期刊文献+
共找到10篇文章
< 1 >
每页显示 20 50 100
Interactions of acetylcholinesterase with salvianolic acid B and rosmarinic acid from Salvia miltiorhiza water extract investigated by NMR relaxation rate
1
作者 GuoWei Yin Yi Ming Li +3 位作者 Wei Wei Shan Hao Jiang Da Yuan Zhu Wei Hong Du 《Chinese Chemical Letters》 SCIE CAS CSCD 2008年第6期747-751,共5页
In order to understand whether the ameliorating effect on old ages memory disorder by the root of Salvia miltiorhiza is related to the acetylcholinesterase (ACHE) inhibition, two main ingredients, salvianolic acid B... In order to understand whether the ameliorating effect on old ages memory disorder by the root of Salvia miltiorhiza is related to the acetylcholinesterase (ACHE) inhibition, two main ingredients, salvianolic acid B (1) and rosmarinic acid (2), which were isolated from S. miltiorhiza water extract, were investigated in vitro by NMR relaxation rate in this work. The results showed that the proton selective relaxation rates and the molecular rotational correlation time of proton pairs for compounds 1 and 2 increased significantly by adding of AChE in mixing solution. The study reveals that the two compounds might bind to the enzyme and have ACHE inhibitory effect, which could contribute to the ameliorating effect at some extent on old ages memory disorder. 展开更多
关键词 AChE inhibitors Salvianolic acid B Rosmarinic acid NMR relaxation rate
下载PDF
Measuring method of water surface wave relaxation rate based on linear array CCD
2
作者 CHEN Peng-zhen CHONG Jin-song 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2017年第3期215-222,共8页
Relaxation rate is a very crucial parameter in physics.For the water surface wave,its relaxation rate is directly relevantto the response time of disturbed spectrum returning back to its quasi-steady state.It is diffi... Relaxation rate is a very crucial parameter in physics.For the water surface wave,its relaxation rate is directly relevantto the response time of disturbed spectrum returning back to its quasi-steady state.It is difficult to be calculated directly asa function of different oceanographic and meteorological parameters.Previous researches were mainly based on experimentalmeasurements or parameterization.In this paper,a method based on the liner array charge-coupled device(CCD)is proposed tomeasure the relaxation rate of the water surface wave.Compared with the traditional methods?it can obtain the information ofsurface wave and current synchronously,and works well under a multi wind-wave environment.Wind wav^tank experimentswere carried out based on this method.The good consistency between the results calculated by this method and the traditionalrelaxation rate models shows the validity of the proposed method.This method can be further used to study the modulation theoryof surface waves by currents. 展开更多
关键词 linear array charge-coupled device water surface waves relaxation rate
下载PDF
A new linearly-combined bi-exponential model for kinetic analysis of the isometric relaxation process of Bufo gastrocnemius under electric stimulation in vitro 被引量:1
3
作者 GUO Rui LI Sheng-bing ZHAO Li-na ZHAO Yun-sheng LU Wei YUAN Pei DENG Ping LIAO Fei 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2007年第12期867-874,共8页
There was a slow-relaxing tail of skeletal muscles in vitro upon the inhibition of Ca2+-pump by cyclopiazonic acid (CPA). Herein, a new linearly-combined bi-exponential model to resolve this slow-relaxing tail from th... There was a slow-relaxing tail of skeletal muscles in vitro upon the inhibition of Ca2+-pump by cyclopiazonic acid (CPA). Herein, a new linearly-combined bi-exponential model to resolve this slow-relaxing tail from the fast-relaxing phase was investigated for kinetic analysis of the isometric relaxation process of Bufo gastrocnemius in vitro, in comparison to the single exponential model and the classical bi-exponential model. During repetitive stimulations at a 2-s interval by square pulses of a 2-ms duration at 12 V direct currency (DC), the isometric tension of Bufo gastrocnemius was recorded at 100 Hz. The relaxation curve with tensions falling from 90% of the peak to the 15th datum before next stimulation was analyzed by three exponential models using a program in MATLAB 6.5. Both the goodness of fit and the distribution of the residuals for the best fitting sup- ported the comparable validity of this new bi-exponential model for kinetic analysis of the relaxation process of the control muscles. After CPA treatment, however, this new bi-exponential model showed an obvious statistical superiority for kinetic analysis of the muscle relaxation process, and it gave the estimated rest tension consistent to that by experimentation, whereas both the classical bi-exponential model and the single exponential model gave biased rest tensions. Moreover, after the treatment of muscles by CPA, both the single exponential model and the classical bi-exponential model yielded lowered relaxation rates, nevertheless, this new bi-exponential model had relaxation rates of negligible changes except much higher rest tensions. These results suggest that this novel linearly-combined bi-exponential model is desirable for kinetic analysis of the relaxation process of muscles with altered Ca2+-pumping activity. 展开更多
