期刊文献+
共找到182,816篇文章
< 1 2 250 >
每页显示 20 50 100
Meta-analysis of the efficacy of volar plate internal fixation versus closed reduction and external fixation in the treatment of adult distal radius fractures
1
作者 CHEN Jian-ge ZHANG Hai-ning +4 位作者 ZHAO Hong-zhou LIU Ming-jun XING Jia-hui WANG Ping WANG Wei-min 《Journal of Hainan Medical University》 CAS 2023年第19期44-56,共13页
Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The ... Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The databases of CNKI,Wanfang,Weipu,Chinese biomedical literature,Pubmed,Embase,and Cochrane Library were retrieved,and the randomized controlled studies that directly compared the efficacy of plate internal fixation and closed reduction external fixation in the treatment of distal radius fractures published publicly from the establishment of the database to April 2023 were collected.The two researchers independently screened the retrieved literature according to the inclusion and exclusion criteria,extracted data,used Cochrane risk bias assessment tool for quality assessment,and used RevMan 5.4 software for meta analysis.Results:A total of 10 randomized controlled trials were included,all of which were in English.There were 1042 patients in total,and 9 of them were rated as low risk.Meta analysis results showed that one year after the treatment of distal radius fracture with volar locking plate internal fixation,DASH score[MD=-5.64,95%CI(-7.21,-4.06),P<0.00001];One year later,PRWE score[MD=-5.90,95%CI(-8.88,-2.92),P=0.001];Palm flexion[MD=5.92,95%CI(1.29,10.55),P=0.01];Pronation[MD=2.48,95%CI(0.59,4.36),P=0.01];Postrotation[MD=4.73,95%CI(2.15,7.31),P=0.0003];Grip strength[MD=0.61,95%CI(0.12,1.10),P=0.02];palmar tilt angle[MD=9.84,95%CI(5.66,14.02),P<0.00001];Radial inclination[MD=4.33,95%CI(2.97,5.69),P<0.00001]was superior to closed reduction plaster or splint external fixation.One year later,the European Five dimensional Health Scale(EQ-5D-5L)score[MD=0.02,95%CI(-0.01,0.05),P=0.27];Back extension[MD=2.22,95%CI(-4.15,8.59),P=0.49];Ulnar deviation[MD=3.49,95%CI(-0.80,7.78),P=0.11];Radial deviation[MD=2.05,95%CI(-2.39,6.50),P=0.37];Ulnar variance[MD=-1.14,95%CI(-3.16,0.88),P=0.27];There was no significant difference in complications[MD=0.77,95%CI(0.54,1.10),P=0.16](P>0.05).Conclusion:Based on the current clinical data,internal fixation with volar locking plate is more conducive to mid-term DASH score and grip strength recovery than closed reduction plaster or splint external fixation,but there is no significant difference in the quality of life and complications of patients.For adult distal radius fractures,surgical indications should be carefully grasped,and non operative treatment should be given priority. 展开更多
关键词 Volar plate internal fixation Closed reduction External fixation PLASTER SPLINT Distal radius fracture Meta analysis
下载PDF
Open reduction and internal fixation for radial head fractures: A prospective observational study 被引量:4
2
作者 Imran Khan Mangi Arslan Ahmed Abro +4 位作者 Muhammad Naveed Memon Shahjahan Siyal Naveed Khan Nouman Memon Muhammad Kazim Rahim Najjad 《Journal of Acute Disease》 2020年第4期166-169,共4页
Objective: To evaluate the effect of open reduction and internal fixation on radial head fracture and assess the post-operative function. Methods: This prospective observational study was conducted from June 2016 to J... Objective: To evaluate the effect of open reduction and internal fixation on radial head fracture and assess the post-operative function. Methods: This prospective observational study was conducted from June 2016 to July 2017 at Liaquat National Hospital and Medical College, Karachi. Altogether, 28 patients with radial head and neck fractures were enrolled in our study. These patients were admitted to the hospital and their fractures were fixed with open reduction and internal fixation. Baseline information of the patients was collected, and patient-rated elbow evaluation scores were calculated. Results: Out of the 28 patients, 21 were male and 7 were female. Besides, 16 fractures were on the right side and 12 were on the left side and 17 involving the dominant hands. In addition, 8 patients had Mason type Ⅱ fracture and 20 had Mason type Ⅲ fracture. The mean age of patients was (31.0 ± 8.0) years, and the mean follow-up is (1.2 ± 0.5) years. The mean average patient-rated elbow evaluation scores were (27.64 ± 1.60) at 1-year follow-up. Conclusions:The majority of the patients who had radial head fractures and treated by open reduction and internal fixation have attained an excellent range of motion postoperatively. 展开更多
