Analysis of thermohaline and current distribution characteristics of Zhejiang and Fujian waters in summer 被引量:4
1
作者 DU Panjun ZHANG Hui +2 位作者 XIAO Wenjun KANG Xing GUAN Qinle 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2011年第5期71-83,共13页
This paper analyzed the distribution of thermohaline and circulation characteristics of Zhejiang and Fujian waters,based on the cross-sectional thermohaline data and on current data (up to 30 d duration) at fixed-po... This paper analyzed the distribution of thermohaline and circulation characteristics of Zhejiang and Fujian waters,based on the cross-sectional thermohaline data and on current data (up to 30 d duration) at fixed-point moorings,collected in the summer of 2006.We also performed low-pass filtering and spectrum analysis on the mooring submersible buoy data.Based on that analysis,we discussed the characteristics of low frequency currents and time-variations in these waters.The main conclusions are as follows.(1) There is a low salinity pinnate area near the Hangzhou Bay in summer,and outside the low salinity area,an obvious salinity front is present from surface to bottom near 123 E.There is also a temperature front below the surface at a corresponding position.(2) Bottom water of the Taiwan Warm Current comes from the subsurface of Kuroshio.(3) The direction of low frequency current at fixed anchor stations is N-NE or S,which mainly depends on the interaction of control currents in this waters.(4) Significant spectral peaks at all mooring stations are typically semidiurnal and diurnal tides.Semidiurnal tidal waves are the main ones in these waters,and have more energy closer to the shore.(5) Significant energy spectral peaks of middle period (3 to 8 d) of currents are responses to weather frequency.(6) Significant energy spectral peaks of long periods at the surface or bottom are probably responses to seasonal wind or bottom friction,while,the long period peaks of other depths can reflect cyclical changes of interactions between currents.We conclude that the pulsation period of the Taiwan Warm Current in these waters is 10-17 d. 展开更多
关键词 Zhejiang and Fujian waters thermohaline distribution low-frequency current spectrum analysis Taiwan Warm current Kuroshio subsurface water
下载PDF
Current Density Distribution in Gas Tungsten Arc Welding Process 被引量:2
2
作者 Hongming GAO Lin WU Honggang DONG National Key Laboratory of Advanced Welding Production Technology, Harbin Institute of Technology, Harbin, 150001, China 《Journal of Shanghai Jiaotong university(Science)》 EI 2000年第1期123-127,共5页
Heat transfer and fluid flow in a weld pool had been simulated for several decades, which underwent from theoretically analysis to numerical solutions. Because of the complexity of the welding process, many ideal assu... Heat transfer and fluid flow in a weld pool had been simulated for several decades, which underwent from theoretically analysis to numerical solutions. Because of the complexity of the welding process, many ideal assumptions were made to simplify the question. This makes the solution somewhat not complied with the practical conditions. In previous papers, the current distribution in the weld pool is assumed as axi-symmetrical, and so does the electromagnetic forces, which plays an important role in determining the fluid flow field. Actually the current distribution is different from the assumption. In this paper; a three dimensional current distribution in Gas Tungsten Arc Welding (GTAW) process is performed. The current density distribution field is evaluated by numerically solving Maxwell’s equations in the domain of the workpiece. In the boundary condition, the current density on the top surface is assumed as Gaussian distribution. Results show that the current distribution in GTAW is not axi-symmetrical, and the relative location of the torch and the earth clamp influence the current distribution greatly. 展开更多
关键词 NUMERICAL SIMULATION GTAW current distribution
下载PDF
Microstructure and Temperature Distribution in ZnAl_2O_4 Sintered Body by Pulse Electric Current 被引量:3
3
作者 Dongming ZHANG, Zhengyi FU and Jingkun GUOState Key Lab. of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Wuhan 430070, China 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2003年第6期526-528,共3页
Microstructure of reaction sintering of ZnAl2O4 at 1500℃ by hot-pressing(HP) and pulse electric current was investigated. The results indicated that the existed cracks in sintered body were caused by structure mismat... Microstructure of reaction sintering of ZnAl2O4 at 1500℃ by hot-pressing(HP) and pulse electric current was investigated. The results indicated that the existed cracks in sintered body were caused by structure mismatch. It is the evidence that periodical temperature field existed during pulse electric current sintering of nonconductive materials. The distance between high temperature areas was related to die diameter. 展开更多
关键词 Pulse electric current sintering Reaction sintering ZnAl2O4 Microstructure Temperature distribution.
