The non-uniform temperature distribution of the main reflector of a large radio telescope may cause serious deformation of the main reflector,which will dramatically reduce the aperture efficiency of a radio telescope...The non-uniform temperature distribution of the main reflector of a large radio telescope may cause serious deformation of the main reflector,which will dramatically reduce the aperture efficiency of a radio telescope.To study the non-uniform temperature field of the main reflector of a large radio telescope,numerical calculations including thermal environment factors,the coefficients on convection and radiation,and the shadow boundary of the main reflector are first discussed.In addition,the shadow coverage and the non-uniform temperature field of the main reflector of a 70-m radio telescope under solar radiation are simulated by finite element analysis.The simulation results show that the temperature distribution of the main reflector under solar radiation is very uneven,and the maximum of the root mean square temperature is 12.3℃.To verify the simulation results,an optical camera and a thermal imaging camera are used to measure the shadow coverage and the non-uniform temperature distribution of the main reflector on a clear day.At the same time,some temperature sensors are used to measure the temperature at some points close to the main reflector on the backup structure.It has been verified that the simulation and measurement results of the shadow coverage on the main reflector are in good agreement,and the cosine similarity between the simulation and the measurement is above 90%.Despite the inevitable thermal imaging errors caused by large viewing angles,the simulated temperature field is similar to the measured temperature distribution of the main reflector to a large extent.The temperature trend measured at the test points on the backup structure close to the main reflector without direct solar radiation is consistent with the simulated temperature trend of the corresponding points on the main reflector with the solar radiation.It is credible to calculate the temperature field of the main reflector through the finite element method.This work can provide valuable references for studying the thermal deformation and the surface accuracy of the main reflector of a large radio telescope.展开更多
Called island-crossing tunnels,some specific underwater tunneling projects face constraints imposed by geological and water conditions,necessitating their passage through artificial or natural islands.The longitudinal...Called island-crossing tunnels,some specific underwater tunneling projects face constraints imposed by geological and water conditions,necessitating their passage through artificial or natural islands.The longitudinal of the tunnel follows aW-shaped distribution.The congestion situation does not allowfor immediate longitudinal smoke exhaust at the early stage of the fire,and the natural spread of smoke is complicated.An exhaustive investigation was carried out to analyze the smoke behaviors during a fire incident,employing the fire dynamics software FDS,considering five slopes and four fire locations.The simulation results reveal that the layer of high-temperature smoke becomes thicker as one gets closer to the fire source.The thermal pressure difference significantly impacts the temperature distribution within the tunnel and the distance of smoke spread.The value of the thermal pressure difference is significantly affected by changes in slope.It reaches a maximum of 157 Pa at a 5%slope,while it is only 41 Pa at a 1%slope when the fire occurs at the V-point.Fire hazards vary across locations within the W-shaped tunnel,necessitating separate consideration of the V-point and inverted V-point fire characteristics.The mass flow rate in small and large slope tunnels shows different decay rates due to variations in the main forces acting on the movement.Hence,two equations have been developed to predict the smoke mass flow rate,indicating a nonlinear relationship with the tunnel slope and the distance fromthe fire source.The tunnel slope inversely affects the smoke mass flowrate at the same location.The results can be utilized as a reference for conducting evacuation operations and aiding rescues during aW-shaped tunnel fire.展开更多
This study is to understand the impact of operating conditions, especially initial operation temperature (T<sub>ini</sub>) which is set in a high temperature range, on the temperature profile of the interf...This study is to understand the impact of operating conditions, especially initial operation temperature (T<sub>ini</sub>) which is set in a high temperature range, on the temperature profile of the interface between the polymer electrolyte membrane (PEM) and the catalyst layer at the cathode (i.e., the reaction surface) in a single cell of polymer electrolyte fuel cell (PEFC). A 1D multi-plate heat transfer model based on the temperature data of the separator measured using the thermograph in a power generation experiment was developed to evaluate the reaction surface temperature (T<sub>react</sub>). In addition, to validate the proposed heat transfer model, T<sub>react</sub> obtained from the model was compared with that from the 3D numerical simulation using CFD software COMSOL Multiphysics which solves the continuity equation, Brinkman equation, Maxwell-Stefan equation, Butler-Volmer equation as well as heat transfer equation. As a result, the temperature gap between the results obtained by 1D heat transfer model and those obtained by 3D numerical simulation is below approximately 0.5 K. The simulation results show the change in the molar concentration of O<sub>2</sub> and H<sub>2</sub>O from the inlet to the outlet is more even with the increase in T<sub>ini</sub> due to the lower performance of O<sub>2</sub> reduction reaction. The change in the current density from the inlet to the outlet is more even with the increase in T<sub>ini</sub> and the value of current density is smaller with the increase in T<sub>ini </sub>due to the increase in ohmic over-potential and concentration over-potential. It is revealed that the change in T<sub>react</sub> from the inlet to the outlet is more even with the increase in T<sub>ini</sub> irrespective of heat transfer model. This is because the generated heat from the power generation is lower with the increase in T<sub>ini </sub>due to the lower performance of O<sub>2</sub> reduction reaction.展开更多
Quantum key distribution(QKD)system based on passive silica planar lightwave circuit(PLC)asymmetric Mach–Zehnder interferometers(AMZI)is characterized with thermal stability,low loss and sufficient integration scalab...Quantum key distribution(QKD)system based on passive silica planar lightwave circuit(PLC)asymmetric Mach–Zehnder interferometers(AMZI)is characterized with thermal stability,low loss and sufficient integration scalability.However,waveguide stresses,both intrinsic and temperature-induced stresses,have significant impacts on the stable operation of the system.We have designed silica AMZI chips of 400 ps delay,with bend waveguides length equalized for both long and short arms to balance the stresses thereof.The temperature characteristics of the silica PLC AMZI chip are studied.The interference visibility at the single photon level is kept higher than 95%over a wide temperature range of 12℃.The delay time change is 0.321 ps within a temperature change of 40℃.The spectral shift is 0.0011 nm/0.1℃.Temperature-induced delay time and peak wavelength variations do not affect the interference visibility.The experiment results demonstrate the advantage of being tolerant to chip temperature fluctuations.展开更多
