Olympus Corporation developed texture and color enhancement imaging(TXI)as a novel image-enhancing endoscopic technique.This topic highlights a series of hot-topic articles that investigated the efficacy of TXI for ga...Olympus Corporation developed texture and color enhancement imaging(TXI)as a novel image-enhancing endoscopic technique.This topic highlights a series of hot-topic articles that investigated the efficacy of TXI for gastrointestinal disease identification in the clinical setting.A randomized controlled trial demonstrated improvements in the colorectal adenoma detection rate(ADR)and the mean number of adenomas per procedure(MAP)of TXI compared with those of white-light imaging(WLI)observation(58.7%vs 42.7%,adjusted relative risk 1.35,95%CI:1.17-1.56;1.36 vs 0.89,adjusted incident risk ratio 1.48,95%CI:1.22-1.80,respectively).A cross-over study also showed that the colorectal MAP and ADR in TXI were higher than those in WLI(1.5 vs 1.0,adjusted odds ratio 1.4,95%CI:1.2-1.6;58.2%vs 46.8%,1.5,1.0-2.3,respectively).A randomized controlled trial demonstrated non-inferiority of TXI to narrow-band imaging in the colorectal mean number of adenomas and sessile serrated lesions per procedure(0.29 vs 0.30,difference for non-inferiority-0.01,95%CI:-0.10 to 0.08).A cohort study found that scoring for ulcerative colitis severity using TXI could predict relapse of ulcerative colitis.A cross-sectional study found that TXI improved the gastric cancer detection rate compared to WLI(0.71%vs 0.29%).A cross-sectional study revealed that the sensitivity and accuracy for active Helicobacter pylori gastritis in TXI were higher than those of WLI(69.2%vs 52.5%and 85.3%vs 78.7%,res-pectively).In conclusion,TXI can improve gastrointestinal lesion detection and qualitative diagnosis.Therefore,further studies on the efficacy of TXI in clinical practice are required.展开更多
Colonoscopy is the gold standard for the screening and diagnosis of colorectal cancer,resulting in a decrease in the incidence and mortality of colon cancer.However,it has a 21%rate of missed polyps.Several strategies...Colonoscopy is the gold standard for the screening and diagnosis of colorectal cancer,resulting in a decrease in the incidence and mortality of colon cancer.However,it has a 21%rate of missed polyps.Several strategies have been devised to increase polyp detection rates and improve their characterization and delimi-tation.These include chromoendoscopy(CE),the use of other devices such as Endo cuffs,and major advances in endoscopic equipment[high definition,magnification,narrow band imaging,i-scan,flexible spectral imaging color enhancement,texture and color enhancement imaging(TXI),etc.].In the retrospective study by Hiramatsu et al,they compared white-light imaging with CE,TXI,and CE+TXI to determine which of these strategies allows for better definition and delimitation of polyps.They concluded that employing CE associated with TXI stands out as the most effective method to utilize.It remains to be demonstrated whether these results are extrapolatable to other types of virtual CE.Additionally,further investigation is needed in order to ascertain whether this strategy could lead to a reduction in the recurrence of excised lesions and potentially lower the occurrence of interval cancer.展开更多
BACKGROUND Accurate diagnosis and early resection of colorectal polyps are important to prevent the occurrence of colorectal cancer.However,technical factors and morphological factors of polyps itself can lead to miss...BACKGROUND Accurate diagnosis and early resection of colorectal polyps are important to prevent the occurrence of colorectal cancer.However,technical factors and morphological factors of polyps itself can lead to missed diagnoses.Imageenhanced endoscopy and chromoendoscopy(CE)have been developed to facilitate an accurate diagnosis.There have been no reports on visibility using a combination of texture and color enhancement imaging(TXI)and CE for colorectal tumors.AIM To investigate the visibility of margins and surfaces with the combination of TXI and CE for colorectal lesions.METHODS This retrospective study included patients who underwent lower gastrointestinal endoscopy at the Toyoshima Endoscopy Clinic.We extracted polyps that were resected and diagnosed as adenomas or serrated polyps(hyperplastic polyps and sessile serrated