Rice bacterial leaf brown spot disease caused by Pseudomonas syringae pv.syringae(Pss)is a major disease on rice.In recent years,Pss has emerged worldwide,seriously affecting rice production.It is very important to es...Rice bacterial leaf brown spot disease caused by Pseudomonas syringae pv.syringae(Pss)is a major disease on rice.In recent years,Pss has emerged worldwide,seriously affecting rice production.It is very important to establish a rapid detection method of Pss for the diagnosis and prevention of this disease.In order to robust and accurately diagnose the rice bacterial leaf brown spot disease in the field and laboratory,an assay system for the Pss was developed in this study,and the specific sequence of hrcN was used as the target,based on loop-mediated isothermal amplification(LAMP).The best detection system was MgSO 48 mmol·L^(-1),Bst DNA polymerase 8 U,dNTP 1.4 mmol·L^(-1),the ratio of internal and outer primers was 2:1,the reaction temperature was 63℃,the reaction time was 45 min,and the lowest sensitivity was 104 CFU·mL^(-1).This results provided an accurate and robust method for laboratory and field diagnosis of bacterial leaf brown spot disease of rice.展开更多
Loop-mediated isothermal amplification (LAMP) is a novel nucleic acid amplification method, which amplifies DNA with high specificity, sensitivity, rapidity and efficiency under isothermal conditions using a set of fo...Loop-mediated isothermal amplification (LAMP) is a novel nucleic acid amplification method, which amplifies DNA with high specificity, sensitivity, rapidity and efficiency under isothermal conditions using a set of four specially designed primers and a Bst DNA polymerase with strand displacement activity. The basic principle, characteristics, development of LAMP and its applications are summarized in this article.展开更多
Viral load measurements are an essential tool for the long-term clinical care of human immunodeficiency virus (HIV)-positive individuals. The gold standards in viral load instrumentation, however, are still too limi...Viral load measurements are an essential tool for the long-term clinical care of human immunodeficiency virus (HIV)-positive individuals. The gold standards in viral load instrumentation, however, are still too limited by their size, cost, and sophisticated operation for these measurements to be ubiquitous in remote settings with poor healthcare infrastructure, including parts of the world that are disproportionately affected by HIV infection. The challenge of developing a point-of-care platform capable of making viral load more accessible has been frequently approached but no solution has yet emerged that meets the practical requirements of low cost, portability, and ease-of-use. In this paper, we perform reverse-transcription loop-mediated isothermal amplification (RT-LAMP) on minimally processed HIV-spiked whole blood samples with a microfluidic and silicon microchip platform, and perform fluorescence measurements with a consumer smartphone. Our integrated assay shows amplification from as few as three viruses in a - 60 nL RT- LAMP droplet, corresponding to a whole blood concentration of 670 viruses per μL of whole blood. The technology contains greater power in a digital RT-LAMP approach that could be scaled up for the determination of viral load from a finger prick of blood in the clinical care of HIV-positive individuals. We demonstrate that all aspects of this viral load approach, from a drop of blood to imaging the RT-LAMP reaction, are compatible with lab-on-a-chip components and mobile instrumentation.展开更多
A real-time monitoring reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay was developed for the sensitive and specific detection of prototypic,prevalent North American porcine reproductive an...A real-time monitoring reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay was developed for the sensitive and specific detection of prototypic,prevalent North American porcine reproductive and respiratory syndrome virus (PRRSV) strains.As a higher sensitivity and specificity method than reverse transcription polymerase chain reaction (RT-PCR),the RT-LAMP method only used a turbidimeter,exhibited a detection limit corresponding to a 10-4 dilution of template RNA extracted from 250 μL of 105 of the 50% tissue culture infective dose (TCID50) of PRRSV-containing cells,and no cross-reactivity was observed with other related viruses including porcine circovirus type 2,swine influenza virus,porcine rotavirus and classical swine fever virus.From forty-two field samples,33 samples in the RT-LAMP assay was detected positive,whereas three of which were not detected by RT-PCR.Furthermore,in 33 strains of PRRSV,an identical detection rate was observed with the RT-LAMP assay to what were isolated using porcine alveolar macrophages.These findings demonstrated that the RT-LAMP assay has potential clinical applications for the detection of highly pathogenic PRRSV isolates,especially in developing countries.展开更多
A sensitive reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for human enterovirus 71 (EV71) and Coxsackievirus A16 (CVA16) infection was further evaluated. The one step reaction was perfor...A sensitive reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for human enterovirus 71 (EV71) and Coxsackievirus A16 (CVA16) infection was further evaluated. The one step reaction was performed in a single tube at 65?C for 45 min for EV71 and 35 min for CVA16. The detection limits of RT-LAMP assays for both EV71 and CVA16 were 0.1 of a 50% tissue culture infective dose (TCID50) per reaction, based on 10—Fold dilutions of a titrated EV71 or CVA16 strain. The specific assay showed there were no cross-reactions with Coxsackievirus A (CVA) viruses (CVA 2, 4, 5, 7, 9, 10, 14, and 25), Coxsackievirus B (CVB) viruses (CVB 1, 2, 3, 4, and 5) or ECHO viruses (ECHO 3, 6, 11, and 19). In parallel with commercial quantitative real-time polymerase chain reaction (qRT-PCR) diagnostic kits for EV71 and CVA16, the RT-LAMP assay was evaluated with 515 clinical specimens, the results showed the RT-LAMP assay and the qRT-PCR assay were in complete agreement for 513/515 (99.6%) of the specimens. Two samples with discrepant results from two methods were further verified by nested reverse transcription polymerase chain reaction (nRT-PCR) assay and sequencing to be true positives for CVA16. In conclusion, RT-LAMP assay is demonstrated to be a sensitive and specific assay and have a great potential for the rapid and visual screening of EV71 and CVA16 in China, especially in those resource-limited hospitals and rural clinics of provincial and municipal regions.展开更多