Climate change has resulted in serious social-economic ramifications and extremely catastrophic weather events in the world, Tanzania and Zanzibar in particular, with adaptation being the only option to reduce impacts...Climate change has resulted in serious social-economic ramifications and extremely catastrophic weather events in the world, Tanzania and Zanzibar in particular, with adaptation being the only option to reduce impacts. The study focuses on the influence of climate change and variability on spatio-temporal rainfall and temperature variability and distribution in Zanzibar. The station observation datasets of rainfall, T<sub>max</sub> and T<sub>min</sub> acquired from Tanzania Meteorological Authority (TMA) and the Coordinated Regional Climate Downscaling Experiment program (CORDEX) projected datasets from the Regional climate model HIRHAM5 under driving model ICHEC-EC-EARH, for the three periods of 1991-2020 used as baseline (HS), 2021-2050 as near future (NF) and 2051-2080 far future (FF), under two representative concentration pathways (RCP) of 4.5 and 8.5, were used. The long-term observed T<sub>max</sub> and T<sub>min</sub> were used to produce time series for observing the nature and trends, while the observed rainfall data was used for understanding wet and dry periods, trends and slope (at p ≤ 0.05) using the Standardized Precipitation Index (SPI) and the Mann Kendall test (MK). Moreover, the Quantum Geographic Information System (QGIS) under the Inverse Distance Weighting (IDW) interpolation techniques were used for mapping the three decades of 1991-2000 (hereafter D1), 2001-2010 (hereafter D2) and 2011-2020 (hereafter D3) to analyze periodical spatial rainfall distribution in Zanzibar. As for the projected datasets the Climate Data Operator Commands (CDO), python scripts and Grid analysis and Display System (GrADS) soft-wares were used to process and display the results of the projected datasets of rainfall, T<sub>max</sub> and T<sub>min</sub> for the HS, NF and FF, respectively. The results show that the observed T<sub>max</sub> increased by the rates of 0.035℃ yr<sup>-</sup><sup>1</sup> and 0.0169℃ yr<sup>-</sup><sup>1</sup>, while the T<sub>min</sub> was increased by a rate of 0.064℃ yr<sup>-</sup><sup>1</sup> and 0.104℃ yr<sup>-</sup><sup>1</sup> for Unguja and Pemba, respectively. The temporal distribution of wetness and dryness indices showed a climate shift from near normal to moderate wet during 2005 at Zanzibar Airport, while normal to moderately dry conditions, were observed in Pemba at Matangatuani. The decadal rainfall variability and distributions revealed higher rainfall intensity with an increasing trend and good spatial distribution in D3 from March to May (MAM) and October to December (OND). The projected results for T<sub>max</sub> during MAM and OND depicted higher values ranging from 1.7℃ - 1.8℃ to 1.9℃ - 2.0℃ and 1.5℃ to 2.0℃ in FF compared to NF under both RCPs. Also, higher T<sub>min</sub> values of 1.12℃ - 1.16℃ was projected in FF for MAM and OND under both RCPs. Besides, the rainfall projection generally revealed increased rainfall intensity in the range of 0 - 25 mm for Pemba and declined rainfall in the range of 25 - 50 mm in Unguja under both RCPs in perspectives of both NF and FF. Conclusively the study has shown that the undergoing climate change has posed a significant impact on both rainfall and temperature spatial and temporal distributions in Zanzibar (Unguja and Pemba), with Unguja being projected to have higher rainfall deficits while increasing rainfall strengths in Pemba. Thus, the study calls for more studies and formulation of effective adaptation, strategies and resilience mechanisms to combat the projected climate change impacts especially in the agricultural sector, water and food security.展开更多
An improved numerical simulation method is presented to calculate the downhole temperature distribution for multiple pay zones in producing oil wells. Based on hydrodynamics and heat transfer theory, a 2-D temperature...An improved numerical simulation method is presented to calculate the downhole temperature distribution for multiple pay zones in producing oil wells. Based on hydrodynamics and heat transfer theory, a 2-D temperature field model in cylindrical coordinates is developed. In the model, we considered general heat conduction as well as the heat convection due to fluid flow from porous formation to the borehole. We also take into account the fluid velocity variation in the wellbore due to multiple pay zones. We present coupled boundary conditions at the interfaces between the wellbore and adjacent formation, the wellbore and pay zone, and the pay zone and adjacent formation. Finally, an alternating direction implicit difference method (ADI) is used to solve the temperature model for the downhole temperature distribution. The comparison of modeled temperature curve with actual temperature log indicates that simulation result is in general quite similar to the actual temperature log. We found that the total production rate, production time, porosity, thickness of pay zones, and geothermal gradient, all have effects on the downhole temperature distribution.展开更多
The temperature is one of the principal controlling parameters of oncological hyperthermia. However, local heating forms a complicated thermal distribution in space and has developed over time, too. The decisional fac...The temperature is one of the principal controlling parameters of oncological hyperthermia. However, local heating forms a complicated thermal distribution in space and has developed over time, too. The decisional factors are the heterogeneity of the targeted volume, the electrolyte perfusions controlled by thermal homeostasis, and the spreading of the heat energy with time. A further complication is that the energy absorption sharply changes by depth, so the spatiotemporal development of the temperature distribution requires specialized methods to control. Most of the temperature imaging facilities (thermography, radiometry, electric impedance tomography, etc.) are less precise than the medical practice needs. In contrast, precise point sensing (like thermocouples, thermistors, and fluoroptical methods) is invasive and measures only a discrete point in the robustly changing thermal map. The two most precise thermal imaging methods, computer tomography, and magnetic resonance are expensive and have numerous technical complications. Our objective is to show the complexity of the temperature distribution inside the human body, and offer a relatively simple and cheap method to visualize its spatiotemporal development. A novel emerging technology, the application of ultrasound microbubble contrast agents is a promising method for solving complicated tasks of thermal distribution deep inside the living body. Noteworthy, the temperature distribution does not determine the full hyperthermia process, nonthermal effects make considerable impact, too. Additionally to the difficulties to measure the thermal heterogeneity during hyperthermia in oncology, numerous nonthermal processes, molecular and structural changes are triggered by the incoming electromagnetic energy, which presently has no spatiotemporal visualization technique. Microbubble imaging has a suitable spatiotemporal thermal resolution, and also it is sensitive to nonthermal effects. Its application for characterization of the modulated electrohyperthermia (mEHT) may open a new theranostic facility, using the synergy of the thermal and nonthermal effects of the radiofrequency delivered energy. This complex approach gives facility to follow the mEHT processes, and the proposed microbubble ultrasound imaging has a particularly promising advantage sensing and acting also nonthermally, having potential to characterize the thermally conditioned nonthermal electromagnetic effects in oncologic hyperthermia. The mEHT combined with microbubble ultrasound images could be a robust theranostic method against cancer.展开更多