关键词 Bufo gastrocnemius Ca^2+ -pump Cyclopiazonic acid (CPA) Linearly-combined bi-exponential model Muscle relaxation rate Residual distribution Rest tension
下载PDF
Investigation on Positive Correlation of Increased Brain Iron Deposition with Cognitive Impairment in Alzheimer Disease by Using Quantitative MR R2' Mapping 被引量:3
4
作者 覃媛媛 朱文珍 +4 位作者 占传家 赵凌云 王建枝 田青 王伟 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2011年第4期578-585,共8页
Brain iron deposition has been proposed to play an important role in the pathophysiology of Alzheimer disease(AD).The aim of this study was to investigate the correlation of brain iron accumulation with the severity... Brain iron deposition has been proposed to play an important role in the pathophysiology of Alzheimer disease(AD).The aim of this study was to investigate the correlation of brain iron accumulation with the severity of cognitive impairment in patients with AD by using quantitative MR relaxation rate R2' measurements.Fifteen patients with AD,15 age-and sex-matched healthy controls,and 30 healthy volunteers underwent 1.5T MR multi-echo T2 mapping and T2* mapping for the measurement of transverse relaxation rate R2'(R2'=R2*-R2).We statistically analyzed the R2' and iron concentrations of bilateral hippocampus(HP),parietal cortex(PC),frontal white matter(FWM),putamen(PU),caudate nucleus(CN),thalamus(TH),red nucleus(RN),substantia nigra(SN),and dentate nucleus(DN) of the cerebellum for the correlation with the severity of dementia.Two-tailed t-test,Student-Newman-Keuls test(ANOVA) and linear correlation test were used for statistical analysis.In 30 healthy volunteers,the R2' values of bilateral SN,RN,PU,CN,globus pallidus(GP),TH,and FWM were measured.The correlation with the postmortem iron concentration in normal adults was analyzed in order to establish a formula on the relationship between regional R2' and brain iron concentration.The iron concentration of regions of interest(ROI) in AD patients and controls was calculated by this formula and its correlation with the severity of AD was analyzed.Regional R2' was positively correlated with regional brain iron concentration in normal adults(r=0.977,P0.01).Iron concentrations in bilateral HP,PC,PU,CN,and DN of patients with AD were significantly higher than those of the controls(P0.05);Moreover,the brain iron concentrations,especially in parietal cortex and hippocampus at the early stage of AD,were positively correlated with the severity of patients' cognitive impairment(P0.05).The higher the R2' and iron concentrations were,the more severe the cognitive impairment was.Regional R2' and iron concentration in parietal cortex and hippocampus were positively correlated with the severity of AD patients' cognitive impairment,indicating that it may be used as a biomarker to evaluate the progression of AD. 展开更多
关键词 Alzheimer disease iron deposition quantitative magnetic resonance imaging transverse relaxation rate R2' imaging marker
下载PDF
Regulation of MRI contrast and cellular retention time by cellular interfacial distribution of Gd agents:Implications for stem cell tracking 被引量:1
5
作者 Yanhui Zhang Binbin Li +2 位作者 Bo Tan Hailu Zhang Zongwu Deng 《Magnetic Resonance Letters》 2022年第1期48-55,I0003,共9页
Human mesenchymal stem cells(hMSCs)were labeled with Dotarem or(Gd-DOTA)2-EM7(EM7Gd2)via electroporation(EP).Cellular transmission electron microscopy(TEM)reveals free distribution of Gd agents and formation of EM7Gd... Human mesenchymal stem cells(hMSCs)were labeled with Dotarem or(Gd-DOTA)2-EM7(EM7Gd2)via electroporation(EP).Cellular transmission electron microscopy(TEM)reveals free distribution of Gd agents and formation of EM7Gd2 clusters in the cytosol.Cellular magnetic resonance imaging(MRI)reveals that the free Gd agents induce MRI signal enhancement effect due to its fast exocytosis and subsequent interaction with intercellular water molecules.The EM7Gd2 clusters exhibits a longer intracellular retention time and induce a persistent MRI signal reduction effect.The cellular MRI results are interpreted by taking into account both T1 and T2 relaxation rates and their correlation with cellular binding structures of Dotarem and EM7Gd2. 展开更多
