴性41例。RPR检出阳性73例,阴性27例。TPPA检出阳性59例,阴性41例。CLIA诊断准确率为69.00%(69/100),敏感度为68.92%(51/74),特异度为69.23%(18/26);RPR诊断准确率为97.00%(97/100),敏感度为97.30%(72/74),特异度为96.15%(25/26);TPPA诊断准确率为77.00%(77/100),敏感度为74.32%(55/74),特异度为84.62%(22/26)。RPR的诊断准确率、敏感度显著高于CLIA、TPPA(P<0.05);RPR的特异度高于CLIA(P<0.05);CLIA与TPPA的诊断准确率、敏感度、特异度差异较小(P>0.05)。结论 RPR在梅毒螺旋体抗体的临床诊断中具有更佳的诊断准确率,可为梅毒患者的治疗提供可靠的诊疗依据。 展开更多
关键词 化学发光免疫测定法 快速血清反应素试验 梅毒螺旋体明胶颗粒凝集试验 梅毒螺旋体抗体
下载PDF
CLIA法检测性激素六项用于女性生殖内分泌疾病诊断中的临床价值 被引量:1
10
作者 张华 《系统医学》 2024年第1期153-156,共4页
目的研究化学发光免疫测定(Chemiluminescent Immunoassay,CLIA)法检测性激素六项用于女性生殖内分泌疾病诊断中的临床价值。方法选取2021年2月—2023年2月于连云港市赣榆区妇幼保健院就诊的41例女性生殖内分泌疾病患者为观察组,并选取... 目的研究化学发光免疫测定(Chemiluminescent Immunoassay,CLIA)法检测性激素六项用于女性生殖内分泌疾病诊断中的临床价值。方法选取2021年2月—2023年2月于连云港市赣榆区妇幼保健院就诊的41例女性生殖内分泌疾病患者为观察组,并选取同时期41例女性健康体检者为对照组。采用CLIA法检测性激素六项,比较两组的性激素水平,并分析观察组在不同月经周期的性激素水平变化情况。结果观察组的卵泡生成素(Follicle Stimulating Hormone,FSH)、促黄体生成素(Luteinizing Hormone,LH)、泌乳素(Prolactin,PRL)、睾酮(Testosterone,T)水平分别为(22.15±3.21)mIU/mL、(47.32±4.36)mIU/mL、(185.36±3.51)ng/mL、(0.79±0.11)ng/mL,高于对照组的(13.50±2.17)mIU/mL、(6.27±1.54)mIU/mL、(13.22±2.62)ng/mL、(0.24±0.04)ng/mL,雌二醇(Estradiol,E2)、孕酮(Progesterone,P)水平分别为(10.43±2.35)pg/mL、(0.05±0.01)ng/mL,低于对照组的(22.22±4.64)pg/mL、(0.33±0.05)ng/mL,差异有统计学意义(t=14.295、56.845、251.651、30.088、14.515、35.161,P均<0.001)。观察组在不同月经周期,其性激素水平呈周期性变化,FSH、LH在卵泡期较低,前者在排卵期略微提高,但差异无统计学意义(P>0.05),而后者则有明显升高趋势,两者在黄体期则明显下降,差异有统计学意义(P均<0.05);PRL、T、P水平呈上升趋势,差异有统计学意义(P均<0.05);E2水平随着卵泡的发育不断升高,黄体期迅速降低,差异有统计学意义(P均<0.05)。结论CLIA法检测性激素六项用于女性生殖内分泌疾病诊断具有明显作用,可为临床治疗提供一定的指导作用。 展开更多
关键词 化学发光免疫测定法 性激素六项 女性生殖内分泌疾病 诊断
下载PDF
Establishment of Double-antigen Sandwich Time-resolved Fluorescence Immunoassay for Detection of Pest des Petits Ruminants Virus
11
作者 Binglei CAO Zhongyuan GE +3 位作者 Qi YANG Hang SUN Yu SUN Xiaohui SONG 《Agricultural Biotechnology》 2024年第4期21-27,共7页
[Objectives]This study was conducted to explore rapid and large-scale screening and detection of peste des petits ruminants(PPR),so as to provide important technical means for prevention,control and purification of PP... [Objectives]This study was conducted to explore rapid and large-scale screening and detection of peste des petits ruminants(PPR),so as to provide important technical means for prevention,control and purification of PPR.[Methods]Soluble N protein and NH fusion protein were successfully obtained in an Escherichia coli expression system by optimizing E.coli codon and expression conditions.Furthermore,based on purified soluble N protein and NH fusion protein,a double-antigen sandwich time-resolved fluorescence immunoassay method for detection of peste des petits ruminants virus(PPRV)was established.