Low-noise high-stability current sources have essential applications such as neutron electric dipole moment measurement and high-stability magnetometers. Previous studies mainly focused on frequency noise above 0.1 Hz...Low-noise high-stability current sources have essential applications such as neutron electric dipole moment measurement and high-stability magnetometers. Previous studies mainly focused on frequency noise above 0.1 Hz while less on the low-frequency noise/drift. We use double resonance alignment magnetometers(DRAMs) to measure and suppress the low-frequency noise of a homemade current source(CS) board. The CS board noise level is suppressed by about 10 times in the range of 0.001-0.1 Hz and is reduced to 100 n A/√Hz at 0.001 Hz. The relative stability of CS board can reach2.2 × 10^(-8). In addition, the DRAM shows a better resolution and accuracy than a commercial 7.5-digit multimeter when measuring our homemade CS board. Further, by combining the DRAM with a double resonance orientation magnetometer,we may realize a low-noise CS in the 0.001-1000 Hz range.展开更多
The modular multilevel converter(MMC)has become a promising topology for widespread power converter applications.However,an evident circulating current flowing between the phases will increase system losses and compli...The modular multilevel converter(MMC)has become a promising topology for widespread power converter applications.However,an evident circulating current flowing between the phases will increase system losses and complicate the heatsink design.This paper proposes a novel hybrid model predictive control method for MMCs.This method utilizes an indirect structure MPC and a sorting algorithm to implement current tracking and capacitor voltages balancing,considerably resulting in reduced calculation burden.In addition,different from the conventional MPC solutions,we add a simple proportional-integral(PI)controller to suppress circulating current through modifying the submodule(SM)inserted number,which is parallel to the MPC loop.This hybrid control solution combines both advantages of MPC and linear control,evidently resulting in improved performance of circulating current.Finally,the MATLAB/Simulink results of an 11-level MMC system verify the effectiveness of the proposed solution.展开更多
A new Dark Current Suppression (DCS) CMOS readout circuits for large format Quantum-Well-Infrared Photo-detector (QWIP) Focal-Plane-Array (FPA) with novel Correlated-Double-Sampling (CDS) structure based on dynamic so...A new Dark Current Suppression (DCS) CMOS readout circuits for large format Quantum-Well-Infrared Photo-detector (QWIP) Focal-Plane-Array (FPA) with novel Correlated-Double-Sampling (CDS) structure based on dynamic source-follower are proposed, which can overcome the drawbacks of the present techniques, such as sensitive to the non-uniformity of the QWIP materials, poor readout noise features, low frame frequency, limited injection efficiency and dynamic range, etc. The dummy is adopted to realize dark current suppression, while the cascode current mirror (with current ratio of 1:10) can increase charge sensitivity and reduce integration time. Through the novel CDS structure, the output waveform is boxcar, and the frame frequency is increased. Simulation results demonstrate that, in high background sense, the proposed DCS circuit can suppress the dark current, achieve good readout performance, such as low power consumption, high charge sensitivity, high resolution, large dynamic range, and insensitive to the non-uniformity of the QWIP materials.展开更多
Corona discharge suppression for high-voltage direct-current(HVDC)transmission lines at line terminals such as converter stations is a subject that requires attention.In this paper,a method based on a conductor covere...Corona discharge suppression for high-voltage direct-current(HVDC)transmission lines at line terminals such as converter stations is a subject that requires attention.In this paper,a method based on a conductor covered with dielectric film is proposed and implemented through a bench-scale setup.Compared with the bare conductor,the corona discharge suppression effect of the dielectric-film-covered conductor under positive polarity is studied from the composite field strength and ion current density using a line-plate experimental device.The influences of film thickness and film material on the corona discharge suppression effect are investigated.The charge accumulation and dissipation characteristics of different film materials are also studied.The results show that the conductor covered with dielectric film has excellent ability to inhibit corona discharge.The ground-level composite field strength of the conductor covered with dielectric film is lower than its nominal field strength,and its ion current density is at the nA m^(−2) level.The corona threshold voltage can be promoted by increasing the film thickness,but the ability to inhibit corona discharge becomes weak.The larger the surface electric field strength,the more charge accumulated,but the faster the charge dissipation rate.Compared with polyvinyl chloride film,cross-linked polyethylene film has stronger charge accumulation ability and slower charge dissipation rate,which can better restrain the corona discharge of HVDC transmission lines.展开更多
