Comparison between Neuman(1975) and Jacob(1946) application for analysing pumping test data of unconfined aquifer 被引量:2
1
作者 Dana Mawlood Jwan Mustafa 《Journal of Groundwater Science and Engineering》 2016年第3期165-173,共9页
Pumping test of a water table aquifer is carried out to estimate the aquifer parameters, the obtained data were analysed through the solution of both Neuman(1975) and Jacob(1946) methods through AQTESOLV and Spreadshe... Pumping test of a water table aquifer is carried out to estimate the aquifer parameters, the obtained data were analysed through the solution of both Neuman(1975) and Jacob(1946) methods through AQTESOLV and Spreadsheet programs, the results of each methods are compared to evaluate the applicability and accuracy of the solution theoretically and practically. In the paper an example is presented, which is conducted for a constant rate pumping test from Ohio, in Fairborn(near Dayton), and it supplied by S.E. Norris(U.S. Geological Survey, Columbus, Ohio). The main objective of this study is to introduce both program and the way of the applications, and compare the results and the hand on of both programs in the field. 展开更多
关键词 Neuman(1975) Unconfined aquifer pumping test AQTESOLV program Microsoft Excel(Spreadsheet) program
下载PDF
Groundwater Potentials Estimation of a Basement Terrain Using Pumping Test Data for Parts of Sanga Local Government Area, Kaduna State, Northwestern Nigeria
2
作者 Hamidu Hassan Sidi Muhammad Waru +1 位作者 Garga Ali Bukar Kana Muhammad Abdullahi 《Open Journal of Modern Hydrology》 2016年第4期222-229,共8页
Aquifers derived from the crystalline basement rocks for parts of Sanga Local Government area of Kaduna State, Nigeria consist of clay, silt, sand, gravel and laterite materials which may be in various proportions. Us... Aquifers derived from the crystalline basement rocks for parts of Sanga Local Government area of Kaduna State, Nigeria consist of clay, silt, sand, gravel and laterite materials which may be in various proportions. Using Cooper-Jacobs non-equilibrium graphical method, the hydraulic properties were estimated from pumping test data of 18 boreholes. Conductivity varies from 1.02 × 10<sup>﹣2</sup> m/s to 4.07 × 10<sup>﹣2</sup> m/s and transmissivity varies from 1.14 × 10<sup>﹣1</sup> m<sup>2</sup>/s to 4.40 × 10<sup>﹣1</sup> m<sup>2</sup>/s. The values of specific capacity range between 1.03 × 10<sup>﹣1</sup> m<sup>2</sup>/s/m and 9.00 × 10<sup>﹣2</sup> m<sup>2</sup>/s/m, and these values indicate that the aquifers in the area have low to moderate ground water potentials. The low yield range of between 0.45 l/s and 1.00 l/s recorded in the area shows the heterogeneous and anisotropy nature of the basement aquifer system in terms of groundwater discharge. On the average, the boreholes assessed have potentials to sustain local to regional supply provided the best drilling method and materials are used and well completion properly done. 展开更多
关键词 pumping Test Heterogeneous ANISOTROPY CONDUCTIVITY Discharge Sanga
下载PDF
Numerical evaluation of the ground response induced by dewatering in a multi-aquifer system 被引量:3
3
作者 Yong-Xia Wu Qian Zheng +1 位作者 Annan Zhou Shui-Long Shen 《Geoscience Frontiers》 SCIE CAS CSCD 2021年第5期384-396,共13页
This study presents a numerical investigation of dewatering-induced settlement and wall deflection during pumping tests in Tianjin,China.Based on the measured groundwater head and building settlement during the pumpin... This study presents a numerical investigation of dewatering-induced settlement and wall deflection during pumping tests in Tianjin,China.Based on the measured groundwater head and building settlement during the pumping test,a three-dimensional liquid-solid coupling model is established by using the finite element method(FEM).The void ratio,hydraulic conductivity,and elastic modulus of each layer are back-calculated through the numerical model.The groundwater drawdown,seepage field,ground settlement,horizontal ground displacement,and diaphragm wall lateral deflection are analyzed using the FEM model.The simulated results demonstrate that(i)the maximum ground settlement outside of the excavation reaches to 82 mm due to the leakage effect of aquitards;(ii)large horizontal displacement occurs in the soil during the pumping test with a maximum value of 28.3 mm,and the installation of the diaphragm wall in the aquifer can reduce the horizontal displacement of the ground;(iii)long-term pumping causes a large lateral deflection of the diaphragm wall,and a maximum value of 23.2 mm occurs at the layer where the screens of the wells are located;and(iv)long-term large-scale pumping should be avoided before excavation. 展开更多