[Results]The method has high sensitivity and specificity and can specifically detect the antibody against PPRV in sheep serum,and it has no cross reaction with other related diseases.The method was used to detect 292 clinical samples,and compared with French IDVET competition ELISA kit.The coincidence rates of positive samples and negative samples from the two kinds of test kits were 92.47%and 97.26%,respectively,and the overall coincidence rate was 94.86%.The intra-group and inter-group coefficients of variation in the repeatability test were less than 10%.[Conclusions]Compared with the traditional ELISA method,the double-antigen sandwich time-resolved fluorescence immunoassay for detection of PPRV has equivalent sensitivity and specificity,and simple and rapid operation,and thus high application and popularization value. 展开更多
关键词 Peste des petits ruminants N active protein NH fusion protein Soluble expression and purification Time-resolved fluorescence immunoassay
下载PDF
甲状腺肿瘤免疫检测中应用CLIA测定法的价值分析
12
作者 邵俊峰 《系统医学》 2024年第16期32-34,38,共4页
目的 探究化学发光免疫分析(chemiluminescence immunoassay,CLIA)测定法在甲状腺肿瘤免疫检测中应用价值。方法 非随机选取2022年1月—2023年12月淄博市博山区计划生育服务中心区妇幼保健院收治的100例疑似甲状腺肿瘤患者为研究对象,... 目的 探究化学发光免疫分析(chemiluminescence immunoassay,CLIA)测定法在甲状腺肿瘤免疫检测中应用价值。方法 非随机选取2022年1月—2023年12月淄博市博山区计划生育服务中心区妇幼保健院收治的100例疑似甲状腺肿瘤患者为研究对象,以病理诊断为金标准,分析CLIA测定法的检验效能。结果 100例疑似甲状腺肿瘤患者中,病理组织学检查发现阳性70例,阴性30例。通过受试者工作特征曲线分析及Kappa一致性检验发现,CLIA测定法检出真阳性63例、假阳性2例、真阴性28例、假阴性7例,Kappa值0.795CLIA测定法的曲线下面积为0.917。结论 CLIA测定法检测效能较高,可作为甲状腺肿瘤免疫检测的方式。 展开更多
关键词 化学发光免疫 甲状腺肿瘤 免疫检测
下载PDF
分层模型与改进IA的含DG配电网故障定位研究
13
作者 欧宇航 陆萍 《自动化仪表》 CAS 2024年第10期60-64,共5页
常规的含分布式发电(DG)装置的配电网故障定位方法忽略了配电网馈线节点数量的影响,导致定位结果精度不高。因此,将分层模型与改进免疫算法(IA)相结合,设计了分层模型与改进IA的含DG配电网故障定位方法。首先,构建三层含DG配电网故障分... 常规的含分布式发电(DG)装置的配电网故障定位方法忽略了配电网馈线节点数量的影响,导致定位结果精度不高。因此,将分层模型与改进免疫算法(IA)相结合,设计了分层模型与改进IA的含DG配电网故障定位方法。首先,构建三层含DG配电网故障分层模型,并分析单节点故障信息。然后,通过改进基础IA的抗体间相似度,优化算法的期望繁殖度。最后,基于改进后的IA优化分层模型的节点搜索路径,建立世界坐标系并融合DG开关状态得到最终的故障定位信息。试验结果表明:应用该方法定位的故障节点距离与真实的故障节点距离最大差值仅为0.013 km。该方法表现出的适应度值曲线与最优适应度值曲线高度接近,定位精度较高,能够满足含DG配电网故障运维工作的现实需求。 展开更多
关键词 分布式发电装置 配电网 故障定位 分层模型 改进免疫算法
下载PDF
Deep learning model based on primary tumor to predict lymph node status in clinical stage IA lung adenocarcinoma:a multicenter study
14
作者 Li Zhang Hailin Li +9 位作者 Shaohong Zhao Xuemin Tao Meng Li Shouxin Yang Lina Zhou Mengwen Liu Xue Zhang Di Dong Jie Tian Ning Wu 《Journal of the National Cancer Center》 2024年第3期233-240,共8页
Objective:To develop a deep learning model to predict lymph node(LN)status in clinical stage IA lung adeno-carcinoma patients.Methods:This diagnostic study included 1,009 patients with pathologically confirmed clinica... Objective:To develop a deep learning model to predict lymph node(LN)status in clinical stage IA lung adeno-carcinoma patients.Methods:This diagnostic study included 1,009 patients with pathologically confirmed clinical stage T1N0M0 lung adenocarcinoma from two independent datasets(699 from Cancer Hospital of Chinese Academy of Medical Sciences and 310 from PLA General Hospital)between January 2005 and December 2019.The Cancer Hospital dataset was randomly split into a training cohort(559 