The design and assembly of environmental monitoring and control system for large-scale pig house with fermentation bed helped to solve the problem of environmental automatic control in piggery.The sensors would monito...The design and assembly of environmental monitoring and control system for large-scale pig house with fermentation bed helped to solve the problem of environmental automatic control in piggery.The sensors would monitor the temperature,humidity,light,wind direction,wind speed,CO2,NH3and other parameters.On-line real-time data collection was achieved.The expert system was constructed to control the temperature in piggery below 30℃,to control the air and mattress humidities higher than 65%.Under the conditions of different season or different wind speed,even in day and night,the control actuators were different.The actuators included fanning wet curtain,lighting,micro spraying,spraying,propeller fan,electric aluminum alloy shutter and spraying systems on the roof.The actuators were integrated,and they control the piggery environment simultaneously.The system also designed the remote video monitor interface,parameter-monitoring curved interface and operation interface,which provided a good man-machine interface.展开更多
An approach is described that has been developed for auxiliary monitoring of technical condition of hydropower plant dams. It is based on analysis of changes in dynamic characteristics of dams obtained by an automated...An approach is described that has been developed for auxiliary monitoring of technical condition of hydropower plant dams. It is based on analysis of changes in dynamic characteristics of dams obtained by an automated monitoring and earthquake registration system that records microseismic vibrations of structures. The configuration of the system as well as the results of seismometric monitoring of the dam of Krasnoyarsk hydroelectric power plant are described. To study behavior of the dam under normal and extreme loads it was proposed to develop a model of the dam with the use of the finite element method.展开更多
This paper puts forward the LPM fault diagnosis method in the view of the important purpose of on-line monitoring and fault diagnosis for hoister brake system. The feasibility of the two diagnosis methods are proved i...This paper puts forward the LPM fault diagnosis method in the view of the important purpose of on-line monitoring and fault diagnosis for hoister brake system. The feasibility of the two diagnosis methods are proved in theories; two methods are proved about feasibility and reliability through testing. Two methods are manifestoed that they can undertake the on-line monitoring and fault diagnosis for hoister brake system with satisfied effect.展开更多
基金Supported by Special Fund for Agro-scientific Research in the Public Interest(201303094)International Science and Technology Cooperation Project of China(2012DFA31120)National Key Technology Research and Development Program(2012BAD14B15)
文摘The design and assembly of environmental monitoring and control system for large-scale pig house with fermentation bed helped to solve the problem of environmental automatic control in piggery.The sensors would monitor the temperature,humidity,light,wind direction,wind speed,CO2,NH3and other parameters.On-line real-time data collection was achieved.The expert system was constructed to control the temperature in piggery below 30℃,to control the air and mattress humidities higher than 65%.Under the conditions of different season or different wind speed,even in day and night,the control actuators were different.The actuators included fanning wet curtain,lighting,micro spraying,spraying,propeller fan,electric aluminum alloy shutter and spraying systems on the roof.The actuators were integrated,and they control the piggery environment simultaneously.The system also designed the remote video monitor interface,parameter-monitoring curved interface and operation interface,which provided a good man-machine interface.
文摘An approach is described that has been developed for auxiliary monitoring of technical condition of hydropower plant dams. It is based on analysis of changes in dynamic characteristics of dams obtained by an automated monitoring and earthquake registration system that records microseismic vibrations of structures. The configuration of the system as well as the results of seismometric monitoring of the dam of Krasnoyarsk hydroelectric power plant are described. To study behavior of the dam under normal and extreme loads it was proposed to develop a model of the dam with the use of the finite element method.
文摘This paper puts forward the LPM fault diagnosis method in the view of the important purpose of on-line monitoring and fault diagnosis for hoister brake system. The feasibility of the two diagnosis methods are proved in theories; two methods are proved about feasibility and reliability through testing. Two methods are manifestoed that they can undertake the on-line monitoring and fault diagnosis for hoister brake system with satisfied effect.