With the rapid development of urban rail transit,there have been an urgent problem of excessive stray current.Because the stray current distribution is random and difficult to verify in the field,we designed an improv...With the rapid development of urban rail transit,there have been an urgent problem of excessive stray current.Because the stray current distribution is random and difficult to verify in the field,we designed an improved stray current experimental platform by replacing the simulated aqueous solution with a real soil environment and by calculating the transition resistance by measuring the soil resistivity,which makes up for the defects in the previous references.Firstly,the mathematical models of rail-drainage net and rail-drainage netground were established,and the analytical expressions of current and voltage of rail,drainage net and other structures were derived.In addition,the simulation model was built,and the mathematical analysis results were compared with the simulation results.Secondly,the accuracy of the improved stray current experimental platform was verified by comparing the measured and simulation results.Finally,based on the experimental results,the influence factors of stray current were analyzed.The relevant conclusions provide experimental data and theoretical reference for the study of stray current in urban rail transit.展开更多
The novel method to analyze metallic structure corrosion status was proposed in the presence of stray current in DC mass transit systems. Firstly, the characteristic parameter and the influence parameters for the corr...The novel method to analyze metallic structure corrosion status was proposed in the presence of stray current in DC mass transit systems. Firstly, the characteristic parameter and the influence parameters for the corrosion status were determined. Secondly, an experimental system was established for simulating the corrosion process within the stray current interference. Then, a predictive model for the corrosion status was built, using a support vector machine(SVM) method and experimental data. The data were divided into two sets, including training set and testing set. The training set was used to generate the SVM model and the testing set was used to evaluate the predictive performance of the SVM model. The results show that the relationship between the characteristic parameter and the influence parameters is nonlinear and the SVM model is suitable for predicting the corrosion status.展开更多
In order to explore the influence of soil resistivity on stray current in power supply system of urban rail transit,we establish an equivalent circuit model of the rail-to-ground structure based on resistance network ...In order to explore the influence of soil resistivity on stray current in power supply system of urban rail transit,we establish an equivalent circuit model of the rail-to-ground structure based on resistance network method first.After measuring the soil resistivity of a real subway system,a simulation model is established in Matlab to obtain the stray currents at different soil resistivities.Then the influence of soil resistivity on stray current is analyzed.Afterwards,to verify the rationality and reliability of the simulation model,we design a test circuit to measure the stray current and rail-to-ground voltage in a real subway system,and a comparison of the experimentally measured results and simulation results is presented.The results show that the stray current is the maximum when the soil resistivity is 211.57Ω·m;when the soil resistivity is 768.47Ω·m,the stray current is the minimum,that is,the smaller the soil resistivity,the greater the stray current.Therefore,the resistivity should be increased as much as possible when ramming the track foundation in urban rail transit system.展开更多
In contrast to the conventional direct current railway electrification system(DC-RES),the medium voltage direct current(MVDC)-RES is considered promising for long-distance high-speed corridors.In the MVDC-RES,traction...In contrast to the conventional direct current railway electrification system(DC-RES),the medium voltage direct current(MVDC)-RES is considered promising for long-distance high-speed corridors.In the MVDC-RES,traction substations(TSSs)are placed much farther and train loads are much heavier than in the conventional DC-RES.Hence,the MVDC-RES brings a drastic change in catenary voltage,TSS spacing,and train loading,which affects rail potential and stray current.In this connection,this work performs some significant quantitative analysis of rail potential and stray current in the MVDC-RES environment.An MVDC simulation model is proposed and different grounding schemes are analyzed for a single-train and two TSSs scenario as well as for a multi-train multi-TSS scenario.According to the simulation and analysis,the maximum values of rail potential and stray current at MVDC-RES distances and the maximum safe distance between adjacent TSSs are determined.展开更多
Based on the mechanism of stray current generation in underground structures,the concrete durability test device for stray current and sulphate in typical soil environment was designed to study the damage of concrete ...Based on the mechanism of stray current generation in underground structures,the concrete durability test device for stray current and sulphate in typical soil environment was designed to study the damage of concrete under the action of stray current and sulphate.The deterioration law of concrete under the action of stray current and sulphate was studied by microscopic techniques such as scanning electron microscopy (SEM) and X-ray diffraction (XRD).The microstructure of corroded concrete was observed to determine the phase composition of erosion products.The damage performances such as quality,strength,and dynamic elastic mode of corroded concrete were performed.The experimental results show that,under the action of stray current,the products of sulfate-eroded concrete are mainly gypsum,ettringite,and thaumasite;the stray current accelerates the hydration process of cement and the erosion of concrete by sulfate;when the concrete pores are filled with the erosion product,there is an increase of approximately 10% in the concrete compressive strength and dynamic elastic modulus;and the concrete compressive strength is more sensitive to the stray current electrification period than the current intensity.展开更多