关键词 Radial head fractures Open reduction and internal fixation Functional outcome
下载PDF
Functional Outcomes of Traumatic Complex Acetabulum Fractures with Open Reduction and Internal Fixation: 200 Cases 被引量:3
3
作者 Keykhosro Mardanpour Mahtab Rahbar +2 位作者 Maryam Rahbar Nyosha Mardanpour Sourena Mardanpour 《Open Journal of Orthopedics》 2016年第12期363-377,共15页
Objective: Acetabular fractures are common injuries in Iran. We assess the functional outcome of open reduction and internal fixation management of displaced Complex acetabular fractures. Materials and Methods: We ana... Objective: Acetabular fractures are common injuries in Iran. We assess the functional outcome of open reduction and internal fixation management of displaced Complex acetabular fractures. Materials and Methods: We analyzed a case series of patients with open reduction and internal fixation (ORIF) for complex acetabular fractures. Two hundred patients (132 men, 68 women) in four age groups including with a mean age of 43.39 ± 6.18 years (range 20 - 59 years) and a mean follow-up of 82.34 ± 12.48 months (range 18 - 109 months) met the inclusion criteria. Functional outcome at final follow-up was graded assessed according to Harris score. Factors affecting were defined. Results: Anatomic reduction was achieved in 192 hips, imperfect in 8 and poor in none. Radiological outcome revealed excellent results in 128 (64%) hips, good in eight, fair in five and none in poor. Harris score were excellent in 139 (69.5%) hips, good in 43 (21.5%) and fair in 18 (9%) and poor in none. The anatomical reduction results had a favorable final functional outcome. (0.003) However, BMI (P Conclusion: Optimal functional and radiological outcomes have been achieved with anatomic postoperative reduction. Also experience of specialist, on time surgery and good recovery lead to receiving excellent functional outcome with at least complications. 展开更多
关键词 Complex Acetabular Fracture internal fixation Open Reduction OUTCOME
下载PDF
Modified Closed Reduction and Percutaneous Kirschner Wires Internal Fixation for Treatment of Supracondylar Humerus Fractures in Children 被引量:4
4
作者 Shu-bin WANG Bin-hui LIN +4 位作者 Wei LIU Guo-jun WEI Zong-guang LI Nai-chun YU Guang-rong JI 《Current Medical Science》 2021年第4期777-781,共5页
Objective Supracondylar humerus fractures are the most frequent fractures of the paediatric elbow.The present study introduced a modified surgical procedure for treatment of supracondylar humerus fractures in children... Objective Supracondylar humerus fractures are the most frequent fractures of the paediatric elbow.The present study introduced a modified surgical procedure for treatment of supracondylar humerus fractures in children.Methods From February 2015 to August 2019,73 patients with Gartland’s type II and III supracondylar fractures were treated with this modified method.Totally,68 of all patients were followed up for 3–12 months(mean 8.25 months).The evaluation results included fracture nonunion,ulnar nerve injury,pin track infection,carrying angle and elbow joint Flynn score.Results The results showed that bone union was observed in all children,one case had an iatrogenic ulnar nerve injury,and the symptoms were completely relieved in 4 months after removing of the medial-side pin.All children had no cubitus varus deformity and no pin track infection,and the rate of satisfactory results according to Flynn’s criteria score was 100%.Conclusion The modified closed reduction and Kirschner wires internal fixation could effectively reduce the rate of open reduction,the risk of iatrogenic ulnar nerve injury,and the incidence of cubitus varus deformity in treatment of supracondylar humerus fractures in children. 展开更多
关键词 supracondylar humerus fractures closed reduction Kirschner wires internal fixation surgical method
下载PDF
Clinical Effect of Posterior Internal Fixation and Fusion in the Treatment of Thoracolumbar Fractures 被引量:1
5
作者 Tianhui Liu Jianmin Cui 《Journal of Clinical and Nursing Research》 2021年第2期38-41,共4页