关键词 Excavation pit pumping test SETTLEMENT Wall deflection Numerical simulation
下载PDF
Influence of correlation scale errors on aquifer hydraulic conductivity inversion precision 被引量:1
4
作者 Yun-xiao Mu Lei Zhu +2 位作者 Tong-qing Shen Meng Zhang Yuan-yuan Zha 《Water Science and Engineering》 EI CAS CSCD 2020年第3期243-252,共10页
In order to investigate the influence of correlation scale error on the inversion precision of the hydraulic conductivity of the aquifer,the successive linear estimator(SLE)was used to invert the hydraulic conductivit... In order to investigate the influence of correlation scale error on the inversion precision of the hydraulic conductivity of the aquifer,the successive linear estimator(SLE)was used to invert the hydraulic conductivity field of a heterogeneous aquifer based on synthetic experiments.By increasing the numbers of observation wells and pumping tests,we analyzed the difference between the estimated and true values of hydraulic conductivity with different correlation scale errors.The relationships between the observation well number and the error in inversion results,and between the pumping test number and the error in inversion results were investigated.The results show that,if the amount of observed head data is insufficient,there will be errors in inversion results with changing correlation scale.Due to the existence of correlation scale error,the improvement of inversion precision gradually slows down with the increase of the amount of observed head data,which indicates that too much observed head data causes data redundancy.Therefore,for the synthetic experiments described in this paper,the observation well number should be less than 41,the pumping test number should be less than 17,and a more suitable method should be selected according to the precision requirements of specific situations in practical engineering. 展开更多
关键词 Hydraulic conductivity Parameter inversion Successive linear estimator Correlation scale error Observation well number pumping test number
下载PDF
Advantages of employing multilevel monitoring wells for design of tunnels subjected to multi-aquifer alluvial
5
作者 Mohsen GOLIAN Ebrahim SHARIFI TESHNIZI +6 位作者 Hamed TAVASOLI ROSTAMI Homayoon KATIBEH Mario PARISE Masoud MAHDAD Habib SAADAT Mehdi ABBASI Mahshid EBAD ARDESTANI 《Journal of Mountain Science》 SCIE CSCD 2021年第1期219-232,共14页
For tunnels being excavated through multiple knowledge of the aquifers’hydraulic head becomes essential for determining groundwater inflow into the tunnel and analyzing its stability,specifically using multilevel mon... For tunnels being excavated through multiple knowledge of the aquifers’hydraulic head becomes essential for determining groundwater inflow into the tunnel and analyzing its stability,specifically using multilevel monitoring systems.In the multi-aquifer alluvial section of the Glas tunnel(Iran),since the hydraulic head calculations were based on the data obtained from single-piezometer boreholes,the excavation risk was assessed to be at high level and the tunnel seemed to be unstable,thus an incorrect conclusion was derived from the misleading data.To take cost mitigation measures into account,it was necessary to calculate the hydraulic head at tunnel level accurately.By installing nested and clustered wells the mean hydraulic head was measured to be 70 m,significantly different from the 90 m previously determined by boreholes.Considering the updated value,the groundwater inflow and bulkhead load,formerly calculated as 0.65 m^(3)/s and 9.5 bars,were determined to be 0.49 m^(3)/s and 7.5 bars,respectively. 展开更多
关键词 Nested wells Clustered wells Hydraulic head pumping test Mechanized tunneling Iran
原文传递
Estimation of hydraulic parameters from pumping tests in a multiaquifer system
6
作者 Da Ha Gang Zheng +2 位作者 Haizuo Zhou Chaofeng Zeng Huihui Zhang 《Underground Space》 SCIE EI 2020年第3期210-222,共13页