Defects in cast-in-situ piles have an adverse impact on load transfer at the pile‒soil interface and pile bearing capacity. In recent years, thermal integrity profiling (TIP) has been developed to measure temperature ...Defects in cast-in-situ piles have an adverse impact on load transfer at the pile‒soil interface and pile bearing capacity. In recent years, thermal integrity profiling (TIP) has been developed to measure temperature profiles of cast-in-situ piles, enabling the detection of structural defects or anomalies at the early stage of construction. However, using this integrity testing method to evaluate potential defects in cast-in-situ piles requires a comprehensive understanding of the mechanism of hydration heat transfer from piles to surrounding soils. In this study, small-scale model tests were conducted in laboratory to investigate the performance of TIP in detecting pile integrity. Fiber-optic distributed temperature sensing (DTS) technology was used to monitor detailed temperature variations along model piles in sand. Additionally, sensors were installed in sand to measure water content and matric suction. An interpretation method against available DTS-based thermal profiles was proposed to reveal the potential defective regions. It shows that the temperature difference between normal and defective piles is more obvious in wet sand. In addition, there is a critical zone of water migration in sand due to the water absorption behavior of cement and temperature transfer-induced water migration in the early-age concrete setting. These findings could provide important insight into the improvement of the TIP testing method for field applications.展开更多
A physics-based analytical expression that predicts the charge,electrical field and potential distributions along the gated region of the GaN HEMT channel has been developed.Unlike the gradual channel approximation(GC...A physics-based analytical expression that predicts the charge,electrical field and potential distributions along the gated region of the GaN HEMT channel has been developed.Unlike the gradual channel approximation(GCA),the proposed model considers the non-uniform variation of the concentration under the gated region as a function of terminal applied volt-ages.In addition,the model can capture the influence of mobility and channel temperature on the charge distribution trend.The comparison with the hydrodynamic(HD)numerical simulation showed a high agreement of the proposed model with numerical data for different bias conditions considering the self-heating and quantization of the electron concentration.The ana-lytical nature of the model allows us to reduce the computational and time cost of the simulation.Also,it can be used as a core expression to develop a complete physics-based transistorⅣmodel without GCA limitation.展开更多
By selecting the daily maximum temperatures during 1961-2005 in 35 representative stations in Liaoning Province, the temporal and spatial distribution characteristics of extremely maximum temperature event were studie...By selecting the daily maximum temperatures during 1961-2005 in 35 representative stations in Liaoning Province, the temporal and spatial distribution characteristics of extremely maximum temperature event were studied. By using REOF, the mean-square deviation and so on, the variation and distribution situation of extremely maximum temperature in the different regions of Liaoning were reflected. The results showed that the extremely maximum temperature in Liaoning Province could be divided into 3 regions where were respectively the northeast area, the west and the northwest area, the south and the southeast area. The distribution characteristic of extremely maximum temperature threshold value in Liaoning Province was basically consistent with the distribution characteristic of average temperature. The zone where the extremely maximum temperature threshold was relatively high was in the northwest area of Liaoning, and the low threshold zone was in the southeast area and most areas in the east. The variation of extremely maximum temperature in winter was the greatest and in summer was the smallest. The variation of extremely maximum temperature days was the greatest in summer and wasn’t great in spring, autumn, winter.展开更多
The effect of external roof shading on the spatial distribution of air temperature and relative humidity in a greenhouse(Tin and RHin) was evaluated under the arid climatic conditions of Riyadh City, Saudi Arabia. Two...The effect of external roof shading on the spatial distribution of air temperature and relative humidity in a greenhouse(Tin and RHin) was evaluated under the arid climatic conditions of Riyadh City, Saudi Arabia. Two identical, evaporatively-cooled, single-span greenhouses were used in the experiment. One greenhouse was externally shaded(Gs) using a movable black plastic net(30% transmissivity), and the other greenhouse was kept without shading(Gc). Strawberry plants were cultivated in both greenhouses. The results showed that the spatial distribution of the Tin and RHin was significantly affected by the outside solar radiation and evaporative cooling operation. The regression analysis showed that when the outside solar radiation intensity increased from 200 to 800 W m–2, the Tin increased by 4.5℃ in the Gc and 2℃in the Gs, while the RHin decreased by 15% in the Gc and 5% in the Gs, respectively. Compared with those in the Gc, more uniformity in the spatial distribution of the Tin and RHin was observed in the Gs. The difference between the maximum and minimum Tin of 6.4℃ and the RHin of 10% was lower in the Gs than those in the Gc during the early morning. Around 2℃ difference in the Tin was shown between the area closed to the exhausted fans and the area closed to the cooling pad with the external shading. In an evaporatively-cooled greenhouse in arid regions, the variation of the Tin and RHin in the vertical direction and along the sidewalls was much higher than that in the horizontal direction. The average variation of the Tin and RHin in the vertical direction was 5.2℃ and 10% in the Gc and 5.5℃ and 13% in the Gs, respectively. The external shading improved the spatial distribution of the Tin and RHin and improved the cooling efficiency of the evaporative cooling system by 12%, since the transmitted solar radiation and accumulated thermal energy in the greenhouse were significantly reduced.展开更多
Insulator becomes wet partially or completely, and the pollution layer on itbecomes conductive, when collecting pollutants for an extended period during dew, light rain, mist,fog or snow melting. Heavy rain is a compl...Insulator becomes wet partially or completely, and the pollution layer on itbecomes conductive, when collecting pollutants for an extended period during dew, light rain, mist,fog or snow melting. Heavy rain is a complicated factor that it may wash away the pollution layerwithout initiating other stages of breakdown or it may bridge the gaps between sheds to promoteflashover. The insulator with a conducting pollution layer being energized, can cause a surfaceleakage current to flow (also temperature-rise). As the surface conductivity is non-uniform, theconducting pollution layer becomes broken by dry bands (at spots of high current density),interrupting the flow of leakage current. Voltage across insulator gets concentrated across drybands, and causes high electric stress and breakdown (dry band arcing). If the resistance of theinsulator surface is sufficiently low, the dry band arcs can be propagated to bridge the terminalscausing flashover. The present paper concerns the evaluation of the temperature distribution alongthe surface of an energized artificially polluted insulator string.展开更多