The influence of the direction and magnitude of direct(DC)stray current on the disbonding performance of epoxy powder coating was studied by using electrochemical impedance spectroscopy and scanning electron microscop...The influence of the direction and magnitude of direct(DC)stray current on the disbonding performance of epoxy powder coating was studied by using electrochemical impedance spectroscopy and scanning electron microscopy technology.The results show that the application of DC stray current could accelerate the anodic dissolution.The peeling degree of the coating increases as the magnitude of positive DC stray current interference increases in the range of 2–8V.With 16V positive stray current disturbance,the degree of coating disbonding decreases.With the application of negative stray current,the coating peeling becomes more serious,and the degree of peeling increases as the DC stray current increases.展开更多
On the basis of analyzing the influencing factors and harmfulness of stray current, and discussing the existing problems of monitoring and prevention system for stray current, the integrated monitoring and prevention ...On the basis of analyzing the influencing factors and harmfulness of stray current, and discussing the existing problems of monitoring and prevention system for stray current, the integrated monitoring and prevention system for stray current in metro was developed. A net system of distributed computers for monitoring was set up. It can monitor the distribution of stray current in metro and the corrosion of the metal structure in the whole line. According to the situation of monitoring it can also control the drainage of its tank to reach the best effect and eliminate the negative effect of polarity drainage. By using the new type unilateral electric device, the problem of burning the rail by electric arc can be avoided. The unilateral electric device can be connected with the monitoring net system directly to realize the monitor in line and improve the reliability of the device.展开更多
The rail transit in sulfate-rich areas faces the combined effects of stray current and salt corrosion;however,the sulfate ion transport and concrete degradation mechanisms under such conditions are still unclear.To ad...The rail transit in sulfate-rich areas faces the combined effects of stray current and salt corrosion;however,the sulfate ion transport and concrete degradation mechanisms under such conditions are still unclear.To address this issue,novel sulfate transport and mesoscale splitting tests were designed,with a focus on considering the differences between the interfacial transition zone(ITZ)and cement matrix.Under the influence of stray current,the ITZ played a pivotal role in regulating the transport and mechanical failure processes of sulfate attack,while the tortuous and blocking effects of aggregates almost disappeared.This phenomenon was termed the“stray current-induced ITZ effect.”The experimental data revealed that the difference in sulfate ion transport attributed to the ITZ ranged from 1.90 to 2.31 times,while the difference in splitting strength ranged from 1.56 to 1.64 times.Through the real-time synchronization of splitting experiments and microsecond-responsive particle image velocimetry(PIV)technology,the mechanical properties were exposed to the consequences of the stray currentinduced ITZ effect.The number of splitting cracks in the concrete increased,rather than along the central axis,which was significantly different from the conditions without stray current and the ideal Brazilian disk test.Furthermore,a sulfate ion mass transfer model that incorporates reactivity and electrodiffusion was meticulously constructed.The embedded finite element calculation exhibited excellent agreement with the experimental results,indicating its reliability and accuracy.Additionally,the stress field was determined utilizing analytical methods,and the mechanism underlying crack propagation was successfully obtained.Compared to the cement matrix,a stray current led to more sulfates,more microstructure degradation,and greater increases in thickness and porosity in the ITZ,which was considered to be the essence of the stray current-induced ITZ effect.展开更多
Innovative advancement in power electronics is reshaping the conventional high-voltage transmission systems and has also opened a new paradigm for researchers to consider its benefits in the railway electrification sy...Innovative advancement in power electronics is reshaping the conventional high-voltage transmission systems and has also opened a new paradigm for researchers to consider its benefits in the railway electrification system(RES).In this regard,the medium-voltage direct current RES(MVDC-RES)is a key area of interest nowadays.In this paper,a secondary energy source(SES)consisting of renewable energies(REs)and energy storage systems(ESSs)is proposed to solve the issues of catenary voltage regulation,rail potential,and stray current in the MVDC-RES.Some of the major integration topologies of the SES are analyzed for MVDC-RES and the most effective one is proposed and implemented.The voltage at the point of connection(PoC)of the SES is used as a reference for controlling different operation modes of REs and ESSs.Moreover,feedforward control is used at the ESS converter to attain the quick response from the batteries for the desired operation.The proposed scheme improves the catenary voltage,and reduces the rail potential and stray current.Besides,the scheme provides higher energy density and reduces line losses.Simulation results are provided to validate the operation modes and advantages of the proposed scheme.展开更多
