A novel frame shift and integral technique for the enhancement of low light level moving image sequence is introduced. According to the technique, motion parameters of target are measured by algorithm based on differe...A novel frame shift and integral technique for the enhancement of low light level moving image sequence is introduced. According to the technique, motion parameters of target are measured by algorithm based on difference processing. To obtain spatial relativity, images are shifted according to the motion parameters. As a result, the processing of integral and average can be applied to images that have been shifted. The technique of frame shift and integral that includes the algorithm of motion parameter determination is discussed, experiments with low light level moving image sequences are also described. The experiment results show the effectiveness and the robustness of the parameter determination algorithm, and the improvement in the signal-to-noise ratio (SNR) of low light level moving images.展开更多
A mathematical model of quantum noise having much effect on the low light imaging system is set up. To simulate the quantum noise, the random numbers obeying noise distribution must be formed and are weighted on the...A mathematical model of quantum noise having much effect on the low light imaging system is set up. To simulate the quantum noise, the random numbers obeying noise distribution must be formed and are weighted on the basis of the model created. Three uniform random sequences are built by the linear congruential method, of which two are used to form integer number and decimal fraction parts of the new random sequence respectively and the third to shuffle the new sequence. And then a Gauss sequence is formed out of uniform distribution by a function transforming method. It actualizes the simulation in real time of quantum noise in the low light imaging system, where video flow is extracted in real time, the noise summed up and played back side by side with the original video signs by a simulation software.展开更多
Existing methods of measurement MTF for discrete imaging system are analysed. A slit target is frequently used to measure the MTF for an imaging system. Usually there are four methods to measure the MTF for a discrete...Existing methods of measurement MTF for discrete imaging system are analysed. A slit target is frequently used to measure the MTF for an imaging system. Usually there are four methods to measure the MTF for a discrete imaging system by using a slit. These methods have something imperfect respectively. But for the discrete imaging systems of under sampling it is difficult to reproduce this type of target properly since frequencies above Nyquist are folded into those below Nyquist, resulting in aliasing effect. To tackle the aliasing problem, a super resolution technique is introduced into our measurement, which gives MTF values both above and below Nyquist more accurately.展开更多
文摘A novel frame shift and integral technique for the enhancement of low light level moving image sequence is introduced. According to the technique, motion parameters of target are measured by algorithm based on difference processing. To obtain spatial relativity, images are shifted according to the motion parameters. As a result, the processing of integral and average can be applied to images that have been shifted. The technique of frame shift and integral that includes the algorithm of motion parameter determination is discussed, experiments with low light level moving image sequences are also described. The experiment results show the effectiveness and the robustness of the parameter determination algorithm, and the improvement in the signal-to-noise ratio (SNR) of low light level moving images.
文摘A mathematical model of quantum noise having much effect on the low light imaging system is set up. To simulate the quantum noise, the random numbers obeying noise distribution must be formed and are weighted on the basis of the model created. Three uniform random sequences are built by the linear congruential method, of which two are used to form integer number and decimal fraction parts of the new random sequence respectively and the third to shuffle the new sequence. And then a Gauss sequence is formed out of uniform distribution by a function transforming method. It actualizes the simulation in real time of quantum noise in the low light imaging system, where video flow is extracted in real time, the noise summed up and played back side by side with the original video signs by a simulation software.
文摘Existing methods of measurement MTF for discrete imaging system are analysed. A slit target is frequently used to measure the MTF for an imaging system. Usually there are four methods to measure the MTF for a discrete imaging system by using a slit. These methods have something imperfect respectively. But for the discrete imaging systems of under sampling it is difficult to reproduce this type of target properly since frequencies above Nyquist are folded into those below Nyquist, resulting in aliasing effect. To tackle the aliasing problem, a super resolution technique is introduced into our measurement, which gives MTF values both above and below Nyquist more accurately.