The global distributions of eight principal tidal constituents, M2, S2, K1, O1, N2, K2, P1, and Q1, are derived using TOPEX/Poseidon and JASON-1(T/P-J) satellite altimeter data for 16 a. The intercomparison of the d...The global distributions of eight principal tidal constituents, M2, S2, K1, O1, N2, K2, P1, and Q1, are derived using TOPEX/Poseidon and JASON-1(T/P-J) satellite altimeter data for 16 a. The intercomparison of the derived harmonics at 7000 subsatellite track crossover points shows that the root mean square (RMS) values of the tidal height differences of the above eight constituents range from 1.19 cm to 2.67 cm, with an average of about 2 cm. The RMS values of the tidal height differences between T/P-J solutions and the harmonics from ground measurements at 152 tidal gauge stations for the above constituents range from 0.34 cm to 1.08 cm, and the relative deviations range from 0.031 to 0.211. The root sum square of the RMS differences of these eight constituents is 2.12 cm, showing the improvement of the present model over the existing global ocean tidal models. Based on the obtained tidal model the global ocean tidal energetics is studied and the global distribution of the tidal power input density by tide-generating force of each constituent is calculated, showing that the power input source regions of semidiurnal tides are mainly concentrated in the tropical belt between 30S and 30N, while the power input source regions of diurnal tides are mainly concentrated off the tropic oceans. The global energy dissipation rates of the M2, S2, K1, O1, N2, P1, K2 and Q1 tides are 2.424, 0.401, 0.334, 0.160, 0.113, 0.035, 0.030 and 0.006 TW, respectively. The total global tidal dissipation rate of these eight constituents amounts to 3.5 TW.展开更多
Study results of low temperature effects on the strength index and specific power input into rock failure are presented.It has been experimentally determined that within the range of-5 °С to-15 °С,there is...Study results of low temperature effects on the strength index and specific power input into rock failure are presented.It has been experimentally determined that within the range of-5 °С to-15 °С,there is a local minimum at which the compression strength and specific power input into failure of some rocks are 10%-50% lower than those at positive temperatures.展开更多
The study focuses on estimating the input power of a power plant from available data, using the theoretical inverter efficiency as the key parameter. The paper addresses the problem of missing data in power generation...The study focuses on estimating the input power of a power plant from available data, using the theoretical inverter efficiency as the key parameter. The paper addresses the problem of missing data in power generation systems and proposes an approach based on the efficiency formula widely documented in the literature. In the absence of input data, this method makes it possible to estimate the plant’s input power using data extracted from the site, in particular that provided by the Ministry of the Environment. The importance of this study lies in the need to accurately determine the input power in order to assess the overall performance of the energy system.展开更多
It is very important to predict the coupling between the cavity and the high power input source in the coupler design. In this paper, a time domain method is used to calculate the external quality factor Qext for the ...It is very important to predict the coupling between the cavity and the high power input source in the coupler design. In this paper, a time domain method is used to calculate the external quality factor Qext for the BEPC Ⅱ superconducting cavity. A comparison between simulation results and experimental results is presented. The results of simulation and measurement of Qext have a good agreement within an error of 10%. The geometry parameters related with Qext are also studied.展开更多
The BEPCII storage ring adopts two 500 MHz superconducting cavities (SCC). Each one is equipped with a 500 MHz input power coupler. The coupler is to feed 150 kW power in continuous wave (CW) mode with both standi...The BEPCII storage ring adopts two 500 MHz superconducting cavities (SCC). Each one is equipped with a 500 MHz input power coupler. The coupler is to feed 150 kW power in continuous wave (CW) mode with both standing and traveling wave modes. Due to high power feeding and high frequency of the coupler, its fabrication is a big challenge. The fabrication started with two key components, the window and the antenna. Up to now, two sets including windows and antennas have been made by IHEP. And a 270 kW RF power in CW has passed through the coupler during the high power test. The fabrication details are presented in this paper.展开更多
