期刊文献+
共找到11,052篇文章
< 1 2 250 >
每页显示 20 50 100
Disease clearance in ulcerative colitis:A new therapeutic target for the future
1
作者 Syed Adeel Hassan Neeraj Kapur +2 位作者 Fahad Sheikh Anam Fahad Somia Jamal 《World Journal of Gastroenterology》 SCIE CAS 2024年第13期1801-1809,共9页
Advancements in murine modeling systems for ulcerative colitis have diversified our understanding of the pathophysiological factors involved in disease onset and progression.This has fueled the identification of molec... Advancements in murine modeling systems for ulcerative colitis have diversified our understanding of the pathophysiological factors involved in disease onset and progression.This has fueled the identification of molecular targets,resulting in a rapidly expanding therapeutic armamentarium.Subsequently,management strategies have evolved from symptomatic resolution to well-defined objective endpoints,including clinical remission,endoscopic remission and mucosal healing.While the incorporation of these assessment modalities has permitted targeted intervention in the context of a natural disease history and the prevention of complications,studies have consistently depicted discrepancies associated with ascertaining disease status through clinical and endoscopic measures.Current recommendations lack consideration of histological healing.The simultaneous achievement of clinical,endoscopic,and histologic remission has not been fully investigated.This has laid the groundwork for a novel therapeutic outcome termed disease clearance(DC).This article summarizes the concept of DC and its current evidence. 展开更多
关键词 Inflammatory bowel disease Ulcerative colitis Clinical remission Endoscopic remission Histological remission Mucosal healing Disease clearance
下载PDF
Liver as a new target organ in Alzheimer's disease:insight from cholesterol metabolism and its role in amyloid-beta clearance
2
作者 Beibei Wu Yuqing Liu +4 位作者 Hongli Li Lemei Zhu Lingfeng Zeng Zhen Zhang Weijun Peng 《Neural Regeneration Research》 SCIE CAS 2025年第3期695-714,共20页
Alzheimer's disease,the primary cause of dementia,is characterized by neuropathologies,such as amyloid plaques,synaptic and neuronal degeneration,and neurofibrillary tangles.Although amyloid plaques are the primar... Alzheimer's disease,the primary cause of dementia,is characterized by neuropathologies,such as amyloid plaques,synaptic and neuronal degeneration,and neurofibrillary tangles.Although amyloid plaques are the primary characteristic of Alzheimer's disease in the central nervous system and peripheral organs,targeting amyloid-beta clearance in the central nervous system has shown limited clinical efficacy in Alzheimer's disease treatment.Metabolic abnormalities are commonly observed in patients with Alzheimer's disease.The liver is the primary peripheral organ involved in amyloid-beta metabolism,playing a crucial role in the pathophysiology of Alzheimer's disease.Notably,impaired cholesterol metabolism in the liver may exacerbate the development of Alzheimer's disease.In this review,we explore the underlying causes of Alzheimer's disease and elucidate the role of the liver in amyloid-beta clearance and cholesterol metabolism.Furthermore,we propose that restoring normal cholesterol metabolism in the liver could represent a promising therapeutic strategy for addressing Alzheimer's disease. 展开更多
关键词 ABCA1 Alzheimer's disease AMYLOID-BETA apolipoprotein E cholesterol metabolism LIVER liver X receptor low-density lipoprotein receptor-related protein 1 peripheral clearance tauroursodeoxycholic acid
下载PDF
Traffic Incident Management Performance Measures: Ranking Agencies on Roadway Clearance Time 被引量:1
3
作者 Maroa Mumtarin Skylar Knickerbocker +1 位作者 Theresa Litteral Jonathan S. Wood 《Journal of Transportation Technologies》 2023年第3期353-368,共16页
This study develops a procedure to rank agencies based on their incident responses using roadway clearance times for crashes. This analysis is not intended to grade agencies but to assist in identifying agencies requi... This study develops a procedure to rank agencies based on their incident responses using roadway clearance times for crashes. This analysis is not intended to grade agencies but to assist in identifying agencies requiring more training or resources for incident management. Previous NCHRP reports discussed usage of different factors including incident severity, roadway characteristics, number of lanes involved and time of incident separately for estimating the performance. However, it does not tell us how to incorporate all the factors at the same time. Thus, this study aims to account for multiple factors to ensure fair comparisons. This study used 149,174 crashes from Iowa that occurred from 2018 to 2021. A Tobit regression model was used to find the effect of different variables on roadway clearance time. Variables that cannot be controlled directly by agencies such as crash severity, roadway type, weather conditions, lighting conditions, etc., were included in the analysis as it helps to reduce bias in the ranking procedure. Then clearance time of each crash is normalized into a base condition using the regression coefficients. The normalization makes the process more efficient as the effect of uncontrollable factors has already been mitigated. Finally, the agencies were ranked by their average normalized roadway clearance time. This ranking process allows agencies to track their performance of previous crashes, can be used in identifying low performing agencies that could use additional resources and training, and can be used to identify high performing agencies to recognize for their efforts and performance. 展开更多