Objective:To develop a loop-mediated isothermal amplification(LAMP) assay for the detection of Entamoeba histolytica(E.histolytica),the causative agent of amebiasis.Methods:The LAMP primer set was designed from E.hist...Objective:To develop a loop-mediated isothermal amplification(LAMP) assay for the detection of Entamoeba histolytica(E.histolytica),the causative agent of amebiasis.Methods:The LAMP primer set was designed from E.histolytica hemolysin gene HLY6.Genomic DNA of E.histolytica trophozoites strain HK9 was used to optimize the LAMP mixture and conditions.Amplification of DNA in the LAMP mixture was monitored through visual inspection for turbidity of the LAMP mix as well as addition of fluorescent dye.Results:Positive LAMP reactions turned turbid while negative ones remained clear.Upon addition of a fluorescent dye,all positive reactions turned green while the negative control remained orange under ambient light After elecrophoresis in 1.5% agarose gels,a ladder of multiple bands of different sizes can be oliserved in positive samples while no bands were detected in the negative control.The sensitivity of the assay was found to be S parasites per reaction which corresponds to approximately 1S.8 ng/μL DNA.The specificity of the assay was verified by the absence of amplified products when DNA from other gastrointestinal parasites such as the morphologically similar but non-pathogenic species,Entamoeba dispar. and other diarrhea-causing organisms such as Blastocystis hominis and Escherichia coli were used.Conclusions:The I.AMP assay we have developed enables the detection of E.histolytica with rapidity and ease,therefore rendering it is suitable for laboratory and field diagnosis of amebiasis.展开更多
Loop-mediated isothermal ampliifcation (LAMP) is a novel nucleic acid diagnostic method that can amplify rapidly a target template under isothermal conditions. In this study, a LAMP assay for rapid detection of Chin...Loop-mediated isothermal ampliifcation (LAMP) is a novel nucleic acid diagnostic method that can amplify rapidly a target template under isothermal conditions. In this study, a LAMP assay for rapid detection of Chinese giant salamander ranavirus(CGSRV) was developed from culture isolates and clinical samples. The LAMP assay was developed by designing one set of four speciifc primers, targeting the major capsid protein (MCP) gene of CGSRV. Reaction time and temperature were optimal for 40 min at 62°C. The developed LAMP assay is speciifc and highly sensitive for CGSRV detection, the detection limit could reach about 5 copies of cloned viral genomic fragments. The sensitivity of the LAMP assay was about 1000 and 10-fold higher than that of both conventional and nested PCR, respectively. The LAMP ampliifcation produces a typical ladder-like pattern of products on an agarose gel that can be visually inspected after addition of ethidium bromide. The LAMP assay was evaluated further with clinical samples, and the results indicated the suitability and simplicity of the test as a rapid diagnostic tool for the detection of CGSRV.展开更多
Vibrio anguillarum is an important bacterial pathogen of aquatic organisms and a significant problem in aquatic farming. The rapid detection and identification of V. anguillarum, and other pathogens that infect marine...Vibrio anguillarum is an important bacterial pathogen of aquatic organisms and a significant problem in aquatic farming. The rapid detection and identification of V. anguillarum, and other pathogens that infect marine organisms, is crucial to effective disease management. In this study, we developed a loop-mediated amplification (LAMP) assay to detect V. anguillarum in an hour in a single tube without the need for thermal cycling. Conserved regions of the metalloproteinase (empA) gene of V. anguillarum served as the targets for primer design. A fragment of the empA gene was amplified at 65℃ in the presence of the primer mixture and Bst DNA polymerase. In the optimized LAMP assay, 6.7 pg of V. anguillarum DNA could be detected. Six strains of V. anguillarum and 17 strains of non-V, anguillarum bacteria were used in this study to evaluate the species specificity of the primers. The six V. anguillarum strains gave a positive result in the LAMP assay. This method was also validated in V. anguillarum-infected fish. This LAMP method is more sensitive than PCR in the detection of V. anguillarum and shows good species specificity. The LAMP assay is therefore an effective method for the quick detection of V. anguillarum both in the laboratory and in the field.展开更多
Pectobacterium carotovorum is the causal agent of bacterial soft rot in a wide range of vegetable host species.Once P.carotovorum infects the plant,the spread of the disease is difficult to control.In this study,a rap...Pectobacterium carotovorum is the causal agent of bacterial soft rot in a wide range of vegetable host species.Once P.carotovorum infects the plant,the spread of the disease is difficult to control.In this study,a rapid and sensitive method based on loop-mediated isothermal amplification(LAMP)was developed for detecting P.carotovorum in celery with soft rot using a primer set designed from the pmrA conserved sequence of P.carotovorum.The specificity of the LAMP primer set for P.carotovorum was extensively validated on both P.carotovorum strains and nontarget strains.The sensitivity was 1 pg of P.carotovorum genomic DNA,which demonstrated 10 times more sensitive than the conventional PCR assay.LAMP was also used to detect P.carotovorum in bacterial suspension.The lowest detection concentration was 104 CFU·mL^−1.In addition,a LAMP assay,in conjunction with a crude DNA extraction method,was successfully performed on P.carotovorum-infected samples derived from both artificially and naturally infected plants.In summary,the LAMP assay established in this study constitutes a simple,sensitive,and rapid method for the detection of P.carotovorum,and has potential application in the control of celery soft rot disease through early detection.展开更多
In this study, the loop-mediated isothermal amplification (LAMP) method was used to develop a rapid and simple detection system for porcine circovirus type 2 (PCV2). According to the PCV2 sequences published in GenBan...In this study, the loop-mediated isothermal amplification (LAMP) method was used to develop a rapid and simple detection system for porcine circovirus type 2 (PCV2). According to the PCV2 sequences published in GenBank, multiple LAMP primers were designed targeting conserved sequences of PCV2. Using the DNA extracted from PCV2 isolates HUN-09 and SD-09 as the template, LAMP reactions in a PCV2 LAMP system was performed, the amplification products were detected by adding SYBR Green I and could be observed directly by the naked eye. The results showed highly-efficient and specific amplification in 30 min at 63°C with a LAMP real-time turbidimeter. Furthermore, PCV2 DNA templates, with a detection limit of 5.5×10-5 ng of nucleic acid, indicated that this assay was highly sensitive. The results obtained with the naked eye after SYBR Green I staining were consistent with those detected by the real-time turbidimeter, showing the potential simplicity of interpretation of the assay results. The LAMP assay appeared to have greater accuracy than PCR and virus isolation for the analysis of 18 clinical samples. In addition it offers higher specificity and sensitivity, shorter reaction times and simpler procedures than the currently available methods of PCV2 detection. It is therefore a promising tool for the effective and efficient detection of PCV2.展开更多
