Comparison of ocular biometric parameters between two swept-source optical coherence tomography devices and Scheimpflug tomography in patients with cataract
1
作者 Shan Ma Cheng Li +6 位作者 Jing Sun Jun Yang Kai Wen Xi-Teng Chen Fang-Yu Zhao Rong-Yu Gao Fang Tian 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第8期1437-1446,共10页
AIM:To assess and compare the variations and agreements across different ocular biometric parameters using swept-source optical coherence tomography(SS-OCT)and Scheimpflug tomography in patients diagnosed with catarac... AIM:To assess and compare the variations and agreements across different ocular biometric parameters using swept-source optical coherence tomography(SS-OCT)and Scheimpflug tomography in patients diagnosed with cataract.METHODS:This prospective case series was conducted at Tianjin Medical University Eye Hospital.In total,212 eyes from 212 patients scheduled for phacoemulsification were included.Eyes were evaluated preoperatively using two SSOCT devices(IOLMaster700 and CASIA2)and Scheimpflug tomography(Pentacam).Central corneal thickness(CCT),anterior chamber depth(ACD),aqueous depth(AQD),white-to-white distance(WTW),flat simulated keratometry(Kf),steep simulated keratometry(Ks),mean keratometry(Km),and total corneal keratometry(TKm)were measured.Intraclass correlation coefficient(ICC),95%confidence intervals(CI)and limits of agreement(LoA)widths were conducted to assess differences and correlations between devices.RESULTS:All parameters,except for Ks,were significantly different.Pairwise comparison revealed no significant differences between keratometry obtained by IOLMaster 700 and Pentacam.LoA widths of all paired comparisons for Ks were>0.80 D.Except for WTW between IOLMaster 700 and CASIA2 and between CASIA2 and Pentacam,other Pearson’s coefficients between devices showed a strong correlation(all r>0.95).The ICC of WTW(ICC=0.438,95%CI 0.167-0.625)showed poor reliability.The reliability of CCT,ACD,and AQD was excellent(all ICC>0.95),whereas that of TKm was good(ICC=0.827,95%CI 0.221-0.939).A significant linear correlation was also observed among devices.CONCLUSION:The ocular parameters derived from the use of IOLMaster700,CASIA2,and Pentacam exhibit significant discrepancies;as such,measurements from these devices should not be deemed as interchangeable. 展开更多
关键词 ocular parameters swept-source optical coherence tomography CATARACT
原文传递
Digital measuring the ocular morphological parameters of guinea pig eye in vivo with Python
2
作者 Yue Di Zhong-Bao Qiao +4 位作者 Hai-Yun Ye Xin-Yue Li Wen-Ting Luo Wang-Yi Fang Tong Qiao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期239-246,共8页
AIM:To quantitatively measure ocular morphological parameters of guinea pig with Python technology.METHODS:Thirty-six eyeballs of eighteen 3-weekold guinea pigs were measured with keratometer and photographed to obtai... AIM:To quantitatively measure ocular morphological parameters of guinea pig with Python technology.METHODS:Thirty-six eyeballs of eighteen 3-weekold guinea pigs were measured with keratometer and photographed to obtain the horizontal,coronal,and sagittal planes respectively.The corresponding photo pixels-actual length ratio was acquired by a proportional scale.The edge coordinates were identified artificially by ginput function.Circle and conic curve fitting were applied to fit the contour of the eyeball in the sagittal,coronal and horizontal view.The curvature,curvature radius,eccentricity,tilt angle,corneal diameter,and binocular separation angle were calculated according to the geometric principles.Next,the eyeballs were removed,canny edge detection was applied to identify the contour of eyeball in vitro.The results were compared between in vivo and in vitro.RESULTS:Regarding the corneal curvature and curvature radius on the horizontal and sagittal