关键词 Traffic Incident Management Roadway clearance Time Performance Measures and Ranking Agency Performance Evaluation Tobit Regression Model
下载PDF
The Risk Factors of Lymphedema in Breast Cancer Patients Post Axillary Clearance
4
作者 Fatamah Kahtani Abdulaziz Alamoudi +4 位作者 Amal Alosaimi Ayman Kurdi Ziyad Saifaddin Zaher Mikwar Galia Jadkarim 《Surgical Science》 2023年第10期658-666,共9页
Introduction: Breast cancer is the number one malignancy affecting females in Saudi Arabia with a prevalence of 22.4%. Breast cancer incidence increases annually due to the aid of established screening programs, leadi... Introduction: Breast cancer is the number one malignancy affecting females in Saudi Arabia with a prevalence of 22.4%. Breast cancer incidence increases annually due to the aid of established screening programs, leading to the discovery of breast cancer in its early stages. Surgical treatment is an integral part of early breast cancer management to achieve local control. Axillary surgical interventions such sentinel lymph node biopsy (SLNB) and axillary lymph node clearance (ALND) aim to stage the axilla as an adjunct to the management of the primary breast tumor. In this paper, we reviewed female breast cancer patients aged 30 - 60 who underwent surgical treatment of SLNB and/or ALND with reporting the prevalence of lymphedema and other associated complications and risk factors. Methodology: A cross-sectional non-interventional study, with a sample size of 250 including breast cancer cases from 2016 to 2019 at National Guard Hospital (NGH) in Jeddah, Saudi Arabia. Results: A total of 253 breast cancer cases were included in this study, with a mean age of 53 years, 52.7% were postmenopausal and positive family history was present among 21% of cases. Further, 90.9% of the cases had unilateral disease. Staging was as follows: stage I 14.5%, stage II 45.2%, stage III 37.1%, and stage IV 3.2%. Mastectomy was done in 73.4% cases and lumpectomy was performed in 34.1% of cases. In addition, 93.3% of patients had SLNB and 49% of them were positive. Axillary dissection was performed in 69.6% of our patients. Radiotherapy and chemotherapy were given to 71.8% and 80.4% of cases respectively. Among the chemotherapy (chemo) recipients, 40.2% received adjuvant chemo, 54.5% received neoadjuvant chemo, and the remaining 5.3% received both. Further, the most prevalent complication was pain accounting for 42.1% of total complications, and the least prevalent was cellulitis 4%. Also, seroma developed in 18.3% cases, paresthesia noted in 5.6% of cases, winged scapula was reported as 2%, weakness and necrosis were seen in 6% and 13.1% of cases respectively. Axillary vein thrombosis and lymphangiosarcoma were reported in none of the patients (0%). Lymphoedema accounted for 16.1% of overall complications, 85% of the patients who developed lymphedema had undergone ALND, and 12.9% and 14.4% received radiotherapy and chemotherapy respectively. Lymphedema was observed in breast cancer stages as follows: stage I 1.2%, stage II 7.2%, and stage III 5.2%. Patients with body mass index (BMI) of 30 - 39 kg/m<sup>2</sup> had 7.2% prevalence of lymphedema compared to other BMI groups. Overall mortality was 8.3%. Conclusion: The findings of our study suggest that the prevalence of lymphedema was higher in ALND patients with locally advanced tumors, and higher BMI, compared to patients with stage I breast cancer and low BMI. Further, the prevalence of lymphedema in patients who underwent ALND was significantly lower than those who were treated by lumpectomy 10.3% (p-value = 0.034) in comparison to mastectomy 19.3%. 展开更多
关键词 LYMPHEDEMA Breast Cancer Axillary Lymph Node clearance Axillary Lymph Node Dissection Sentinel Lymph Node Biopsy MASTECTOMY LUMPECTOMY
下载PDF
Experimental Study of the Motion Modes of a Planar Mechanical System with Multi-Clearance Revolute Joints
5
作者 Kifatsoa Kolani Mutuku Muvengei +1 位作者 Joshua Ngoret James Kimotho 《Open Journal of Applied Sciences》 2023年第11期2014-2031,共18页
Clearances in joints of a mechanical multibody system can induce impulsive forces, leading to vibrations that compromise the system’s reliability, stability, and lifespan. Through dynamic analysis, designers can inve... Clearances in joints of a mechanical multibody system can induce impulsive forces, leading to vibrations that compromise the system’s reliability, stability, and lifespan. Through dynamic analysis, designers can investigate the effects of the clearances on the dynamics of the multibody system. A revolute joint with clearance exhibits three motions which are;free-flight, impact and continuous contact motion modes. Therefore, a multibody system with n-number of revolute clearance joints will exhibit 3n motion modes which are a combination of the three motions in each joint. This study investigates experimentally the nine motion modes in a mechanical system with two revolute clearance joints. A slider crank mechanism has been used as the demonstrative example. We observed that the experimental curve exhibits a greater impact compared to the simulation curve. In conclusion, this experimental investigation offers valuable insights into the dynamics of planar mechanical systems with multiple clearance revolute joints. Utilizing a slider-crank mechanism for data acquisition, the study successfully confirmed seven out of nine motion modes previously identified in numerical research. The missing modes are attributed to inherent complexities in real-world systems, such as journal-bearing misalignment. 展开更多