关键词 MRI Gd agent Cellular distribution relaxation rate Intracellular retention time
下载PDF
Transient electromagnetically induced transparency spectroscopy of^(87)Rb atoms in buffer gas
6
作者 Zi-Shan Xu Han-Mu Wang +1 位作者 Zeng-Li Ba Hong-Ping Liu 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第7期235-240,共6页
We study the transient response dynamics of^(87)Rb atomic vapor buffered in 8 torr Ne gas through an electromagnetically induced transparency configured inΛ-scheme.Experimentally,the temporal transmission spectra ver... We study the transient response dynamics of^(87)Rb atomic vapor buffered in 8 torr Ne gas through an electromagnetically induced transparency configured inΛ-scheme.Experimentally,the temporal transmission spectra versus probe detuning by switching on and off the coupling one show complex structures.The transmitted probe light intensity drops to a minimum value when the coupling light turns off,showing a strong absorption.Even at the moment of turning on the coupling light at a subsequent delayed time,the atomic medium shows a fast transient response.To account for the transient switching feature,in the time-dependent optical Bloch equation,we must take the transverse relaxation dephasing process of atomic vapor into account,as well as the fluorescence relaxation along with the optical absorption.This work supplies a technique to quantify the transverse relaxation time scale and to sensitively monitor its variation along the environment by observing the transient dynamics of coherent medium,which is helpful in characterizing the coherent feature of the atomic medium. 展开更多
关键词 electromagnetically induced transparency rubidium atom transverse relaxation rate
原文传递
Difference Analysis of MRI Apparent Diffusion Coefficient and R_(2)^(*)Value Between Small Hepatocellular Carcinoma and Cirrhosis Nodules
7
作者 Man Li Haiquan Wang 《Advances in Modern Oncology Research》 2020年第2期21-24,共4页
Objective:To investigate the differences of apparent diffusion coefficient and transverse relaxation rate(R_(2)^(*))in magnetic resonance imaging(MRI)between micro hepatocellular carcinoma and nodules of cirrhosis.Met... Objective:To investigate the differences of apparent diffusion coefficient and transverse relaxation rate(R_(2)^(*))in magnetic resonance imaging(MRI)between micro hepatocellular carcinoma and nodules of cirrhosis.Method:The clinical data of 68 patients with micro hepatocellular carcinoma(76 lesions)and 45 patients with nodular cirrhosis(48 lesions)were retrospectively analyzed.Diffusion weighted imaging and R_(2)^(*)imaging were performed on all patients.The differences of apparent diffusion coefficient and R_(2)^(*)values in patients with micro hepatocellular carcinoma and nodular cirrhosis were compared.Receiver operating characteristic(ROC)curves were drawn to evaluate the diagnostic efficacy of apparent diffusion coefficient values and R_(2)^(*)values for microhepatocellular carcinoma.Result:Compared with nodules of cirrhosis,the mean apparent diffusion coefficient and R_(2)^(*)value of micro-hepatocellular carcinoma were significantly decreased(P<0.05).The diagnosis threshold of apparent diffusion coefficient is at 1.35×10^(-3)mm^(2)/s,and the sensitivity for the diagnosis of micro-hepatocellular carcinoma was 80.88%,and the specificity was 91.11%,and the corresponding area under the ROC curve was 0.88;The diagnostic threshold for R_(2)^(*)value was at 53.96 Hz,and the sensitivity for the diagnosis of small hepatocellular carcinoma was 91.18%,and the specificity was 77.78%,and the corresponding area under the ROC curve was 0.84.Conclusion:MRI apparent diffusion coefficient value and R_(2)^(*)value can be used to differentiate and diagnose micro hepatocellular carcinoma and nodules of cirrhosis,in which the apparent diffusion coefficient of nodules of cirrhosis was less than 1.35×10^(-3)mm^(2)/s,R_(2)^(*)values were lower than 53.96 Hz may indicate the occurrence of nodular canceration. 展开更多
关键词 Small liver cancer Cirrhosis nodules Magnetic resonance imaging Apparent diffusion coefficient Transverse relaxation rate
下载PDF
Calculation of vibrational energy transition rates in acoustic relaxation processes for excitable gas molecules
8
作者 ZHANG Kesheng ZHANG Xiangqun +2 位作者 TANG Wenyong XIAO Yingqun JIANG Xueqin 《Chinese Journal of Acoustics》 CSCD 2018年第2期202-218,共17页