lesions)from our endoscopic database.An expert endoscopist performed the lower gastrointestinal endoscopies and observed the lesion using white light imaging(WLI),TXI,CE,and TXI+CE modalities.Indigo carmine dye was used for CE.Three expert endoscopists rated the visibility of the margin and surface patterns in four ranks,from 1 to 4.The primary outcomes were the average visibility scores for the margin and surface patterns based on the WLI,TXI,CE,and TXI+CE observations.Visibility scores between the four modalities were compared by the Kruskal-Wallis and Dunn tests.RESULTS A total of 48 patients with 81 polyps were assessed.The histological subtypes included 50 tubular adenomas,16 hyperplastic polyps,and 15 sessile serrated lesions.The visibility scores for the margins based on WLI,TXI,CE,and TXI+CE were 2.44±0.93,2.90±0.93,3.37±0.74,and 3.75±0.49,respectively.The visibility scores for the surface based on WLI,TXI,CE,and TXI+CE were 2.25±0.80,2.84±0.84,3.12±0.72,and 3.51±0.60,respectively.The visibility scores for the detection and surface on TXI were significantly lower than that on CE but higher than that on WLI(P<0.001).The visibility scores for the margin and surface on TXI+CE were significantly higher than those on CE(P<0.001).In the sub-analysis of adenomas,the visibility for the margin and surface on TXI+CE was significantly better than that on WLI,TXI,and CE(P<0.001).In the sub-analysis of serrated polyps,the visibility for the margin and surface on TXI+CE was also significantly better than that on WLI,TXI,and CE(P<0.001).CONCLUSION TXI+CE enhanced the visibility of the margin and surface compared to WLI,TXI,and CE for colorectal lesions.展开更多
BACKGROUND Olympus Corporation has developed texture and color enhancement imaging(TXI)as a novel image-enhancing endoscopic technique.AIM To investigate the effectiveness of TXI in identifying colorectal adenomas usi...BACKGROUND Olympus Corporation has developed texture and color enhancement imaging(TXI)as a novel image-enhancing endoscopic technique.AIM To investigate the effectiveness of TXI in identifying colorectal adenomas using magnifying observation.METHODS Colorectal adenomas were observed by magnified endoscopy using white light imaging(WLI),TXI,narrow band imaging(NBI),and chromoendoscopy(CE).This study adopted mode 1 of TXI.Adenomas were confirmed by histological examination.TXI visibility was compared with the visibility of WLI,NBI,and CE for tumor margin,and vessel and surface patterns of the Japan NBI expert team(JNET)classification.Three expert endoscopists and three non-expert endoscopists evaluated the visibility scores,which were classified as 1,2,3,and 4.RESULTS Sixty-one consecutive adenomas were evaluated.The visibility score for tumor margin of TXI(3.47±0.79)was significantly higher than that of WLI(2.86±1.02,P<0.001),but lower than that of NBI(3.76±0.52,P<0.001),regardless of the endoscopist’s expertise.TXI(3.05±0.79)had a higher visibility score for the vessel pattern of JNET classification than WLI(2.17±0.90,P<0.001)and CE(2.47±0.87,P<0.001),but lower visibility score than NBI(3.79±0.47,P<0.001),regardless of the experience of endoscopists.For the visibility score for the surface pattern of JNET classification,TXI(2.89±0.85)was superior to WLI(1.95±0.79,P<0.01)and CE(2.75±0.90,P=0.002),but inferior to NBI(3.67±0.55,P<0.001).CONCLUSION TXI provided higher visibility than WLI,lower than NBI,and comparable to or higher than CE in the magnified observation of colorectal adenomas.展开更多
Texture-based visualization method is a common method in the visualization of vector field data.Aiming at adding color mapping to the texture of ocean vector field and solving the ambiguity of vector direction in text...Texture-based visualization method is a common method in the visualization of vector field data.Aiming at adding color mapping to the texture of ocean vector field and solving the ambiguity of vector direction in texture image,a new color texture enhancement algorithm based on the Line Integral Convolution(LIC)for the vector field data is proposed,which combines the HSV color mapping and cumulative distribution function calculation of vector field data.This algorithm can be summarized as follows:firstly,the vector field data is convoluted twice by line integration to get the gray texture image.Secondly,the method of mapping vector