patients)and a validation cohort(140 patients)to train and tune a deep learning model based on a deep residual network(ResNet).The PLA Hospital dataset was used as a testing cohort to evaluate the generalization ability of the model.Thoracic radiologists manually segmented tumors and interpreted high-resolution computed tomography(HRCT)features for the model.The predictive performance was assessed by area under the curves(AUCs),accuracy,precision,recall,and F1 score.Subgroup analysis was performed to evaluate the potential bias of the study population.Results:A total of 1,009 patients were included in this study;409(40.5%)were male and 600(59.5%)were female.The median age was 57.0 years(inter-quartile range,IQR:50.0-64.0).The deep learning model achieved AUCs of 0.906(95%CI:0.873-0.938)and 0.893(95%CI:0.857-0.930)for predicting pN0 disease in the testing cohort and a non-pure ground glass nodule(non-pGGN)testing cohort,respectively.No significant difference was detected between the testing cohort and the non-pGGN testing cohort(P=0.622).The precisions of this model for predicting pN0 disease were 0.979(95%CI:0.963-0.995)and 0.983(95%CI:0.967-0.998)in the testing cohort and the non-pGGN testing cohort,respectively.The deep learning model achieved AUCs of 0.848(95%CI:0.798-0.898)and 0.831(95%CI:0.776-0.887)for predicting pN2 disease in the testing cohort and the non-pGGN testing cohort,respectively.No significant difference was detected between the testing cohort and the non-pGGN testing cohort(P=0.657).The recalls of this model for predicting pN2 disease were 0.903(95%CI:0.870-0.936)and 0.931(95%CI:0.901-0.961)in the testing cohort and the non-pGGN testing cohort,respectively.Conclusions:The superior performance of the deep learning model will help to target the extension of lymph node dissection and reduce the ineffective lymph node dissection in early-stage lung adenocarcinoma patients. 展开更多
关键词 Lung neoplasm ADENOCARCINOMA Clinical stage ia Deep learning Lymph node status
下载PDF
在艺术中汲取活力 东京LEAFMANIA Yoyogi Uehara商店
15
作者 《室内设计与装修》 2024年第5期74-77,共4页
LEAFM ANIA的第二家店铺位于东京台东区(Taito Ward)CABO综合大楼的一层和二层。CABO综合大楼位于Yoyogi-Uehara车站旁,2023年刚建成,是一个集合了办公、住宅和娱乐设施于一体的多功能综合性大楼。LEAFM AN IA兼具零售、画廊和茶室双重... LEAFM ANIA的第二家店铺位于东京台东区(Taito Ward)CABO综合大楼的一层和二层。CABO综合大楼位于Yoyogi-Uehara车站旁,2023年刚建成,是一个集合了办公、住宅和娱乐设施于一体的多功能综合性大楼。LEAFM AN IA兼具零售、画廊和茶室双重功能,2层的结构为其分区提供了有利的条件,将动与静、冷清与热闹、分散与聚集自然地区分开来。 展开更多
关键词 综合大楼 综合性大楼 娱乐设施 动与静 CAB ia 双重功能 东京
下载PDF
基于改进的SAC-IA-SICP点云配准方法研究 被引量:4
16
作者 田应仲 侯玉琴 +2 位作者 李龙 李明 韦庆玥 《计量与测试技术》 2023年第1期26-30,共5页
为了改善传统ICP算法迭代误差大、配准精度低的问题,本文提出一种基于采样一致性配准算法(Sample Consensus Initial Aligment,SAC-IA)初始匹配与改进迭代最近点(Iterative Closet Point,ICP)精配准相结合的配准方法。首先采用SAC-IA进... 为了改善传统ICP算法迭代误差大、配准精度低的问题,本文提出一种基于采样一致性配准算法(Sample Consensus Initial Aligment,SAC-IA)初始匹配与改进迭代最近点(Iterative Closet Point,ICP)精配准相结合的配准方法。首先采用SAC-IA进行初始配准,然后将一种对称的目标函数引入ICP算法,提高ICP算法收敛性,并用于点云精配准。实验结果表明,本文方法的配准精度较ICP算法提升了93.00%,时效性提高了15.20%,表明SAC-IA-SICP配准方法可靠性较高。 展开更多