Rapid,sensitive,point-of-care detection of pathogenic bacteria is important for food safety.In this study,we developed a novel quantum dot nanobeads-labelled lateral flow immunoassay strip(QBs-labelled LFIAS)combined ...Rapid,sensitive,point-of-care detection of pathogenic bacteria is important for food safety.In this study,we developed a novel quantum dot nanobeads-labelled lateral flow immunoassay strip(QBs-labelled LFIAS)combined with strand displacement loop-mediated isothermal amplification(SD-LAMP)for quantitative Salmonella Typhimurium(ST)detection.Quantum dot nanobeads(QBs)served as fluorescence reporters,providing good detection efficiency.The customizable strand displacement(SD)probe was used in LAMP to improve the specificity of the method and prevent by-product capture.Detection was based on a sandwich immunoassay.A fluorescence strip reader measured the fluorescence intensity(FI)of the test(T)line and control(C)line.The linear detection range of the strip was 10^(2)–10^(8) colony forming units(CFU)·mL^(-1).The visual limit of detection was 10^(3) CFU·mL^(-1),indicating that the system was ten-fold more sensitive than AuNPs-labelled test strips.ST specificity was analyzed in accordance with agarose gel outputs of polymerase chain reaction(PCR)and SD-LAMP.We detected ST in foods with an acceptable recovery of 85%–110%.The method is rapid,simple,almost equipment-free,and suitable for bacterial detection in foods and for clinical diagnosis.展开更多
Maize chlorotic mottle virus (MCMV) is a quarantine pest as approved by Chinese government: A rapid, sensitive and specific MCMV detection method using reverse transcription-loop-mediated isothermal amplification ...Maize chlorotic mottle virus (MCMV) is a quarantine pest as approved by Chinese government: A rapid, sensitive and specific MCMV detection method using reverse transcription-loop-mediated isothermal amplification (RT-LAMP) was established in this study. Based on the sequence of MCMV coat protein coding gene, 3 sets of primers were designed and specificity test showed that the second set of primers was specific to MCMV, Similar sensitivities were observed on RT-LAMP and RT-PCR, except that RT-LAMP was quicker, and the reaction could be finished within 1 h. In addition, the presence or absence of the fluorescence under daylight allows naked easy detection of the amplification of MCMV genomic RNA using calcein. The RT-LAMP assay was applied successfully to detect MCMV in maize seeds, and the result by the addition of calcein was consistent with the result detected by the real time turbidimeter. The method is rapid, specific, sensitive without the need for complicated equipment, and is suitable for rapid field detection of MCMV.展开更多
[Objective] This study aimed to detect the reliability of LAMP method for detecting Listeria monocytogenes in dairy food. [Method] Based on the sequence of hlyA gene encoding listeriolysin O in Listeria monocytogenes,...[Objective] This study aimed to detect the reliability of LAMP method for detecting Listeria monocytogenes in dairy food. [Method] Based on the sequence of hlyA gene encoding listeriolysin O in Listeria monocytogenes, the LAMP method was established for detecting Listeria monocytogenes in dairy food. [Result] The es- tablished LAMP rapid detection method has .high specificity and sensitivity, which are equivalent to those of real-time fluorescent quantitative PCR. The detection re- sults of Listeria monocytogenes in dairy food by established LAMP method were completely consistent with those by bacterial isolation method. [Conclusion] The de- tection results of Listeria monocytogenes by LAMP method can be directly identified by naked eye, so the established LAMP method was suitable for the detection of Listeria monocytogenes in dairy food in emergency situations.展开更多
[ Objective ] This study was to investigate the creditability of applying loop-mediated isothermal amplification method (LAMP) to detect Staphylococcus aureus in dairy products. [ Methods] The primers for heat resis...[ Objective ] This study was to investigate the creditability of applying loop-mediated isothermal amplification method (LAMP) to detect Staphylococcus aureus in dairy products. [ Methods] The primers for heat resistant nuclease gene (nuc) of Staphylococcus aureus were designed for establishing the LAMP method for rapidly detecting Staphylococcus aureus. [ Results ] The results of LAMP detection on Staphylococcus aureus in various dairy products were completely identical with that by bacterial isolation test; meanwhile it has a high specificity and a 10-fold sensitivity over the hemi-nested PCR. [ Conclusion] LAMP can be used for the detection of Staphylococcus aureus in dairy products.展开更多
Vibrio vulnificus is an estuarine bacterial pathogen for human.The rapid,specific and sensitive detection of V.vulnificus is urgently needed for early disease diagnosis and timely treatment of V.vulnificus infection.I...Vibrio vulnificus is an estuarine bacterial pathogen for human.The rapid,specific and sensitive detection of V.vulnificus is urgently needed for early disease diagnosis and timely treatment of V.vulnificus infection.In the study,a loop-mediated isothermal amplification(LAMP) technique was developed for V.vulnificus detection with a set of primers,composed of two out primers and two inner primers targeted to vvh A gene.The optimal amplification temperature was 63°C and the reaction only took 35 min.The amplification products could not only be detected by agarose gel electrophoresis with ladder-like pattern bands,but also could be visualized using calcein with naked eye directly.Forty-five strains were tested for the specificity of LAMP assay,and all the V.vulnificus strains were identified correctly while other strains were negative results.The sensitive of the new LAMP assay was 100-fold more sensitive than the conventional PCR.Meanwhile,all the V.vulnificus strains were detected correctly in spiked,clinical and environmental samples by the new LAMP assay.Compared with other well-known techniques,the new LAMP assay targeted to vvh A gene was extremely rapid,simple,sensitive and specific for V.vulnificus identification.展开更多