Objective:To evaluate the clinical effect of posterior internal fixation and fusion in the treatment of thoracolumbar fractures.Methods:36 patients with thoracolumbar fractures from January 2018 to December 2020 were ... Objective:To evaluate the clinical effect of posterior internal fixation and fusion in the treatment of thoracolumbar fractures.Methods:36 patients with thoracolumbar fractures from January 2018 to December 2020 were selected and divided into study group and control group according to the random number table model.The control group was treated with anterior internal fixation,while the study group was treated with posterior internal fixation and fusion.The indexes of the two groups were compared and analyzed.Results:Compared with the operation related indexes of the two groups,the study group had more advantages(P<0.05);The postoperative kyphosis Cobb angle,height of anterior and posterior vertebral body,wedge index of the two groups were better than those before operation(P<0.05),and there was no significant difference between the two groups(P>0.05);There was no significant difference between the two groups(P>0.05).Conclusion:The clinical effect of posterior internal fixation and fusion in the treatment of thoracolumbar fractures is significant,and the body damage is slight,which is worthy of comprehensive promotion. 展开更多
关键词 Thoracolumbar fracture of spine The back road internal fixation and fusion
下载PDF
Internal fixation and unicompartmental knee arthroplasty for an elderly patient with patellar fracture and anteromedial osteoarthritis:A case report
6
作者 Shao-Kui Nan Hai-Feng Li +2 位作者 Dong Zhang Jian-Ning Lin Li-Sheng Hou 《World Journal of Clinical Cases》 SCIE 2021年第16期3919-3926,共8页
BACKGROUND Open reduction and internal fixation(ORIF)is the traditional surgical treatment for patellar fractures,and unicompartmental knee arthroplasty(UKA),especially Oxford UKA,has been increasingly used in patient... BACKGROUND Open reduction and internal fixation(ORIF)is the traditional surgical treatment for patellar fractures,and unicompartmental knee arthroplasty(UKA),especially Oxford UKA,has been increasingly used in patients with medial knee osteoarthritis(OA).However,the process of choosing treatment for patients with both patellar fractures and anteromedial knee OA remains unclear.We present the case of a patient with a patellar fracture and anteromedial OA.CASE SUMMARY We present the case of a 72-year-old woman with a history of bilateral medial compartment OA of the knees and a right Oxford UKA.She also experienced a recent left patellar fracture.ORIF and Oxford UKA were performed in a single stage.The patient showed excellent postoperative clinical results.CONCLUSION ORIF and Oxford UKA can be performed simultaneously for patients with patellar fracture and anteromedial OA on the same knee. 展开更多
关键词 Patellar fracture Anteromedial osteoarthritis Open reduction and internal fixation Unicompartmental knee arthroplasty Elderly patient Case report
下载PDF
Early Rehabilitation of Orthopedic Internal Fixation Removal in DaytimeWard
7
作者 Lanlan Ni Lanzheng Bian +2 位作者 Rugang Lu Ting Chen Jinyue Xia 《Computer Systems Science & Engineering》 SCIE EI 2022年第10期219-231,共13页
Children's fractures are very common,and many children's fractures need internal fixation.When the children are treated and recovered,it needs to be internally fixed and then taken out.With the development of ... Children's fractures are very common,and many children's fractures need internal fixation.When the children are treated and recovered,it needs to be internally fixed and then taken out.With the development of internal fixation materials,the research of surgical methods and the improvement of surgical skills,postoperative removal of orthopedic surgery patients has gradually been included in daytime surgery.While ensuring the safety of children's surgery,it is necessary to shorten the postoperative limb and joint function recovery time,promote the recovery of limb and joint function,the healing of wounds and bones,and reduce the occurrence of these complications.In order to reduce the occurrence of these complications,carry out early rehabilitation education and development early rehabilitation training is very necessary.This paper puts forward the concept of early rehabilitation based on shared decision model,in which doctors,nurses,children and family members participate in the treatment of children before,during and after operation.The effect of early rehabilitation education in the daytime ward after removal of internal fixation was examined.Moreover,through the analysis of the control trial also confirmed that the clinical effect of early rehabilitation in improving and optimizing the rehabilitation of fracture in children is significant. 展开更多