关键词 点云配准 采样一致性配准 迭代最近点 目标函数
下载PDF
增量式光学编码器IAS信号误差建模及补偿 被引量:2
17
作者 尹兴超 郭瑜 +2 位作者 樊家伟 邹翔 陈鑫 《仪器仪表学报》 EI CAS CSCD 北大核心 2023年第2期50-58,共9页
增量式光学编码器在制造与安装的过程中不可避免的会出现刻线误差和细分误差,这些误差会降低角度测量的精度并导致瞬时角速度(IAS)信号波动,研究刻线与细分误差的补偿途径有重要意义,但现有方法存在误差补偿效率低,不易现场应用等局限... 增量式光学编码器在制造与安装的过程中不可避免的会出现刻线误差和细分误差,这些误差会降低角度测量的精度并导致瞬时角速度(IAS)信号波动,研究刻线与细分误差的补偿途径有重要意义,但现有方法存在误差补偿效率低,不易现场应用等局限。针对上述问题,本文首先对增量式光学编码器的刻线误差与细分误差进行分析并建立误差模型,揭示了刻线误差、细分误差与IAS信号波动之间的联系。在此基础上提出了一种使用IAS信号对增量式光学编码器刻线与细分误差进行补偿的方法,该方法具有效率高、无需对编码器进行改装等优点。通过仿真分析对本文所建立的误差模型的正确性与误差估计方法的可行性进行了验证,并在RV传动实验台上对伺服电机末端的增量式光学编码器进行刻线与细分误差补偿,最后使用光学旋转平台对增量式光学编码器误差进行测量,通过对比分析验证了本文所提方法的有效性。 展开更多
关键词 增量式光学编码器 iaS信号 刻线误差 细分误差 误差补偿
原文传递
Hepatitis C virus antigens enzyme immunoassay for one-step diagnosis of hepatitis C virus coinfection in human immunodeficiency virus infected individuals 被引量:1
18
作者 Ke-Qin Hu Wei Cui +1 位作者 Susan D Rouster Kenneth E Sherman 《World Journal of Hepatology》 CAS 2019年第5期442-449,共8页
BACKGROUND Current diagnosis of hepatitis C virus(HCV)infection requires two sequential steps:testing for anti-HCV followed by HCV RNA PCR to confirm viremia.We have developed a highly sensitive and specific HCV-antig... BACKGROUND Current diagnosis of hepatitis C virus(HCV)infection requires two sequential steps:testing for anti-HCV followed by HCV RNA PCR to confirm viremia.We have developed a highly sensitive and specific HCV-antigens enzyme immunoassay(HCV-Ags EIA)for one-step diagnosis of viremic HCV infection.AIM To assess the clinical application of the HCV-Ags EIA in one-step diagnosis of viremic HCV infection in human immunodeficiency virus(HIV)-coinfected individuals.METHODS The study blindly tested HCV-Ags EIA for its performance in one-step diagnosing viremic HCV infection in 147 sera:10 without HCV or HIV infection;54 with viremic HCV monoinfection;38 with viremic HCV/HIV coinfection;and 45 with viremic HCV and non-viremic HIV coinfection.RESULTS Upon decoding,it was 100%accordance of HCV-Ags EIA to HCV infection status by HCV RNA PCR test.In five sera with HCV infection,HCV RNA was as low as 50-59 IU/mL,and four out of five tested positive for HCV-Ags EIA.Likewise,it was also 100%accordance of HCV-Ags EIA to HCV infection status by HCV RNA PCR in 83 sera with HCV and HIV coinfection,regardless if HIV infection was active or not.CONCLUSION The modified HCV-Ags EIA has a lower detection limit equivalent to serum HCV RNA levels of approximately 100 IU/mL.It is highly sensitive and specific in the setting of HIV coinfection,regardless of HIV infection status and CD4 count.These data support the clinical application of the HCV-Ags EIA in one-step diagnosis of HCV infection in HIV-infected individuals. 展开更多
关键词 HEPATITIS C VIRUS HEPATITIS C VIRUS ANTIGENS HEPATITIS C VIRUS core antigen HEPATITIS C VIRUS DiaGNOSTIC test DiaGNOSTIC assay Enzyme immunoassay