A loop-mediated isothermal amplification (LAMP) assay was designed and evaluated for rapid de- tection of the toxic microalgae Alexandrium catenella and A. minutum, which can produce paralytic shellfish poisoning (...A loop-mediated isothermal amplification (LAMP) assay was designed and evaluated for rapid de- tection of the toxic microalgae Alexandrium catenella and A. minutum, which can produce paralytic shellfish poisoning (PSP). Two sets of four specific primers targeting these two species were derived from the sequence of internal transcribed spacer (ITS) of ribosomal DNA. The method worked well in less than an hour under isothermal conditions of 65℃. LAMP specificity was validated in closely related algae as a comparison, suggesting the strict specificity of the LAMP primers. Two visual inspection approaches were feasible to interpret the positive or negative results. The detection lim- its of A. catenella and A. minutum samples using the LAMP assay were found to be 5.6 and 4.5 pg DNA, respectively. The sensitivity of this LAMP assay was 10 or 100-fold higher than Polymerase Chain Reaction (PCR) method in detecting the two microalgae. These characteristics of species specificity, sensitivity, and rapidity suggest that this method has the potentiality in the monitoring of red tide caused by A. catenella and A. minutum.展开更多
In situ loop-mediated isothermal amplification (in situ LAMP) combines in situ hybridization and loop-mediated isothermal amplification (LAMP) techniques for chromosomal localization of DNA sequences. In situ LAMP...In situ loop-mediated isothermal amplification (in situ LAMP) combines in situ hybridization and loop-mediated isothermal amplification (LAMP) techniques for chromosomal localization of DNA sequences. In situ LAMP is a method that is generally more specific and sensitive than conventional techniques such as fluorescence in situ hybridization (FISH), primed in situ labeling (PRINS), and cycling primed in situ labeling (C-PRINS). Here, we describe the development and application of in situ LAMP to identify the chromosomal localization of DNA sequences. To benchmark this technique, we successfully applied this technique to localize the major ribosomal RNA gene on the chromosomes of the Zhikong scallop ( Chlarnys farreri).展开更多
Plague caused by Yersinia pestis is one of the infectious diseases subject to the International Health Regulations (IHR). Permanent monitoring of the focal plague areas is mandatory in order to enable prompt control m...Plague caused by Yersinia pestis is one of the infectious diseases subject to the International Health Regulations (IHR). Permanent monitoring of the focal plague areas is mandatory in order to enable prompt control measures to prevent the spread of the disease. Therefore, the availability of efficient diagnosis tests is of paramount importance. Here, we describe a loop-mediated isothermal amplification (LAMP)-based procedure for rapid Y. pestis detection. We constructed a set of LAMP primers, which were used in assays to establish the reaction conditions that would lead to the quick visualization of the results by evaluating the test tube with the naked eye. The primers were specifically designed to target the caf1 gene located on pFra/Tox (pMT), a prototypical plasmid of Y. pestis. The LAMP procedure was performed at 65°C for 45 min in a water bath and allowed for the detection of at least 10 pg of bacterial DNA. Due to its simplicity, specificity, sensitivity and rapidity, the LAMP technique is an additional tool that may be implemented in routine plague diagnoses, especially in emergencies.展开更多
A set of universal loop-mediated isothermal amplification (LAMP) primers targeting the flo gene was designed to detect Borrelia burgdorferi sensu lato (B. burgdorferi s.I.) in human samples. The sensitivity of LAM...A set of universal loop-mediated isothermal amplification (LAMP) primers targeting the flo gene was designed to detect Borrelia burgdorferi sensu lato (B. burgdorferi s.I.) in human samples. The sensitivity of LAMP was 20 copies/reaction, and the assay did not detect false positives among 11 other related bacteria. A positive LAMP result was obtained for 9 of the 24 confirmed cases and for 12 of 94 suspected cases. The positive rate of LAMP was the same as that of nested PCR. The LAMP is a useful diagnostic method that can be developed for rapid detection of B. burgdorferi s.I. in human sera. Combination of the LAMP and nested PCR was more sensitive for detecting B. burgdorferi s.I. in human serum samples.展开更多
Viral hemorrhagic septicemia virus(VHSV) and marine birnavirus(MABV) are the causative pathogens for some of the most explosive epidemics of emerging viral diseases in many Asian countries, leading to huge economi...Viral hemorrhagic septicemia virus(VHSV) and marine birnavirus(MABV) are the causative pathogens for some of the most explosive epidemics of emerging viral diseases in many Asian countries, leading to huge economic losses in aquaculture. Rapid molecular detection for surveillance or diagnosis has been a critical component in reducing the prevalence of pathogen infection. The loop-mediated isothermal amplification(LAMP) of DNA is currently one of the most commonly used molecular diagnostic tools, as it is simple, quick, and easy to amplify target DNA under isothermal conditions. In the present study, a novel and highly specific LAMP assay for the sensitive and rapid detection of VHSV and MABV infection in fish was developed. Using a set of synthesized primers matching a specific region of the genome, the efficiency and specificity of the LAMP assay were optimized in terms of the reaction temperature and DNA polymerase concentration, as they are the main determinants of the sensitivity and specificity of the LAMP assay. In particular, we demonstrated that our assay could be applied to efficient detection of VHSV and MABV infection in the wild fish, Paralichthys olivaceus. Our results demonstrate the simplicity and convenience of this method for the detection of viral infection in aquatic organisms.展开更多
基金Supported by the Natural Science Foundation of Heilongjiang Province(Topic C2017032)Heilongjiang Province Applied Technology Research and Development Program(Topic GA19B104)the National Key Research and Development Program(Topic 2018YFD0300105)。
文摘Rice bacterial leaf brown spot disease caused by Pseudomonas syringae pv.syringae(Pss)is a major disease on rice.In recent years,Pss has emerged worldwide,seriously affecting rice production.It is very important to establish a rapid detection method of Pss for the diagnosis and prevention of this disease.In order to robust and accurately diagnose the rice bacterial leaf brown spot disease in the field and laboratory,an assay system for the Pss was developed in this study,and the specific sequence of hrcN was used as the target,based on loop-mediated isothermal amplification(LAMP).The best detection system was MgSO 48 mmol·L^(-1),Bst DNA polymerase 8 U,dNTP 1.4 mmol·L^(-1),the ratio of internal and outer primers was 2:1,the reaction temperature was 63℃,the reaction time was 45 min,and the lowest sensitivity was 104 CFU·mL^(-1).This results provided an accurate and robust method for laboratory and field diagnosis of bacterial leaf brown spot disease of rice.