关键词 FRACTURES internal fixation daytime surgery REHABILITATION
下载PDF
A Study of the Mechanical Characteristics of a Mandibular Parasymphyseal Fracture with Internal Fixation Device Subject to Variable Bite Forces: Finite Element Analysis
8
作者 Victor Caraveo Scott Lovald Tariq Khraishi 《Journal of Biosciences and Medicines》 2021年第4期158-178,共21页
In recent times, research into mandibular fracture has gained momentum from advances in scanning techniques, software/algorithm developments and improvements, and numerical structural modeling using the finite-element... In recent times, research into mandibular fracture has gained momentum from advances in scanning techniques, software/algorithm developments and improvements, and numerical structural modeling using the finite-element method (FEM). In this work, the FEM is used to model a mandibular fracture (using an inhomogeneous and orthotropic jaw model) simulating the effect of different bite tasks/forces on the stability of the fixated fracture. Specifically, bilateral and unilateral clenches (using muscle data) were studied using a low-profile 3D 4 × 2 hole mini-plate deployed for fracture fixation. Here, the mandible bone was treated as orthotropic and spatially inhomogeneous. Although the results of stress and displacement analyses, for this fixation hardware, indicate sufficient fixation under normal biting conditions, the results show that the unilateral and ipsilateral bites develop, in general, the highest stresses or displacements. Such results can guide post-surgery recommendation on bite behavior. 展开更多
关键词 MANDIBLE Mandibular Fracture internal fixation Finite-Element Modeling Bite Forces
下载PDF
Chinese traditional medicine rehabilitative treatment of femoral neck fracture after screw thread needle internal fixation
9
作者 高广升 李凤辉 《中国组织工程研究与临床康复》 CAS CSCD 2001年第24期154-155,共2页
关键词 Chinese traditional medicine rehabilitative treatment of femoral neck fracture after screw thread needle internal fixation TIME
下载PDF
Internal Fixation of Gunshot Induced Fractures in Civilians: Anatomic and Functional Results of a Standard Protocol at an Urban Trauma Center
10
作者 Anani Abalo Atsi Walla +3 位作者 Gamal Ayouba Yaovi Yannick Dellanh Kosivi Fortey Assang Dossim 《Open Journal of Orthopedics》 2016年第3期63-70,共8页
Introduction: Despite extensive experience with civilian gunshot fractures or wounds, no consensus exists on a standard protocol to manage these injuries. Many authors recommended immediate debridement, but the optima... Introduction: Despite extensive experience with civilian gunshot fractures or wounds, no consensus exists on a standard protocol to manage these injuries. Many authors recommended immediate debridement, but the optimal timing of internal fixation and the use of antibiotic have not been determined. The purpose of this paper is to present and discuss our experience. Material and methods: In January 2007, a treatment protocol was put in place for the evaluation and management of fractured extremities resulting from civilian gunshot wounds. Sixty-three patients with 64 fractures had been managed by this protocol for gunshot fractures between January 2005 and January 2012. There were 56 male and seven female. Their mean age was 33.1 years (range: 17 - 61 years). Thirteen patients (20.6%) were able to provide a description of the weapon. Only 15 patients had entry and exit wounds. The mean follow-up period was 27 (range, 20 - 58) months. The main factors assessed were the surgical site infection, the fracture union and the functional status. Results: Out of the 63 patients, 14 patients developed a wound infection (five superficial and seven deep infections). Wound infection was significantly associated with associated injuries (p = 0.0388), fractures sites requiring fixation (p = 0.024), the fracture pattern (p = 0.0412), operative modalities (p = 0.0400). There were nine cases (14.1%) of fracture non-union. The mean time to union was 15 weeks (range: 5 - 32 weeks). Five patients developed chronics osteomyelitis. The average SMFA score for all of the patients was 23.8 (range: 0 - 56.3). The mean dysfunctional and bother indexes were 18.3 (range: 0 - 52.7) and 22.6 (range: 0 - 66.1), respectively. The SMFA total score and dysfunction index had a significant correlation based on presence or absence of associated injuries (p < 0.0001). But bother index did not show the same correlation (p = 0.452). The average length of hospital stay was 11.3 days (range: 3 - 64). Conclusion: In civilian’s gunshot induced fractures, internal fixation can be made according to standard protocol, with acceptable result. 展开更多