Heat flux characteristics are critical to good quality welding obtained in the important engineering alloy A12024- T3 by the friction stir welding (FSW) process. In the present study, thermocouples in three differen...Heat flux characteristics are critical to good quality welding obtained in the important engineering alloy A12024- T3 by the friction stir welding (FSW) process. In the present study, thermocouples in three different configurations were amxed on the welding samples to measure the temperatures: in the first configuration, four thermocouples were placed at equivalent positions along one side of the welding direction; the second configuration involved two equivalent thermocouple locations on either side of the welding path; while the third configuration had all the thermocouples on one side of the layout but with unequal gaps from the welding line. A three-dimensional, non-linear ANSYS computational model, based on an approach applied to A12024-T3 for the first time, was used to simulate the welding temperature profiles obtained experimentally. The experimental thermal profiles on the whole were found to be in agreement with those calculated by the ANSYS model. The broad agreement between the two kinds of profiles validates the basis for derivation of the simulation model and provides an approach for the FSW simulation in A12024-T3 and is potentially more useful than models derived previously.展开更多
The PPG PITT-CHAR XP flame retardant system has been used by COOEC to preventing the thermal softening of steel in the high temperature,whose degradation temperature is 80 ℃.To prevent damage to PPG PITT-CHAR XP fire...The PPG PITT-CHAR XP flame retardant system has been used by COOEC to preventing the thermal softening of steel in the high temperature,whose degradation temperature is 80 ℃.To prevent damage to PPG PITT-CHAR XP fire retardant paint from excessive heat during welding,it is necessary to get accurately reserved area near the welding joints prior to welding. For the foregoing reasons,the 80 ℃ temperature field distribution of thick plate multi-pass welding was analyzed with SYSWELD.The influence of welding groove form and time interval on welding temperature field was also analyzed. Results showed that the range of 80 ℃ welding temperature field increased with the increasing of weld layers at first and then it inclined to stable value. Interpass time setting was crucial to control the range of 80 ℃ welding temperature field. It was also found that double V groove had better thermal diffusivity than double-bevel groove.And double-bevel groove was better than single V groove.展开更多
In the field of aerospace, high-speed trains and automobile, etc, analysis of temperature filed and scuffing failure of tapered roller bearings are more important than ever, and the scuffing failure of elements of suc...In the field of aerospace, high-speed trains and automobile, etc, analysis of temperature filed and scuffing failure of tapered roller bearings are more important than ever, and the scuffing failure of elements of such rolling bearings under heavy load and high speed still cannot be effectively predicted yet. A simplified model of tapered roller bearings consisted of one inner raceway, one outer raceway and a tapered roller was established, in which the interaction of several heat sources is ignored. The contact mechanics model, temperature model and model of scuffing failure are synthesized, and the corresponding computer programs are developed to analyze the effects of bearings parameters, different material and operational conditions on thermal performance of bearings, and temperature distribution and the possibility of surface scuffing are obtained. The results show that load, speed, thermal conductivity and tapered roller materials influence temperature rise and scuffing failure of bearings. Ceramic material of tapered roller results in the decrease of scuffing possibility of bearings to a high extent than the conventional rolling bearing steel. Compared with bulk temperature, flash temperature on the surfaces of bearing elements has a little influence on maximum temperature rise of bearing elements. For the rolling bearings operated under high speed and heavy load, this paper proposes a method which can accurately calculate the possibility of scuffing failure of rolling bearings.展开更多
To predicate the temperature distribution of concrete-filled steel tubes(CFSTs) being exposure to fire,a finite element analysis model was developed using a finite element package,ANSYS.A suggested value of contact th...To predicate the temperature distribution of concrete-filled steel tubes(CFSTs) being exposure to fire,a finite element analysis model was developed using a finite element package,ANSYS.A suggested value of contact thermal resistance was therefore proposed with the supporting of massive numbers of collected test data.Parametric analysis was conducted subsequently towards the cross-sectional temperature distribution of CFST columns in four-side fire,in which the exposure time,width of the cross section,steel ratio were taken into account with considering contact thermal resistance.It was found that contact thermal resistance has little effect on the overall temperature regulation with the exposure time,the width of cross-section or the change of steel ratio.However,great temperature dropping at the concrete adjacent to the contact interface,and gentle temperature increase at steel tube,exist if considering contact thermal resistance.The results of the study are expected to provide theoretical basis for the fire resistance behavior and design of the CFST columns being exposure to fire.展开更多
Aim To Research the temperature distribution in orthogonal metal machining and to build a finite element analysis model about the temperature distribution. Methods With the finite element method of thermal conductio...Aim To Research the temperature distribution in orthogonal metal machining and to build a finite element analysis model about the temperature distribution. Methods With the finite element method of thermal conduction, the temperature distributions in various machining conditions were computed according to the experimental data such as cutting force, shear angle, etc. Results The computational results agree with some classic experimental results, and thermal effect due to process parameters was observed. Conclusion The finite element analysis model is reasonable, and it's a feasible scheme for studying the temperature distribution in orthogonal metal machining system.展开更多
Microstructure of reaction sintering of ZnAl2O4 at 1500℃ by hot-pressing(HP) and pulse electric current was investigated. The results indicated that the existed cracks in sintered body were caused by structure mismat...Microstructure of reaction sintering of ZnAl2O4 at 1500℃ by hot-pressing(HP) and pulse electric current was investigated. The results indicated that the existed cracks in sintered body were caused by structure mismatch. It is the evidence that periodical temperature field existed during pulse electric current sintering of nonconductive materials. The distance between high temperature areas was related to die diameter.展开更多
Line-of-sight tunable-diode-laser absorption spectroscopy(LOS-TDLAS) with multiple absorption lines is introduced for non-uniform temperature measurement. Temperature binning method combined with Gauss–Seidel itera...Line-of-sight tunable-diode-laser absorption spectroscopy(LOS-TDLAS) with multiple absorption lines is introduced for non-uniform temperature measurement. Temperature binning method combined with Gauss–Seidel iteration method is used to measure temperature probability distribution function(PDF) along the line-of-sight(LOS). Through 100 simulated measurements, the variation of measurement accuracy is investigated with the number of absorption lines, the number of temperature bins and the magnitude of temperature non-uniformity. A field model with 2-T temperature distribution and15 well-selected absorption lines are used for the simulation study. The Gauss–Seidel iteration method is discussed for its reliability. The investigation result about the variation of measurement accuracy with the number of temperature bins is different from the previous research results.展开更多