下载PDF
Numerical Simulation of Current Density Distribution in Keyhole Double-Sided Arc Welding 被引量:3
4
作者 JunshengSUN ChuansongWU +1 位作者 MinZHANG HouxiaoWANG 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2004年第2期228-231,共4页
In the double-sided arc welding system (DSAW) composing of PAW+TIG arcs, the PAW arc is guided by the TIG arc so that the current mostly flows through the direction of the workpiece thickness and the penetration is gr... In the double-sided arc welding system (DSAW) composing of PAW+TIG arcs, the PAW arc is guided by the TIG arc so that the current mostly flows through the direction of the workpiece thickness and the penetration is greatly improved. To analyze the current density distribution in DSAW is beneficial to understanding of this process. Considering all kinds of dynamic factors acting on the weldpool, this paper discusses firstly the surface deformation of the weldpool and the keyhole formation in PAW+TIG DSAW process on the basis of the magnetohydrodynamic theory and variation principles. Hence, a model of the current density distribution is developed. Through numerical simulation, the current density distribution in PAW+TIG DSAW process is quantitatively analyzed. It shows that the minimal radius of keyhole formed in PAW+TIG DSAW process is 0.5 mm and 89.5 percent of current flows through the keyhole. 展开更多
关键词 PAW+TIG double-sided arc welding Surface deformation of the weldpool KEYHOLE current density distribution
下载PDF
Effect of pulsed current on temperature distribution,weld bead profiles and characteristics of gas tungsten arc welded aluminum alloy joints 被引量:6
5
作者 N.KARUNAKARAN V.BALASUBRAMANIAN 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2011年第2期278-286,共9页
Temperature distribution and weld bead profiles of constant current and pulsed current gas tungsten arc welded aluminium alloy joints were compared. The effects of pulsed current welding on tensile properties, hardnes... Temperature distribution and weld bead profiles of constant current and pulsed current gas tungsten arc welded aluminium alloy joints were compared. The effects of pulsed current welding on tensile properties, hardness profiles, microstructural features and residual stress distribution of aluminium alloy joints were reported. The use of pulsed current technique is found to improve the tensile properties of the weld compared with continuous current welding due to grain refinement occurring in the fusion zone. 展开更多
关键词 aluminium alloy gas tungsten arc welding pulsed current temperature distribution bead profiles tensile properties
下载PDF
Mechanical property and deformation mechanism of gold nanowire with non-uniform distribution of twinned boundaries:A molecular dynamics simulation study 被引量:2
6
作者 Qi-Xin Xiao Zhao-Yang Hou +1 位作者 Chang Li Yuan Niu 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第5期520-525,共6页
The mechanical property and deformation mechanism of twinned gold nanowire with non-uniform distribution of twinned boundaries(TBs)are studied by the molecular dynamics(MD)method.It is found that the twin boundary spa... The mechanical property and deformation mechanism of twinned gold nanowire with non-uniform distribution of twinned boundaries(TBs)are studied by the molecular dynamics(MD)method.It is found that the twin boundary spacing(TBS)has a great effect on the strength and plasticity of the nanowires with uniform distribution of TBs.And the strength enhances with the decrease of TBS,while its plasticity declines.For the nanowires with non-uniform distribution of TBs,the differences in distribution among different TBSs have little effect on the Young's modulus or strength,and the compromise in strength appears.But the differences have a remarkable effect on the plasticity of twinned gold nanowire.The twinned gold nanowire with higher local symmetry ratio has better plasticity.The initial dislocations always form in the largest TBS and the fracture always appears at or near the twin boundaries adjacent to the smallest TBS.Some simulation results are consistent with the experimental results. 展开更多
关键词 twin nanowire GOLD non-uniform distribution mechanical property molecular dynamics simulation
原文传递
Reconstruction of Current Density Distribution in Weld Area During Resistance Spot Welding of Aluminum Alloy Based on Magnetic Field 被引量:1
7