关键词 Slider Crank Mechanism Dynamic Responses Revolute clearance Joints Motion Modes
下载PDF
Predictive Value of Serum pgRNA on HBeAg Clearance in Patients with Chronic Hepatitis B with Low HBeAg Levels Treated with Pegylated Interferon
6
作者 Yu Li Yifei Lyu +1 位作者 Feng-Yu Xi Ying Gao 《Journal of Clinical and Nursing Research》 2023年第4期165-169,共5页
Objective:To study the predictive value of serum pregenomic RNA(pgRNA)on HBeAg clearance in patients with chronic hepatitis B with low HBeAg levels during pegylated interferon therapy.Methods:Twenty chronic hepatitis ... Objective:To study the predictive value of serum pregenomic RNA(pgRNA)on HBeAg clearance in patients with chronic hepatitis B with low HBeAg levels during pegylated interferon therapy.Methods:Twenty chronic hepatitis B patients with HBeAg positive and quantitative<50S/CO were selected for this study.The subjects underwent pegylated interferon therapy for 48-96 weeks and were followed up in the outpatient clinic after treatment.The patients were then divided into groups based on whether their HbeAg turned negative.The predictive ability of each indicator for HBeAg negative conversion was evaluated in the HBeAg negative group and the HBeAg positive group.Results:The results of logistic regression analysis suggested that pgRNA and HBcrAg were better indicators for predicting the clearance of HBeAg after treatment.Conclusion:For patients with chronic hepatitis B with low HBeAg levels,pgRNA is a good indicator in predicting HBeAg clearance during pegylated interferon therapy. 展开更多
关键词 Serum pgRNA Pegylated interferon Low HBeAg level Chronic hepatitis B HBeAg clearance Predictive value
下载PDF
Tip Clearance Flows in Turbine Cascades 被引量:5
7
作者 李伟 乔渭阳 孙大伟 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2008年第3期193-199,共7页
This article describes the effects of some factors on the tip clearance flow in axial linear turbine cascades. The measurements of the total pressure loss coefficient are made at the cascade outlets by using a five-ho... This article describes the effects of some factors on the tip clearance flow in axial linear turbine cascades. The measurements of the total pressure loss coefficient are made at the cascade outlets by using a five-hole probe at exit Mach numbers of 0.10, 0.14 and 0.19. At each exit Mach number, experiments are performed at the tip clearance heights of 1.0%, 1.5%, 2.0%, 2.5% and 3.0% of the blade height. The effects of the non-uniform tip clearance height of each blade in the pitchwise direction are also studied. The results show that at a given tip clearance height, generally, total pressure loss rises with exit Mach numbers proportionally. At a fixed exit Mach number, the total pressure loss augments nearly proportionally as the tip clearance height increases. The increased tip clearance heights in the tip regions of two adjacent blades are to be blame for the larger clearance loss of the center blade. Compared to the effects of the tip clearance height, the effects of the exit Mach number and the pitchwise variation of the tip clearance height on the cascade total pressure loss are so less significant to be omitted. 展开更多
关键词 tip clearance flow turbine cascade tip clearance height total pressure loss coefficient
下载PDF
An Error Equivalent Model of Revolute Joints with Clearances for Antenna Pointing Mechanisms 被引量:5
8
作者 Quan Liu Sheng-Nan Lu Xi-Lun Ding 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2018年第2期97-105,共9页
Joint clearances in antenna pointing mechanisms lead to uncertainty in function deviation. Current studies mainly focus on radial clearance of revolute joints, while axial clearance has rarely been taken into consider... Joint clearances in antenna pointing mechanisms lead to uncertainty in function deviation. Current studies mainly focus on radial clearance of revolute joints, while axial clearance has rarely been taken into consideration. In fact, own?ing to errors from machining and assembly, thermal deformation and so forth, practically, axial clearance is inevitable in the joint. In this study, an error equivalent model(EEM) of revolute joints is proposed with considering both radial and axial clearances. Compared to the planar model of revolute joints only considering radial clearance, the journal motion inside the bearing is more abundant and matches the reality better in the EEM. The model is also extended for analyzing the error distribution of a spatial dual?axis("X–Y" type) antenna pointing mechanism of Spot?beam antennas which especially demand a high pointing accuracy. Three case studies are performed which illustrates the internal relation between radial clearance and axial clearance. It is found that when the axial clearance is big enough, the physical journal can freely realize both translational motion and rotational motion. While if the axial clearance is limited, the motion of the physical journal will be restricted. Analysis results indicate that the consideration of both radial and axial clearances in the revolute joint describes the journal motion inside the bearing more precise. To further validate the proposed model, a model of the EEM is designed and fabricated. Some suggestions on the design of revolute joints are also provided. 展开更多