基金the Astronomical Joint Fund of National Natural Science Foundation of China and Chinese Academy of Sciences(U1831114)the National Natural Science Foundation of China(11673040 and 11803053)。
文摘The non-uniform temperature distribution of the main reflector of a large radio telescope may cause serious deformation of the main reflector,which will dramatically reduce the aperture efficiency of a radio telescope.To study the non-uniform temperature field of the main reflector of a large radio telescope,numerical calculations including thermal environment factors,the coefficients on convection and radiation,and the shadow boundary of the main reflector are first discussed.In addition,the shadow coverage and the non-uniform temperature field of the main reflector of a 70-m radio telescope under solar radiation are simulated by finite element analysis.The simulation results show that the temperature distribution of the main reflector under solar radiation is very uneven,and the maximum of the root mean square temperature is 12.3℃.To verify the simulation results,an optical camera and a thermal imaging camera are used to measure the shadow coverage and the non-uniform temperature distribution of the main reflector on a clear day.At the same time,some temperature sensors are used to measure the temperature at some points close to the main reflector on the backup structure.It has been verified that the simulation and measurement results of the shadow coverage on the main reflector are in good agreement,and the cosine similarity between the simulation and the measurement is above 90%.Despite the inevitable thermal imaging errors caused by large viewing angles,the simulated temperature field is similar to the measured temperature distribution of the main reflector to a large extent.The temperature trend measured at the test points on the backup structure close to the main reflector without direct solar radiation is consistent with the simulated temperature trend of the corresponding points on the main reflector with the solar radiation.It is credible to calculate the temperature field of the main reflector through the finite element method.This work can provide valuable references for studying the thermal deformation and the surface accuracy of the main reflector of a large radio telescope.
文摘Called island-crossing tunnels,some specific underwater tunneling projects face constraints imposed by geological and water conditions,necessitating their passage through artificial or natural islands.The longitudinal of the tunnel follows aW-shaped distribution.The congestion situation does not allowfor immediate longitudinal smoke exhaust at the early stage of the fire,and the natural spread of smoke is complicated.An exhaustive investigation was carried out to analyze the smoke behaviors during a fire incident,employing the fire dynamics software FDS,considering five slopes and four fire locations.The simulation results reveal that the layer of high-temperature smoke becomes thicker as one gets closer to the fire source.The thermal pressure difference significantly impacts the temperature distribution within the tunnel and the distance of smoke spread.The value of the thermal pressure difference is significantly affected by changes in slope.It reaches a maximum of 157 Pa at a 5%slope,while it is only 41 Pa at a 1%slope when the fire occurs at the V-point.Fire hazards vary across locations within the W-shaped tunnel,necessitating separate consideration of the V-point and inverted V-point fire characteristics.The mass flow rate in small and large slope tunnels shows different decay rates due to variations in the main forces acting on the movement.Hence,two equations have been developed to predict the smoke mass flow rate,indicating a nonlinear relationship with the tunnel slope and the distance fromthe fire source.The tunnel slope inversely affects the smoke mass flowrate at the same location.The results can be utilized as a reference for conducting evacuation operations and aiding rescues during aW-shaped tunnel fire.
文摘This study is to understand the impact of operating conditions, especially initial operation temperature (T<sub>ini</sub>) which is set in a high temperature range, on the temperature profile of the interface between the polymer electrolyte membrane (PEM) and the catalyst layer at the cathode (i.e., the reaction surface) in a single cell of polymer electrolyte fuel cell (PEFC). A 1D multi-plate heat transfer model based on the temperature data of the separator measured using the thermograph in a power generation experiment was developed to evaluate the reaction surface temperature (T<sub>react</sub>). In addition, to validate the proposed heat transfer model, T<sub>react</sub> obtained from the model was compared with that from the 3D numerical simulation using CFD software COMSOL Multiphysics which solves the continuity equation, Brinkman equation, Maxwell-Stefan equation, Butler-Volmer equation as well as heat transfer equation. As a result, the temperature gap between the results obtained by 1D heat transfer model and those obtained by 3D numerical simulation is below approximately 0.5 K. The simulation results show the change in the molar concentration of O<sub>2</sub> and H<sub>2</sub>O from the inlet to the outlet is more even with the increase in T<sub>ini</sub> due to the lower performance of O<sub>2</sub> reduction reaction. The change in the current density from the inlet to the outlet is more even with the increase in T<sub>ini</sub> and the value of current density is smaller with the increase in T<sub>ini </sub>due to the increase in ohmic over-potential and concentration over-potential. It is revealed that the change in T<sub>react</sub> from the inlet to the outlet is more even with the increase in T<sub>ini</sub> irrespective of heat transfer model. This is because the generated heat from the power generation is lower with the increase in T<sub>ini </sub>due to the lower performance of O<sub>2</sub> reduction reaction.
基金Project supported by the National Key R&D Program of China (Grant No.2018YFA0306403)the Strategic Priority Research Program of Chinese Academy of Sciences (Grant No.XDB43000000)+1 种基金Innovation Program for Quantum Science and TechnologyComputer Interconnect Technology Alliance Funding (Grant No.20220103)。
文摘Quantum key distribution(QKD)system based on passive silica planar lightwave circuit(PLC)asymmetric Mach–Zehnder interferometers(AMZI)is characterized with thermal stability,low loss and sufficient integration scalability.However,waveguide stresses,both intrinsic and temperature-induced stresses,have significant impacts on the stable operation of the system.We have designed silica AMZI chips of 400 ps delay,with bend waveguides length equalized for both long and short arms to balance the stresses thereof.The temperature characteristics of the silica PLC AMZI chip are studied.The interference visibility at the single photon level is kept higher than 95%over a wide temperature range of 12℃.The delay time change is 0.321 ps within a temperature change of 40℃.The spectral shift is 0.0011 nm/0.1℃.Temperature-induced delay time and peak wavelength variations do not affect the interference visibility.The experiment results demonstrate the advantage of being tolerant to chip temperature fluctuations.