Input power is an important indicator for the safety testing of electrical and electronic products.Smart toilets have been frequently detected that the actual input power is inconsistent with the nominal power.Researc...Input power is an important indicator for the safety testing of electrical and electronic products.Smart toilets have been frequently detected that the actual input power is inconsistent with the nominal power.Research and analysis show that the accuracy of the input power measurement results of the smart toilet mainly depends on the temperature control principle and power test method of the product.This article mainly discusses the characteristics of product temperature control,the testing method of mean and peak power and its characteristics,which will provide reference for the input power test of the smart toilet,and will improve the accuracy of power measurement.展开更多
In high voltage input DC-DC converter, auxiliary winding of isolation transformer is usually used to supply power for control circuit. Due to the wide-range of input voltage, the variable output voltage of auxiliary w...In high voltage input DC-DC converter, auxiliary winding of isolation transformer is usually used to supply power for control circuit. Due to the wide-range of input voltage, the variable output voltage of auxiliary winding will cause a series of problems, such as variable drive pulse amplitude, increased driver switching devices loss and drive transformer core saturation. This paper analyzes the influence of variable output voltage of auxiliary winding in detail. A novel method is proposed to solve the problem of large variation range of auxiliary winding output voltage, which is adding a buck converter between the auxiliary winding and the control circuit. A dual switch forward convert has been designed with 300 V - 800 V input and 24 V/5 A output. The results show that this method is effective by comparing the different results of using buck converter or not.展开更多
针对智能反射面(IRS, intelligent reflecting surface)辅助的多输入单输出(MISO, multiple input singleoutput)无线携能通信(SWIPT, simultaneous wireless information and power transfer)系统,考虑基站最大发射功率、IRS反射相移...针对智能反射面(IRS, intelligent reflecting surface)辅助的多输入单输出(MISO, multiple input singleoutput)无线携能通信(SWIPT, simultaneous wireless information and power transfer)系统,考虑基站最大发射功率、IRS反射相移矩阵的单位膜约束和能量接收器的最小能量约束,以最大化信息传输速率为目标,联合优化了基站处的波束成形向量和智能反射面的反射波束成形向量。为解决非凸优化问题,提出了一种基于深度强化学习的深度确定性策略梯度(DDPG, deep deterministic policy gradient)算法。仿真结果表明,DDPG算法的平均奖励与学习率有关,在选取合适的学习率的条件下,DDPG算法能获得与传统优化算法相近的平均互信息,但运行时间明显低于传统的非凸优化算法,即使增加天线数和反射单元数,DDPG算法依然可以在较短的时间内收敛。这说明DDPG算法能有效地提高计算效率,更适合实时性要求较高的通信业务。展开更多
无小区大规模多输入多输出(Multiple-Input Multiple-Output,MIMO)与非正交多址接入(Non-Orthogonal Multiple Access,NOMA)都是未来6G的使能技术。无线携能通信(Simultaneous Wireless Information and Power Transfer,SWIPT)技术在进...无小区大规模多输入多输出(Multiple-Input Multiple-Output,MIMO)与非正交多址接入(Non-Orthogonal Multiple Access,NOMA)都是未来6G的使能技术。无线携能通信(Simultaneous Wireless Information and Power Transfer,SWIPT)技术在进行信息解码的同时收集能量,与无小区大规模MIMO-NOMA优势互补。文中基于SWIPT研究无小区大规模MIMO-NOMA系统中的能量效率问题,通过联合优化功率分配系数和SWIPT的时隙切换(Time Switching,TS)系数,提高系统的能量效率。为了最大化能量效率,采用布谷鸟算法设计功率分配系数。考虑一种特殊情况,将所有终端的TS系数设置相同,进而推导了最佳TS系数的封闭表达式。仿真结果表明,相较于几种已有方案,文中提出的优化方案可以显著提升系统的能量效率。展开更多
基金The National Natural Science Foundation of China under contract No. 40676009 and 40606006the Basic Research Project of Qingdao Science and Technology Program under contract No. 11-1-4-98-jch
文摘The global distributions of eight principal tidal constituents, M2, S2, K1, O1, N2, K2, P1, and Q1, are derived using TOPEX/Poseidon and JASON-1(T/P-J) satellite altimeter data for 16 a. The intercomparison of the derived harmonics at 7000 subsatellite track crossover points shows that the root mean square (RMS) values of the tidal height differences of the above eight constituents range from 1.19 cm to 2.67 cm, with an average of about 2 cm. The RMS values of the tidal height differences between T/P-J solutions and the harmonics from ground measurements at 152 tidal gauge stations for the above constituents range from 0.34 cm to 1.08 cm, and the relative deviations range from 0.031 to 0.211. The root sum square of the RMS differences of these eight constituents is 2.12 cm, showing the improvement of the present model over the existing global ocean tidal models. Based on the obtained tidal model the global ocean tidal energetics is studied and the global distribution of the tidal power input density by tide-generating force of each constituent is calculated, showing that the power input source regions of semidiurnal tides are mainly concentrated in the tropical belt between 30S and 30N, while the power input source regions of diurnal tides are mainly concentrated off the tropic oceans. The global energy dissipation rates of the M2, S2, K1, O1, N2, P1, K2 and Q1 tides are 2.424, 0.401, 0.334, 0.160, 0.113, 0.035, 0.030 and 0.006 TW, respectively. The total global tidal dissipation rate of these eight constituents amounts to 3.5 TW.
