In this paper, four kinds of polymethacrylates(PMAs) used as multifunctional additives were synthesized from quaternary C1—C14 methacrylate, among which sample 4 exhibited relatively better performance. According to ...In this paper, four kinds of polymethacrylates(PMAs) used as multifunctional additives were synthesized from quaternary C1—C14 methacrylate, among which sample 4 exhibited relatively better performance. According to the methacrylate ratio of sample 4, the optimized reaction conditions of PMA were explored by orthogonal experiments comprising 4 factors and 3 levels, and the optimized reaction conditions covered an initiator dosage of 0.8 %, a molecular weight regulator dosage of 0.4%, a reaction temperature of 95 ℃ and a reaction time of 8.5 h. When the optimized PMA samples were used to formulate the 75W/90 automotive gear base oil, they exhibited improved shear stability and good low temperature property. In comparison with foreign commercial polymethacrylate GP, the optimized PMA samples exhibited better thickening ability, similar shear stability and slightly weak low temperature property, with their performance being the same as GP's on the whole. The slight difference in the performance between the optimized PMA and GP was attributed to the difference of chain length of copolymers and the distribution of relative molecular mass between them.展开更多
Measurements of neutron count rate (0.025 eV to 10 MeV) at ground level were performed with a single free (He-3) tube detectorthat is located near ground level in Aeronautical Institute of Technology (ITA) Silo ...Measurements of neutron count rate (0.025 eV to 10 MeV) at ground level were performed with a single free (He-3) tube detectorthat is located near ground level in Aeronautical Institute of Technology (ITA) Silo Jos6 dos Campos, SP, Brazil. The data were collected uninterruptedly since February 28, 2016 to March 11, 2016. Based on the analysis of data obtained in this period, was possible to observe the occurrence of events, backscattering for example,with significant increases in the neutron count rate during about 3 days of steady rain for all nearby regions. These events seem to be correlated with changes in local weather conditions such as cloud coverage or rain-precipitation of weak intensity. It was reported that the non-observation of a single event seems to be an indicative of the production of a burst of neutrons by a lightning discharge near the detector. Some explanations about the increasing of low energy neutrons are suggested in this article.展开更多
This paper presents the investigation of the effects of suction side squealer tip on the performance of an axial compressor. The experiment is carded out in a single-stage large-scale low-speed compressor. The investi...This paper presents the investigation of the effects of suction side squealer tip on the performance of an axial compressor. The experiment is carded out in a single-stage large-scale low-speed compressor. The investigated tip geometries include fiat tip as the baseline and suction side squealer tip. The tip clearance of the baseline is 0.5% of the blade span. The static pressure rise characteristic curves of both the rotor and the stage are measured. The flow field at the exit of the rotor is measured by a 5-hole probe under design and off-design conditions. The static pressure on the endwall of the rotor passage is also obtained. The results show that the pressure rise characteristic curves obtained by measuring the pressure on the end wall are almost unchanged by using the suction side squealer tip. The measuring results of the 5-hole probe show the static pressure and the total pressure in tip region is slightly greater than that of the flat tip at the design condition at the exit of the rotor. It also leads to greater averaged static pressure rise and total pressure. At the near stall condition, the averaged static pressure and total pressure is lower than the baseline which is related to the redistribution of the blade load caused by the suction side squealer tip.展开更多
文摘In this paper, four kinds of polymethacrylates(PMAs) used as multifunctional additives were synthesized from quaternary C1—C14 methacrylate, among which sample 4 exhibited relatively better performance. According to the methacrylate ratio of sample 4, the optimized reaction conditions of PMA were explored by orthogonal experiments comprising 4 factors and 3 levels, and the optimized reaction conditions covered an initiator dosage of 0.8 %, a molecular weight regulator dosage of 0.4%, a reaction temperature of 95 ℃ and a reaction time of 8.5 h. When the optimized PMA samples were used to formulate the 75W/90 automotive gear base oil, they exhibited improved shear stability and good low temperature property. In comparison with foreign commercial polymethacrylate GP, the optimized PMA samples exhibited better thickening ability, similar shear stability and slightly weak low temperature property, with their performance being the same as GP's on the whole. The slight difference in the performance between the optimized PMA and GP was attributed to the difference of chain length of copolymers and the distribution of relative molecular mass between them.
文摘Measurements of neutron count rate (0.025 eV to 10 MeV) at ground level were performed with a single free (He-3) tube detectorthat is located near ground level in Aeronautical Institute of Technology (ITA) Silo Jos6 dos Campos, SP, Brazil. The data were collected uninterruptedly since February 28, 2016 to March 11, 2016. Based on the analysis of data obtained in this period, was possible to observe the occurrence of events, backscattering for example,with significant increases in the neutron count rate during about 3 days of steady rain for all nearby regions. These events seem to be correlated with changes in local weather conditions such as cloud coverage or rain-precipitation of weak intensity. It was reported that the non-observation of a single event seems to be an indicative of the production of a burst of neutrons by a lightning discharge near the detector. Some explanations about the increasing of low energy neutrons are suggested in this article.
基金funded by the National Natural Science Foundation of China,Grant No.51161130525 and 51136003supported by the 111 Project,No.B07009
文摘This paper presents the investigation of the effects of suction side squealer tip on the performance of an axial compressor. The experiment is carded out in a single-stage large-scale low-speed compressor. The investigated tip geometries include fiat tip as the baseline and suction side squealer tip. The tip clearance of the baseline is 0.5% of the blade span. The static pressure rise characteristic curves of both the rotor and the stage are measured. The flow field at the exit of the rotor is measured by a 5-hole probe under design and off-design conditions. The static pressure on the endwall of the rotor passage is also obtained. The results show that the pressure rise characteristic curves obtained by measuring the pressure on the end wall are almost unchanged by using the suction side squealer tip. The measuring results of the 5-hole probe show the static pressure and the total pressure in tip region is slightly greater than that of the flat tip at the design condition at the exit of the rotor. It also leads to greater averaged static pressure rise and total pressure. At the near stall condition, the averaged static pressure and total pressure is lower than the baseline which is related to the redistribution of the blade load caused by the suction side squealer tip.