文摘Climate change has resulted in serious social-economic ramifications and extremely catastrophic weather events in the world, Tanzania and Zanzibar in particular, with adaptation being the only option to reduce impacts. The study focuses on the influence of climate change and variability on spatio-temporal rainfall and temperature variability and distribution in Zanzibar. The station observation datasets of rainfall, T<sub>max</sub> and T<sub>min</sub> acquired from Tanzania Meteorological Authority (TMA) and the Coordinated Regional Climate Downscaling Experiment program (CORDEX) projected datasets from the Regional climate model HIRHAM5 under driving model ICHEC-EC-EARH, for the three periods of 1991-2020 used as baseline (HS), 2021-2050 as near future (NF) and 2051-2080 far future (FF), under two representative concentration pathways (RCP) of 4.5 and 8.5, were used. The long-term observed T<sub>max</sub> and T<sub>min</sub> were used to produce time series for observing the nature and trends, while the observed rainfall data was used for understanding wet and dry periods, trends and slope (at p ≤ 0.05) using the Standardized Precipitation Index (SPI) and the Mann Kendall test (MK). Moreover, the Quantum Geographic Information System (QGIS) under the Inverse Distance Weighting (IDW) interpolation techniques were used for mapping the three decades of 1991-2000 (hereafter D1), 2001-2010 (hereafter D2) and 2011-2020 (hereafter D3) to analyze periodical spatial rainfall distribution in Zanzibar. As for the projected datasets the Climate Data Operator Commands (CDO), python scripts and Grid analysis and Display System (GrADS) soft-wares were used to process and display the results of the projected datasets of rainfall, T<sub>max</sub> and T<sub>min</sub> for the HS, NF and FF, respectively. The results show that the observed T<sub>max</sub> increased by the rates of 0.035℃ yr<sup>-</sup><sup>1</sup> and 0.0169℃ yr<sup>-</sup><sup>1</sup>, while the T<sub>min</sub> was increased by a rate of 0.064℃ yr<sup>-</sup><sup>1</sup> and 0.104℃ yr<sup>-</sup><sup>1</sup> for Unguja and Pemba, respectively. The temporal distribution of wetness and dryness indices showed a climate shift from near normal to moderate wet during 2005 at Zanzibar Airport, while normal to moderately dry conditions, were observed in Pemba at Matangatuani. The decadal rainfall variability and distributions revealed higher rainfall intensity with an increasing trend and good spatial distribution in D3 from March to May (MAM) and October to December (OND). The projected results for T<sub>max</sub> during MAM and OND depicted higher values ranging from 1.7℃ - 1.8℃ to 1.9℃ - 2.0℃ and 1.5℃ to 2.0℃ in FF compared to NF under both RCPs. Also, higher T<sub>min</sub> values of 1.12℃ - 1.16℃ was projected in FF for MAM and OND under both RCPs. Besides, the rainfall projection generally revealed increased rainfall intensity in the range of 0 - 25 mm for Pemba and declined rainfall in the range of 25 - 50 mm in Unguja under both RCPs in perspectives of both NF and FF. Conclusively the study has shown that the undergoing climate change has posed a significant impact on both rainfall and temperature spatial and temporal distributions in Zanzibar (Unguja and Pemba), with Unguja being projected to have higher rainfall deficits while increasing rainfall strengths in Pemba. Thus, the study calls for more studies and formulation of effective adaptation, strategies and resilience mechanisms to combat the projected climate change impacts especially in the agricultural sector, water and food security.
基金sponsored by the National Nature Science Foundation of China (Grant No. 40830424).
文摘An improved numerical simulation method is presented to calculate the downhole temperature distribution for multiple pay zones in producing oil wells. Based on hydrodynamics and heat transfer theory, a 2-D temperature field model in cylindrical coordinates is developed. In the model, we considered general heat conduction as well as the heat convection due to fluid flow from porous formation to the borehole. We also take into account the fluid velocity variation in the wellbore due to multiple pay zones. We present coupled boundary conditions at the interfaces between the wellbore and adjacent formation, the wellbore and pay zone, and the pay zone and adjacent formation. Finally, an alternating direction implicit difference method (ADI) is used to solve the temperature model for the downhole temperature distribution. The comparison of modeled temperature curve with actual temperature log indicates that simulation result is in general quite similar to the actual temperature log. We found that the total production rate, production time, porosity, thickness of pay zones, and geothermal gradient, all have effects on the downhole temperature distribution.
文摘The temperature is one of the principal controlling parameters of oncological hyperthermia. However, local heating forms a complicated thermal distribution in space and has developed over time, too. The decisional factors are the heterogeneity of the targeted volume, the electrolyte perfusions controlled by thermal homeostasis, and the spreading of the heat energy with time. A further complication is that the energy absorption sharply changes by depth, so the spatiotemporal development of the temperature distribution requires specialized methods to control. Most of the temperature imaging facilities (thermography, radiometry, electric impedance tomography, etc.) are less precise than the medical practice needs. In contrast, precise point sensing (like thermocouples, thermistors, and fluoroptical methods) is invasive and measures only a discrete point in the robustly changing thermal map. The two most precise thermal imaging methods, computer tomography, and magnetic resonance are expensive and have numerous technical complications. Our objective is to show the complexity of the temperature distribution inside the human body, and offer a relatively simple and cheap method to visualize its spatiotemporal development. A novel emerging technology, the application of ultrasound microbubble contrast agents is a promising method for solving complicated tasks of thermal distribution deep inside the living body. Noteworthy, the temperature distribution does not determine the full hyperthermia process, nonthermal effects make considerable impact, too. Additionally to the difficulties to measure the thermal heterogeneity during hyperthermia in oncology, numerous nonthermal processes, molecular and structural changes are triggered by the incoming electromagnetic energy, which presently has no spatiotemporal visualization technique. Microbubble imaging has a suitable spatiotemporal thermal resolution, and also it is sensitive to nonthermal effects. Its application for characterization of the modulated electrohyperthermia (mEHT) may open a new theranostic facility, using the synergy of the thermal and nonthermal effects of the radiofrequency delivered energy. This complex approach gives facility to follow the mEHT processes, and the proposed microbubble ultrasound imaging has a particularly promising advantage sensing and acting also nonthermally, having potential to characterize the thermally conditioned nonthermal electromagnetic effects in oncologic hyperthermia. The mEHT combined with microbubble ultrasound images could be a robust theranostic method against cancer.