The hydrogeologic conditions in Tianjin,China,are characterized by a system of multiple alternating aquifers and aquitards and a high groundwater level.Generally,the groundwater system to a depth of 70 m includes one ... The hydrogeologic conditions in Tianjin,China,are characterized by a system of multiple alternating aquifers and aquitards and a high groundwater level.Generally,the groundwater system to a depth of 70 m includes one phreatic aquifer and three semiconfined aquifers(AqI–AqIII).The distribution of aquifers varies greatly.Accurate estimates of aquifer parameters from pumping tests are essential in geotechnical engineering practice.In this study,the applicability of different models for estimating hydraulic parameters in a multiaquifer system is analyzed.To avoid errors in the graphic-analytical process and to enhance the efficiency and accuracy,a hybrid algorithm,called GALMA(a genetic algorithm(GA)combined with the Levenberg–Marquardt(LM)algorithm),is used with the Neuman and Witherspoon model and ratio method.The estimated values in the second and third semiconfined aquifers(AqII and AqIII)from various solutions are compared with the measured data.Further validations based on the prediction of the drawdown values are performed via a three dimensional numerical simulation. 展开更多
关键词 Hydraulic parameter Leaky aquifer pumping test Optimal approach
下载PDF
Assessment of Hydraulic Parameters and Protection Zones of Catchment Aquifers for Water Supply Network in NdéDivision, West-Cameroon (Central Africa)
7
作者 Roger Feumba Kemgang Dongmo Tchouta +3 位作者 Jean Ghislain Tabué Youmbi Valentin Yvan Emmanuel Mvondo Depesquidoux I. Tchaptchet Tchato Benjamin Ngounou Ngatcha 《Journal of Water Resource and Protection》 2021年第7期478-497,共20页
Ndé Division in West-Cameroon is facing with water supply although many attempts of restoring existing SCANWATER facilities by Bangangté Municipality. In order to address the issue, we assess the exploitable... Ndé Division in West-Cameroon is facing with water supply although many attempts of restoring existing SCANWATER facilities by Bangangté Municipality. In order to address the issue, we assess the exploitable pumping flow rate of catchment aquifers and its hydraulic properties by using Jacob and Theis method, and define protection zones with Hoffman and Lillich method. It emerges that the hydraulic conductivity of aquifer is in the order of 10<sup>-4</sup> m/sec, transmissivity varies from 10<sup>-4</sup> to 10<sup>-6</sup> m<sup>2</sup>/sec. Aquifer pumping flow rate (Q) varies between 1.5 and 10.5 m<sup>3</sup>/h. In volcanic rocks, aquifer is more productive (4.5 ≤ Q ≤ 10.5 m<sup>3</sup>/h). Transfer time of pollutants to aquifer varies from 3 to 56 days depending on rock-types and groundwater slope (0.03 - 0.13 m/m). Furthermore, 113,624 m and 1123 m are radius to be implemented for a better protection of groundwater against any form of pollutant. 展开更多
关键词 pumping tests Aquifer Properties Groundwater Protection Ndé Division West-Cameroon (Central Africa)
下载PDF
Identification of Aquifer Properties in the Eastern Part of Kushtia District, Bangladesh
8
作者 Md. Shahinuzzaman M. Nozibul Haque +1 位作者 Khan M. Nasir Uddin M. Alibuddin 《Journal of Geoscience and Environment Protection》 2020年第11期222-237,共16页
The present study has been undertaken to depict spatial distribution of different aquifer parameters in the eastern part of Kushtia district through a detailed hydrogeological survey. For this investigation, 119 litho... The present study has been undertaken to depict spatial distribution of different aquifer parameters in the eastern part of Kushtia district through a detailed hydrogeological survey. For this investigation, 119 lithologs and 92 pumping test data have been used. These data have been processed, analyzed, interpreted and krigged for the spatial assessment of the aquifer properties viz. transmissivity, hydraulic conductivity, hydraulic diffusivity, specific yield, radius of influence, and specific drawdown. It is seen from the investigation that the transmissivity and hydraulic conductivity values obtained from the pumping tests of the wells are varying from 1811 m<sup>2</sup>/day to 2568 m<sup>2</sup>/day and 32.5 m/day and 61.5 m/day respectively, the hydraulic diffusivity being ranging from 181,143 m<sup>2</sup>/day to 256,788 m<sup>2</sup>/day. The estimated specific yield of 17.97% - 23.46% supports that the area is dominated with coarse grained sands. This study reveals that the distribution of deep tube wells in the area are not within the radius of influence (638 - 760 m) each other, but few shallow and hand tube wells existed within the radius of influence. The estimated specific draw down is varying from 57 m/cumec to 126.1 m/cumec. From the overall analysis, it is found that the area is favorable for groundwater exploration. 展开更多
