In order to improve the machining ac cu racy of spiral bevel gear,difference surface was adopted to characterize its gl obal form deviations quantifiably and correct its deviations.The theoretical to oth surface model...In order to improve the machining ac cu racy of spiral bevel gear,difference surface was adopted to characterize its gl obal form deviations quantifiably and correct its deviations.The theoretical to oth surface model of spiral bevel gear was built,and the actual tooth surface o f spiral bevel gear had been got by using latticed measurement.The equation of difference surface which can characterize the actual tooth surface deviation s was built by means of mathematical method in combination with measurement prin ciple.The quantitative mathematical relationship between the actual tooth surfa ce deviations of spiral bevel gear and the corrected values of the machine-sett ing parameters had been referred,and the theoretical correction formula of the global form deviations had been got by the least square method.Finally,the pinion of spiral bevel gear in the automobile rear axle has been set for an exam ple to account for the effectiveness of the deviation correction by use of the d ifference surface method.展开更多
An optical lattice clock based on 87Sr is built at National Institute of Metrology (NIM) of China. The systematic frequency shifts of the clock are evaluated with a total uncertainty of 2.3×10-16. To measure it...An optical lattice clock based on 87Sr is built at National Institute of Metrology (NIM) of China. The systematic frequency shifts of the clock are evaluated with a total uncertainty of 2.3×10-16. To measure its absolute frequency with respect to NIM's cesium fountain clock NIM5, the frequency of a flywheel H-maser of NIM5 is transferred to the Sr laboratory through a 50-kin-long fiber. reference frequency of this H-maser, is used for the optical this Sr clock is measured to be 429228004229873.7(1.4)Hz. A fiber optical frequency comb, phase-locked to the frequency measurement. The absolute frequency of展开更多
The tooth surface shape of hypoid gear is very complicated, and tooth surface accuracy of hypoid gear can be measured by using the latticed measurement and scanning measurement. Advantages and disadvantages of the two...The tooth surface shape of hypoid gear is very complicated, and tooth surface accuracy of hypoid gear can be measured by using the latticed measurement and scanning measurement. Advantages and disadvantages of the two measurement patterns are compared and application of their measurement data on hypoid gear's quality management is analyzed. How to use these measurement data to simulate the dynamical performance of hypoid gear is researched, and the intelligent predicton of the dynamical performance indexes of contact spot, root stress, vibration exciting forces and load distribution and hertz contact stress on the tooth surface are carried out. This research work has an important guiding sense to design and ma- chine hypoid gear with low vibration and noise.展开更多
Theory of uncertainty reasoning base on l-module of true value field,in this paper,an extended l-module was proposed,some properties and lattice measure were discussed,then the lattice integral on l-module was gained.
Aiming at the problem that the lattice feature exceeds the view field of the scanning electron microscope(SEM)measuring system,a new lattice measuring method is proposed based on integral imaging technology.When the s...Aiming at the problem that the lattice feature exceeds the view field of the scanning electron microscope(SEM)measuring system,a new lattice measuring method is proposed based on integral imaging technology.When the system works,the SEM measuring system is equivalent to an integral image acquisition system.Firstly,a lattice measuring method is researched based on integral imaging theory.Secondly,the system parameters are calibrated by the VLSI lattice standard.Finally,the value of the lattice standard to be tested is determined based on the calibration parameters and the lattice measuring algorithm.The experimental results show that,compared with the traditional electron microscope measurement method,the relative error of the measured value of the algorithm is maintained within 0.2%,with the same level of measurement accuracy,but it expands the field of view of the electron microscope measurement system,which is suitable for the measurement of samples under high magnification.展开更多
基金National Natural Science Foundation of China(No.50976108)
文摘In order to improve the machining ac cu racy of spiral bevel gear,difference surface was adopted to characterize its gl obal form deviations quantifiably and correct its deviations.The theoretical to oth surface model of spiral bevel gear was built,and the actual tooth surface o f spiral bevel gear had been got by using latticed measurement.The equation of difference surface which can characterize the actual tooth surface deviation s was built by means of mathematical method in combination with measurement prin ciple.The quantitative mathematical relationship between the actual tooth surfa ce deviations of spiral bevel gear and the corrected values of the machine-sett ing parameters had been referred,and the theoretical correction formula of the global form deviations had been got by the least square method.Finally,the pinion of spiral bevel gear in the automobile rear axle has been set for an exam ple to account for the effectiveness of the deviation correction by use of the d ifference surface method.
基金Supported by the National Natural Science Foundation of China under Grant Nos 91336212 and 91436104
文摘An optical lattice clock based on 87Sr is built at National Institute of Metrology (NIM) of China. The systematic frequency shifts of the clock are evaluated with a total uncertainty of 2.3×10-16. To measure its absolute frequency with respect to NIM's cesium fountain clock NIM5, the frequency of a flywheel H-maser of NIM5 is transferred to the Sr laboratory through a 50-kin-long fiber. reference frequency of this H-maser, is used for the optical this Sr clock is measured to be 429228004229873.7(1.4)Hz. A fiber optical frequency comb, phase-locked to the frequency measurement. The absolute frequency of
基金National Natural Science Foundation of China(No. 50976108)
文摘The tooth surface shape of hypoid gear is very complicated, and tooth surface accuracy of hypoid gear can be measured by using the latticed measurement and scanning measurement. Advantages and disadvantages of the two measurement patterns are compared and application of their measurement data on hypoid gear's quality management is analyzed. How to use these measurement data to simulate the dynamical performance of hypoid gear is researched, and the intelligent predicton of the dynamical performance indexes of contact spot, root stress, vibration exciting forces and load distribution and hertz contact stress on the tooth surface are carried out. This research work has an important guiding sense to design and ma- chine hypoid gear with low vibration and noise.
基金Supported by NSF of the Education Department of Henan Province(2009A110017)
文摘Theory of uncertainty reasoning base on l-module of true value field,in this paper,an extended l-module was proposed,some properties and lattice measure were discussed,then the lattice integral on l-module was gained.
基金supported by the National Key Research and Development Program(No.2019YFB2005503)。
文摘Aiming at the problem that the lattice feature exceeds the view field of the scanning electron microscope(SEM)measuring system,a new lattice measuring method is proposed based on integral imaging technology.When the system works,the SEM measuring system is equivalent to an integral image acquisition system.Firstly,a lattice measuring method is researched based on integral imaging theory.Secondly,the system parameters are calibrated by the VLSI lattice standard.Finally,the value of the lattice standard to be tested is determined based on the calibration parameters and the lattice measuring algorithm.The experimental results show that,compared with the traditional electron microscope measurement method,the relative error of the measured value of the algorithm is maintained within 0.2%,with the same level of measurement accuracy,but it expands the field of view of the electron microscope measurement system,which is suitable for the measurement of samples under high magnification.