基金General Administrationof Quality Supervision, Inspection and Quarantine of China(HK001-2007).
文摘Loop-mediated isothermal amplification (LAMP) is a novel nucleic acid amplification method, which amplifies DNA with high specificity, sensitivity, rapidity and efficiency under isothermal conditions using a set of four specially designed primers and a Bst DNA polymerase with strand displacement activity. The basic principle, characteristics, development of LAMP and its applications are summarized in this article.
基金supported by funding from the National Institutes of Health (NIH) Exploratory/Developmental Grant (R21) (AI106024)supported by a Ruth L.Kirschstein National Research Service Award for Individual Pred octoral MD/PhD and Other Dual Doctoral Degree Fellows (F30) (AI109825)
文摘Viral load measurements are an essential tool for the long-term clinical care of human immunodeficiency virus (HIV)-positive individuals. The gold standards in viral load instrumentation, however, are still too limited by their size, cost, and sophisticated operation for these measurements to be ubiquitous in remote settings with poor healthcare infrastructure, including parts of the world that are disproportionately affected by HIV infection. The challenge of developing a point-of-care platform capable of making viral load more accessible has been frequently approached but no solution has yet emerged that meets the practical requirements of low cost, portability, and ease-of-use. In this paper, we perform reverse-transcription loop-mediated isothermal amplification (RT-LAMP) on minimally processed HIV-spiked whole blood samples with a microfluidic and silicon microchip platform, and perform fluorescence measurements with a consumer smartphone. Our integrated assay shows amplification from as few as three viruses in a - 60 nL RT- LAMP droplet, corresponding to a whole blood concentration of 670 viruses per μL of whole blood. The technology contains greater power in a digital RT-LAMP approach that could be scaled up for the determination of viral load from a finger prick of blood in the clinical care of HIV-positive individuals. We demonstrate that all aspects of this viral load approach, from a drop of blood to imaging the RT-LAMP reaction, are compatible with lab-on-a-chip components and mobile instrumentation.
文摘A real-time monitoring reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay was developed for the sensitive and specific detection of prototypic,prevalent North American porcine reproductive and respiratory syndrome virus (PRRSV) strains.As a higher sensitivity and specificity method than reverse transcription polymerase chain reaction (RT-PCR),the RT-LAMP method only used a turbidimeter,exhibited a detection limit corresponding to a 10-4 dilution of template RNA extracted from 250 μL of 105 of the 50% tissue culture infective dose (TCID50) of PRRSV-containing cells,and no cross-reactivity was observed with other related viruses including porcine circovirus type 2,swine influenza virus,porcine rotavirus and classical swine fever virus.From forty-two field samples,33 samples in the RT-LAMP assay was detected positive,whereas three of which were not detected by RT-PCR.Furthermore,in 33 strains of PRRSV,an identical detection rate was observed with the RT-LAMP assay to what were isolated using porcine alveolar macrophages.These findings demonstrated that the RT-LAMP assay has potential clinical applications for the detection of highly pathogenic PRRSV isolates,especially in developing countries.
文摘A sensitive reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for human enterovirus 71 (EV71) and Coxsackievirus A16 (CVA16) infection was further evaluated. The one step reaction was performed in a single tube at 65?C for 45 min for EV71 and 35 min for CVA16. The detection limits of RT-LAMP assays for both EV71 and CVA16 were 0.1 of a 50% tissue culture infective dose (TCID50) per reaction, based on 10—Fold dilutions of a titrated EV71 or CVA16 strain. The specific assay showed there were no cross-reactions with Coxsackievirus A (CVA) viruses (CVA 2, 4, 5, 7, 9, 10, 14, and 25), Coxsackievirus B (CVB) viruses (CVB 1, 2, 3, 4, and 5) or ECHO viruses (ECHO 3, 6, 11, and 19). In parallel with commercial quantitative real-time polymerase chain reaction (qRT-PCR) diagnostic kits for EV71 and CVA16, the RT-LAMP assay was evaluated with 515 clinical specimens, the results showed the RT-LAMP assay and the qRT-PCR assay were in complete agreement for 513/515 (99.6%) of the specimens. Two samples with discrepant results from two methods were further verified by nested reverse transcription polymerase chain reaction (nRT-PCR) assay and sequencing to be true positives for CVA16. In conclusion, RT-LAMP assay is demonstrated to be a sensitive and specific assay and have a great potential for the rapid and visual screening of EV71 and CVA16 in China, especially in those resource-limited hospitals and rural clinics of provincial and municipal regions.