planes,no significant differences were observed among results in vivo,in vitro,and the keratometer.The horizontal and vertical binocular separation angles were 130.6°±6.39°and 129.8°±9.58°respectively.For the corneal curvature radius and eccentricity in vivo,significant differences were observed between horizontal and vertical planes.CONCLUSION:The Graphical interface window of Python makes up the deficiency of edge detection,which requires too much definition in Matlab.There are significant differences between guinea pig and human beings,such as exotropic eye position,oblique oval eyeball,and obvious discrepancy of binoculus.This study helps evaluate objectively the ocular morphological parameters of small experimental animals in emmetropization research. 展开更多
关键词 ocular morphological parameters guinea pig digital measurement PYTHON
原文传递
Ocular biometric characteristics of Han ethnicity in Tianjin and Uyghur ethnicity in Xinjiang undergoing cataract surgery
3
作者 Zhao Xu Li-Ming Wang +7 位作者 Qiang Feng Dan-Dan Zhang Ayiguzaili Tuerdimaimaiti Ru-Ru Guo Jing Sun Li-Jie Dong Rui-Hua Wei Ai-Hua Liu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第6期1058-1065,共8页
AIM:To analyze and compare the differences among ocular biometric parameters in Han and Uyghur populations undergoing cataract surgery.METHODS:In this hospital-based prospective study,410 patients undergoing cataract ... AIM:To analyze and compare the differences among ocular biometric parameters in Han and Uyghur populations undergoing cataract surgery.METHODS:In this hospital-based prospective study,410 patients undergoing cataract surgery(226 Han patients in Tianjin and 184 Uyghur patients in Xinjiang)were enrolled.The differences in axial length(AL),anterior chamber depth(ACD),keratometry[steep K(Ks)and flat K(Kf)],and corneal astigmatism(CA)measured using IOL Master 700 were compared between Han and Uyghur patients.RESULTS:The average age of Han patients was higher than that of Uyghur patients(70.22±8.54 vs 63.04±9.56y,P<0.001).After adjusting for age factors,Han patients had longer AL(23.51±1.05 vs 22.86±0.92 mm,P<0.001),deeper ACD(3.06±0.44 vs 2.97±0.37 mm,P=0.001),greater Kf(43.95±1.40 vs 43.42±1.69 D,P=0.001),steeper Ks(45.00±1.47 vs 44.26±1.71 D,P=0.001),and higher CA(1.04±0.68 vs 0.79±0.65,P=0.025)than Uyghur patients.Intra-ethnic male patients had longer AL,deeper ACD,and lower keratometry than female patients;however,CA between the sexes was almost similar.In the correlation analysis,we observed a positive correlation between AL and ACD in patients of both ethnicities(rHan=0.48,rUyghur=0.44,P<0.001),while AL was negatively correlated with Kf(rHan=-0.42,rUyghur=-0.64,P<0.001)and Ks(rHan=-0.38,rUyghur=-0.66,P<0.001).Additionally,Kf was positively correlated with Ks(rHan=0.89,rUyghur=0.93,P<0.001).CONCLUSION:There are differences in ocular biometric parameters between individuals of Han ethnicity in Tianjin and those of Uyghur ethnicity in Xinjiang undergoing cataract surgery.These ethnic variances can enhance our understanding of ocular diseases related to these parameters and provide guidance for surgical procedures. 展开更多
关键词 ocular biometric parameters IOL Master 700 ethnic difference
原文传递
Effects of diode laser photocoagulation treatment on ocular biometric parameters in premature infants with retinopathy of prematurity 被引量:2
4
作者 Damla Erginturk Acar Ugur Acar +2 位作者 Zuhal Ozen Tunay Aysegul Arman Anil Barak 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第2期277-282,共6页
