A reconstruction method is proposed for the polyurethane foam and then a complete numerical method is developed to predict the effective thermal conductivity of the polyurethane foam. The finite volume method is appli...A reconstruction method is proposed for the polyurethane foam and then a complete numerical method is developed to predict the effective thermal conductivity of the polyurethane foam. The finite volume method is applied to solve the 2D heterogeneous pure conduction. The lattice Boltzmann method is adopted to solve the 1D homogenous radiative transfer equation rather than Rosseland approximation equation. The lattice Boltzmann method is then adopted to solve 1D homogeneous conduction-radiation energy transport equation considering the combined effect of conduction and radiation. To validate the accuracy of the present method, the hot disk method is adopted to measure the effective thermal conductivity of the polyurethane foams at different temperature. The numerical results agree well with the experimental data. Then, the influences of temperature, porosity and cell size on the effective thermal conductivity of the polyurethane foam are investigated. The results show that the effective thermal conductivity of the polyurethane foams increases with temperature; and the effective thermal conductivity of the polyurethane foams decreases with increasing porosity while increases with the cell size.展开更多
The efficiency and precision of parameter calibration in discrete element method (DEM) are not satisfactory, and parameter calibration for granular heat transfer is rarely involved. Accordingly, parameter calibratio...The efficiency and precision of parameter calibration in discrete element method (DEM) are not satisfactory, and parameter calibration for granular heat transfer is rarely involved. Accordingly, parameter calibration for granular heat transfer with the DEM is studied. The heat transfer in granular assemblies is simulated with DEM, and the effective thermal conductivity (ETC) of these granular assemblies is measured with the transient method in simulations. The measurement testbed is designed to test the ETC of the granular assemblies under normal pressure and a vacuum based on the steady method. Central composite design (CCD) is used to simulate the impact of the DEM parameters on the ETC of granular assemblies, and the heat transfer parameters are calibrated and compared with experimental data. The results show that, within the scope of the considered parameters, the ETC of the granular assemblies increases with an increasing particle thermal conductivity and decreases with an increasing particle shear modulus and particle diameter. The particle thermal conductivity has the greatest impact on the ETC of granular assemblies followed by the particle shear modulus and then the particle diameter. The calibration results show good agreement with the experimental results. The error is less than 4%, which is within a reasonable range for the scope of the CCD parameters. The proposed research provides high efficiency and high accuracy parameter calibration for granular heat transfer in DEM.展开更多
基金Funded by Key Project of International Joint Research of National Natural Science Foundation of China(No.51320105004)
文摘A reconstruction method is proposed for the polyurethane foam and then a complete numerical method is developed to predict the effective thermal conductivity of the polyurethane foam. The finite volume method is applied to solve the 2D heterogeneous pure conduction. The lattice Boltzmann method is adopted to solve the 1D homogenous radiative transfer equation rather than Rosseland approximation equation. The lattice Boltzmann method is then adopted to solve 1D homogeneous conduction-radiation energy transport equation considering the combined effect of conduction and radiation. To validate the accuracy of the present method, the hot disk method is adopted to measure the effective thermal conductivity of the polyurethane foams at different temperature. The numerical results agree well with the experimental data. Then, the influences of temperature, porosity and cell size on the effective thermal conductivity of the polyurethane foam are investigated. The results show that the effective thermal conductivity of the polyurethane foams increases with temperature; and the effective thermal conductivity of the polyurethane foams decreases with increasing porosity while increases with the cell size.
基金Supported by National Natural Science Foundation of China(Grant Nos.51105092,61403106)International Science and Technology Cooperation Program of China(Grant No.2014DFR50250)the 111 Project,China(Grant No.B07018)
文摘The efficiency and precision of parameter calibration in discrete element method (DEM) are not satisfactory, and parameter calibration for granular heat transfer is rarely involved. Accordingly, parameter calibration for granular heat transfer with the DEM is studied. The heat transfer in granular assemblies is simulated with DEM, and the effective thermal conductivity (ETC) of these granular assemblies is measured with the transient method in simulations. The measurement testbed is designed to test the ETC of the granular assemblies under normal pressure and a vacuum based on the steady method. Central composite design (CCD) is used to simulate the impact of the DEM parameters on the ETC of granular assemblies, and the heat transfer parameters are calibrated and compared with experimental data. The results show that, within the scope of the considered parameters, the ETC of the granular assemblies increases with an increasing particle thermal conductivity and decreases with an increasing particle shear modulus and particle diameter. The particle thermal conductivity has the greatest impact on the ETC of granular assemblies followed by the particle shear modulus and then the particle diameter. The calibration results show good agreement with the experimental results. The error is less than 4%, which is within a reasonable range for the scope of the CCD parameters. The proposed research provides high efficiency and high accuracy parameter calibration for granular heat transfer in DEM.