作者 单平 姚杞 +1 位作者 李洋 罗震 《Transactions of Tianjin University》 EI CAS 2015年第2期129-134,共6页
Magnetic flux density around the weld area was used to reconstruct the current density distribution during resistance spot welding(RSW) of aluminum alloy according to inverse problem theory. A current-magnetic field m... Magnetic flux density around the weld area was used to reconstruct the current density distribution during resistance spot welding(RSW) of aluminum alloy according to inverse problem theory. A current-magnetic field model was established and the conjugate gradient method was used to solve this model. The results showed that the current density was low at the center of nugget while high on the edge of nugget. Moreover, the welding time of 30ms—60 ms is a key period for nucleation. The current density distribution can reflect whether the weld nugget is formed or splashed, therefore it has the potential to monitor the weld quality of RSW. 展开更多
关键词 resistance SPOT welding current density distribution INVERSE problem magnetic field
下载PDF
Plating current density distribution of lithium metal anodes in pouch cells 被引量:2
8
作者 Shi-Jie Yang Xin Shen +5 位作者 Xin-Bing Cheng Feng-Ni Jiang Rui Zhang He Liu Lei Liu Hong Yuan 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2022年第6期70-75,I0003,共7页
The uniformity of current density distribution upon electrodes is one of the most important factors determining the lithium dendrites growth and cycling performance of lithium metal batteries(LMBs). Herein,current den... The uniformity of current density distribution upon electrodes is one of the most important factors determining the lithium dendrites growth and cycling performance of lithium metal batteries(LMBs). Herein,current density distributions of lithium metal anodes induced by various engineering factors, consisting of uneven cathode, electrolyte distribution, and different tab positions, and their effects on the electrochemical performance are investigated theoretically and experimentally in pouch cells. The deviation of current density in lithium metal anodes ranges from 2.47% to 196.18% due to the different levels of uneven cathode materials. However, the deviation is just 13.60% for different electrolyte thicknesses between cathodes and anodes, even a ten-layer separator in some positions. The maximum deviation for variational tab positions is only 0.17%. The nonuniformity in current density distribution results in severe dendrite growth issues and poor electrochemical performance of LMBs. This work not only confirms the direct correlation between the uneven current density distribution and lithium deposition behaviors, but also points out the decisive effects of cathode surface roughness on current distribution of anodes, to which more attentions should be paid in practical applications of LMBs. 展开更多
关键词 Pouch cell Lithium metal anode DENDRITE current density distribution Safety
下载PDF
Effects of drive current rise-time and initial load density distribution on Z-pinch characteristics 被引量:1
9
作者 段耀勇 郭永辉 +1 位作者 王文生 邱爱慈 《Chinese Physics B》 SCIE EI CAS CSCD 2005年第9期1856-1861,共6页
A two-dimensional, three-temperature radiation magneto-hydrodynamics model is applied to the investigation of evolutional trends in x-ray radiation power, energy, peak plasma temperature and density as functions of dr... A two-dimensional, three-temperature radiation magneto-hydrodynamics model is applied to the investigation of evolutional trends in x-ray radiation power, energy, peak plasma temperature and density as functions of drive current rise-time and initial load density distribution by using the typical experimental parameters of tungsten wire-array Z- pinch on the Qiangguang-I generator. The numerical results show that as the drive current rise-time is shortened, x-ray radiation peak power, energy, peak plasma density and peak ion temperature increase approximately linearly, but among them the x-ray radiation peak power increases more quickly. As the initial plasma density distribution in the radial direction becomes gradually flattened, the peak radiation power and the peak ion-temperature almost exponentially increase, while the radiation energy and the peak plasma density change only a little. The main effect of shortening drive current rise-time is to enhance compression of plasma, and the effect of flattening initial load density distribution in the radial direction is to raise the plasma temperature. Both of the approaches elevate the x-ray peak radiation power 展开更多