A modified four-dimensional linear active disturbance rejection control(LADRC)strategy is proposed for a dual three-phase permanent magnet synchronous generator(DTP-PMSG)system to reduce cross-coupling between the d a...A modified four-dimensional linear active disturbance rejection control(LADRC)strategy is proposed for a dual three-phase permanent magnet synchronous generator(DTP-PMSG)system to reduce cross-coupling between the d and q axis currents in the d-q subspace and harmonic currents in the x-y subspace.In the d-q subspace,the proposed strategy uses a model-based LADRC to enhance the decoupling effect between the d and q axes and the disturbance rejection ability against parameter variation.In the x-y subspace,the 5th and 7th harmonic current suppression abilities are improved by using quasi-resonant units parallel to the extended state observer of the traditional LADRC.The proposed modified LADRC strategy improved both the steady-state performance and dynamic response of the DTP-PMSG system.The experimental results demonstrate that the proposed strategy is both feasible and effective.展开更多
A design scheme of the intelligent SSB (Solid State Breaker) based on the IGCT (Integrated Gate Commutated Thyris- tor) is presented. The topology of switch module and the structure of the SSB are proposed. Firstly, t...A design scheme of the intelligent SSB (Solid State Breaker) based on the IGCT (Integrated Gate Commutated Thyris- tor) is presented. The topology of switch module and the structure of the SSB are proposed. Firstly, to the IGCT’s over-voltage sensitivity problem, a new technique of reducing the over-voltage is introduced, which releases the elect romantics energy of faulty line by a capacitive current branch to reduce the amplitude of over-voltage. Secondly, the principle of over-voltage suppression with current release branch is analyzed, and the overall control scheme of solid- state breaker is put forward. Finally, the simulation results also demonstrate its obvious effectiveness in over-voltage suppression after adding a current release branch into the SSB.展开更多
Neutral beam injection is one of the effective auxiliary heating methods in magnetic-confinementfusion experiments. In order to acquire the suppressor-grid current signal and avoid the grid being damaged by overheatin...Neutral beam injection is one of the effective auxiliary heating methods in magnetic-confinementfusion experiments. In order to acquire the suppressor-grid current signal and avoid the grid being damaged by overheating, a data acquisition and over-current protection system based on the PXI(PCI e Xtensions for Instrumentation) platform has been developed. The system consists of a current sensor, data acquisition module and over-current protection module. In the data acquisition module,the acquired data of one shot will be transferred in isolation and saved in a data-storage server in a txt file. It can also be recalled using NBWave for future analysis. The over-current protection module contains two modes: remote and local. This gives it the function of setting a threshold voltage remotely and locally, and the forbidden time of over-current protection also can be set by a host PC in remote mode. Experimental results demonstrate that the data acquisition and overcurrent protection system has the advantages of setting forbidden time and isolation transmission.展开更多
电网换相换流器型高压直流输电(line commutated converter-based high voltage direct current,LCC-HVDC)系统若发生后续换相失败,将严重影响交直流混联电网的安全稳定运行。文中首先针对LCC-HVDC系统故障恢复过程中电流偏差控制作用...电网换相换流器型高压直流输电(line commutated converter-based high voltage direct current,LCC-HVDC)系统若发生后续换相失败,将严重影响交直流混联电网的安全稳定运行。文中首先针对LCC-HVDC系统故障恢复过程中电流偏差控制作用阶段易再次发生换相失败的问题,对电流偏差控制参数与换相失败之间的关系进行理论分析,发现此阶段系统若不发生换相失败,逆变侧LCC直流电压和交流换相电压须满足一定的约束关系,且该约束关系受电流偏差控制参数的直接影响。然后,基于理论分析结果,提出一种电流偏差控制参数整定方法,可改善系统故障恢复过程中对直流电压恢复速度和程度的控制要求,使系统更易满足直流电压与交流换相电压稳定运行约束关系,以降低后续换相失败概率。最后,利用PSCAD/EMTDC仿真平台CIGRE标准测试模型验证了理论分析的正确性以及参数整定方法的有效性。展开更多
基于模块化多电平变换器的固态变压器(modular multilevel converter based solid state transformer,MMC-SST)是实现交直流混合配电网柔性互联及能量多向流动的关键装备。针对固态变压器输入级MMC子模块电容纹波电压过大,导致装置的体...基于模块化多电平变换器的固态变压器(modular multilevel converter based solid state transformer,MMC-SST)是实现交直流混合配电网柔性互联及能量多向流动的关键装备。针对固态变压器输入级MMC子模块电容纹波电压过大,导致装置的体积和成本增加的问题,提出一种基于比例重复控制的MMC-SST改进纹波电压抑制策略。首先利用基于比例重复控制的电容电压闭环得到调整后的功率移相角。然后,通过双有源桥变换器将子模块电容纹波功率传递到低压直流母线,从而有效抑制MMC子模块的各频次纹波电压,达到减小电容值的目的。最后,仿真结果表明在网侧电压对称或不对称工况下,基于比例重复控制的MMC-SST子模块电容纹波电压抑制策略均具有良好的纹波电压抑制能力。展开更多
基金Project supported by the National Natural Science Foundation of China (Grant Nos. 12174446 and 61671458)。