基金The authors grate fully acknowledge the financial support provided by the National Natural Science Foundation of China(Grant Nos.42225702 and 42077235)the Open Research Project Program of the State Key Laboratory of Internet of Things for Smart City(University of Macao),China(Grant No.SKUoTSC(UM)-2021-2023/0RP/GA10/2022).
文摘Defects in cast-in-situ piles have an adverse impact on load transfer at the pile‒soil interface and pile bearing capacity. In recent years, thermal integrity profiling (TIP) has been developed to measure temperature profiles of cast-in-situ piles, enabling the detection of structural defects or anomalies at the early stage of construction. However, using this integrity testing method to evaluate potential defects in cast-in-situ piles requires a comprehensive understanding of the mechanism of hydration heat transfer from piles to surrounding soils. In this study, small-scale model tests were conducted in laboratory to investigate the performance of TIP in detecting pile integrity. Fiber-optic distributed temperature sensing (DTS) technology was used to monitor detailed temperature variations along model piles in sand. Additionally, sensors were installed in sand to measure water content and matric suction. An interpretation method against available DTS-based thermal profiles was proposed to reveal the potential defective regions. It shows that the temperature difference between normal and defective piles is more obvious in wet sand. In addition, there is a critical zone of water migration in sand due to the water absorption behavior of cement and temperature transfer-induced water migration in the early-age concrete setting. These findings could provide important insight into the improvement of the TIP testing method for field applications.
基金This work was supported by the National Natural Science Foundation of China(NSFC)under Grant 61774141.
文摘A physics-based analytical expression that predicts the charge,electrical field and potential distributions along the gated region of the GaN HEMT channel has been developed.Unlike the gradual channel approximation(GCA),the proposed model considers the non-uniform variation of the concentration under the gated region as a function of terminal applied volt-ages.In addition,the model can capture the influence of mobility and channel temperature on the charge distribution trend.The comparison with the hydrodynamic(HD)numerical simulation showed a high agreement of the proposed model with numerical data for different bias conditions considering the self-heating and quantization of the electron concentration.The ana-lytical nature of the model allows us to reduce the computational and time cost of the simulation.Also,it can be used as a core expression to develop a complete physics-based transistorⅣmodel without GCA limitation.
文摘By selecting the daily maximum temperatures during 1961-2005 in 35 representative stations in Liaoning Province, the temporal and spatial distribution characteristics of extremely maximum temperature event were studied. By using REOF, the mean-square deviation and so on, the variation and distribution situation of extremely maximum temperature in the different regions of Liaoning were reflected. The results showed that the extremely maximum temperature in Liaoning Province could be divided into 3 regions where were respectively the northeast area, the west and the northwest area, the south and the southeast area. The distribution characteristic of extremely maximum temperature threshold value in Liaoning Province was basically consistent with the distribution characteristic of average temperature. The zone where the extremely maximum temperature threshold was relatively high was in the northwest area of Liaoning, and the low threshold zone was in the southeast area and most areas in the east. The variation of extremely maximum temperature in winter was the greatest and in summer was the smallest. The variation of extremely maximum temperature days was the greatest in summer and wasn’t great in spring, autumn, winter.
文摘The effect of external roof shading on the spatial distribution of air temperature and relative humidity in a greenhouse(Tin and RHin) was evaluated under the arid climatic conditions of Riyadh City, Saudi Arabia. Two identical, evaporatively-cooled, single-span greenhouses were used in the experiment. One greenhouse was externally shaded(Gs) using a movable black plastic net(30% transmissivity), and the other greenhouse was kept without shading(Gc). Strawberry plants were cultivated in both greenhouses. The results showed that the spatial distribution of the Tin and RHin was significantly affected by the outside solar radiation and evaporative cooling operation. The regression analysis showed that when the outside solar radiation intensity increased from 200 to 800 W m–2, the Tin increased by 4.5℃ in the Gc and 2℃in the Gs, while the RHin decreased by 15% in the Gc and 5% in the Gs, respectively. Compared with those in the Gc, more uniformity in the spatial distribution of the Tin and RHin was observed in the Gs. The difference between the maximum and minimum Tin of 6.4℃ and the RHin of 10% was lower in the Gs than those in the Gc during the early morning. Around 2℃ difference in the Tin was shown between the area closed to the exhausted fans and the area closed to the cooling pad with the external shading. In an evaporatively-cooled greenhouse in arid regions, the variation of the Tin and RHin in the vertical direction and along the sidewalls was much higher than that in the horizontal direction. The average variation of the Tin and RHin in the vertical direction was 5.2℃ and 10% in the Gc and 5.5℃ and 13% in the Gs, respectively. The external shading improved the spatial distribution of the Tin and RHin and improved the cooling efficiency of the evaporative cooling system by 12%, since the transmitted solar radiation and accumulated thermal energy in the greenhouse were significantly reduced.
文摘Insulator becomes wet partially or completely, and the pollution layer on itbecomes conductive, when collecting pollutants for an extended period during dew, light rain, mist,fog or snow melting. Heavy rain is a complicated factor that it may wash away the pollution layerwithout initiating other stages of breakdown or it may bridge the gaps between sheds to promoteflashover. The insulator with a conducting pollution layer being energized, can cause a surfaceleakage current to flow (also temperature-rise). As the surface conductivity is non-uniform, theconducting pollution layer becomes broken by dry bands (at spots of high current density),interrupting the flow of leakage current. Voltage across insulator gets concentrated across drybands, and causes high electric stress and breakdown (dry band arcing). If the resistance of theinsulator surface is sufficiently low, the dry band arcs can be propagated to bridge the terminalscausing flashover. The present paper concerns the evaluation of the temperature distribution alongthe surface of an energized artificially polluted insulator string.