关键词 Z-PINCH drive current rise-time initial load density distribution numerical simulation
原文传递
Memristor Hypothesis in Malignant Charge Distribution
10
作者 Andras Szasz 《Open Journal of Biophysics》 2023年第4期51-92,共42页
Tissues in biological objects from the point of view of electromagnetic effects must be modeled not only for their conductivity. The ionic double layer induced by the electric field, built by electrolytic diffusion, m... Tissues in biological objects from the point of view of electromagnetic effects must be modeled not only for their conductivity. The ionic double layer induced by the electric field, built by electrolytic diffusion, must be counted. The micro (frequency dispersion phenomena) and macro (interfacial polarization), as well as more generalized by Nernst-Planck cells describe the biophysical aspects of this phenomena. The charge distribution depends on the processes and produces charge gradients in space. The dynamic feasibility of the-charge transition layer has memory and adaptability, working like a memristor in cancerous development. The memristor processes may complete the adaptation mechanisms of cancer cells to extremely stressful conditions. Our objective is to show the distribution and redistribution of space charges that generate memristors and internal currents like injury current (IC) in the development of cancer. We show some connected aspects of the modulated electrohyperthermia (mEHT) limiting the proliferation process in the micro-range like the macro-range electrochemotherapy (ECT) processes do. The internal polarization effects form space-charge, which characteristically differ in malignant and healthy environments. The electrical resistivity of the electrolytes depends on the distribution of the charges and concentrations of ions in the electrolytes, consequently the space-charge differences appear in the conductivity parameters too. The polarization heterogeneities caused by the irregularities of the healthy tissue induce a current (called injury current), which appears in the cancerous tumor as well. Due to the nonlinearity of the space-charge production and the differences of the relaxation time of the processes in various subunits. The tumor develops the space-charge which appears as an inductive component in the otherwise capacitive setting and forms a memristive behavior of the tumorous tissue. This continuously developing space-charge accommodates the tumor to the permanently changing conditions and helps the adopting the malignant cells in the new environment. Applying external radiofrequency electric field, the disturbance of the space-charge may change the conditions, and seek to reestablish the healthy homeostatic equilibrium, blocking the pathologic injury current components. The hypothetical memristive behavior of the tumor microenvironment and the tumor mass may be a biophysical addition to the adaption mechanisms of tumor cell and could provide a way to block the pathogen biophysical processes. An electric field in the direction of the place of disturbance from the healthy neighborhood appears, starting a current, which promotes cell migrations and wound healing, re-establishing homeostatic equilibrium. In pathological disturbance, the same process starts, which supports further proliferation, so its blocking is desired. 展开更多
关键词 MALIGNANCY TUMORS MEMRISTOR Imperfect Dielectrics Heterogeneity Charge distribution Injury current Nernst-Planck Cell
下载PDF
Study on Earth Surface Potential and DC Current Distribution around DC Grounding Electrode 被引量:1
11
作者 Zhi-chao Ren Chun-yan Ye Hai-yan Wang 《Energy and Power Engineering》 2013年第4期792-796,共5页
DC magnetic biasing problem,caused by the DC grounding electrode, threatened the safe operation of AC power grid. In this paper, the characteristics of the soil stratification near DC grounding electrode was researche... DC magnetic biasing problem,caused by the DC grounding electrode, threatened the safe operation of AC power grid. In this paper, the characteristics of the soil stratification near DC grounding electrode was researched. The AC-DC interconnected large-scale system model under the monopole operation mode was established. The earth surface potential and DC current distribution in various stations under the different surface thickness was calculated. Some useful conclusions are drawn from the analyzed results. 展开更多