data to each component of the HSV color space is established.And then,the vector field data is mapped into HSV color space and converted from HSV to RGB values to get the color image.Thirdly,the cumulative distribution function of the RGB color components of the gray texture image and the color image is constructed to enhance the gray texture and RGB color values.Finally,both the gray texture image and the color image are fused to get the color texture.The experimental results show that the proposed LIC color texture enhancement algorithm is capable of generating a better display of vector field data.Furthermore,the ambiguity of vector direction in the texture images is solved and the direction information of the vector field is expressed more accurately.展开更多
Texture and color enhancement imaging(TXI)has been developed as a novel image-enhancing endoscopy.However,the effectiveness of TXI detecting adenomas is inferior to narrow band imaging.Thus,future studies will need to...Texture and color enhancement imaging(TXI)has been developed as a novel image-enhancing endoscopy.However,the effectiveness of TXI detecting adenomas is inferior to narrow band imaging.Thus,future studies will need to focus on investigating the feasibility of such combination in clinical settings in order to provide patients with more accurate diagnoses.展开更多
文摘Olympus Corporation developed texture and color enhancement imaging(TXI)as a novel image-enhancing endoscopic technique.This topic highlights a series of hot-topic articles that investigated the efficacy of TXI for gastrointestinal disease identification in the clinical setting.A randomized controlled trial demonstrated improvements in the colorectal adenoma detection rate(ADR)and the mean number of adenomas per procedure(MAP)of TXI compared with those of white-light imaging(WLI)observation(58.7%vs 42.7%,adjusted relative risk 1.35,95%CI:1.17-1.56;1.36 vs 0.89,adjusted incident risk ratio 1.48,95%CI:1.22-1.80,respectively).A cross-over study also showed that the colorectal MAP and ADR in TXI were higher than those in WLI(1.5 vs 1.0,adjusted odds ratio 1.4,95%CI:1.2-1.6;58.2%vs 46.8%,1.5,1.0-2.3,respectively).A randomized controlled trial demonstrated non-inferiority of TXI to narrow-band imaging in the colorectal mean number of adenomas and sessile serrated lesions per procedure(0.29 vs 0.30,difference for non-inferiority-0.01,95%CI:-0.10 to 0.08).A cohort study found that scoring for ulcerative colitis severity using TXI could predict relapse of ulcerative colitis.A cross-sectional study found that TXI improved the gastric cancer detection rate compared to WLI(0.71%vs 0.29%).A cross-sectional study revealed that the sensitivity and accuracy for active Helicobacter pylori gastritis in TXI were higher than those of WLI(69.2%vs 52.5%and 85.3%vs 78.7%,res-pectively).In conclusion,TXI can improve gastrointestinal lesion detection and qualitative diagnosis.Therefore,further studies on the efficacy of TXI in clinical practice are required.
文摘Colonoscopy is the gold standard for the screening and diagnosis of colorectal cancer,resulting in a decrease in the incidence and mortality of colon cancer.However,it has a 21%rate of missed polyps.Several strategies have been devised to increase polyp detection rates and improve their characterization and delimi-tation.These include chromoendoscopy(CE),the use of other devices such as Endo cuffs,and major advances in endoscopic equipment[high definition,magnification,narrow band imaging,i-scan,flexible spectral imaging color enhancement,texture and color enhancement imaging(TXI),etc.].In the retrospective study by Hiramatsu et al,they compared white-light imaging with CE,TXI,and CE+TXI to determine which of these strategies allows for better definition and delimitation of polyps.They concluded that employing CE associated with TXI stands out as the most effective method to utilize.It remains to be demonstrated whether these results are extrapolatable to other types of virtual CE.Additionally,further investigation is needed in order to ascertain whether this strategy could lead to a reduction in the recurrence of excised lesions and potentially lower the occurrence of interval cancer.
基金Our study was approved by the ethics committee of the Certified Institutional Review Board of the Yoyogi Mental Clinic(certificate number.RKK227).