According to the service environment of subway structure,experiment is carried out to simulate influence of different loading levels to reinforcement corrosion of R.C element affected by stray current and chlorine sal...According to the service environment of subway structure,experiment is carried out to simulate influence of different loading levels to reinforcement corrosion of R.C element affected by stray current and chlorine salt solution. The current density of the corrosion is measured with the linear polarization resistance method,together with the qualitative analysis and quantitative calculation. Experiment shows that rebar corrosion current density increase accordingly with the increase of loading level. The quantitative relations and the time of rust corrosion of reinforcement are obtained.展开更多
With the combination of electrochemical corrosion due to stray current in running tunnels of metro, the formula to determine the corrosion products of rebars in reinforced concrete subjected to externally applied dire...With the combination of electrochemical corrosion due to stray current in running tunnels of metro, the formula to determine the corrosion products of rebars in reinforced concrete subjected to externally applied direct current is proposed, and the influence of corrosion on stress in concrete is also discussed. Meanwhile, the concept of corrosion stress field and its mathematical formula are presented in the paper. Finally the failure mode of concrete and its shortest breaking time are also analyzed.展开更多
Leakage currents accelerate surface degradation of metal contacts via small scale arcing across lubricating films,but recent observations suggest that metallic nanoparticle additives in lubricants may be useful to imp...Leakage currents accelerate surface degradation of metal contacts via small scale arcing across lubricating films,but recent observations suggest that metallic nanoparticle additives in lubricants may be useful to improve contact performance.These findings prompted a study that examined electrically induced surface pitting of steel contacts in the presence of several lubricating greases including some containing nanometer-sized colloidal silver(Ag)particles.Reciprocating rolling sphere-on-disk experiments were conducted under electro-tribological loads employing polyurea greases derived from mineral and synthetic base oils with and without additives.Friction forces and electrical resistance were monitored continuously during the tests;surface changes were characterized by means of optical spectroscopy,stylus profilometry,and scanning electron microscopy(SEM)including compositional analysis using energy dispersive spectroscopy(EDS).The observations demonstrate that surface pitting induced by arcing occurs mainly at the points were the rolling motion changes direction and that eroded metal is deposited along the wear grove.Micron-sized pits are formed which contain carbon and oxygen indicating that arcing causes decomposition of the hydrocarbon lubricants.Numerous findings indicate a significant inhibition of pitting is induced by the Ag nanoparticles;some greases containing other additives exhibit a similar,although less pronounced,effect.展开更多
基金supported by National Natural Science Foundation of China(Nos.51476073,51266004)Natural Science Foundation of Gansu Province(No.138RJZA199).
文摘With the rapid development of urban rail transit,there have been an urgent problem of excessive stray current.Because the stray current distribution is random and difficult to verify in the field,we designed an improved stray current experimental platform by replacing the simulated aqueous solution with a real soil environment and by calculating the transition resistance by measuring the soil resistivity,which makes up for the defects in the previous references.Firstly,the mathematical models of rail-drainage net and rail-drainage netground were established,and the analytical expressions of current and voltage of rail,drainage net and other structures were derived.In addition,the simulation model was built,and the mathematical analysis results were compared with the simulation results.Secondly,the accuracy of the improved stray current experimental platform was verified by comparing the measured and simulation results.Finally,based on the experimental results,the influence factors of stray current were analyzed.The relevant conclusions provide experimental data and theoretical reference for the study of stray current in urban rail transit.
基金Project(BE2010043) supported by the Technology Support Program of Jiangsu Province,ChinaProject(CXZZ13_0928) supported by the Graduate Education Innovation Project of Jiangsu Province,China
文摘The novel method to analyze metallic structure corrosion status was proposed in the presence of stray current in DC mass transit systems. Firstly, the characteristic parameter and the influence parameters for the corrosion status were determined. Secondly, an experimental system was established for simulating the corrosion process within the stray current interference. Then, a predictive model for the corrosion status was built, using a support vector machine(SVM) method and experimental data. The data were divided into two sets, including training set and testing set. The training set was used to generate the SVM model and the testing set was used to evaluate the predictive performance of the SVM model. The results show that the relationship between the characteristic parameter and the influence parameters is nonlinear and the SVM model is suitable for predicting the corrosion status.