关键词 Error modeling Joint clearances Antenna pointing mechanism Radial clearance Axial clearance
下载PDF
Clearance Influence on Dynamic Response of Intermittent Roller Chain Drive 被引量:11
9
作者 XU Lixin YANG Yuhu +2 位作者 CHANG Zongyu SHEN Zhaoguang LIU Jianping 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2010年第6期699-708,共10页
The clearances appear in chain link hinges induced by manufacturing tolerance or wear of components are the most important factor that influences the dynamic performance of the intermittent roller chain drives. Due to... The clearances appear in chain link hinges induced by manufacturing tolerance or wear of components are the most important factor that influences the dynamic performance of the intermittent roller chain drives. Due to the existence of the clearances in chain link hinges, the serious impact vibration phenomenon which influences the stability and the position accuracy of the chain drive system would be caused in the intermittent motion. But, the problem may be that a reasonable modeling on the chain with clearances is difficult due to the large clearance's number in chain system and the fact that the clearance' size are different. Currently, the studies on the dynamics of the intermittent roller chain considering the multi-clearance' joints are rare. Most research works have only focused on the constant moving chains. Taking the intermittent roller chain system as an object, this paper designs and builds the experimental device of this kind of mechanical system. The Longitudinal vibration response of the intermittent chain under the different motion laws was tested. The experimental study shows that the clearances presented in chain link hinges can cause severe impact vibration in the intermittent motion of chain. In subsequent work, the dynamic model of the intermittent roller chain system with the multi-clearance' joints was established. By calculating the dynamic response of this kind of mechanical system under the different motion laws, the effect of the clearances on the dynamic response of the intermittent chain drive system was analyzed. The theoretical simulation shows that the serious impact vibration phenomenon of the chain system can be caused by the clearances at the start accelerating period, and the chain drive system is often accompanied by the severe shock and vibration at the moment that the chain moves from the acceleration period to deceleration period. The research conclusions made by the experimental and theoretical studies indicate that the use of motion laws with small and continuous jerk at conversion point can effectively suppress the impact vibration at this point caused by clearances' effect. Additionally, the use of nonsymmetrical motion laws with small jerk approaching the end of the indexing period can obtain a smaller residual vibration. The presented motion law can provide an important reference for the improvement of the dynamic performance of the intermittent chain drive systems. 展开更多
关键词 roller chain clearance intermittent motion motion law
下载PDF
Effects of Semi-floating Ring Bearing Outer Clearance on the Subsynchronous Oscillation of Turbocharger Rotor 被引量:10
10
作者 LIANG Feng ZHOU Ming XU Quanyong 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2016年第5期901-910,共10页
Semi-floating ring bearing(SFRB) is developed to control the vibration of turbocharger rotor. The outer clearance of SFRB affects the magnitude and frequency of nonlinear whirl motion, which is significant for the d... Semi-floating ring bearing(SFRB) is developed to control the vibration of turbocharger rotor. The outer clearance of SFRB affects the magnitude and frequency of nonlinear whirl motion, which is significant for the design of turbocharger. In order to explore the effects of outer clearance, a transient finite element analysis program for rotor and oil film bearing is built and validated by a published experimental case. The nonlinear dynamic behaviors ofrotor-SFRB system are simulated. According to the simulation results, two representative subsynchronous oscillations excited by the two hearings respectively are discovered. As the outer clearance of SFRB increases from 24 ~tm to 60 pro, the low-frequency subsynchronous oscillation experiences three steps, including a strong start, a gradual recession and a combination with the other one. At the same time, the high-frequency subsynchronous oscillation starts to appear gradually, then strengthens, and finally combines. If gravity and unbalance are neglected, the combination will start starts from high rotor speed and extents to low rotor speed, just like a "zipper". It is found from the quantitative analysis that when the outer clearance increases, the vibration amplitude experiences large value firstly, then reduction, and suddenly increasing after combination. A useful design principle of SFRB outer clearance for minimum vibration amplitude is proposed: the outer clearance value should be chosen to keep the frequency of two subsynchronous oscillations clearly separated and their amplitudes close. 展开更多