基金the University of Malaya (MU) that awarded UMRG Grants RG042/09AETand RG088/10AET to the authors for research work to beconducted at the University of MalayaSpecial thanks are given to CREAM-CIDB for providing partial financial support to the first author via Project CREAM/R&D-08//3/2(8)
文摘Heat flux characteristics are critical to good quality welding obtained in the important engineering alloy A12024- T3 by the friction stir welding (FSW) process. In the present study, thermocouples in three different configurations were amxed on the welding samples to measure the temperatures: in the first configuration, four thermocouples were placed at equivalent positions along one side of the welding direction; the second configuration involved two equivalent thermocouple locations on either side of the welding path; while the third configuration had all the thermocouples on one side of the layout but with unequal gaps from the welding line. A three-dimensional, non-linear ANSYS computational model, based on an approach applied to A12024-T3 for the first time, was used to simulate the welding temperature profiles obtained experimentally. The experimental thermal profiles on the whole were found to be in agreement with those calculated by the ANSYS model. The broad agreement between the two kinds of profiles validates the basis for derivation of the simulation model and provides an approach for the FSW simulation in A12024-T3 and is potentially more useful than models derived previously.
基金Project(No.2016ZDJS05B03)supported by Shandong Key ResearchDevelopment Plan,Project(No.17CX06005&No.18CX06054A)supported by Department of Science&Technology of Shandong Province the Fundamental Research Funds for the Central Universities
文摘The PPG PITT-CHAR XP flame retardant system has been used by COOEC to preventing the thermal softening of steel in the high temperature,whose degradation temperature is 80 ℃.To prevent damage to PPG PITT-CHAR XP fire retardant paint from excessive heat during welding,it is necessary to get accurately reserved area near the welding joints prior to welding. For the foregoing reasons,the 80 ℃ temperature field distribution of thick plate multi-pass welding was analyzed with SYSWELD.The influence of welding groove form and time interval on welding temperature field was also analyzed. Results showed that the range of 80 ℃ welding temperature field increased with the increasing of weld layers at first and then it inclined to stable value. Interpass time setting was crucial to control the range of 80 ℃ welding temperature field. It was also found that double V groove had better thermal diffusivity than double-bevel groove.And double-bevel groove was better than single V groove.
基金Supported by the Natural Science Foundation of China (Grant No.51375436)Natural Science Foundation of Zhejiang Province (Grant No.Z1100475)Project of Engineering Research Center for Sliding Bearing of Zhejiang Province (Contract No.2012E10028)
文摘In the field of aerospace, high-speed trains and automobile, etc, analysis of temperature filed and scuffing failure of tapered roller bearings are more important than ever, and the scuffing failure of elements of such rolling bearings under heavy load and high speed still cannot be effectively predicted yet. A simplified model of tapered roller bearings consisted of one inner raceway, one outer raceway and a tapered roller was established, in which the interaction of several heat sources is ignored. The contact mechanics model, temperature model and model of scuffing failure are synthesized, and the corresponding computer programs are developed to analyze the effects of bearings parameters, different material and operational conditions on thermal performance of bearings, and temperature distribution and the possibility of surface scuffing are obtained. The results show that load, speed, thermal conductivity and tapered roller materials influence temperature rise and scuffing failure of bearings. Ceramic material of tapered roller results in the decrease of scuffing possibility of bearings to a high extent than the conventional rolling bearing steel. Compared with bulk temperature, flash temperature on the surfaces of bearing elements has a little influence on maximum temperature rise of bearing elements. For the rolling bearings operated under high speed and heavy load, this paper proposes a method which can accurately calculate the possibility of scuffing failure of rolling bearings.
基金Sponsored by the National Natural Science Foundation of China(Grant No.50708028)the Postdoctoral Foundation of Heilongjiang Province(GrantNo.LBH-Q07048)
文摘To predicate the temperature distribution of concrete-filled steel tubes(CFSTs) being exposure to fire,a finite element analysis model was developed using a finite element package,ANSYS.A suggested value of contact thermal resistance was therefore proposed with the supporting of massive numbers of collected test data.Parametric analysis was conducted subsequently towards the cross-sectional temperature distribution of CFST columns in four-side fire,in which the exposure time,width of the cross section,steel ratio were taken into account with considering contact thermal resistance.It was found that contact thermal resistance has little effect on the overall temperature regulation with the exposure time,the width of cross-section or the change of steel ratio.However,great temperature dropping at the concrete adjacent to the contact interface,and gentle temperature increase at steel tube,exist if considering contact thermal resistance.The results of the study are expected to provide theoretical basis for the fire resistance behavior and design of the CFST columns being exposure to fire.
文摘Aim To Research the temperature distribution in orthogonal metal machining and to build a finite element analysis model about the temperature distribution. Methods With the finite element method of thermal conduction, the temperature distributions in various machining conditions were computed according to the experimental data such as cutting force, shear angle, etc. Results The computational results agree with some classic experimental results, and thermal effect due to process parameters was observed. Conclusion The finite element analysis model is reasonable, and it's a feasible scheme for studying the temperature distribution in orthogonal metal machining system.
基金This work was supported by the National Natural Science Foundation of China under grant No.50232020 and 50220160657.
文摘Microstructure of reaction sintering of ZnAl2O4 at 1500℃ by hot-pressing(HP) and pulse electric current was investigated. The results indicated that the existed cracks in sintered body were caused by structure mismatch. It is the evidence that periodical temperature field existed during pulse electric current sintering of nonconductive materials. The distance between high temperature areas was related to die diameter.
基金Project supported by the National Natural Science Foundation of China(Grant No.61108034)the Young Scientists Fund of the National Natural Science Foundation of China(Grant No.61205151)
文摘Line-of-sight tunable-diode-laser absorption spectroscopy(LOS-TDLAS) with multiple absorption lines is introduced for non-uniform temperature measurement. Temperature binning method combined with Gauss–Seidel iteration method is used to measure temperature probability distribution function(PDF) along the line-of-sight(LOS). Through 100 simulated measurements, the variation of measurement accuracy is investigated with the number of absorption lines, the number of temperature bins and the magnitude of temperature non-uniformity. A field model with 2-T temperature distribution and15 well-selected absorption lines are used for the simulation study. The Gauss–Seidel iteration method is discussed for its reliability. The investigation result about the variation of measurement accuracy with the number of temperature bins is different from the previous research results.