下载PDF
Quantum Dot Nanobeads-Labelled Lateral Flow Immunoassay Strip for Rapid and Sensitive Detection of Salmonella Typhimurium Based on Strand Displacement Loop-Mediated Isothermal Amplification 被引量:2
19
作者 Yuting Shang Shuzhen Cai +10 位作者 Qinghua Ye Qingping Wu Yanna Shao Xiaoying Qu Xinran Xiang Baoqing Zhou Yu Ding Moutong Chen Liang Xue Honghui Zhu Jumei Zhang 《Engineering》 SCIE EI CAS 2022年第12期62-70,共9页
Rapid,sensitive,point-of-care detection of pathogenic bacteria is important for food safety.In this study,we developed a novel quantum dot nanobeads-labelled lateral flow immunoassay strip(QBs-labelled LFIAS)combined ... Rapid,sensitive,point-of-care detection of pathogenic bacteria is important for food safety.In this study,we developed a novel quantum dot nanobeads-labelled lateral flow immunoassay strip(QBs-labelled LFIAS)combined with strand displacement loop-mediated isothermal amplification(SD-LAMP)for quantitative Salmonella Typhimurium(ST)detection.Quantum dot nanobeads(QBs)served as fluorescence reporters,providing good detection efficiency.The customizable strand displacement(SD)probe was used in LAMP to improve the specificity of the method and prevent by-product capture.Detection was based on a sandwich immunoassay.A fluorescence strip reader measured the fluorescence intensity(FI)of the test(T)line and control(C)line.The linear detection range of the strip was 10^(2)–10^(8) colony forming units(CFU)·mL^(-1).The visual limit of detection was 10^(3) CFU·mL^(-1),indicating that the system was ten-fold more sensitive than AuNPs-labelled test strips.ST specificity was analyzed in accordance with agarose gel outputs of polymerase chain reaction(PCR)and SD-LAMP.We detected ST in foods with an acceptable recovery of 85%–110%.The method is rapid,simple,almost equipment-free,and suitable for bacterial detection in foods and for clinical diagnosis. 展开更多
关键词 Salmonella Typhimurium Quantum dot nanobeads Lateral flow immunoassay strip Loop-mediated isothermal amplification Strand displacement probe
下载PDF
CMIA、TPPA与TRUST检测梅毒的临床应用 被引量:2
20
作者 支张卓玛 尼玛顿珠 +3 位作者 扎西央宗 益西措姆 詹明君 巴桑央吉 《标记免疫分析与临床》 CAS 2023年第7期1217-1219,共3页
目的通过比较化学发光微粒子免疫分析(CMIA)、梅毒颗粒凝集试验(TPPA)与甲苯胺红不加热血清试验(TRUST)3种实验室检测梅毒的方法,分析3种检测方法的侧重方向与优缺点,评价3种方法在筛查梅毒特异性抗体中的临床应用价值。方法选取2022年... 目的通过比较化学发光微粒子免疫分析(CMIA)、梅毒颗粒凝集试验(TPPA)与甲苯胺红不加热血清试验(TRUST)3种实验室检测梅毒的方法,分析3种检测方法的侧重方向与优缺点,评价3种方法在筛查梅毒特异性抗体中的临床应用价值。方法选取2022年在西藏自治区人民医院接受梅毒检测的627例受检者作为研究对象,同时采集所有受检者3管静脉血,采集当日采用CMIA法、TPPA试验和TRUST试验进行梅毒检测。观察3种方法的检测结果,计算结果的一致性与阴阳符合率,对计算结果进行分析。结果CMIA阳性率66.83%,TPPA阳性率59.81%,TRUST阳性率21.05%;3种方法结果一致率为52.63%;CMIA法与TPPA法检测结果一致性为91.07%;TPPA法与CMIA法阳性符合率98.40%,阴性符合率80.16%,TPPA法与TRUST法阳性符合率34.93%,阴性符合率99.60%。结论CMIA法存在较多假阳性,适合应用到梅毒筛查试验;TPPA法特异性好,准确性高,适用于确诊;TRUST法灵敏度较低,适合用来检测病程和治疗效果;3种方法联合检测可以使诊断更加准确。 展开更多
关键词 梅毒抗体 化学发光微粒子免疫分析(CMia) 梅毒颗粒凝集试验(TPPA) 甲苯胺红不加热血清试验(TRUST)
下载PDF
上一页 1 2 250 下一页 到第