关键词 subsynchronous oscillation outer clearance Semi-floating ring bearing ROTORDYNAMICS TURBOCHARGER
下载PDF
Effects of Floating Ring Bearing Manufacturing Tolerance Clearances on the Dynamic Characteristics for Turbocharger 被引量:16
11
作者 WANG Longkai BIN Guangfu +1 位作者 LI Xuejun ZHANG Xuefeng 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2015年第3期530-540,共11页
The inner and outer oil film dynamic characteristic coefficients of floating ring bearings(FRBs) change due to the manufacturing tolerance of the floating ring, journal and intermediate, which leads to high-speed tu... The inner and outer oil film dynamic characteristic coefficients of floating ring bearings(FRBs) change due to the manufacturing tolerance of the floating ring, journal and intermediate, which leads to high-speed turbocharger's vibration too large and even causes nonlinear vibration accident. However, the investigation of floating ring bearing manufacturing tolerance clearance on the rotordynamic characteristics is less at present. In order to study the influence law of inner and outer clearance on turbocharger vibration, the rotor dynamic motion equations of turbocharger supported in FRBs are derived by analyzing the size relations between floating ring, journal and intermediate for the inner and outer oil film clearances, the time transient response analysis for combination of FRBs clearance are developed. A realistic turbocharger is taken as a research object, the FE model of the turbocharger with FRBs is modeled. Under the conditions of four kinds of limit state bearing clearances for inner and outer oil film, the nonlinear transient analyses are performed based on the established FE dynamic models of the nonlinear rotor-FRBs system applied incentive combinations of gravity and unbalance force, respectively. From the waterfall, the simulation results show that the speed for the appearance of fractional frequency is not identical and the amplitude magnitude is different under the four kinds of bearing manufacturing tolerance limit clearances, and fractional frequency does not appear in the turbocharger and the amplitude is minimum under the ODMin/IDMax bearing manufacturing tolerance clearances. The turbocharger vibration is reduced by controlling the manufacturing tolerance clearance combinations of FRBs, which is helpful for the dynamic design and production-manufacturing of high-speed turbocharger. 展开更多
关键词 TURBOCHARGER floating ring bearing manufacturing tolerance clearance nonlinear transient analysis dynamic characteristics
下载PDF
Numerical Analysis of Nozzle Clearance's Effect on Turbine Performance 被引量:18
12
作者 HU Liangjun YANG Ce +2 位作者 SUN Harold ZHANG Jizhong LAI Mingchia 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2011年第4期618-625,共8页
Variable nozzle turbine (VNT) has become a popular variable geometry turbine (VGT) technology for the diesel engine application. Nozzle clearance, which can't be avoided on the hub and shroud side of the VNT turb... Variable nozzle turbine (VNT) has become a popular variable geometry turbine (VGT) technology for the diesel engine application. Nozzle clearance, which can't be avoided on the hub and shroud side of the VNT turbine due to the pivoting stators, can lead to turbine performance deterioration. However, its mechanism is still not clear. In this paper, numerical investigation, which is validated by experiment, is carried out to study the mechanism of the nozzle clearance's effect on the turbine performance. Firstly, performance of the mixed flow turbine with fixed nozzle clearances tested on flow bench. Performance of the tested turbine with the same nozzle clearance is numerically simulated. The numerical result agrees well with the test data, which proves correct of the numerical method. Then the turbine performance with different nozzle clearances is numerically analyzed. The research showed that with nozzle clearance, flow loss in the nozzle increases at first and it reaches the maximum value when the clearance ratio is 5%. Flow at the exit of the nozzle becomes less uniform with nozzle clearance. The negative incidence angle of the rotor also increases with nozzle clearance and leads to more incidence angle loss in the rotor. The low energy fluid formed in the nozzle due to the nozzle clearance migrates from hub to shroud side in the rotor, which is another main reason for the rotor's performance degradation. The present research exposed the mechanism of the dramatically decrease of the turbine performance with nozzle clearance: (a) The loss associated with the nozzle leakage increases with the nozzle clearance; (b) The flow loss grows up quickly in the rotor due to the incidence angle loss and migration of the low energy fluid from hub to shroud side. 展开更多
关键词 nozzle clearance variable nozzle turbine (VNT) mixed flow turbine
下载PDF
EFFECT OF TIP CLEARANCE ON PERFORMANCE AND FLOW FIELD OF SMALL SIZED HIGH SPEED CENTRIFUGAL FAN 被引量:2
13