基金National Natural Science Foundation of China(Nos.51476073,51266004)Natural Science Foundation of Gansu Province(No.1308RJZA199)。
文摘In order to explore the influence of soil resistivity on stray current in power supply system of urban rail transit,we establish an equivalent circuit model of the rail-to-ground structure based on resistance network method first.After measuring the soil resistivity of a real subway system,a simulation model is established in Matlab to obtain the stray currents at different soil resistivities.Then the influence of soil resistivity on stray current is analyzed.Afterwards,to verify the rationality and reliability of the simulation model,we design a test circuit to measure the stray current and rail-to-ground voltage in a real subway system,and a comparison of the experimentally measured results and simulation results is presented.The results show that the stray current is the maximum when the soil resistivity is 211.57Ω·m;when the soil resistivity is 768.47Ω·m,the stray current is the minimum,that is,the smaller the soil resistivity,the greater the stray current.Therefore,the resistivity should be increased as much as possible when ramming the track foundation in urban rail transit system.
文摘In contrast to the conventional direct current railway electrification system(DC-RES),the medium voltage direct current(MVDC)-RES is considered promising for long-distance high-speed corridors.In the MVDC-RES,traction substations(TSSs)are placed much farther and train loads are much heavier than in the conventional DC-RES.Hence,the MVDC-RES brings a drastic change in catenary voltage,TSS spacing,and train loading,which affects rail potential and stray current.In this connection,this work performs some significant quantitative analysis of rail potential and stray current in the MVDC-RES environment.An MVDC simulation model is proposed and different grounding schemes are analyzed for a single-train and two TSSs scenario as well as for a multi-train multi-TSS scenario.According to the simulation and analysis,the maximum values of rail potential and stray current at MVDC-RES distances and the maximum safe distance between adjacent TSSs are determined.
基金Funded by the National Natural Science Foundation of China (Nos.51590914 and 52078415)the Science and Technology Program of Shaanxi Province (Nos.2019KW-047, 20JY034, and SGSNXA00XGJS20015 60)the China Scholarship Council (No.202008610268)。
文摘Based on the mechanism of stray current generation in underground structures,the concrete durability test device for stray current and sulphate in typical soil environment was designed to study the damage of concrete under the action of stray current and sulphate.The deterioration law of concrete under the action of stray current and sulphate was studied by microscopic techniques such as scanning electron microscopy (SEM) and X-ray diffraction (XRD).The microstructure of corroded concrete was observed to determine the phase composition of erosion products.The damage performances such as quality,strength,and dynamic elastic mode of corroded concrete were performed.The experimental results show that,under the action of stray current,the products of sulfate-eroded concrete are mainly gypsum,ettringite,and thaumasite;the stray current accelerates the hydration process of cement and the erosion of concrete by sulfate;when the concrete pores are filled with the erosion product,there is an increase of approximately 10% in the concrete compressive strength and dynamic elastic modulus;and the concrete compressive strength is more sensitive to the stray current electrification period than the current intensity.
基金supported by“Civil Aviation Safety Capacity Building Fund(Construction of safety evaluation system for multibranch complex annular apron pipe network)”“the Fundamental Research Funds for the Central Universities(19CX05007A).”
文摘The influence of the direction and magnitude of direct(DC)stray current on the disbonding performance of epoxy powder coating was studied by using electrochemical impedance spectroscopy and scanning electron microscopy technology.The results show that the application of DC stray current could accelerate the anodic dissolution.The peeling degree of the coating increases as the magnitude of positive DC stray current interference increases in the range of 2–8V.With 16V positive stray current disturbance,the degree of coating disbonding decreases.With the application of negative stray current,the coating peeling becomes more serious,and the degree of peeling increases as the DC stray current increases.
文摘On the basis of analyzing the influencing factors and harmfulness of stray current, and discussing the existing problems of monitoring and prevention system for stray current, the integrated monitoring and prevention system for stray current in metro was developed. A net system of distributed computers for monitoring was set up. It can monitor the distribution of stray current in metro and the corrosion of the metal structure in the whole line. According to the situation of monitoring it can also control the drainage of its tank to reach the best effect and eliminate the negative effect of polarity drainage. By using the new type unilateral electric device, the problem of burning the rail by electric arc can be avoided. The unilateral electric device can be connected with the monitoring net system directly to realize the monitor in line and improve the reliability of the device.
基金supported by the State Major Program of National Natural Science Foundation of China(52090082)the National Key Research and Development Program of China(2022YFB2602200)the National Natural Science Foundation of China(52178423 and 52378398).