文摘Study results of low temperature effects on the strength index and specific power input into rock failure are presented.It has been experimentally determined that within the range of-5 °С to-15 °С,there is a local minimum at which the compression strength and specific power input into failure of some rocks are 10%-50% lower than those at positive temperatures.
文摘The study focuses on estimating the input power of a power plant from available data, using the theoretical inverter efficiency as the key parameter. The paper addresses the problem of missing data in power generation systems and proposes an approach based on the efficiency formula widely documented in the literature. In the absence of input data, this method makes it possible to estimate the plant’s input power using data extracted from the site, in particular that provided by the Ministry of the Environment. The importance of this study lies in the need to accurately determine the input power in order to assess the overall performance of the energy system.
基金Supported by National Natural Science Foundation of China(k711360503)
文摘It is very important to predict the coupling between the cavity and the high power input source in the coupler design. In this paper, a time domain method is used to calculate the external quality factor Qext for the BEPC Ⅱ superconducting cavity. A comparison between simulation results and experimental results is presented. The results of simulation and measurement of Qext have a good agreement within an error of 10%. The geometry parameters related with Qext are also studied.
基金Supported by National Natural Science Foundation of China (k711360503)
文摘The BEPCII storage ring adopts two 500 MHz superconducting cavities (SCC). Each one is equipped with a 500 MHz input power coupler. The coupler is to feed 150 kW power in continuous wave (CW) mode with both standing and traveling wave modes. Due to high power feeding and high frequency of the coupler, its fabrication is a big challenge. The fabrication started with two key components, the window and the antenna. Up to now, two sets including windows and antennas have been made by IHEP. And a 270 kW RF power in CW has passed through the coupler during the high power test. The fabrication details are presented in this paper.
文摘Input power is an important indicator for the safety testing of electrical and electronic products.Smart toilets have been frequently detected that the actual input power is inconsistent with the nominal power.Research and analysis show that the accuracy of the input power measurement results of the smart toilet mainly depends on the temperature control principle and power test method of the product.This article mainly discusses the characteristics of product temperature control,the testing method of mean and peak power and its characteristics,which will provide reference for the input power test of the smart toilet,and will improve the accuracy of power measurement.
文摘In high voltage input DC-DC converter, auxiliary winding of isolation transformer is usually used to supply power for control circuit. Due to the wide-range of input voltage, the variable output voltage of auxiliary winding will cause a series of problems, such as variable drive pulse amplitude, increased driver switching devices loss and drive transformer core saturation. This paper analyzes the influence of variable output voltage of auxiliary winding in detail. A novel method is proposed to solve the problem of large variation range of auxiliary winding output voltage, which is adding a buck converter between the auxiliary winding and the control circuit. A dual switch forward convert has been designed with 300 V - 800 V input and 24 V/5 A output. The results show that this method is effective by comparing the different results of using buck converter or not.
文摘针对智能反射面(IRS, intelligent reflecting surface)辅助的多输入单输出(MISO, multiple input singleoutput)无线携能通信(SWIPT, simultaneous wireless information and power transfer)系统,考虑基站最大发射功率、IRS反射相移矩阵的单位膜约束和能量接收器的最小能量约束,以最大化信息传输速率为目标,联合优化了基站处的波束成形向量和智能反射面的反射波束成形向量。为解决非凸优化问题,提出了一种基于深度强化学习的深度确定性策略梯度(DDPG, deep deterministic policy gradient)算法。仿真结果表明,DDPG算法的平均奖励与学习率有关,在选取合适的学习率的条件下,DDPG算法能获得与传统优化算法相近的平均互信息,但运行时间明显低于传统的非凸优化算法,即使增加天线数和反射单元数,DDPG算法依然可以在较短的时间内收敛。这说明DDPG算法能有效地提高计算效率,更适合实时性要求较高的通信业务。
文摘无小区大规模多输入多输出(Multiple-Input Multiple-Output,MIMO)与非正交多址接入(Non-Orthogonal Multiple Access,NOMA)都是未来6G的使能技术。无线携能通信(Simultaneous Wireless Information and Power Transfer,SWIPT)技术在进行信息解码的同时收集能量,与无小区大规模MIMO-NOMA优势互补。文中基于SWIPT研究无小区大规模MIMO-NOMA系统中的能量效率问题,通过联合优化功率分配系数和SWIPT的时隙切换(Time Switching,TS)系数,提高系统的能量效率。为了最大化能量效率,采用布谷鸟算法设计功率分配系数。考虑一种特殊情况,将所有终端的TS系数设置相同,进而推导了最佳TS系数的封闭表达式。仿真结果表明,相较于几种已有方案,文中提出的优化方案可以显著提升系统的能量效率。