关键词 DC GROUNDING ELECTRODE Magnetic BIASING Soil STRATIFICATION Earth Surface Potential DC current distribution
下载PDF
Simulation on DC Current Distribution in AC Power Grid under HVDC Ground-Return-Mode 被引量:1
12
作者 Guihua Mei Yuanzhang Sun Yancun Liu 《Journal of Electromagnetic Analysis and Applications》 2010年第7期418-423,共6页
This paper focus on the Modeling and Calculation of DC current distribution in AC power grid induced under HVDC Ground-Return-Mode. Applying complex image method and boundary element method, a new field-circuit coupli... This paper focus on the Modeling and Calculation of DC current distribution in AC power grid induced under HVDC Ground-Return-Mode. Applying complex image method and boundary element method, a new field-circuit coupling model was set up. Based on the calculation result with complex image method, this paper derived the modification factor for induced earth potential from practical measurement, which increased the accuracy of calculation. The modification method is helpful for evaluation on the effect of means used for blocking the dc-bias current in transformer neutral and also useful for the forecast of the DC current distribution when the power grid is in different line connection mode. The DC distribution character in Guangdong power grid is shown and suggestion is proposed that the mitigation of dc-bias should start from those substations whose earth-potential is highest. 展开更多
关键词 HVDC DC-Bias DC distribution Ground-Return current SIMULATION
下载PDF
RELOCATION ALGORITHM FOR NON-UNIFORM DISTRIBUTION IN MOBILE SENSOR NETWORK 被引量:1
13
作者 Pei Zhiqiang Xu Changqing Teng Jing 《Journal of Electronics(China)》 2009年第2期222-228,共7页
Energy is the determinant factor for the survival of Mobile Sensor Networks(MSN).Based on the analysis of the energy distribution in this paper,a two-phase relocation algorithm is proposed based on the balance between... Energy is the determinant factor for the survival of Mobile Sensor Networks(MSN).Based on the analysis of the energy distribution in this paper,a two-phase relocation algorithm is proposed based on the balance between the energy provision and energy consumption distribution.Our main objectives are to maximize the coverage percentage and to minimize the total distance of node movements.This algorithm is designed to meet the requirement of non-uniform distribution network applications,to extend the lifetime of MSN and to simplify the design of the routing protocol.In ad-dition,test results show the feasibility of our proposed relocation algorithm. 展开更多
关键词 Mobile Sensor Networks(MSN) Energy balance Energy distribution non-uniform distribution
下载PDF
Value of Topology Approach to Diagnose of CAD Based on Magnetocardiographic Current Distribution Maps in Difficult-to-Diagnose Patients 被引量:2
14
作者 I. Chaikovsky L. Stadnyuk +5 位作者 A. Verba Yu. Vasetskyi M. Budnyk G. Mjasnikov A. Kazmirchuk A. Lomakovskyi 《World Journal of Cardiovascular Diseases》 2016年第7期235-245,共12页
Objective: The purpose of this work is to examine the usefulness of the topological approach for analysis of current density maps during ST-T interval in detection of coronary artery disease (CAD) in patients with pro... Objective: The purpose of this work is to examine the usefulness of the topological approach for analysis of current density maps during ST-T interval in detection of coronary artery disease (CAD) in patients with proved CAD but normal results of routine tests. Materials and Methods: The patient group included 123 patients. Coronary angiography was done due to chest pain. The control group consisted of 124 healthy volunteers. The MCG test was done by 4-channels MCG system installed at unshielded setting. An integral topological index Kideal, consisting of 4 parameters, has been counted. Results and Conclusions: It is shown that Kideal was higher in patient group compared to control one. Sensitivity was 87%, and specificity was 64%. The topological analysis of MCG current density maps is a valuable tool in noninvasive detection of CAD in difficult-to-diagnose patients with uninformative results of routine tests. 展开更多
关键词 MAGNETOCARDIOGRAPHY Coronary Artery Disease current distribution Difficult-to-Diagnose Patients Topology Parameters
下载PDF