关键词 GROUNDWATER AQUIFER pumping Test TRANSMISSIVITY Hydraulic Conductivity Hydraulic Diffusivity Specific Yield Radius of Influence Specific Yield
下载PDF
Development of a Test Apparatus for Measurement of Hydraulic Fluid Efficiency
9
作者 Matt Jackson Brian Koehler 《润滑油》 CAS 2011年第5期28-33,共6页
With increasing demand for nonrenewable resources,energy conservation is critical.Efficiency gains allow more work to be performed while maintaining or even decreasing the energy expended in the process.Reducing the e... With increasing demand for nonrenewable resources,energy conservation is critical.Efficiency gains allow more work to be performed while maintaining or even decreasing the energy expended in the process.Reducing the energy consumed by a system results in favorable economic and environmental impact.An apparatus has been developed to measure hydraulic fluid efficiency in a stationary application.The system can be used to develop more efficient fluids,leading to increased work output or decreased energy consumption. 展开更多
关键词 mechanical and volumetric efficiency test pump test procedure
下载PDF
Interpretation of Groundwater Flow into Fractured Aquifer
10
作者 Sameh W.Al-Muqdadi Broder J.Merkel 《International Journal of Geosciences》 2012年第2期357-364,共8页
The region of investigation is part of the western desert of Iraq covering an area of about 12,400 km2, this region includes several large wadis discharging to the Euphrates River. Since the Tectonic features in parti... The region of investigation is part of the western desert of Iraq covering an area of about 12,400 km2, this region includes several large wadis discharging to the Euphrates River. Since the Tectonic features in particular fault zones play a significant role with respect to groundwater flow in hard rock terrains. The present research is focus on investigate lineaments that have been classified as suspected faults by means of remote sensing techniques and digital terrain evaluation in combination with interpolating groundwater heads and MLU pumping tests model in a fractured rock aquifer, Lineaments extraction approach is illustrated a fare matching with suspected faults, moreover these lineaments conducted an elevated permeability zone. 展开更多
关键词 Fault Interpretation Lineaments Extraction Remote Sensing Digital Terrain Model Analytical pumping Test Evaluation
下载PDF
Pumping speed of cryopump for xenon
11
作者 LING Gui-long WEI Li-jun CAI Guo-biao 《航空动力学报》 EI CAS CSCD 北大核心 2015年第7期1731-1736,共6页
The xenon pumping speed testing system of the large-diameter external cryopump was designed to meet the plume test requirements for prototype electric propulsion.The flowmeter method was utilized to measure the xenon ... The xenon pumping speed testing system of the large-diameter external cryopump was designed to meet the plume test requirements for prototype electric propulsion.The flowmeter method was utilized to measure the xenon pumping speed.The test results show that the averaged effective pumping speed of doublecryopumps is 52 200L/s,and that of single-cryopump is 27 100L/s.The pumping speed ratio of two configurations is 1.93.It can be concluded that the pumping speed has in linear relationship with the number of cryopump,and the coefficient is irrelevant with the gas type.The averaged effective pumping speed of xenon is less than its nominal pumping speed,and the averaged pumping efficiency is 0.83.Under the identical inflow conditions,the averaged effective pumping speed ratio of nitrogen is 0.53,slightly less than the theoretical pumping speed ratio of 0.55.Consequently,it can be concluded that results assessment of large-diameter external cryopump design index can guide the engineering application,showing certain reference significance. 展开更多