文摘BACKGROUND Accurate diagnosis and early resection of colorectal polyps are important to prevent the occurrence of colorectal cancer.However,technical factors and morphological factors of polyps itself can lead to missed diagnoses.Imageenhanced endoscopy and chromoendoscopy(CE)have been developed to facilitate an accurate diagnosis.There have been no reports on visibility using a combination of texture and color enhancement imaging(TXI)and CE for colorectal tumors.AIM To investigate the visibility of margins and surfaces with the combination of TXI and CE for colorectal lesions.METHODS This retrospective study included patients who underwent lower gastrointestinal endoscopy at the Toyoshima Endoscopy Clinic.We extracted polyps that were resected and diagnosed as adenomas or serrated polyps(hyperplastic polyps and sessile serrated lesions)from our endoscopic database.An expert endoscopist performed the lower gastrointestinal endoscopies and observed the lesion using white light imaging(WLI),TXI,CE,and TXI+CE modalities.Indigo carmine dye was used for CE.Three expert endoscopists rated the visibility of the margin and surface patterns in four ranks,from 1 to 4.The primary outcomes were the average visibility scores for the margin and surface patterns based on the WLI,TXI,CE,and TXI+CE observations.Visibility scores between the four modalities were compared by the Kruskal-Wallis and Dunn tests.RESULTS A total of 48 patients with 81 polyps were assessed.The histological subtypes included 50 tubular adenomas,16 hyperplastic polyps,and 15 sessile serrated lesions.The visibility scores for the margins based on WLI,TXI,CE,and TXI+CE were 2.44±0.93,2.90±0.93,3.37±0.74,and 3.75±0.49,respectively.The visibility scores for the surface based on WLI,TXI,CE,and TXI+CE were 2.25±0.80,2.84±0.84,3.12±0.72,and 3.51±0.60,respectively.The visibility scores for the detection and surface on TXI were significantly lower than that on CE but higher than that on WLI(P<0.001).The visibility scores for the margin and surface on TXI+CE were significantly higher than those on CE(P<0.001).In the sub-analysis of adenomas,the visibility for the margin and surface on TXI+CE was significantly better than that on WLI,TXI,and CE(P<0.001).In the sub-analysis of serrated polyps,the visibility for the margin and surface on TXI+CE was also significantly better than that on WLI,TXI,and CE(P<0.001).CONCLUSION TXI+CE enhanced the visibility of the margin and surface compared to WLI,TXI,and CE for colorectal lesions.
文摘BACKGROUND Olympus Corporation has developed texture and color enhancement imaging(TXI)as a novel image-enhancing endoscopic technique.AIM To investigate the effectiveness of TXI in identifying colorectal adenomas using magnifying observation.METHODS Colorectal adenomas were observed by magnified endoscopy using white light imaging(WLI),TXI,narrow band imaging(NBI),and chromoendoscopy(CE).This study adopted mode 1 of TXI.Adenomas were confirmed by histological examination.TXI visibility was compared with the visibility of WLI,NBI,and CE for tumor margin,and vessel and surface patterns of the Japan NBI expert team(JNET)classification.Three expert endoscopists and three non-expert endoscopists evaluated the visibility scores,which were classified as 1,2,3,and 4.RESULTS Sixty-one consecutive adenomas were evaluated.The visibility score for tumor margin of TXI(3.47±0.79)was significantly higher than that of WLI(2.86±1.02,P<0.001),but lower than that of NBI(3.76±0.52,P<0.001),regardless of the endoscopist’s expertise.TXI(3.05±0.79)had a higher visibility score for the vessel pattern of JNET classification than WLI(2.17±0.90,P<0.001)and CE(2.47±0.87,P<0.001),but lower visibility score than NBI(3.79±0.47,P<0.001),regardless of the experience of endoscopists.For the visibility score for the surface pattern of JNET classification,TXI(2.89±0.85)was superior to WLI(1.95±0.79,P<0.01)and CE(2.75±0.90,P=0.002),but inferior to NBI(3.67±0.55,P<0.001).CONCLUSION TXI provided higher visibility than WLI,lower than NBI,and comparable to or higher than CE in the magnified observation of colorectal adenomas.
基金The National Natural Science Foundation of China under contract Nos 61702455,61672462 and 61902350the Natural Science Foundation of Zhejiang Province,China under contract No.LY20F020025。
文摘Texture-based visualization method is a common method in the visualization of vector field data.Aiming at adding color mapping to the texture of ocean vector field and solving the ambiguity of vector direction in texture image,a new color texture enhancement algorithm based on the Line Integral Convolution(LIC)for the vector field data is proposed,which combines the HSV color mapping and cumulative distribution function calculation of vector field data.This algorithm can be summarized as follows:firstly,the vector field data is convoluted twice by line integration to get the gray texture image.Secondly,the method of mapping vector data to each component of the HSV color space is established.And then,the vector field data is mapped into HSV color space and converted from HSV to RGB values to get the color image.Thirdly,the cumulative distribution function of the RGB color components of the gray texture image and the color image is constructed to enhance the gray texture and RGB color values.Finally,both the gray texture image and the color image are fused to get the color texture.The experimental results show that the proposed LIC color texture enhancement algorithm is capable of generating a better display of vector field data.Furthermore,the ambiguity of vector direction in the texture images is solved and the direction information of the vector field is expressed more accurately.
文摘Texture and color enhancement imaging(TXI)has been developed as a novel image-enhancing endoscopy.However,the effectiveness of TXI detecting adenomas is inferior to narrow band imaging.Thus,future studies will need to focus on investigating the feasibility of such combination in clinical settings in order to provide patients with more accurate diagnoses.