Control of Doubly Fed Induction Generator under Unbalanced Voltages for Reduction of Torque Pulsation
1
作者 S. Wangsathitwong S. Sirisumrannukul +1 位作者 S. Chatratana W. Deleroi 《Journal of Energy and Power Engineering》 2011年第3期243-251,共9页
The unbalanced voltages cause negative effects on the doubly fed induction generator (DFIG) sucn as torque pulsation,and increased stator current. Based on the symmetrical component theory, the torque pulsation is t... The unbalanced voltages cause negative effects on the doubly fed induction generator (DFIG) sucn as torque pulsation,and increased stator current. Based on the symmetrical component theory, the torque pulsation is the consequence of the interaction of stator and rotor currents of different sequences. This paper presents a control technique to reduce the effect of unbalanced voltages on the DFIG in wind energy conversion systems. The negative sequence stator voltage is derived from the unbalanced three phase stator voltages. The compensated rotor voltage in terms of the derived negative sequence stator voltage and slip which minimizes the negative stator and rotor currents is proposed. The results from the simulation of control system with steady state model and dynamic model of the DFIG show that additional control loop with compensated voltage can significantly reduce torque and reactive power pulsations. 展开更多
关键词 Doubly fed induction generator (DFIG) unbalanced voltages symmetrical components.
下载PDF
Dual-negative-objective Coordinated Control of Brushless Doubly Fed Induction Generator under Unbalanced Grid Voltage
2
作者 Ming Cheng Zheng Cao Xiaoming Yan 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第3期347-355,共9页
This article proposes a dual-negative-objective coordinated control strategy for brushless doubly fed induction generator(BDFIG)based wind power generation system under unbalanced grid voltage.To alleviate the mechani... This article proposes a dual-negative-objective coordinated control strategy for brushless doubly fed induction generator(BDFIG)based wind power generation system under unbalanced grid voltage.To alleviate the mechanical stress and impaction on rotating shaft,the negative control objective(NCO)of machine side converter(MSC)is set to suppress the ripple of electromagnetic torque.While the NCO of grid side converter(GSC)is selected to suppress the oscillation of total output active power or the unbalanced degree of total output current for BDFIG generation system.In comparison with traditional single converter control scheme of the MSC or GSC,dual NCOs can be satisfied at the same time due to the enlarged freedom degree in the proposed improved coordinated control system for back-toback converters.The effectiveness of proposed control strategy is validated by simulation and experimental results on a dual-cagerotor BDFIG(DCR-BDFIG)prototype. 展开更多
关键词 Brushless doubly fed induction generator Dual-negative-objective Freedom degree unbalanced grid voltage
下载PDF
Enhanced control of DFIG-used back-to-back PWM VSC under unbalanced grid voltage conditions 被引量:20
3
作者 HU Jia-bing HE Yi-kang NIAN Heng 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2007年第8期1330-1339,共10页
This paper presents a unified positive-and negative-sequence dual-dq dynamic model of wind-turbine driven doubly-fed induction generator(DFIG) under unbalanced grid voltage conditions. Strategies for enhanced control ... This paper presents a unified positive-and negative-sequence dual-dq dynamic model of wind-turbine driven doubly-fed induction generator(DFIG) under unbalanced grid voltage conditions. Strategies for enhanced control and operation of a DFIG-used back-to-back(BTB) PWM voltage source converter(VSC) are proposed. The modified control design for the grid-side converter in the stationary αβ frames diminishes the amplitude of DC-link voltage ripples of twice the grid frequency,and the two proposed control targets for the rotor-side converter are alternatively achieved,which,as a result,improve the fault-ride through(FRT) capability of the DFIG based wind power generation systems during unbalanced network supply. A complete unbalanced control scheme with both grid-and rotor-side converters included is designed. Finally,simulation was carried out on a 1.5 MW wind-turbine driven DFIG system and the validity of the developed unified model and the feasibility of the proposed control strategies are all confirmed by the simulated results. 展开更多
关键词 unbalanced grid voltage Doubly-fed induction generator (DFIG) Back-to-back (BTB) Fault-ride through (FRT) voltage source converter (VSC)
下载PDF
Novel control scheme for 3-phase PWM current-source converters under unbalanced source voltage conditions 被引量:1
4
作者 李玉玲 楼珍丽 张仲超 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2006年第2期263-268,共6页