关键词 FRACTURE Gunshot Fracture internal fixation Wound Infection Surgical Treatment
下载PDF
Observation on the Efficacy of Autologous Blood Transfusion Combined with Controlled Hypotension in Patients with Spinal Internal Fixation during the Outbreak of New Coronavirus Pneumonia in Western Guangxi (in Guixi)
11
作者 Chengkua Huang Guosheng Su +3 位作者 Yong Zhao Chunxian Lu Sheng Nong Xiaohua Huang 《Open Journal of Blood Diseases》 2021年第1期15-23,共9页
<strong>Objective: </strong>To explore the therapeutic effect of autologous blood reinfusion combined with controlled hypotension in surgical spinal fixation during the outbreak of COVID-19. <strong>... <strong>Objective: </strong>To explore the therapeutic effect of autologous blood reinfusion combined with controlled hypotension in surgical spinal fixation during the outbreak of COVID-19. <strong>Methods: </strong>30 patients with spinal internal fixation autologous blood transfusion combined with controlled hypotension were selected as the subjects during the epidemic period from December 2019 to June 2020 in our hospital and during the operation, on the basis of routine blood pressure reduction, the American Haemonetice Corporation autologous blood continuous reinfusion system was used to infuse the blood recovered during the operation to the patient through filtration and other procedures. <strong>Results:</strong> 30 patients had no complications such as fever and hemolysis;And after the operation, the tube was dialed according to the drainage volume, the cervical thoracic and lumbar brace was customized, and the patient walked on the ground for one week;After no abnormalities, the patient was discharged. Intraoperative comparison of white blood cells (WBC), red blood cells (RBC), red blood cell pressure (HCT), hemoglobin (HGB), and coagulation time (PT) of patients with autologous blood before and after transfusion showed statistically significant differences before and after surgery (P < 0.001). <strong>Conclusion:</strong> During the new coronavirus pneumonia epidemic, the internal fixation of spinal surgery used a recovery machine to collect intraoperative blood for reinfusion. Intraoperative antihypertensive drugs were used to control blood pressure within a certain safe range. The postoperative clinical observation effect was significant and safe;especially at present the clinical significance during the epidemic was significant. 展开更多
关键词 New Coronavirus Pneumonia Spinal internal fixation Surgery Autologous Blood Reinfusion Controlled Hypotension Curative Effect
下载PDF
关于Rigid Internal Fixation一词译法和应用的说明
12
作者 顾晓明 《中国口腔颌面外科杂志》 CAS 2004年第1期21-21,共1页
关键词 igid internal fixation RIF 内固定 口腔颌面部 力学设计
下载PDF
MIPPO technique and LCP internal fixation for open tibial shaft fractures
13
作者 邹海兵 《外科研究与新技术》 2011年第2期107-107,共1页
Objective To explore the efficacy of minimally invasive percutaneous plate osteosynthesis (MIPPO) technique and locking compression plate (LCP) for open tibial shaft fractures.Methods From March 2005 to May 2009,16 ca... Objective To explore the efficacy of minimally invasive percutaneous plate osteosynthesis (MIPPO) technique and locking compression plate (LCP) for open tibial shaft fractures.Methods From March 2005 to May 2009,16 cases with open tibial 展开更多
关键词 MIPPO technique and LCP internal fixation for open tibial shaft fractures LCP
下载PDF
Dynamic external fixator combined with limited internal fixation for Pilon reactures
14
作者 李灿杨 《外科研究与新技术》 2011年第2期109-109,共1页
Objective To evaluate effects of manipulative reduction,dynamic external fixator combined with limited internal fixation for the treatment of Pilon fractures.Methods From January 2007 to June 2009,manipulative reducti... Objective To evaluate effects of manipulative reduction,dynamic external fixator combined with limited internal fixation for the treatment of Pilon fractures.Methods From January 2007 to June 2009,manipulative reduction,dynamic external 展开更多