基金supported financially by a research grant from the Natural Sciences Research Institute,University of the Philippines ) BIO 1 l-l-05) to W.L.R.
文摘Objective:To develop a loop-mediated isothermal amplification(LAMP) assay for the detection of Entamoeba histolytica(E.histolytica),the causative agent of amebiasis.Methods:The LAMP primer set was designed from E.histolytica hemolysin gene HLY6.Genomic DNA of E.histolytica trophozoites strain HK9 was used to optimize the LAMP mixture and conditions.Amplification of DNA in the LAMP mixture was monitored through visual inspection for turbidity of the LAMP mix as well as addition of fluorescent dye.Results:Positive LAMP reactions turned turbid while negative ones remained clear.Upon addition of a fluorescent dye,all positive reactions turned green while the negative control remained orange under ambient light After elecrophoresis in 1.5% agarose gels,a ladder of multiple bands of different sizes can be oliserved in positive samples while no bands were detected in the negative control.The sensitivity of the assay was found to be S parasites per reaction which corresponds to approximately 1S.8 ng/μL DNA.The specificity of the assay was verified by the absence of amplified products when DNA from other gastrointestinal parasites such as the morphologically similar but non-pathogenic species,Entamoeba dispar. and other diarrhea-causing organisms such as Blastocystis hominis and Escherichia coli were used.Conclusions:The I.AMP assay we have developed enables the detection of E.histolytica with rapidity and ease,therefore rendering it is suitable for laboratory and field diagnosis of amebiasis.
基金supported by the Sichuan Technology Support Planning (No. 2014 NZ0027)
文摘Loop-mediated isothermal ampliifcation (LAMP) is a novel nucleic acid diagnostic method that can amplify rapidly a target template under isothermal conditions. In this study, a LAMP assay for rapid detection of Chinese giant salamander ranavirus(CGSRV) was developed from culture isolates and clinical samples. The LAMP assay was developed by designing one set of four speciifc primers, targeting the major capsid protein (MCP) gene of CGSRV. Reaction time and temperature were optimal for 40 min at 62°C. The developed LAMP assay is speciifc and highly sensitive for CGSRV detection, the detection limit could reach about 5 copies of cloned viral genomic fragments. The sensitivity of the LAMP assay was about 1000 and 10-fold higher than that of both conventional and nested PCR, respectively. The LAMP ampliifcation produces a typical ladder-like pattern of products on an agarose gel that can be visually inspected after addition of ethidium bromide. The LAMP assay was evaluated further with clinical samples, and the results indicated the suitability and simplicity of the test as a rapid diagnostic tool for the detection of CGSRV.
基金Supported by the National Basic Research Program of China (973 Program) (No. 2006CB101804)the General Administration of Quality Supervision,Inspection and Quarantine of the People's Republic of China (No. 2007IK167)National Department Public Benefit Research Foundation (No. 200803012)
文摘Vibrio anguillarum is an important bacterial pathogen of aquatic organisms and a significant problem in aquatic farming. The rapid detection and identification of V. anguillarum, and other pathogens that infect marine organisms, is crucial to effective disease management. In this study, we developed a loop-mediated amplification (LAMP) assay to detect V. anguillarum in an hour in a single tube without the need for thermal cycling. Conserved regions of the metalloproteinase (empA) gene of V. anguillarum served as the targets for primer design. A fragment of the empA gene was amplified at 65℃ in the presence of the primer mixture and Bst DNA polymerase. In the optimized LAMP assay, 6.7 pg of V. anguillarum DNA could be detected. Six strains of V. anguillarum and 17 strains of non-V, anguillarum bacteria were used in this study to evaluate the species specificity of the primers. The six V. anguillarum strains gave a positive result in the LAMP assay. This method was also validated in V. anguillarum-infected fish. This LAMP method is more sensitive than PCR in the detection of V. anguillarum and shows good species specificity. The LAMP assay is therefore an effective method for the quick detection of V. anguillarum both in the laboratory and in the field.
基金the earmarked fund for Beijing Innovation Consortium of Agriculture Research System(Grant No.BAIC-2019)Key Laboratory of Biology and Genetic Improvement of Horticultural Crops,Ministry of Agriculture,P.R.China,and Science and Technology Innovation Program of the Chinese Academy of Agricultural Sciences(Grant No.CAAS-ASTIPIVFCAAS).
文摘Pectobacterium carotovorum is the causal agent of bacterial soft rot in a wide range of vegetable host species.Once P.carotovorum infects the plant,the spread of the disease is difficult to control.In this study,a rapid and sensitive method based on loop-mediated isothermal amplification(LAMP)was developed for detecting P.carotovorum in celery with soft rot using a primer set designed from the pmrA conserved sequence of P.carotovorum.The specificity of the LAMP primer set for P.carotovorum was extensively validated on both P.carotovorum strains and nontarget strains.The sensitivity was 1 pg of P.carotovorum genomic DNA,which demonstrated 10 times more sensitive than the conventional PCR assay.LAMP was also used to detect P.carotovorum in bacterial suspension.The lowest detection concentration was 104 CFU·mL^−1.In addition,a LAMP assay,in conjunction with a crude DNA extraction method,was successfully performed on P.carotovorum-infected samples derived from both artificially and naturally infected plants.In summary,the LAMP assay established in this study constitutes a simple,sensitive,and rapid method for the detection of P.carotovorum,and has potential application in the control of celery soft rot disease through early detection.