文摘The rail transit in sulfate-rich areas faces the combined effects of stray current and salt corrosion;however,the sulfate ion transport and concrete degradation mechanisms under such conditions are still unclear.To address this issue,novel sulfate transport and mesoscale splitting tests were designed,with a focus on considering the differences between the interfacial transition zone(ITZ)and cement matrix.Under the influence of stray current,the ITZ played a pivotal role in regulating the transport and mechanical failure processes of sulfate attack,while the tortuous and blocking effects of aggregates almost disappeared.This phenomenon was termed the“stray current-induced ITZ effect.”The experimental data revealed that the difference in sulfate ion transport attributed to the ITZ ranged from 1.90 to 2.31 times,while the difference in splitting strength ranged from 1.56 to 1.64 times.Through the real-time synchronization of splitting experiments and microsecond-responsive particle image velocimetry(PIV)technology,the mechanical properties were exposed to the consequences of the stray currentinduced ITZ effect.The number of splitting cracks in the concrete increased,rather than along the central axis,which was significantly different from the conditions without stray current and the ideal Brazilian disk test.Furthermore,a sulfate ion mass transfer model that incorporates reactivity and electrodiffusion was meticulously constructed.The embedded finite element calculation exhibited excellent agreement with the experimental results,indicating its reliability and accuracy.Additionally,the stress field was determined utilizing analytical methods,and the mechanism underlying crack propagation was successfully obtained.Compared to the cement matrix,a stray current led to more sulfates,more microstructure degradation,and greater increases in thickness and porosity in the ITZ,which was considered to be the essence of the stray current-induced ITZ effect.
文摘Innovative advancement in power electronics is reshaping the conventional high-voltage transmission systems and has also opened a new paradigm for researchers to consider its benefits in the railway electrification system(RES).In this regard,the medium-voltage direct current RES(MVDC-RES)is a key area of interest nowadays.In this paper,a secondary energy source(SES)consisting of renewable energies(REs)and energy storage systems(ESSs)is proposed to solve the issues of catenary voltage regulation,rail potential,and stray current in the MVDC-RES.Some of the major integration topologies of the SES are analyzed for MVDC-RES and the most effective one is proposed and implemented.The voltage at the point of connection(PoC)of the SES is used as a reference for controlling different operation modes of REs and ESSs.Moreover,feedforward control is used at the ESS converter to attain the quick response from the batteries for the desired operation.The proposed scheme improves the catenary voltage,and reduces the rail potential and stray current.Besides,the scheme provides higher energy density and reduces line losses.Simulation results are provided to validate the operation modes and advantages of the proposed scheme.
基金National Natural Science Foundation of China (Granted No.50808005)National"11-5"Science and Technology Supporting Program(Granted No.2006BAJ27B04)Major Program of Beijing Municipal Natural Science Foundation(Granted No.8100001)
文摘According to the service environment of subway structure,experiment is carried out to simulate influence of different loading levels to reinforcement corrosion of R.C element affected by stray current and chlorine salt solution. The current density of the corrosion is measured with the linear polarization resistance method,together with the qualitative analysis and quantitative calculation. Experiment shows that rebar corrosion current density increase accordingly with the increase of loading level. The quantitative relations and the time of rust corrosion of reinforcement are obtained.
文摘With the combination of electrochemical corrosion due to stray current in running tunnels of metro, the formula to determine the corrosion products of rebars in reinforced concrete subjected to externally applied direct current is proposed, and the influence of corrosion on stress in concrete is also discussed. Meanwhile, the concept of corrosion stress field and its mathematical formula are presented in the paper. Finally the failure mode of concrete and its shortest breaking time are also analyzed.
文摘Leakage currents accelerate surface degradation of metal contacts via small scale arcing across lubricating films,but recent observations suggest that metallic nanoparticle additives in lubricants may be useful to improve contact performance.These findings prompted a study that examined electrically induced surface pitting of steel contacts in the presence of several lubricating greases including some containing nanometer-sized colloidal silver(Ag)particles.Reciprocating rolling sphere-on-disk experiments were conducted under electro-tribological loads employing polyurea greases derived from mineral and synthetic base oils with and without additives.Friction forces and electrical resistance were monitored continuously during the tests;surface changes were characterized by means of optical spectroscopy,stylus profilometry,and scanning electron microscopy(SEM)including compositional analysis using energy dispersive spectroscopy(EDS).The observations demonstrate that surface pitting induced by arcing occurs mainly at the points were the rolling motion changes direction and that eroded metal is deposited along the wear grove.Micron-sized pits are formed which contain carbon and oxygen indicating that arcing causes decomposition of the hydrocarbon lubricants.Numerous findings indicate a significant inhibition of pitting is induced by the Ag nanoparticles;some greases containing other additives exhibit a similar,although less pronounced,effect.