The hydrocarbon detection techniques used currently are generally based on the theory of single-phase medium, but hydrocarbon reservoir mostly is multi-phase medium, therefore, multisolutions and uncertainties are exi...The hydrocarbon detection techniques used currently are generally based on the theory of single-phase medium, but hydrocarbon reservoir mostly is multi-phase medium, therefore, multisolutions and uncertainties are existed in the result of hydrocarbon detection. This paper presents a fast way to detect hydrocarbon in accordance with BOIT theory and laboratory data. The technique called DHAF technique has been applied to several survey area and obtained good result where the coincidence rate for hydrocarbon detection is higher than other similar techniques. The method shows a good prospect of the application in hydrocarbon detecting at exploration stage and in reservoir monitoring at production stage.展开更多
A carrier type gamma irradiator is an advanced device currently installed in Qingdao Irra- diation Center (QIC) and has been put into operation for nine years in Qingdao, China. It utilizes Co-60 as the radiation sour...A carrier type gamma irradiator is an advanced device currently installed in Qingdao Irra- diation Center (QIC) and has been put into operation for nine years in Qingdao, China. It utilizes Co-60 as the radiation source; the initial Co-60 loading is 1.48×1016 Bq (0.4 million Curies). Rubber, natural and synthetic polymers, heat-shrinkable films and tubes, disposable medical supplies, some foods and drugs have been irradiated for test in the past. Especially a great success achieved on the radiation of compound food for young shrimp. The practice demonstrates that the bacteria in the compound food can be de- stroyed by the irradiation at optimum dosage between 5 000–6 000 Gy.展开更多
基金The project is sponsored by the Innovation Foundation of Key Lab of Geophysical Exploration under CNPC.
文摘The hydrocarbon detection techniques used currently are generally based on the theory of single-phase medium, but hydrocarbon reservoir mostly is multi-phase medium, therefore, multisolutions and uncertainties are existed in the result of hydrocarbon detection. This paper presents a fast way to detect hydrocarbon in accordance with BOIT theory and laboratory data. The technique called DHAF technique has been applied to several survey area and obtained good result where the coincidence rate for hydrocarbon detection is higher than other similar techniques. The method shows a good prospect of the application in hydrocarbon detecting at exploration stage and in reservoir monitoring at production stage.
基金Supported by National Natural Science Foundation of China (No. 40276026), and also by Open Foundation of State Key Laboratory of Estuarine and Coastal Research, East China Normal University (No. 200406).
文摘A carrier type gamma irradiator is an advanced device currently installed in Qingdao Irra- diation Center (QIC) and has been put into operation for nine years in Qingdao, China. It utilizes Co-60 as the radiation source; the initial Co-60 loading is 1.48×1016 Bq (0.4 million Curies). Rubber, natural and synthetic polymers, heat-shrinkable films and tubes, disposable medical supplies, some foods and drugs have been irradiated for test in the past. Especially a great success achieved on the radiation of compound food for young shrimp. The practice demonstrates that the bacteria in the compound food can be de- stroyed by the irradiation at optimum dosage between 5 000–6 000 Gy.