文摘Low-noise high-stability current sources have essential applications such as neutron electric dipole moment measurement and high-stability magnetometers. Previous studies mainly focused on frequency noise above 0.1 Hz while less on the low-frequency noise/drift. We use double resonance alignment magnetometers(DRAMs) to measure and suppress the low-frequency noise of a homemade current source(CS) board. The CS board noise level is suppressed by about 10 times in the range of 0.001-0.1 Hz and is reduced to 100 n A/√Hz at 0.001 Hz. The relative stability of CS board can reach2.2 × 10^(-8). In addition, the DRAM shows a better resolution and accuracy than a commercial 7.5-digit multimeter when measuring our homemade CS board. Further, by combining the DRAM with a double resonance orientation magnetometer,we may realize a low-noise CS in the 0.001-1000 Hz range.
基金This work was partially supported by the National Natural Science Foundation of China(11847104)General Program of National Natural Science Foundation of China(51977124)+2 种基金Shandong Natural Science Foundation(ZR2019QEE001)Natural Science Foundation of Jiangsu Province(BK20190204)National Distinguished Expert(Youth Talent)Program of China(31390089963058)。
文摘The modular multilevel converter(MMC)has become a promising topology for widespread power converter applications.However,an evident circulating current flowing between the phases will increase system losses and complicate the heatsink design.This paper proposes a novel hybrid model predictive control method for MMCs.This method utilizes an indirect structure MPC and a sorting algorithm to implement current tracking and capacitor voltages balancing,considerably resulting in reduced calculation burden.In addition,different from the conventional MPC solutions,we add a simple proportional-integral(PI)controller to suppress circulating current through modifying the submodule(SM)inserted number,which is parallel to the MPC loop.This hybrid control solution combines both advantages of MPC and linear control,evidently resulting in improved performance of circulating current.Finally,the MATLAB/Simulink results of an 11-level MMC system verify the effectiveness of the proposed solution.
基金Supported by the National Natural Science Foundation of China(No.60077025)
文摘A new Dark Current Suppression (DCS) CMOS readout circuits for large format Quantum-Well-Infrared Photo-detector (QWIP) Focal-Plane-Array (FPA) with novel Correlated-Double-Sampling (CDS) structure based on dynamic source-follower are proposed, which can overcome the drawbacks of the present techniques, such as sensitive to the non-uniformity of the QWIP materials, poor readout noise features, low frame frequency, limited injection efficiency and dynamic range, etc. The dummy is adopted to realize dark current suppression, while the cascode current mirror (with current ratio of 1:10) can increase charge sensitivity and reduce integration time. Through the novel CDS structure, the output waveform is boxcar, and the frame frequency is increased. Simulation results demonstrate that, in high background sense, the proposed DCS circuit can suppress the dark current, achieve good readout performance, such as low power consumption, high charge sensitivity, high resolution, large dynamic range, and insensitive to the non-uniformity of the QWIP materials.
基金by State Grid Shandong Electric Power Company(52062618001M)。
文摘Corona discharge suppression for high-voltage direct-current(HVDC)transmission lines at line terminals such as converter stations is a subject that requires attention.In this paper,a method based on a conductor covered with dielectric film is proposed and implemented through a bench-scale setup.Compared with the bare conductor,the corona discharge suppression effect of the dielectric-film-covered conductor under positive polarity is studied from the composite field strength and ion current density using a line-plate experimental device.The influences of film thickness and film material on the corona discharge suppression effect are investigated.The charge accumulation and dissipation characteristics of different film materials are also studied.The results show that the conductor covered with dielectric film has excellent ability to inhibit corona discharge.The ground-level composite field strength of the conductor covered with dielectric film is lower than its nominal field strength,and its ion current density is at the nA m^(−2) level.The corona threshold voltage can be promoted by increasing the film thickness,but the ability to inhibit corona discharge becomes weak.The larger the surface electric field strength,the more charge accumulated,but the faster the charge dissipation rate.Compared with polyvinyl chloride film,cross-linked polyethylene film has stronger charge accumulation ability and slower charge dissipation rate,which can better restrain the corona discharge of HVDC transmission lines.
