A europium chelate of 5-chlorosulfoyl-2- thenoyltrifluoroacetone(CTTA)was investigated for precolumn derivatization of protein for high performance liquid chromatography.This new label was highly fluorescent and suita...A europium chelate of 5-chlorosulfoyl-2- thenoyltrifluoroacetone(CTTA)was investigated for precolumn derivatization of protein for high performance liquid chromatography.This new label was highly fluorescent and suitable for time-resolved fluorometric detection.The detective limit of protein is less than 0.3ug in sample with a volume of 100ul.Theoretically,the new label can also be used in gel electrophoresis and protein blotting.展开更多
Artificial molecular chaperone (AMC) and ion exchange chromatography (IEC) were integrated, thus a new refolding method, artificial molecular chaperone-ion exchange chromatography (AMC-IEC) was developed. Compar...Artificial molecular chaperone (AMC) and ion exchange chromatography (IEC) were integrated, thus a new refolding method, artificial molecular chaperone-ion exchange chromatography (AMC-IEC) was developed. Compared with AMC and IEC, the activity recovery of lysozyme obtained by AMC-IEC was much higher in the investigated range of initial protein concentrations, and the results show that AMC-IEC is very efficient for protein refolding at high concentrations. When the initial concentration of lysozyme is 180 mg/mL, its activity recovery obtained by AMC-IEC is still as high as 76.6%, while the activity recoveries obtained by AMC and IEC are 45.6% and 42.4%, respectively.展开更多
文摘A europium chelate of 5-chlorosulfoyl-2- thenoyltrifluoroacetone(CTTA)was investigated for precolumn derivatization of protein for high performance liquid chromatography.This new label was highly fluorescent and suitable for time-resolved fluorometric detection.The detective limit of protein is less than 0.3ug in sample with a volume of 100ul.Theoretically,the new label can also be used in gel electrophoresis and protein blotting.
基金the National Natural Science Foundation in China(No.20705028)the Foundation of Key Laboratory of Modem Separation Science in Shaanxi Province(No.05JS61).
文摘Artificial molecular chaperone (AMC) and ion exchange chromatography (IEC) were integrated, thus a new refolding method, artificial molecular chaperone-ion exchange chromatography (AMC-IEC) was developed. Compared with AMC and IEC, the activity recovery of lysozyme obtained by AMC-IEC was much higher in the investigated range of initial protein concentrations, and the results show that AMC-IEC is very efficient for protein refolding at high concentrations. When the initial concentration of lysozyme is 180 mg/mL, its activity recovery obtained by AMC-IEC is still as high as 76.6%, while the activity recoveries obtained by AMC and IEC are 45.6% and 42.4%, respectively.