Spatial Distribution Characteristics of Surface Tidal Currents in the Southwest of Taiwan Strait 被引量:1
15
作者 SHEN Zhiben WU Xiongbin +3 位作者 LIN Hang CHEN Xiaofeng XU Xing’an LI Lun 《Journal of Ocean University of China》 SCIE CAS 2014年第6期971-978,共8页
This study was conducted on the spatial distribution characteristics of surface tidal currents in the southwestern Taiwan Strait based on the quasi-harmonic analysis of current data obtained by two high frequency surf... This study was conducted on the spatial distribution characteristics of surface tidal currents in the southwestern Taiwan Strait based on the quasi-harmonic analysis of current data obtained by two high frequency surface wave radar(HFSWR) systems. The analysis shows that the tidal current pattern in the southwestern Taiwan Strait is primarily semi-diurnal and influenced significantly by shallow water constituents. The spatial distribution of tidal current ellipses of M2 is probably affected by the interaction between two different systems of tide wave, one from the northern mouth of Taiwan Strait and the other from the Bashi Channel. The directions of the major axes of M2 tidal current ellipses coincide roughly with the axis of the Taiwan Strait. The spatial distribution of the magnitudes of the probable maximum current velocity(PMCS) shows gradual increase of the velocity from northeast to southwest, which is in accordance with the spatial distribution of the measured maximum current velocity(MMCS). The directions of the residual currents are in accordance with the direction of the prevailing monsoon wind at the Taiwan Strait and the direction of the Taiwan warm current during summer. The bathymetry also shows a significant effect on the spatial distribution characteristics of tidal currents. 展开更多
关键词 high frequency surface wave radar quasi-harmonic analysis spatial distribution characteristic surface tidal current Taiwan Strait
下载PDF
Plasma current tomography for HL-2A based on Bayesian inference
16
作者 刘自结 王天博 +5 位作者 吴木泉 罗正平 王硕 孙腾飞 肖炳甲 李建刚 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第5期165-173,共9页
An accurate plasma current profile has irreplaceable value for the steady-state operation of the plasma.In this study,plasma current tomography based on Bayesian inference is applied to an HL-2A device and used to rec... An accurate plasma current profile has irreplaceable value for the steady-state operation of the plasma.In this study,plasma current tomography based on Bayesian inference is applied to an HL-2A device and used to reconstruct the plasma current profile.Two different Bayesian probability priors are tried,namely the Conditional Auto Regressive(CAR)prior and the Advanced Squared Exponential(ASE)kernel prior.Compared to the CAR prior,the ASE kernel prior adopts nonstationary hyperparameters and introduces the current profile of the reference discharge into the hyperparameters,which can make the shape of the current profile more flexible in space.The results indicate that the ASE prior couples more information,reduces the probability of unreasonable solutions,and achieves higher reconstruction accuracy. 展开更多
关键词 plasma current tomography Bayesian inference machine learning Gaussian distribution
下载PDF
Mitigation of Distributed Generation Impact on Protective Devices in a Distribution Network by Superconducting Fault Current Limiter
17
作者 Yu Zhao Yong Li +1 位作者 Tapan Kumar Saha Olav Krause 《Energy and Power Engineering》 2013年第4期258-263,共6页
Protection of radial distribution networks is widely based on coordinated inverse time overcurrent relays (OCRs) ensuring both effectiveness and selectivity. However, the integration of distributed generation (DG) int... Protection of radial distribution networks is widely based on coordinated inverse time overcurrent relays (OCRs) ensuring both effectiveness and selectivity. However, the integration of distributed generation (DG) into an existing distribution network not only inevitably increases fault current levels to levels that may exceed the OCR ratings, but it may also disturb the original overcurrent relay coordination adversely effecting protection selectivity. To analyze the potentially adverse impact of DG on distribution system protective devices with respect to circuit breaker ratings and OCR coordination fault current studies are carried out for common reference test system under the influence of additional DG. The possible advantages of Superconducting Fault Current Limiter (SFCL) as a means to limit the adverse effect of DG on distribution system protection and their effectiveness will be demonstrated. Furthermore, minimum SFCL impedances required to avoid miss-operation of the primary and back-up OCRs are determined. The theoretical analysis will be validated using the IEEE 13-bus distribution test system is used. Both theoretical and simulation results indicate that the proposed application of SFCL is a viable option to effectively mitigate the DG impact on protective devices, thus enhancing the reliability of distribution network interfaced with DG. 