基金Supported by the National Science Fund for Distinguished Young Scholars under Grant 52025073 and the Zhenjiang Key Research Program under Grant GY2020011.
文摘A modified four-dimensional linear active disturbance rejection control(LADRC)strategy is proposed for a dual three-phase permanent magnet synchronous generator(DTP-PMSG)system to reduce cross-coupling between the d and q axis currents in the d-q subspace and harmonic currents in the x-y subspace.In the d-q subspace,the proposed strategy uses a model-based LADRC to enhance the decoupling effect between the d and q axes and the disturbance rejection ability against parameter variation.In the x-y subspace,the 5th and 7th harmonic current suppression abilities are improved by using quasi-resonant units parallel to the extended state observer of the traditional LADRC.The proposed modified LADRC strategy improved both the steady-state performance and dynamic response of the DTP-PMSG system.The experimental results demonstrate that the proposed strategy is both feasible and effective.
文摘A design scheme of the intelligent SSB (Solid State Breaker) based on the IGCT (Integrated Gate Commutated Thyris- tor) is presented. The topology of switch module and the structure of the SSB are proposed. Firstly, to the IGCT’s over-voltage sensitivity problem, a new technique of reducing the over-voltage is introduced, which releases the elect romantics energy of faulty line by a capacitive current branch to reduce the amplitude of over-voltage. Secondly, the principle of over-voltage suppression with current release branch is analyzed, and the overall control scheme of solid- state breaker is put forward. Finally, the simulation results also demonstrate its obvious effectiveness in over-voltage suppression after adding a current release branch into the SSB.
基金supported by National Natural Science Foundation of China(No.11575240)Key Program of Research and Development of Hefei Science Center,CAS(grant 2016HSC-KPRD002)
文摘Neutral beam injection is one of the effective auxiliary heating methods in magnetic-confinementfusion experiments. In order to acquire the suppressor-grid current signal and avoid the grid being damaged by overheating, a data acquisition and over-current protection system based on the PXI(PCI e Xtensions for Instrumentation) platform has been developed. The system consists of a current sensor, data acquisition module and over-current protection module. In the data acquisition module,the acquired data of one shot will be transferred in isolation and saved in a data-storage server in a txt file. It can also be recalled using NBWave for future analysis. The over-current protection module contains two modes: remote and local. This gives it the function of setting a threshold voltage remotely and locally, and the forbidden time of over-current protection also can be set by a host PC in remote mode. Experimental results demonstrate that the data acquisition and overcurrent protection system has the advantages of setting forbidden time and isolation transmission.
文摘电网换相换流器型高压直流输电(line commutated converter-based high voltage direct current,LCC-HVDC)系统若发生后续换相失败,将严重影响交直流混联电网的安全稳定运行。文中首先针对LCC-HVDC系统故障恢复过程中电流偏差控制作用阶段易再次发生换相失败的问题,对电流偏差控制参数与换相失败之间的关系进行理论分析,发现此阶段系统若不发生换相失败,逆变侧LCC直流电压和交流换相电压须满足一定的约束关系,且该约束关系受电流偏差控制参数的直接影响。然后,基于理论分析结果,提出一种电流偏差控制参数整定方法,可改善系统故障恢复过程中对直流电压恢复速度和程度的控制要求,使系统更易满足直流电压与交流换相电压稳定运行约束关系,以降低后续换相失败概率。最后,利用PSCAD/EMTDC仿真平台CIGRE标准测试模型验证了理论分析的正确性以及参数整定方法的有效性。
文摘基于模块化多电平变换器的固态变压器(modular multilevel converter based solid state transformer,MMC-SST)是实现交直流混合配电网柔性互联及能量多向流动的关键装备。针对固态变压器输入级MMC子模块电容纹波电压过大,导致装置的体积和成本增加的问题,提出一种基于比例重复控制的MMC-SST改进纹波电压抑制策略。首先利用基于比例重复控制的电容电压闭环得到调整后的功率移相角。然后,通过双有源桥变换器将子模块电容纹波功率传递到低压直流母线,从而有效抑制MMC子模块的各频次纹波电压,达到减小电容值的目的。最后,仿真结果表明在网侧电压对称或不对称工况下,基于比例重复控制的MMC-SST子模块电容纹波电压抑制策略均具有良好的纹波电压抑制能力。