A flux linkage compensation field oriented control (FOC) method was proposed to suppress the speed and torque ripples of a brushless wound-field synchronous motor in its starting process. The starting process was anal...A flux linkage compensation field oriented control (FOC) method was proposed to suppress the speed and torque ripples of a brushless wound-field synchronous motor in its starting process. The starting process was analyzed and the model of wound-field synchronous electric machine was established. The change of field current of the electric machine was described mathematically for simplified exciter and rotate rectifier. Based on the traditional field control, the flux linkage compensation was introduced in d-axis current to counteract the flux ripple. Some simulation and preliminary experiments were implemented. The results show that the proposed method is feasible and effective.展开更多
In order to improve the cold start performance of heavy duty diesel engine, electronically controlling the preheating of intake air by flame was researched. According to simulation and thermodynamic analysis about th...In order to improve the cold start performance of heavy duty diesel engine, electronically controlling the preheating of intake air by flame was researched. According to simulation and thermodynamic analysis about the partial working processes of the diesel engine, the amount of heat energy, enough to make the fuel self ignite at the end of compression process at different temperatures of coolant and intake air, was calculated. Several HY20 preheating plugs were used to heat up the intake air. Meanwhile, an electronic control system based on 8 bit micro controller unit (MCS 8031) was designed to automatically control the process of heating intake air. According to the various temperatures of coolant and ambient air, one plug or two plugs can automatically be selected to heat intake air. The demo experiment validated that the total system could operate successfully and achieve the scheduled function.展开更多
The tokamak start-up is a very important phase during the process to obtain a suitable equalizing plasma, and its governing model can be described as a set of nonlinear ordinary differential equations(ODEs). In this...The tokamak start-up is a very important phase during the process to obtain a suitable equalizing plasma, and its governing model can be described as a set of nonlinear ordinary differential equations(ODEs). In this paper, we first estimate the parameters in the original model and set up an accurate model to express how the variables change during the start-up phase, especially how the plasma current changes with respect to time and the loop voltage. Then, we apply the control parameterization method to obtain an approximate optimal parameters selection problem for the loop voltage design to achieve a desired plasma current target. Computational optimal control techniques such as the variational method and the costate method are employed to solve the problem, respectively. Finally, numerical simulations are performed and the results obtained via different methods are compared. Our numerical parameterization method and optimization procedure turn out to be effective.展开更多
Transmission control protocol (TCP) has undergone several transformations. Several proposals have been put forward to change the mechanisms of TCP congestion control to improve its performance. A line of research tend...Transmission control protocol (TCP) has undergone several transformations. Several proposals have been put forward to change the mechanisms of TCP congestion control to improve its performance. A line of research tends to reduce speed in the face of congestion thereby penalizing itself. In this group are the window based congestion control algorithms that use the size of congestion window to determine transmission speed. The two main algorithm of window based congestion control are the congestion avoidance and the slow start. The aim of this study is to survey the various modifications of window based congestion control. Much work has been done on congestion avoidance hence specific attention is placed on the slow start in order to motivate a new direction of research in network utility maximization. Mathematical modeling of the internet is discussed and proposals to improve TCP startup were reviewed. There are three lines of research on the improvement of slow start. A group uses the estimation of certain parameters to determine initial speed. The second group uses bandwidth estimation while the last group uses explicit request for network assistance to determine initial startup speed. The problems of each proposal are analyzed and a multiple startup for TCP is proposed. Multiple startups for TCP specify that startup speed is selectable from an n-arry set of algorithms. We then introduced the e-speed start which uses the prevailing network condition to determine a suitable starting speed.展开更多
基金Sponsored by the NSFC General Project (51177135)the Key Project of Natural Science Foundation of Shaanxi Province (2011GZ013)
文摘A flux linkage compensation field oriented control (FOC) method was proposed to suppress the speed and torque ripples of a brushless wound-field synchronous motor in its starting process. The starting process was analyzed and the model of wound-field synchronous electric machine was established. The change of field current of the electric machine was described mathematically for simplified exciter and rotate rectifier. Based on the traditional field control, the flux linkage compensation was introduced in d-axis current to counteract the flux ripple. Some simulation and preliminary experiments were implemented. The results show that the proposed method is feasible and effective.
文摘In order to improve the cold start performance of heavy duty diesel engine, electronically controlling the preheating of intake air by flame was researched. According to simulation and thermodynamic analysis about the partial working processes of the diesel engine, the amount of heat energy, enough to make the fuel self ignite at the end of compression process at different temperatures of coolant and intake air, was calculated. Several HY20 preheating plugs were used to heat up the intake air. Meanwhile, an electronic control system based on 8 bit micro controller unit (MCS 8031) was designed to automatically control the process of heating intake air. According to the various temperatures of coolant and ambient air, one plug or two plugs can automatically be selected to heat intake air. The demo experiment validated that the total system could operate successfully and achieve the scheduled function.
基金supported by the National Natural Science Foundation of China(Grant Nos.61104048 and 61473253)the National High Technology Research and Development Program of China(Grant No.2012AA041701)
文摘The tokamak start-up is a very important phase during the process to obtain a suitable equalizing plasma, and its governing model can be described as a set of nonlinear ordinary differential equations(ODEs). In this paper, we first estimate the parameters in the original model and set up an accurate model to express how the variables change during the start-up phase, especially how the plasma current changes with respect to time and the loop voltage. Then, we apply the control parameterization method to obtain an approximate optimal parameters selection problem for the loop voltage design to achieve a desired plasma current target. Computational optimal control techniques such as the variational method and the costate method are employed to solve the problem, respectively. Finally, numerical simulations are performed and the results obtained via different methods are compared. Our numerical parameterization method and optimization procedure turn out to be effective.
文摘Transmission control protocol (TCP) has undergone several transformations. Several proposals have been put forward to change the mechanisms of TCP congestion control to improve its performance. A line of research tends to reduce speed in the face of congestion thereby penalizing itself. In this group are the window based congestion control algorithms that use the size of congestion window to determine transmission speed. The two main algorithm of window based congestion control are the congestion avoidance and the slow start. The aim of this study is to survey the various modifications of window based congestion control. Much work has been done on congestion avoidance hence specific attention is placed on the slow start in order to motivate a new direction of research in network utility maximization. Mathematical modeling of the internet is discussed and proposals to improve TCP startup were reviewed. There are three lines of research on the improvement of slow start. A group uses the estimation of certain parameters to determine initial speed. The second group uses bandwidth estimation while the last group uses explicit request for network assistance to determine initial startup speed. The problems of each proposal are analyzed and a multiple startup for TCP is proposed. Multiple startups for TCP specify that startup speed is selectable from an n-arry set of algorithms. We then introduced the e-speed start which uses the prevailing network condition to determine a suitable starting speed.