关键词 Dynamic external fixator combined with limited internal fixation for Pilon reactures
下载PDF
Association between anterior internal fixation systems and post-operative lateral angulation in thoracolumbar fractures
15
作者 马立泰 《外科研究与新技术》 2011年第2期106-106,共1页
Objective To explore the effects of the anterior internal fixation systems on the post-operative lateral angulation in treatment of thoracolumbar fractures.Methods A retrospective study was done to analyze the 172 pat... Objective To explore the effects of the anterior internal fixation systems on the post-operative lateral angulation in treatment of thoracolumbar fractures.Methods A retrospective study was done to analyze the 172 patients who had 展开更多
关键词 Association between anterior internal fixation systems and post-operative lateral angulation in thoracolumbar fractures
下载PDF
The application of C1-C2 pedicle screw internal fixation on the upper cervical diseases of children
16
作者 夏虹 《外科研究与新技术》 2011年第2期80-80,共1页
Objective To report five cases of puerile (【9 years) atlantoaxial instability which underwent C1-C2 pedicle screw internal fixation by posterior approach,and to introduce the surgical technique and the key point
关键词 The application of C1-C2 pedicle screw internal fixation on the upper cervical diseases of children
下载PDF
Clinical application of improved 2D computer-assisted fluoroscopic navigation through simulating a 3D vertebrae image to guide pedicle screw internal fixation
17
作者 刘恩志 《外科研究与新技术》 2011年第2期94-94,共1页
Objective To study the effect of using improved 2D computer-assisted fluoroscopic navigation through simulating 3D vertebrae image to guide pedicle screw internal fixation.Methods Posterior pedicle screw internal fixa... Objective To study the effect of using improved 2D computer-assisted fluoroscopic navigation through simulating 3D vertebrae image to guide pedicle screw internal fixation.Methods Posterior pedicle screw internal fixation,distraction 展开更多
关键词 Clinical application of improved 2D computer-assisted fluoroscopic navigation through simulating a 3D vertebrae image to guide pedicle screw internal fixation
下载PDF
Usage of buttress plate internal fixation associated with autografting of fibula and iliac bone for the treatment of distal femoral C_3 type fracture
18
作者 李衡 《外科研究与新技术》 2005年第3期176-177,共2页
To assess the effect of using buttress plate associated with antografting of fibula and iliac bone for the treatment of distal femoral C3 type fracture.Methods Seventeen cases of distal femoral C3 type fracture usin... To assess the effect of using buttress plate associated with antografting of fibula and iliac bone for the treatment of distal femoral C3 type fracture.Methods Seventeen cases of distal femoral C3 type fracture using buttress plate associated with antografting of fibula and iliac bone were analyzed retrospectively.Results All cases were followed up for an average of 24 months(8~55 months).The average time of octets bridge forming were 4 months(3~5 months) while the average time for bone union were 8 months (6~14 months).According to Shelbourne rating system,result of all 18 cases were excellent and no malunion,infection were found.Conclusion Buttress plate associated with antografting of fibula and iliac bone is an effective alternative for the treatment of distal femoral C3 type fracture.It can provide more stable fixation to the bone and earlier functional exercises can be achieved.5 refs,3 figs,1 tab. 展开更多
关键词 Usage of buttress plate internal fixation associated with autografting of fibula and iliac bone for the treatment of distal femoral C3 type fracture
下载PDF
Application of internal fixation of steel-wire limited loop in early Achilles tendon rupture 被引量:10
19
作者 Zhe Chen Jia-Sen Wei +3 位作者 Zhao-Yang Hou Jiong Hu Yan-Guang Cao Qi-Xin Chen 《Asian Pacific Journal of Tropical Medicine》 SCIE CAS 2013年第11期902-907,共6页