基金Fifteenth National Science and Technology Support Program of China(2007BAD86B04-4)
文摘In this study, the loop-mediated isothermal amplification (LAMP) method was used to develop a rapid and simple detection system for porcine circovirus type 2 (PCV2). According to the PCV2 sequences published in GenBank, multiple LAMP primers were designed targeting conserved sequences of PCV2. Using the DNA extracted from PCV2 isolates HUN-09 and SD-09 as the template, LAMP reactions in a PCV2 LAMP system was performed, the amplification products were detected by adding SYBR Green I and could be observed directly by the naked eye. The results showed highly-efficient and specific amplification in 30 min at 63°C with a LAMP real-time turbidimeter. Furthermore, PCV2 DNA templates, with a detection limit of 5.5×10-5 ng of nucleic acid, indicated that this assay was highly sensitive. The results obtained with the naked eye after SYBR Green I staining were consistent with those detected by the real-time turbidimeter, showing the potential simplicity of interpretation of the assay results. The LAMP assay appeared to have greater accuracy than PCR and virus isolation for the analysis of 18 clinical samples. In addition it offers higher specificity and sensitivity, shorter reaction times and simpler procedures than the currently available methods of PCV2 detection. It is therefore a promising tool for the effective and efficient detection of PCV2.
基金This work was supported by the National Key Research and Development Program of China(2019YFC1606300)the Local Innovative and Research Teams Project of Guangdong Pearl River Talents Program(2017BT01S174)the Guangdong Academy of Sciences Special Project of Implementing Innovation-Driven Development Capacity Building(2018GDASCX-0401).
文摘Rapid,sensitive,point-of-care detection of pathogenic bacteria is important for food safety.In this study,we developed a novel quantum dot nanobeads-labelled lateral flow immunoassay strip(QBs-labelled LFIAS)combined with strand displacement loop-mediated isothermal amplification(SD-LAMP)for quantitative Salmonella Typhimurium(ST)detection.Quantum dot nanobeads(QBs)served as fluorescence reporters,providing good detection efficiency.The customizable strand displacement(SD)probe was used in LAMP to improve the specificity of the method and prevent by-product capture.Detection was based on a sandwich immunoassay.A fluorescence strip reader measured the fluorescence intensity(FI)of the test(T)line and control(C)line.The linear detection range of the strip was 10^(2)–10^(8) colony forming units(CFU)·mL^(-1).The visual limit of detection was 10^(3) CFU·mL^(-1),indicating that the system was ten-fold more sensitive than AuNPs-labelled test strips.ST specificity was analyzed in accordance with agarose gel outputs of polymerase chain reaction(PCR)and SD-LAMP.We detected ST in foods with an acceptable recovery of 85%–110%.The method is rapid,simple,almost equipment-free,and suitable for bacterial detection in foods and for clinical diagnosis.
文摘Maize chlorotic mottle virus (MCMV) is a quarantine pest as approved by Chinese government: A rapid, sensitive and specific MCMV detection method using reverse transcription-loop-mediated isothermal amplification (RT-LAMP) was established in this study. Based on the sequence of MCMV coat protein coding gene, 3 sets of primers were designed and specificity test showed that the second set of primers was specific to MCMV, Similar sensitivities were observed on RT-LAMP and RT-PCR, except that RT-LAMP was quicker, and the reaction could be finished within 1 h. In addition, the presence or absence of the fluorescence under daylight allows naked easy detection of the amplification of MCMV genomic RNA using calcein. The RT-LAMP assay was applied successfully to detect MCMV in maize seeds, and the result by the addition of calcein was consistent with the result detected by the real time turbidimeter. The method is rapid, specific, sensitive without the need for complicated equipment, and is suitable for rapid field detection of MCMV.
基金Supported by Natural Science Foundation of Anhui Province(1508085QC64)~~
文摘[Objective] This study aimed to detect the reliability of LAMP method for detecting Listeria monocytogenes in dairy food. [Method] Based on the sequence of hlyA gene encoding listeriolysin O in Listeria monocytogenes, the LAMP method was established for detecting Listeria monocytogenes in dairy food. [Result] The es- tablished LAMP rapid detection method has .high specificity and sensitivity, which are equivalent to those of real-time fluorescent quantitative PCR. The detection re- sults of Listeria monocytogenes in dairy food by established LAMP method were completely consistent with those by bacterial isolation method. [Conclusion] The de- tection results of Listeria monocytogenes by LAMP method can be directly identified by naked eye, so the established LAMP method was suitable for the detection of Listeria monocytogenes in dairy food in emergency situations.
文摘[ Objective ] This study was to investigate the creditability of applying loop-mediated isothermal amplification method (LAMP) to detect Staphylococcus aureus in dairy products. [ Methods] The primers for heat resistant nuclease gene (nuc) of Staphylococcus aureus were designed for establishing the LAMP method for rapidly detecting Staphylococcus aureus. [ Results ] The results of LAMP detection on Staphylococcus aureus in various dairy products were completely identical with that by bacterial isolation test; meanwhile it has a high specificity and a 10-fold sensitivity over the hemi-nested PCR. [ Conclusion] LAMP can be used for the detection of Staphylococcus aureus in dairy products.