Under unbalanced source voltage supply, considerable output second harmonics and input low-order harmonics in 3-phase PWM current-source converters (PWM-CSC) are generated. This paper proposes a new deadbeat controlle... Under unbalanced source voltage supply, considerable output second harmonics and input low-order harmonics in 3-phase PWM current-source converters (PWM-CSC) are generated. This paper proposes a new deadbeat controller based on compensation for unbalanced source voltage and current. With the proposed scheme, the second harmonics of the output current are eliminated and low-order harmonics of the source current are reduced effectively. Simulation and experimental results con- firmed the feasibility of the proposed method. 展开更多
关键词 PWM current-source converters (PWM-CSC) unbalanced source voltage conditions Deadbeat control
下载PDF
Adaptive rotor current control for wind-turbine driven DFIG using resonant controllers in a rotor rotating reference frame 被引量:3
5
作者 Jia-bing HU Yi-kang HE Hong-sheng WANG 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2008年第2期149-155,共7页
This paper proposes an adaptive rotor current controller for doubly-fed induction generator (DFIG), which consists of a proportional (P) controller and two harmonic resonant (R) controllers implemented in the rotor ro... This paper proposes an adaptive rotor current controller for doubly-fed induction generator (DFIG), which consists of a proportional (P) controller and two harmonic resonant (R) controllers implemented in the rotor rotating reference frame. The two resonant controllers are tuned at slip frequencies ωslip+ and ωslip-, respectively. As a result, the positive- and negative-sequence components of the rotor current are fully regulated by the PR controller without involving the positive- and negative-sequence decomposition, which in effect improves the fault ride-through (FRT) capability of the DFIG-based wind power generation system during the period of large transient grid voltage unbalance. Correctness of the theoretical analysis and feasibility of the proposed unbalanced control scheme are validated by simulation on a 1.5-MW DFIG wind power generation system. 展开更多
关键词 unbalanced grid voltage Doubly-fed induction generator (DFIG) Proportional plus Resonant (PR) controller Faultride-through (FRT)
下载PDF
Multiple target implementation for a doubly fed induction generator based on direct power control under unbalanced and distorted grid voltage 被引量:2
6
作者 Heng NIAN Yi-peng SONG 《Frontiers of Information Technology & Electronic Engineering》 SCIE EI CSCD 2015年第4期321-334,共14页
This paper presents a multiple target implementation technique for a doubly fed induction generator (DFIG) under unbalanced and distorted grid voltage based on direct power control (DPC). Based on the mathematical... This paper presents a multiple target implementation technique for a doubly fed induction generator (DFIG) under unbalanced and distorted grid voltage based on direct power control (DPC). Based on the mathematical model of DFIG under unbalanced and distorted voltage, the proportional and integral (PI) regulator is adopted to regulate the DFIG average active and reactive powers, while the vector P1 (VPI) resonant regulator is used to achieve three alternative control targets: (1) balanced and sinusoidal stator current; (2) smooth instantaneous stator active and reactive powers; (3) smooth electromagnetic torque and instantaneous stator reactive power. The major advantage of the proposed control strategy over the conventional method is that neither negative and harmonic sequence decomposition of grid voltage nor complicated control reference calculation is required. The insensitivity of the proposed control strategy to DFIG parameter deviation is analyzed. Finally, the DFIG experimental system is developed to validate the availability of the proposed DPC strategy under unbalanced and distorted grid voltage, 展开更多
关键词 Direct power control Doubly fed induction generator unbalanced and distorted grid voltage Vector proportionaland integral resonant regulator Parameter deviation
原文传递
Detection Scheme of Positive Sequence Components Based on Operation Period Delay Filter 被引量:1
7
作者 Liwei Du Liansong Xiong +3 位作者 Mingxian Li Zhen Tang Liancheng Xiu Xun Ma 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2023年第1期235-243,共9页
Fast and accurate acquisition of positive sequence components of unbalanced grid voltage is an essential requirement to ensure the safety operation of the grid-connected inverter.To improve the extraction speed of pos... Fast and accurate acquisition of positive sequence components of unbalanced grid voltage is an essential requirement to ensure the safety operation of the grid-connected inverter.To improve the extraction speed of positive sequence components of unbalanced voltage,this study proposes a sampling period delay filter(SPDF)to quickly separate positive and negative sequence components by delaying two sampling periods of grid voltage in dq frame.With the SPDF method,only one coordinate transformation is required and the computational burden can be reduced apparently.Then,the noise immunity performance of the proposed SPDF algorithm is investigated;and the corresponding solution,operation period delay filter(OPDF),can guarantee the desired fast response performance under the premise of limiting the amplified noise within the acceptable range.Finally,the feasibility and priority of the above two algorithms have been verified by the simulation and experimental results. 展开更多