作者 曹人靖 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2005年第4期329-334,共6页
A centrifugal fan with the high speed and compact dimensions is studied numerically and experimentally. The centrifugal fan consists of a shrouded impeller rotating at 34 000 r/min with a small tip clearance 0.7 mm to... A centrifugal fan with the high speed and compact dimensions is studied numerically and experimentally. The centrifugal fan consists of a shrouded impeller rotating at 34 000 r/min with a small tip clearance 0.7 mm to the fixed outer casing. Computational models with/without the tip clearance are built and the κ-ω shear stress transport (SST) turbulence model and the unstructured mesh are applied to the numerical simulation for unsteady solutions. The overall performance is measured on a standard experimental bench and the major flow feature of each component inside the centrifugal fan is numerically investigated. In the presence of the tip clearance due to the difference of static pressure between leading and trailing edges of the clearance, i. e. , leading and trailing edges of the impeller, a strong return flow exists inside the clearance passage and re-circulates the main stream inside the impeller passage, and produces the strong flow interaction, thus changing the flow field and influencing the overall performance. 展开更多
关键词 small sized high speed centrifugal fan tip clearance flow field analysis
下载PDF
Indocyanine green clearance test combined with MELD score in predicting the short-term prognosis of patients with acute liver failure 被引量:27
14
作者 Hong-Ling Feng Qian Li +2 位作者 Lin Wang Gui-Yu Yuan Wu-Kui Cao 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS 2014年第3期271-275,共5页
BACKGROUND: Acute liver failure(ALF) is an acute severe deterioration of liver function with high mortality. Early and accurate prognostic assessment of patients with ALF is critically important. Although the model fo... BACKGROUND: Acute liver failure(ALF) is an acute severe deterioration of liver function with high mortality. Early and accurate prognostic assessment of patients with ALF is critically important. Although the model for end-stage liver disease(MELD) scores and King’s College Hospital(KCH) criteria are well-accepted as predictive tools, their accuracy is unsatisfactory.The indocyanine green(ICG) clearance test(ICGR15, ICG retention rate at the 15 minutes) is a sensitive indicator of liver function. In this study, we investigated the efficacy of the ICGR15 for the short-term prognosis in patients with ALF. We compared the predictive value of ICGR15 with the MELD scores and KCH criteria.METHODS: Sixty-nine patients who had been diagnosed with ALF were recruited retrospectively. ICGR15 had been performed by ICG pulse spectrophotometry and relevant clinical and laboratory indices were analyzed within 24 hours of diagnosis.In addition, the MELD scores and KCH criteria were calculated.RESULTS: The three-month mortality of all patients was 47.83%.Age, serum total bilirubin and creatinine concentrations,international normalized ratio for prothrombin time, ICGR15,MELD scores and KCH criteria differed significantly between surviving and deceased patients. A positive correlation was observed between ICGR15 and MELD scores(r=0.328, P=0.006).The ICGR15-MELD model, Logit(P)=0.096×ICGR15+0.174 ×MELD score–9.346, was constructed by logistic regression analysis. The area under the receiver operating characteristic curve was 0.855. When set the cut-off point to-0.4684, the sensitivity was 87.90% and specificity, 72.20%. The area under the receiver operating characteristic curve of the ICGR15-MELD model(0.855) was significantly higher than that of the ICGR15(0.793), MELD scores(0.776) and KCH criteria(0.659).Based on this cut-off value, the patients were divided into two groups. The mortality was 74.36% in the first group(ICGR15-MELD≥-0.4686) and 13.33% in the second group(ICGR15-MELD<-0.4686), with a significant difference between the two groups(χ2=25.307, P=0.000).CONCLUSION: The ICGR15-MELD model is superior to the ICGR15, MELD scores, and KCH criteria in predicting the shortterm prognosis of patients with ALF. 展开更多
关键词 acute liver failure indocyanine green clearance test model for end-stage liver disease PROGNOSIS
下载PDF
Combined APACH Ⅱ score and arterial blood lactate clearance rate to predict the prognosis of ARDS patients 被引量:21
15
作者 Wen-Hui Wu Yuan-Yuan Niu +4 位作者 Chang-Ran Zhang Long-Bin Xiao Hui-Shao Ye De-Mao Pan Mian Zeng 《Asian Pacific Journal of Tropical Medicine》 SCIE CAS 2012年第8期656-660,共5页
