期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Simulation of distributed optical fiber disturbance detection system based on Sagnac/Mach-Zehnder interferometer and cross-correlation location 被引量:2
1
作者 方捻 李杰 +2 位作者 王陆唐 黄肇明 杨烨 《Journal of Shanghai University(English Edition)》 CAS 2011年第2期115-118,共4页
A distributed optical fiber disturbance detection system consisted of a Sagnac interferometer and a Mach-Zehnder interferometer is demonstrated. Two interferometers outputs are connected to an electric band-pass filte... A distributed optical fiber disturbance detection system consisted of a Sagnac interferometer and a Mach-Zehnder interferometer is demonstrated. Two interferometers outputs are connected to an electric band-pass filter via a detector respectively. The central frequencies of the two filters are selected adaptively according to the disturbance frequency. The disturbance frequency is obtained by either frequency spectrum of the two interferometers outputs. An alarm is given out only when the Sagnac interferometer output is changed. A disturbance position is determined by calculating a time difference with a cross-correlation method between the filter output connected to the Sagnac interferometer and derivative of the filter output connected to the Mach-Zehnder interferometer. The frequency spectrum, derivative and cross-correlation are obtained by a signal processing system. Theory analysis and simulation results are presented. They show that the system structure and location method are effective, accurate, and immune to environmental variations. 展开更多
关键词 Sagnac interferometer Mach-Zehnder interferometer distributed optical fiber disturbance detection system cross-correlation LOCATION
下载PDF
DISTRIBUTED OPTICAL FIBER SENSOR FOR LONG-DISTANCE OIL PIPELINE HEALTH 被引量:3
2
作者 WANG Yannian JIANG Zhuangde +1 位作者 CHEN Xiaonan ZHAO Yulong 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2006年第1期137-139,共3页
A fully distributed optical fiber sensor (DOFS) for monitoring long-distance oil pipeline health is proposed based on optical time domain reflectometry (OTDR). A smart and sensitive optical fiber cable is installe... A fully distributed optical fiber sensor (DOFS) for monitoring long-distance oil pipeline health is proposed based on optical time domain reflectometry (OTDR). A smart and sensitive optical fiber cable is installed along the pipeline acting as a sensor, The experiments show that the cable swells when exposed to oil and induced additional bending losses inside the fiber, and the optical attenuation of the fiber coated by a thin skin with periodical hardness is sensitive to deformation and vibration caused by oil leakage, tampering, or mechanical impact. The region where the additional attenuation occurred is detected and located by DOFS based on OTDR, the types of pipeline accidents are identified according to the characteristics of transmitted optical power received by an optical power meter, Another prototype of DOFS based on a forward traveling frequency-modulated continuous-wave (FMCW) is also proposed to monitor pipeline. The advantages and disadvantages of DOFSs based on OTDR and FMCW are discussed. The experiments show that DOFSs are capable of detecting and locating distant oil pipeline leakages and damages in real time with an estimated precision of ten meters over tens of kilometers. 展开更多
关键词 optical fiber sensor Fault diagnostic Leak detection Oil pipeline
下载PDF
Intra-Cavity Absorption Gas Sensors Using Wavelength Modulation and Wavelength Sweep 被引量:2
3
作者 Kun Liu Wen-Cai Jing +6 位作者 Gang-Ding Peng Jian-Zhong Zhang Yan Wang Tie-Gen Liu Da-Gong Jia Hong-Xia Zhang Yi-Mo Zhang 《Journal of Electronic Science and Technology of China》 2008年第4期353-356,共4页
Wavelength modulation technique (WMT) and wavelength sweep technique (WST) are introduced into intra-cavity absorption gas sensors (ICAGS) for low concentration gas detection. The optimized parameters of the sys... Wavelength modulation technique (WMT) and wavelength sweep technique (WST) are introduced into intra-cavity absorption gas sensors (ICAGS) for low concentration gas detection. The optimized parameters of the system maximizing the signal-to-noise ratio (SNR) are found. Calibration of acetylene concentration and gas recognition are both realized. 展开更多
关键词 Gas detection optical fiber laser wavelength modulation wavelength sweep.
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部