AIM:To investigate the effects of diode laser treatment on ocular biometric parameters in premature infants with retinopathy of prematurity(ROP).METHODS:Premature infants who received diode laser treatment for ROP(n=6... AIM:To investigate the effects of diode laser treatment on ocular biometric parameters in premature infants with retinopathy of prematurity(ROP).METHODS:Premature infants who received diode laser treatment for ROP(n=68)and premature infants with spontaneous regressed ROP without treatment(n=50)were performed longitudinal ocular biometric measurements including anterior chamber depth,lens thickness and axial length as follows:1 d prior to laser treatment,and 3,6,9,and 12 mo after the laser treatment.RESULTS:The mean birth weight,gestational age and initial examination time values were 936.53±302.07 g,26.66±2.42 wk,36.26±2.73 wk in the treatment group and 959.78±260.08 g,27.28±2.10 wk,36.56±2.54 wk in the control group.There was no statistically significant difference in these demographic characteristics of the groups.Anterior chamber depth,lens thickness and axial length demonstrated statistically significant linear increases during the study period in the two groups(P<0.001 for each).There were no statistically significant differences between the two groups in terms of anterior chamber depth after laser treatment.Measurements of the lens thickness at 9 th and 12 th months(9 th month 3.70±0.22 vs 3.60±0.21 mm,P=0.017;12 th month 3.81±0.21 vs 3.69±0.22 mm,P=0.002)and the axial length at 12 th month(19.35±0.79 vs 19.13±0.54 mm,P=0.031)after laser treatment were statistically higher in the treatment group.CONCLUSION:Diode laser retinal photocoagulation treatment in premature infants seems to increase the lens thickness and axial length. 展开更多
关键词 diode laser photocoagulation laser treatment ocular biometric parameters retinopathy of prematurity
原文传递
Relative peripheral refractive errors in Chinese children with myopic anisometropia
5
作者 Yu-Ting Tong Yu-Qin Du +4 位作者 Shan-Shan Ge Li Chen Xiao-Qi Ma Yu-Juan Guo Yue-Hua Zhou 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第11期2074-2081,共8页
AIM:To compare relative peripheral refractive errors(RPREs)in Chinese children with and without myopic anisometropia(MAI)and to explore the relationship between RPRE and myopia.METHODS:This observational cross-section... AIM:To compare relative peripheral refractive errors(RPREs)in Chinese children with and without myopic anisometropia(MAI)and to explore the relationship between RPRE and myopia.METHODS:This observational cross-sectional study included 160 children divided into two groups according to the interocular spherical equivalent refraction(SER)difference≥1.0 D in the MAI group(n=80)and<1.0 D in the non-MAI group(n=80).The MAI group was further divided into two subgroups:ΔSER<2.0 D group and ΔSER≥2.0 D group.Basic ocular biometric parameters of axial length(AL),average keratometry(Ave K),cylinder(CYL),surface regularity index(SRI),and surface asymmetry index(SAI)were recorded.In addition,multispectral refraction topography was performed to measure RPRE,and the parameters were recorded as total refraction difference value(TRDV),refraction difference value(RDV)0-10,RDV10-20,RDV20-30,RDV30-40,RDV40-53,RDV-superior(RDV-S),RDV-inferior(RDV-I),RDV-temporal(RDV-T)and RDV-nasal(RDV-N).RESULTS:In the non-MAI group,the interocular differences of all parameters of RPRE were not significant.In the MAI group,the interocular differences of TRDV,RDV10-53,RDV-S,RDV-I,RDV-T,and RDV-N were significant.In subgroup analysis,the interocular differences of TRDV,RDV30-53,RDV-I,and RDV-T were significant in ΔSER<2.0 D group and ΔSER≥2.0 D group,but the interocular differences of RDV10-30,RDV-S and RDV-N were only significant in the ΔSER≥2.0 D group.In correlation analysis,ΔTRDV,ΔRDV 10-53,ΔRDV-S,and ΔRDV-N were negatively correlated with ΔSER but positively correlated with ΔAL.CONCLUSION:The more myopic eyes have larger hyperopic RPRE in Chinese children with MAI in certain retinal range,and partialΔRPRE is closely associated with ΔSER and ΔAL. 展开更多
关键词 myopia anisometropia relative peripheral refractive error ocular biometric parameters