Objective:To explore the easily applicable indicators of practical value to evaluate the prognosis of acute respiratory distress syndrome(ARDS).Methods:Blood and biochemical tests and bloodgas analyses were performe... Objective:To explore the easily applicable indicators of practical value to evaluate the prognosis of acute respiratory distress syndrome(ARDS).Methods:Blood and biochemical tests and bloodgas analyses were performed upon entry into the ICUs,12 h,24 h,48 h and 72 h after that in 72 ARDS patients(who were admitted to the ICUs of our hospital from January 2000 to December 2009).Then APACHEⅡscores were achieved by combining relevant physiological parameters and laboratory results.Results:There was a statistical difference between the death group and survival group at different time points upon entering the ICUs in terms of APACHEⅡscore, alveolar-arterial oxygen difference and arterial blood lactate clearance rate.PaO<sub>2</sub>/FiO<sub>2</sub> values were recorded to be statistically different between the death group and survival group 24 h,48 h and 72 h,respectively after entry into the ICUs.In addition,registered linear regression existed between APACHEⅡscore,alveolar-arterial oxygen difference or PaO<sub>2</sub>/FiO<sub>2</sub> value and time. APACHEⅡscore 24 h and 72 h after entering ICUs predicted mortality with an area under the ROC curve(AUC) standing respectively at 0.919 and 0.9SS.Arterial blood lactate clearance rate 12 h, 24 h,48 h and 72 h after entering ICUs predicted mortality with an area under the ROC curve (AUC) at 0.918,0.918,0.909 and 0.991,respectively.Conclusions:APACHEⅡscore applied in combination with arterial blood lactate clearance rate is of clinical significance in assessing the prognosis of ARDS patients. 展开更多
关键词 Acute respiratory distress syndrome APACHE Ⅱscore Arterial blood LACTATE clearance rate PaO2/FiO2 value Alveolar-arterial oxygen difference
下载PDF
Indocyanine green clearance in evaluating the recovery of liver reserve function after superselective transarterial chemoembolization 被引量:9
16
作者 Xin Chen Hai-Bing Zhang +4 位作者 Zhong-Qi Li Xiong-Fei Yu Mei-Fang Yang Hao-Hao Wang Li-Song Teng 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS 2013年第6期656-660,共5页
Transarterial chemoembolization(TACE)may ravage normal liver tissues apart from the neoplastic nodules which offset the anti-tumor effect.This study aimed to evaluate the recovery of liver reserve function(LRF)after T... Transarterial chemoembolization(TACE)may ravage normal liver tissues apart from the neoplastic nodules which offset the anti-tumor effect.This study aimed to evaluate the recovery of liver reserve function(LRF)after TACE by indocyanine green(ICG)clearance test and other routine liver function tests.Forty-six newly diagnosed HCC patients who had undergone TACE as the initial treatment from January 2011 to January 2012 were enrolled in this study.The effects of age,basic ICG clearance rate and interval time between two assessments on the recovery of LRF were analyzed.We found that ICG retention rate at the 15 minutes(ICGR15)was significantly increased after TACE(12.3±8.1%vs 16.8±12.1%,P【0.01)in all the 46 patients.In particular,the ICGR15 value was increased in older patients(age】55 years,20.3±12.5%vs 13.7±7.2%,P【0.01).The interval of ICG test also affected the ICGR15 value(≤47days,17.8±11.4%after vs 12.1±7.1%before TACE,P【0.01).Our data suggested that TACE decreased LRF,especially in older patients.ICG test was more sensitive to evaluate the recovery of LRF after TACE than the Child-Pugh grade and routine liver function tests. 展开更多
关键词 hepatocellular carcinoma transarterial chemoembolization liver reserve function indocyanine green clearance
下载PDF
COMPARISON OF TWO METHODS TO INCREASE TIP CLEARANCE AND ITS EFFECT ON PERFORMANCE OF TURBOCHARGER CENTRIFUGAL COMPRESSOR STAGE 被引量:5
17
作者 SYED Noman Danish 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2007年第4期60-65,共6页
Tip clearance between the blade tip and casing of a centrifugal compressor can be varied through two methods: by changing the blade height (MI) or by changing the casing diameter (M2). Numerical simulations are c... Tip clearance between the blade tip and casing of a centrifugal compressor can be varied through two methods: by changing the blade height (MI) or by changing the casing diameter (M2). Numerical simulations are carried out to compare these two methods and their effect on the stage and impeller performance. The impeller and diffuser are connected through rotor stator boundary using frozen rotor approach. Overall stage performance and the flow configuration have been investigated for nine tip clearance levels from no gap to 1 mm. Impeller and diffuser performances are also presented separately. It has been found that the overall and impeller performance are comparatively better for MI below tip clearance of 0.5 mm whereas M2 is found advantageous above 0.5 mm of tip clearance. Both MI and M2 show performance degradation with the increase in tip clearance. Two models have been proposed for the stage total pressure ratio and efficiency, which are found to be in agreement with experimental results. The impeller efficiency and the pressure ratio are found to be maximum at tip clearance of 0.1 mm for both the cases however minimum diffuser effectiveness is also observed at the same clearance level. Diffuser effectiveness is found to be maximum at zero gap for both cases. As it is practically impossible to have zero gap for unshrouded impellers so it is concluded that the optimum thickness is 0.5 mm onwards for MI and 0.5 mm for M2 in terms of diffuser effectiveness. Mass averaged flow parameters, entropy, blade loading diagram and relative pressure fields are presented, showing the loss production within the impeller passage with tip clearance. 展开更多
关键词 Centrifugal impeller Diffuser Stage Tip clearance Numerical simulation Entropy
下载PDF
HBsAg clearance by Peg-interferon addition to a long-term nucleos(t)ide analogues therapy 被引量:5
18
作者 Michele Barone Andrea Iannone Alfredo Di Leo 《World Journal of Gastroenterology》 SCIE CAS 2014年第26期8722-8725,共4页