展开更多
关键词 OVERcurrent Relay (OCR) distribution Protection Coordination distributed Generation (DG) FAULT current Superconducting FAULT current LIMITER (SFCL)
下载PDF
Input Admittance and Current Distribution of Infinitely Long Circular Cylindrical Antenna Driven at Center
18
作者 Jinxion Chen & Guotai YinBeijing Institute of Radio Measurement, P.O.Box 3923, Beijing 100854, China 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 1991年第2期73-81,共9页
In this paper, by change of integration path in complex spectrum domain and by defining input admittance as the ratio of complex radiated power to amplitude of square of voltage across the gap, new expressions of admi... In this paper, by change of integration path in complex spectrum domain and by defining input admittance as the ratio of complex radiated power to amplitude of square of voltage across the gap, new expressions of admittance (valid for all frequencies ) of infinitely long cylindrical antenna with and without conducting ground are obtained. Meanwhile corresponding formulas of current distribution are derived in detail. Some numerical computations are also given. 展开更多
关键词 Input admittance current distribution Long cylindrical antenna.
下载PDF
Study on Distribution Coefficient of Traction Return Current in High-Speed Railway
19
作者 Wen Huang Zhengyou He +2 位作者 Zhengyou He Haitao Hu Qi Wang 《Energy and Power Engineering》 2013年第4期1253-1258,共6页
The distribution coefficient of return current network is an important method to decrease the rail potential. In order to resolve the problem of high rail potential in high-speed railway based on EN50122-1 and Pr EN50... The distribution coefficient of return current network is an important method to decrease the rail potential. In order to resolve the problem of high rail potential in high-speed railway based on EN50122-1 and Pr EN50170 the distribution coefficient of longitudinal traction return current conductors is calculated through changing the interval of transverse connection. Based on field data and theoretical analysis, the parameters of longitudinal traction return current conductors are calculated. Results indicate that the best distance of the transverse connection is 400 m – 600 m. 展开更多
关键词 TRACTION RETURN current RAIL Potential distribution Coefficient Interval of TRANSVERSE Connection
下载PDF
Single-phase earth fault current distribution between optical fiber composite overhead ground wire and ordinary ground wire in transmission system
20
作者 许高雄 《Journal of Chongqing University》 CAS 2011年第2期78-83,共6页
It is important for the safety of transmission system to accurately calculate single-phase earth fault current distribution.Features of double sided elimination method were illustrated.Quantitative calculation of sing... It is important for the safety of transmission system to accurately calculate single-phase earth fault current distribution.Features of double sided elimination method were illustrated.Quantitative calculation of single-phase earth fault current distribution and case verification were accomplished by using the loop method.Influences of some factors,such as single-phase earth fault location and ground resistance of poles,on short-circuit current distribution were discussed.Results show that:1) results of the loop method conform to those of double sided elimination method;2) the fault location hardly influences macro-distribution of short-circuit current.However,current near fault location is evidently influenced;and 3) the short-circuit current distribution is not so sensitive to the ground resistance of poles. 展开更多
关键词 loop method single-phase earth fault short-circuit current distribution optical fiber composite overhead ground wire ordinary ground wire