基金The Major PLA Research Project of "The 12th Five-Year Plan" for Medical Science Development under contract No.BWS12J014the Primary Research & Development Plan of Shandong Province under contract No.2016GSF121036
文摘Vibrio vulnificus is an estuarine bacterial pathogen for human.The rapid,specific and sensitive detection of V.vulnificus is urgently needed for early disease diagnosis and timely treatment of V.vulnificus infection.In the study,a loop-mediated isothermal amplification(LAMP) technique was developed for V.vulnificus detection with a set of primers,composed of two out primers and two inner primers targeted to vvh A gene.The optimal amplification temperature was 63°C and the reaction only took 35 min.The amplification products could not only be detected by agarose gel electrophoresis with ladder-like pattern bands,but also could be visualized using calcein with naked eye directly.Forty-five strains were tested for the specificity of LAMP assay,and all the V.vulnificus strains were identified correctly while other strains were negative results.The sensitive of the new LAMP assay was 100-fold more sensitive than the conventional PCR.Meanwhile,all the V.vulnificus strains were detected correctly in spiked,clinical and environmental samples by the new LAMP assay.Compared with other well-known techniques,the new LAMP assay targeted to vvh A gene was extremely rapid,simple,sensitive and specific for V.vulnificus identification.
基金The Science and Technology Commission of Shanghai Municipality under contract Nos 06235810108DZ1980802 and 10JC1418600a special research fund for the national non-profit institutes (East China Sea Fisheries Research Institute) under contract Nos 2007M22 and 2007Z01
文摘A loop-mediated isothermal amplification (LAMP) assay was designed and evaluated for rapid de- tection of the toxic microalgae Alexandrium catenella and A. minutum, which can produce paralytic shellfish poisoning (PSP). Two sets of four specific primers targeting these two species were derived from the sequence of internal transcribed spacer (ITS) of ribosomal DNA. The method worked well in less than an hour under isothermal conditions of 65℃. LAMP specificity was validated in closely related algae as a comparison, suggesting the strict specificity of the LAMP primers. Two visual inspection approaches were feasible to interpret the positive or negative results. The detection lim- its of A. catenella and A. minutum samples using the LAMP assay were found to be 5.6 and 4.5 pg DNA, respectively. The sensitivity of this LAMP assay was 10 or 100-fold higher than Polymerase Chain Reaction (PCR) method in detecting the two microalgae. These characteristics of species specificity, sensitivity, and rapidity suggest that this method has the potentiality in the monitoring of red tide caused by A. catenella and A. minutum.
基金Supported by the National Natural Science Foundation of China (Nos.31270047, 30901096)the National Key Technology R&D Program of China(Nos. 2011BAD45B01, 2011BAD13B05)the Earmarked Fund For Modern Agro-Industry Technology Research System to Dr. Zhenmin BAO
文摘In situ loop-mediated isothermal amplification (in situ LAMP) combines in situ hybridization and loop-mediated isothermal amplification (LAMP) techniques for chromosomal localization of DNA sequences. In situ LAMP is a method that is generally more specific and sensitive than conventional techniques such as fluorescence in situ hybridization (FISH), primed in situ labeling (PRINS), and cycling primed in situ labeling (C-PRINS). Here, we describe the development and application of in situ LAMP to identify the chromosomal localization of DNA sequences. To benchmark this technique, we successfully applied this technique to localize the major ribosomal RNA gene on the chromosomes of the Zhikong scallop ( Chlarnys farreri).
文摘Plague caused by Yersinia pestis is one of the infectious diseases subject to the International Health Regulations (IHR). Permanent monitoring of the focal plague areas is mandatory in order to enable prompt control measures to prevent the spread of the disease. Therefore, the availability of efficient diagnosis tests is of paramount importance. Here, we describe a loop-mediated isothermal amplification (LAMP)-based procedure for rapid Y. pestis detection. We constructed a set of LAMP primers, which were used in assays to establish the reaction conditions that would lead to the quick visualization of the results by evaluating the test tube with the naked eye. The primers were specifically designed to target the caf1 gene located on pFra/Tox (pMT), a prototypical plasmid of Y. pestis. The LAMP procedure was performed at 65°C for 45 min in a water bath and allowed for the detection of at least 10 pg of bacterial DNA. Due to its simplicity, specificity, sensitivity and rapidity, the LAMP technique is an additional tool that may be implemented in routine plague diagnoses, especially in emergencies.
基金funded by the National Key Science and Technology Projects of China(2012ZX10004219 and 2013ZX10004001)
文摘A set of universal loop-mediated isothermal amplification (LAMP) primers targeting the flo gene was designed to detect Borrelia burgdorferi sensu lato (B. burgdorferi s.I.) in human samples. The sensitivity of LAMP was 20 copies/reaction, and the assay did not detect false positives among 11 other related bacteria. A positive LAMP result was obtained for 9 of the 24 confirmed cases and for 12 of 94 suspected cases. The positive rate of LAMP was the same as that of nested PCR. The LAMP is a useful diagnostic method that can be developed for rapid detection of B. burgdorferi s.I. in human sera. Combination of the LAMP and nested PCR was more sensitive for detecting B. burgdorferi s.I. in human serum samples.
基金The grants from the Korea Institute of Ocean Science and Technology under contract No.PE99315
文摘Viral hemorrhagic septicemia virus(VHSV) and marine birnavirus(MABV) are the causative pathogens for some of the most explosive epidemics of emerging viral diseases in many Asian countries, leading to huge economic losses in aquaculture. Rapid molecular detection for surveillance or diagnosis has been a critical component in reducing the prevalence of pathogen infection. The loop-mediated isothermal amplification(LAMP) of DNA is currently one of the most commonly used molecular diagnostic tools, as it is simple, quick, and easy to amplify target DNA under isothermal conditions. In the present study, a novel and highly specific LAMP assay for the sensitive and rapid detection of VHSV and MABV infection in fish was developed. Using a set of synthesized primers matching a specific region of the genome, the efficiency and specificity of the LAMP assay were optimized in terms of the reaction temperature and DNA polymerase concentration, as they are the main determinants of the sensitivity and specificity of the LAMP assay. In particular, we demonstrated that our assay could be applied to efficient detection of VHSV and MABV infection in the wild fish, Paralichthys olivaceus. Our results demonstrate the simplicity and convenience of this method for the detection of viral infection in aquatic organisms.