The ideal endpoint of hepatitis B virus(HBV)antiviral therapy is HBsAg loss,a difficult goal to obtain,especially in HBeAg negative patients.Herein,we report the results obtained by the addition of peg-interferonα-2a... The ideal endpoint of hepatitis B virus(HBV)antiviral therapy is HBsAg loss,a difficult goal to obtain,especially in HBeAg negative patients.Herein,we report the results obtained by the addition of peg-interferonα-2a to a long-lasting nucleos(t)ide analogues therapy in a HBeAg negative,genotype D patient with steadily HBV-DNA negative/HBsAg positive values.In 2002,our Caucasian 44-year-old male patient received lamivudine and,4 years later,added adefovir because of a virological breakthrough.In 2011,considering his young age,liver stiffness(4.3 kPa)and HBsAg levels(3533IU/mL),we added Peg-interferonα-2a for six months(3in combination with nucleos(t)ide analogues followed by 3 mo of Peg-interferonα-2a monotherapy).A decrease of HBsAg levels was observed after 1 mo(1.21log)of Peg-interferon and 3 mo(1.88 log)after the discontinuation of all drugs.Later,a complete clearance of HBsAg was obtained with steadily undetectable HBVDNA serum levels(<9 IU/mL).HBsAg clearance by the addition of a short course of Peg-interferonα-2a represents an important result with clinical and pharmacoeconomic implications,considering that nucleos(t)ide analogues therapy in HBeAg negative chronic hepatitis B patients is considered a long-lasting/life-long treatment. 展开更多
关键词 ADDITION HBeAg negative HBsAg clearance Nucleos(t)ide analogues PEG-INTERFERON
下载PDF
Topology and Vortex Structures of Turbine Cascade with Different Tip Clearances 被引量:5
19
作者 韩万金 杨庆海 +1 位作者 黄洪雁 贾琳 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2002年第1期18-26,共9页
This paper uses the topology theory to analyze the surface flowspectrums of straight, positively curved and negatively curvedcascades with relative tip clearances of 0.023 and 0.036, findsapparent differences of topol... This paper uses the topology theory to analyze the surface flowspectrums of straight, positively curved and negatively curvedcascades with relative tip clearances of 0.023 and 0.036, findsapparent differences of topology and vortex structures in the bladetip and the suction side wall corner of single type of cascade withthis two clearances, and studies the mechanism of the differenceformation as well as their effects o the energy loss. 展开更多
关键词 turbine cascade blade tip clearance flow visualization topology andvortex structures
下载PDF
Early lactate clearance as a reliable predictor of initial poor graft function after orthotopic liver transplantation 被引量:7
20
作者 Jian-Feng Wu,Rong-Yao Wu,Juan Chen,Bin Ou-Yang,Min-Ying Chen and Xiang-Dong Guan Department of Surgical Intensive Care Unit,First Affiliated Hospital,Sun Yat-Sen University,Guangzhou 510080,China 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS 2011年第6期587-592,共6页
BACKGROUND:Initial poor graft function (IPGF) following orthotopic liver transplantation is a major determinant of postoperative survival and morbidity.Lactate clearance is a good marker of liver function.In this stud... BACKGROUND:Initial poor graft function (IPGF) following orthotopic liver transplantation is a major determinant of postoperative survival and morbidity.Lactate clearance is a good marker of liver function.In this study,we investigated the clinical utility of early lactate clearance as an early and accurate predictor for IPGF following liver transplantation.METHODS:This was a prospective observational study of 222 patients referred to the surgical intensive care unit (SICU) after orthotopic liver transplantation.The IPGF group consisted of patients with alanine aminotransferase (ALT) and/or aspartate aminotransferase (AST) >1500 IU/L within 72 hours after orthotopic liver transplantation.Early lactate clearance was defined as lactate at SICU presentation (hour 0) minus lactate at hour 6,divided by lactate at SICU presentation.The model for end-stage liver disease (MELD) score,Child-Pugh score and laboratory data including AST,ALT,total bilirubin (TB) and prothrombin time (PT) were recorded at SICU presentation and compared between the non-IPGF and IPGF groups Receiver operating characteristic (ROC) curves were plotted to measure the performance of early lactate clearance,MELD score,Child-Pugh score,TB and PT.RESULTS:IPGF occurred in 45 of the 222 patients (20.3%).The early lactate clearance in the non-IPGF group was markedly higher than that in the IPGF group (43.2±13.8% vs 13.4±13.7% P<0.001).The optimum cut-off value for early lactate clearance predicting IPGF was 24.8% (sensitivity 95.5%,specificity 88.9%).The area under the curve of the ROC was 0.961,which was significantly superior to MELD score,Child-Pugh score TB and PT.Patients with early lactate clearance ≤24.8% had a higher IPGF rate (OR=169) and a higher risk of in-hospital mortality (OR=3.625).CONCLUSIONS:Early lactate clearance can serve as a prompt and accurate bedside predictor of IPGF.Patients with early lactate clearance less than 24.8% are associated with a higher incidence of IPGF. 展开更多
关键词 early lactate clearance initial poor graft function liver transplantation
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部