某轮,CSBC台湾高雄总厂1988年建造。辅锅炉组合式立管水管锅炉(Composite System Vertical Water Tube Boiler).Osaka Boiler MFG Co.,Ltd.产品,如图1所示.锅炉水空间直径(OD)1824mm,燃油加热部分直立水管175支×Ф63....某轮,CSBC台湾高雄总厂1988年建造。辅锅炉组合式立管水管锅炉(Composite System Vertical Water Tube Boiler).Osaka Boiler MFG Co.,Ltd.产品,如图1所示.锅炉水空间直径(OD)1824mm,燃油加热部分直立水管175支×Ф63.5mm×3.6mm(壁厚)×438mm(长),上层主机废气加热部分直立水管544支×Ф51mm×3.6mm(壁厚)×2058mm(长)。展开更多
The structural relaxation of a cluster containing 55 atoms at elevated temperatures is simulated by molecular dynamics. The interatomic interactions are given by using the embedded atom method (EAM) potential. By de...The structural relaxation of a cluster containing 55 atoms at elevated temperatures is simulated by molecular dynamics. The interatomic interactions are given by using the embedded atom method (EAM) potential. By decomposing the peaks of the radial distribution functions (RDFs) according to the pair analysis technique, the local structural patterns are identified for this cluster. During increasing temperature, structural changes of different shells determined by atom density profiles result in an abrupt increase in internal energy. The simulations show how local structural changes can strongly cause internal energy to change accordingly.展开更多
The restoration mechanisms for static recrystallization of work-hardened austenite were investigated by using double-pass compression tests performed on medium-carbon steel containing chromium and molybdenum. The soft...The restoration mechanisms for static recrystallization of work-hardened austenite were investigated by using double-pass compression tests performed on medium-carbon steel containing chromium and molybdenum. The softening fraction was defined by 2% offset method. The results show that Avrami exponent of about 0.21 is insensitive to deformation temperature, indicating that the action of steel grade should be considered. The time of 50% recrystallization (t0.5) decreases noteworthily with the increase of deformation temperature. Apparent activation energy for static recrystallization of 195 kJ/mol, which is close to that of vanadium microalloyed steel, is obtained by calculating. The increasing trend of the driving force for recrystallization is opposite to that of the deformation temperature, which is attributed to the number of operative slip system increasing as temperature increasing.展开更多
A numerical study based on the finite volume method has been performed to study the three-dimension natural convection in a parallelogrammic top side opened cavity filled nanofluid with partially heated square at the ...A numerical study based on the finite volume method has been performed to study the three-dimension natural convection in a parallelogrammic top side opened cavity filled nanofluid with partially heated square at the bottom side.Results are obtained for different governing parameters such as nanoparticle concentration (φ) from 0 to 0.05,inclination angle of the back and front walls (α) from 5° to 75°,Rayleigh number from 10^3 to 10^5,and length of heater changer from 0.1 to 1.The main finding from the obtained result showed that the inclination angle and nanoparticle volume fraction affect the flow structure and enhance the heat transfer.展开更多
A multi-heat pipe is a device for heat transmission. It is composed of a heating section, a cooling section and an adiabatic section. The heating and cooling sections are the same and both are connected by four circul...A multi-heat pipe is a device for heat transmission. It is composed of a heating section, a cooling section and an adiabatic section. The heating and cooling sections are the same and both are connected by four circular parallel tubes. This experimental study is performed to investigate heat transfer performance of a multi-heat pipe in the vertical orientation using pure water and GO (graphene oxide)/water nanofluid. GO/water nanofluids were synthesized by the modified Hummers method with 0.05%, 0.1%, 0.15%, and 0.2% volume concentrations. The thermal performance has been investigated with varying heat flux in the range of 10-30 W and 100% fill charge ratio. Wall temperature, thermal resistance, and heat transfer coefficient of the heat pipe are measured and compared with those for the heat pipe using pure water. The experimental results show that the evaporator wall temperature with GO nanofluid is lower than that of the base fluid. Also, the heat pipe that charged with nanofluids showed lower thermal resistance compared with pure water. Heat transfer enhancement is caused by suspended nanoparticles and is pronounced with the increase in particle volume fraction.展开更多
文摘某轮,CSBC台湾高雄总厂1988年建造。辅锅炉组合式立管水管锅炉(Composite System Vertical Water Tube Boiler).Osaka Boiler MFG Co.,Ltd.产品,如图1所示.锅炉水空间直径(OD)1824mm,燃油加热部分直立水管175支×Ф63.5mm×3.6mm(壁厚)×438mm(长),上层主机废气加热部分直立水管544支×Ф51mm×3.6mm(壁厚)×2058mm(长)。
基金Project supported by the National Natural Science Foundation of China (Grant No 50572013) and the National Basic Research Program of China (Grant No 2006CB605103). Corresponding author.
文摘The structural relaxation of a cluster containing 55 atoms at elevated temperatures is simulated by molecular dynamics. The interatomic interactions are given by using the embedded atom method (EAM) potential. By decomposing the peaks of the radial distribution functions (RDFs) according to the pair analysis technique, the local structural patterns are identified for this cluster. During increasing temperature, structural changes of different shells determined by atom density profiles result in an abrupt increase in internal energy. The simulations show how local structural changes can strongly cause internal energy to change accordingly.
文摘The restoration mechanisms for static recrystallization of work-hardened austenite were investigated by using double-pass compression tests performed on medium-carbon steel containing chromium and molybdenum. The softening fraction was defined by 2% offset method. The results show that Avrami exponent of about 0.21 is insensitive to deformation temperature, indicating that the action of steel grade should be considered. The time of 50% recrystallization (t0.5) decreases noteworthily with the increase of deformation temperature. Apparent activation energy for static recrystallization of 195 kJ/mol, which is close to that of vanadium microalloyed steel, is obtained by calculating. The increasing trend of the driving force for recrystallization is opposite to that of the deformation temperature, which is attributed to the number of operative slip system increasing as temperature increasing.
文摘A numerical study based on the finite volume method has been performed to study the three-dimension natural convection in a parallelogrammic top side opened cavity filled nanofluid with partially heated square at the bottom side.Results are obtained for different governing parameters such as nanoparticle concentration (φ) from 0 to 0.05,inclination angle of the back and front walls (α) from 5° to 75°,Rayleigh number from 10^3 to 10^5,and length of heater changer from 0.1 to 1.The main finding from the obtained result showed that the inclination angle and nanoparticle volume fraction affect the flow structure and enhance the heat transfer.
文摘A multi-heat pipe is a device for heat transmission. It is composed of a heating section, a cooling section and an adiabatic section. The heating and cooling sections are the same and both are connected by four circular parallel tubes. This experimental study is performed to investigate heat transfer performance of a multi-heat pipe in the vertical orientation using pure water and GO (graphene oxide)/water nanofluid. GO/water nanofluids were synthesized by the modified Hummers method with 0.05%, 0.1%, 0.15%, and 0.2% volume concentrations. The thermal performance has been investigated with varying heat flux in the range of 10-30 W and 100% fill charge ratio. Wall temperature, thermal resistance, and heat transfer coefficient of the heat pipe are measured and compared with those for the heat pipe using pure water. The experimental results show that the evaporator wall temperature with GO nanofluid is lower than that of the base fluid. Also, the heat pipe that charged with nanofluids showed lower thermal resistance compared with pure water. Heat transfer enhancement is caused by suspended nanoparticles and is pronounced with the increase in particle volume fraction.