Objective:To explore the clinical effect and safety of internal fixation of steel-wire limited loop in early Achilles tendon rupture.Methods:Seventy-six patients respectively with early transected and avulsed types of... Objective:To explore the clinical effect and safety of internal fixation of steel-wire limited loop in early Achilles tendon rupture.Methods:Seventy-six patients respectively with early transected and avulsed types of Achilles tendon rupture were selected and treated with internal fixation of steel-wire limited loop.The patients began to take exercise for their lower limbs through continous passive motion as early as possible after surgical repair,and the loops were removed after 3-5 months.Six months later,the condition of complications including Achilles tendon re-rupture,wound fistula,wound infection and skin necrosis,cutaneous sensation in sural nerve dominance region,time back to preinjury work or learning as well as time to physical activities were observed.One year later,the therapeutic effect was evaluated,and the maximum circumferences of bilateral legs and raptured plane circumferences of Achilles tendon were measured.Results:The wound of all patients healed well,no complications like Achilles tendon re-rupture,wound fistula,wound infection and skin necrosis occured,and the cutaneous sensation in sural nerve dominance region was normal.The mean time back to preinjury work or learning as well as to pysical activities of all patients were respectively 10 and 22 weeks.Seventy out of 76 patients(92.1%) achieved an excellent effect,and 6(7.9%) good effect.The excellent and good rate came up to 100%.The maximum circumference in the affected leg decreased to 2 mm averagely compared with the offside,while the ruptured plane circumferences of Achilles tendon in the affected side increased to 2.2 mm compared with the offside.Conclusions:Kor early Achilles tendon rupture,internal fixation of steel-wire limited loop can recover the ankle function better,return to the preinjury state in the shortest lime,and has few complications. 展开更多
关键词 ACHILLES TENDON rupture Steel-wire LIMITED LOOP internal fixation ANKLE function
下载PDF
Three-dimensional finite element analysis with different internal fixation methods through the anterior approach 被引量:2
20
作者 Xian-Jin Xie Sheng-Lu Cao +2 位作者 Kai Tong Zi-Yi Zhong Gang Wang 《World Journal of Clinical Cases》 SCIE 2021年第8期1814-1826,共13页
BACKGROUND With the modernization of society and transportation in the last decades in China,the incidence of high-energy trauma increased sharply in China,including that of acetabular fractures.AIM To establish diffe... BACKGROUND With the modernization of society and transportation in the last decades in China,the incidence of high-energy trauma increased sharply in China,including that of acetabular fractures.AIM To establish different finite element models for acetabular posterior column fractures involving the quadrilateral area of the acetabulum.METHODS The three-dimensional models of the normal and fractured pelvis and the five internal fixations were established using the computed tomography data of the pelvis of a living volunteer.After the vertebral body model was inserted in the way of origin matching and all cancellous bones were copied using the duplicated cancellous bone model as the subtractive entity,the Boolean operation was performed on the pelvis model to obtain the model of the complete pelvis cortical and cancellous bones.RESULTS In the standing position,the maximum stress was 46.21 MPa.In the sitting position,the sacrum bore the simulated gravity load at the upper end.When comparing the five fixations,there were no significant differences in the stress mean values among groups(sitting:P=0.9794;standing:P=0.9741).In terms of displacement,the average displacement of the internal iliac plate group was smaller than that of the spring plate group(P=0.002),and no differences were observed between the other pairs of groups(all P>0.05).In the standing position,there were no significant differences in the mean value of displacement among the groups(P=0.2985).It can be seen from the stress nephogram of the internal fixations in different positions that the stress of the internal fixation was mainly concentrated in the fracture segment.CONCLUSION There were no significant differences among the fixations for acetabular posterior column fractures involving the quadrilateral area of the acetabulum. 展开更多
关键词 ACETABULUM Hip fractures ANALYSIS Finite element Fracture fixation Orthopedic fixation devices
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部