To research the correlation between vibrational energy transition rates and acoustic relaxation processes in excitable gases, the vibrational relaxation theory provided by Tanczos [J. Chem. Phy3. 25, 439 (1956)] is ... To research the correlation between vibrational energy transition rates and acoustic relaxation processes in excitable gases, the vibrational relaxation theory provided by Tanczos [J. Chem. Phy3. 25, 439 (1956)] is applied to calculate the energy transition rates of Vibrational- Vibrational (V-V) and Vibrational-Translational (V-T) energy transfer in gas mixtures. The results of calculation for the multi-relaxation processes in various gas mixtures, consisting of carbon dioxide, methane, chlorine, nitrogen, and oxygen at room temperature, demonstrate that the acoustic energy stagnated in every vibrational mode is coupled with each other through V-V energy exchanges. The vibrational excitation energy will relax through the V-T de-excitation path of the lowest mode because of its fastest V-T transition rate, resulting in that only one absorption peak can be measured for most of excitable gas mixtures. Thus, an effective model is provided to analyze how the vibrational energy transition rates affect the characteristics of acoustic relaxation processes and acoustic propagation in excitable gas mixtures. 展开更多
关键词 Calculation of vibrational energy transition rates in acoustic relaxation processes for excitable gas molecules
原文传递
Fluorinated [2]rotaxanes as sensitive ^(19)F MRI agents: Threading for higher sensitivity
9
作者 Lan Yang Yu Li +10 位作者 Mou Jiang Rui Zhou Hengjiang Cong Minghui Yang Lei Zhang Shenhui Li Yunhuang Yang Maili Liu Xin Zhou Zhong-Xing Jjiang Shizhen Chen 《Chinese Chemical Letters》 SCIE CAS CSCD 2024年第10期379-382,共4页
As a promising imaging technology,the low sensitivity of fluorine-19 magnetic resonance imaging(^(19)F MRI)severely hinders its biomedical applications.Herein,we have developed an unprecedented rotaxanebased strategy ... As a promising imaging technology,the low sensitivity of fluorine-19 magnetic resonance imaging(^(19)F MRI)severely hinders its biomedical applications.Herein,we have developed an unprecedented rotaxanebased strategy to improve the sensitivity of^(19)F MRI agents.By threading the fluorinated macrocycle into2-blade pinwheel[2]rotaxanes,the^(19)F longitudinal relaxation rate R1was dramatically increased,resulting in a significant^(19)F MRI signal intensity enhancement of up to 79%.Through comparative molecular dynamics studies using a series of solution and solid-state^(1)H/^(19)F nuclear magnetic resonance(^(1)H/^(19)F NMR)and molecular dynamics simulations,it was found that the formation of mechanical bonds dramatically restricts the motion of the wheel fluorines and thus increasing the R1for higher^(19)F MRI sensitivity.Besides a novel strategy for improving^(19)F MRI sensitivity,this study has established^(19)F NMR/MRI as a valuable technology for monitoring the molecular dynamics of rotaxanes,which may shed new light on high-performance^(19)F MRI agents and molecular devices. 展开更多
关键词 ROTAXANE ^(19)FMRI Imaging agent Mechanical bond relaxation rate
原文传递
Low-field NMR micro coils based on printed circuit board technology 被引量:1
10
作者 WU WeiPing LU RongSheng +2 位作者 ZHOU XinLong ZHANG YunYi NI ZhongHua 《Science China(Technological Sciences)》 SCIE EI CAS 2014年第10期2082-2088,共7页
Radiofrequency coil is one of the most important components for a nuclear magnetic resonance(NMR)instrument.In this article,some planar micro coils with an inner diameter of 2 mm and number of turns that varied from 1... Radiofrequency coil is one of the most important components for a nuclear magnetic resonance(NMR)instrument.In this article,some planar micro coils with an inner diameter of 2 mm and number of turns that varied from 1 to 11 were investigated based on the printed circuit board(PCB)technology.The electrical characterization of micro coils show that self-resonant frequencies are larger than 200 MHz.Then,an NMR measurement platform with a static magnetic field of 0.66 T was constructed and the signal to noise ratio(SNR)values of the NMR were analyzed.It was found that the SNR is optimal when the turn number of the micro coils is six and the excitation time of a 90°pulse is 0.8?s.Finally,we used the micro coil with six turns to study the transverse relaxation rate of copper sulfate pentahydrate aqueous solution with different concentrations.It was found that the transverse relaxation rate is proportional to the solution concentration.Results from the micro coil were verified by measurements using a Bruker Minispec MQ60. 展开更多
关键词 printed circuit board planar micro coil low-field nuclear magnetic resonance signal to noise ratio transverse relaxation rate
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部