A novel laser ranging system using chaotic laser as probe light source is designed and presented.The system is made up of five components:chaotic light source,transmitter,receiver,data acquisition unit and data proces...A novel laser ranging system using chaotic laser as probe light source is designed and presented.The system is made up of five components:chaotic light source,transmitter,receiver,data acquisition unit and data processing unit.Chaotic light is generated by an 808 nm,500 mW,single-mode laser diode with optical feedback cavity.Single target detection and multi-target detection are experimentally realized by correlating the chaotic reference light and the reflected or backscattered probe light.The performances,including the resolution of 18 cm within at least 130 m range and the sensitivity of-20 dB,are achieved and analyzed.展开更多
A seismometer data acquisition unit has been used in the Changping seismic station to record the output of a strainmeter. The output of a strainmeter was sampled at a rate of l00/sec by seismometer acquisition from th...A seismometer data acquisition unit has been used in the Changping seismic station to record the output of a strainmeter. The output of a strainmeter was sampled at a rate of l00/sec by seismometer acquisition from the original rate of 1 per minute. Plenty of high frequency sampled data was recorded. The minute value curve calculated from the seismometer acquisition are consistent with that of the original data sampled by the strain acquisition system. More complete waveforms were recorded with a higher sampling rate, and seismic phase parameters calculated by using higher sampling rate strain seismic waves are also in consistency with the results of its predecessors. Spectra of the strain seismic waves are compared with that of seismic waves recorded by a seismometer in the Shisanling seismic station, and their trends are almost the same. Besides, some lower frequency components still exist in strain seismic waves.展开更多
ADCS (automated data collection system) is the element of MDMS (meter data management system) and a module in charge of collecting the data from DCUs (data collection units) or meters in AMI (advanced metering ...ADCS (automated data collection system) is the element of MDMS (meter data management system) and a module in charge of collecting the data from DCUs (data collection units) or meters in AMI (advanced metering infrastructure)-based interactive two-way communications infrastructure. In this study, ADCS's functions for K-AMI (Korean Advanced Metering Infrastructure) were analyzed and the logical design of ADCS which is suitable for the requirements was suggested. A massive data collection and management functions was defined as very important functions of ADCS to meet optimal data processing mechanism. ADCS was designed for support about the fuctions of data collection and transfer, large capacity data processing, interactive services, parallel processing, etc.. Also, ADCS has roles of protocols exchange and gateway for service support in addition to data collection in AMI environment.展开更多
A new method of measuring gas pressure in vacuum insulation panels(VIPs)is reported in this study,which provides a fast and efficient quality control option of production.Although there are different methods of measur...A new method of measuring gas pressure in vacuum insulation panels(VIPs)is reported in this study,which provides a fast and efficient quality control option of production.Although there are different methods of measuring gas pressure for VIPs,connecting an internal measurement gauge to external data acquisition units is problematic.The thin high barrier film covering the panel’s core usually prevents external electrical wires or mechanical devices being connected to the inside of the VIPs.To solve this problem,a micro capacitive pressure sensor with 0 to 250 Pa detection range is developed to detect the vacuum pressure.The sensor has high linearity and a sensitivity of 10 mV/Pa.Moreover,through the communication mode study,an ultrasound communications system for VIPs is designed.It shows from operation that this system is stable and reliable,and quick for communication speed.This new method enables the quality detection of VIPs to be completed within 1 second.The minimum detectable pressure of VIPs is below 1 Pa,and the measurement error can be controlled around 5%.展开更多
基金supported by the National Natural Science Foundation of China(No.60777041and No.60908014)
文摘A novel laser ranging system using chaotic laser as probe light source is designed and presented.The system is made up of five components:chaotic light source,transmitter,receiver,data acquisition unit and data processing unit.Chaotic light is generated by an 808 nm,500 mW,single-mode laser diode with optical feedback cavity.Single target detection and multi-target detection are experimentally realized by correlating the chaotic reference light and the reflected or backscattered probe light.The performances,including the resolution of 18 cm within at least 130 m range and the sensitivity of-20 dB,are achieved and analyzed.
基金sponsored by Central Public-interest Scientific Institution Basic Research Fund of Institute of Crustal Dynamics,CEA(ZDJ2008-40,ZDJ2010-15)
文摘A seismometer data acquisition unit has been used in the Changping seismic station to record the output of a strainmeter. The output of a strainmeter was sampled at a rate of l00/sec by seismometer acquisition from the original rate of 1 per minute. Plenty of high frequency sampled data was recorded. The minute value curve calculated from the seismometer acquisition are consistent with that of the original data sampled by the strain acquisition system. More complete waveforms were recorded with a higher sampling rate, and seismic phase parameters calculated by using higher sampling rate strain seismic waves are also in consistency with the results of its predecessors. Spectra of the strain seismic waves are compared with that of seismic waves recorded by a seismometer in the Shisanling seismic station, and their trends are almost the same. Besides, some lower frequency components still exist in strain seismic waves.
文摘ADCS (automated data collection system) is the element of MDMS (meter data management system) and a module in charge of collecting the data from DCUs (data collection units) or meters in AMI (advanced metering infrastructure)-based interactive two-way communications infrastructure. In this study, ADCS's functions for K-AMI (Korean Advanced Metering Infrastructure) were analyzed and the logical design of ADCS which is suitable for the requirements was suggested. A massive data collection and management functions was defined as very important functions of ADCS to meet optimal data processing mechanism. ADCS was designed for support about the fuctions of data collection and transfer, large capacity data processing, interactive services, parallel processing, etc.. Also, ADCS has roles of protocols exchange and gateway for service support in addition to data collection in AMI environment.
基金supported by the Science and Technology Projects of Fujian Province of China(Grant No.2010H6025)Science and Technology Projects of Xiamen City of China(Grant No.3502Z20103012)
文摘A new method of measuring gas pressure in vacuum insulation panels(VIPs)is reported in this study,which provides a fast and efficient quality control option of production.Although there are different methods of measuring gas pressure for VIPs,connecting an internal measurement gauge to external data acquisition units is problematic.The thin high barrier film covering the panel’s core usually prevents external electrical wires or mechanical devices being connected to the inside of the VIPs.To solve this problem,a micro capacitive pressure sensor with 0 to 250 Pa detection range is developed to detect the vacuum pressure.The sensor has high linearity and a sensitivity of 10 mV/Pa.Moreover,through the communication mode study,an ultrasound communications system for VIPs is designed.It shows from operation that this system is stable and reliable,and quick for communication speed.This new method enables the quality detection of VIPs to be completed within 1 second.The minimum detectable pressure of VIPs is below 1 Pa,and the measurement error can be controlled around 5%.